HPS Titan. Encapsulated Transformers for Harsh Environments

Similar documents
HPS TITAN HPS TITAN. Three Phase. Single Phase

HPS Fortress. Encapsulated Transformers for Commercial Applications

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS

Inexpensive as. Applications

HPS Fortress. Commercial Encapsulated Distribution Transformers

HPS EnduraCoil. Cast Resin Transformer

HPS Fusion General Purpose Enclosed Transformer

North American Capabilities

Our Global Solutions CAPABILITIES

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

Jefferson Electric Class I Division 2 Transformers for hazardous locations

Dry Type Distribution Transformers

Dry Type Distribution Transformers

HPS Spartan Industrial Open Core & Coil Control Transformer

Transformers 6. Gross Automation (877)

HPS Fusion General Purpose Enclosed Transformer

General Purpose Buck - Boost Wiring Diagrams... 86

Totally Enclosed Non-Ventilated

HPS Spartan. Industrial Open Core & Coil Control Transformer

Three Phase Transformers

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

HPS Imperator. Innovative Solutions. Progressive. Encapsulated Machine Tool Industrial Control Transformers

European Capabilities

Non-Ventilated Automation Transformers 6

Dry Type Distribution Transformers

30 KVA Transformer - 480V 3 Phase to 208Y/120V - NEMA 3R Enclosure - Copper Windings

Three-Phase Ventilated

Features, Benefits and Functions

Single-Phase Ventilated

75 kva Transformer - 480V Delta Primary - 208Y/120 Wye-N Secondary - NEMA 3R - K-13 - Copper Winding

Transformer Disconnects Specifying Product Catalog Numbers

AT120A-E; AT140A-E; AT150A,B,D-F; AT160B; AT175A-D,F Transformers

Low Voltage Lighting Power Supplies

Dry-Type Transformers Mini-Power Centers

750 kva Transformer V Delta Primary Voltage - 480Y/277 Wye-N Voltage Secondary - NEMA 3R

90 kva Transformer - 208Y Wye-N Primary Voltage - 230Y Wye-N Secondary Voltage - NEMA 3R

Transformer Disconnects

Hubbell Marine Isolation Transformers 15 kva and 25 kva Models

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY

HPS Imperator. Innovative Solutions. Progressive. Encapsulated Machine Tool Industrial Control Transformers

PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures

PH250MQMJ CNTL 250VA 240X X240

Machine Tool Industrial Control Transformers

75 kva Isolation Transformer - 480Y Wye-N Primary - 208Y/120V Secondary - NEMA 3R Enclosure

XPF. XPFMax Performer/al FEATURES TECHNICAL SPECIFICATIONS

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

Dry Type Distribution Transformers

Multi-Pak Group Control

NEMA 1 ( IP23 ) NEMA 12 ( IP54 ) Spec-Tech Industrial Electric

75 kva Transformer - 208V Delta Primary Voltage - 480V Delta Secondary Voltage - NEMA 3R

Engineered solutions for power and the environment

Transformer Disconnects

45 kva Isolation Transformer - 480V Delta Primary - 400V Delta Secondary - N3R - Copper Windings

Industrial Control Transformers

Pauluhn ZPL explosionproof LED luminaires For drilling and marine applications

Distribution Dry Type Transformers 600 Volts Class Single and Three Phase Selection

Industrial Control Power Transformers Class MT

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Industrial Control Transformers

Product Specification Sheet #3LD2.1

112.5 kva Isolation Transformer - 440V Delta Primary - 110V Delta Secondary - NEMA 3R

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry.

Features and Benefits

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

The LED Driver Expert

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

Wiring Diagram Number

Medium Voltage Metal-Enclosed Switches

C-Box Screw Cover with Knockouts NEMA 1. Commercial Enclosures Junction Boxes

Medium Voltage Metal-Enclosed Switches

P-9. ALPN, APPN and AGPN Series: Explosionproof, Dust-Ignitionproof, Watertight Non-Factory Sealed.

Midwest Dry Type Transformers

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire

MS303DS MS-303 3P Man CNT Only. Features. Dimensions and Weight. Long Description

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

1.1. Switching Devices

Transformer Installation, Operation, and Maintenance Manual

Specification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

1321 Power Conditioning Products

Pump Motors. Information. General. Single Phase Motors. Industrial Motors. General Purpose. Severe Duty Motors

Industrial Control Power Transformers

Quantum LMV. Low and Medium Voltage AC Induction Totally Enclosed Fan Cooled Motors. GE Power Conversion

Selection and application guide

steel standard SST DUCK components Epoxy Resin Rated Insulation System recognized stainless steel output shaft seal

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

Type FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

SAFJ LED SERIES S A L E D. Hazardous Location Compact LED

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

2 SLR Series Line Reactors... 50

Steel Outlet Boxes 4 11 /16" Welded

Packing Data Installation Instructions

Order Toll-Free: Fax:

C1000 Series Automatic Cap Bank

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Transcription:

HS Titan Encapsulated Transformers for Harsh Environments

HS Titan Encapsulated Transformers for Harsh Environments The HS Titan line of transformers have been designed for installation in harsh environments where efficiency and performance are key. Typical applications include institutional, commercial, industrial, petrochemical, marine, mining, etc. HS Titan designs provide: Superior erformance Compact Efficient Design Easy Installation and Hook-up HS Titan Series transformers are UL Listed for Class 1, Division 2, roups A, B, C, and D Hazardous Locations and also meet ABS Type Approval for Marine Duty Service and Offshore Applications - Electrical Distribution and ropulsion. With a North American Temperature Classification of T3C, the HS Titan Series will remain cool under load. HS TITAN Single hase HS TITAN Three hase ALICATIONS etrochemical Marine Industrial AOVALS ANSI/ISA 12.12.10 - File No. E258346 (Class 1, Division 2, roups A, B, C, and D Hazardous Locations) - T3C Temperature Classification UL 508 Listed - File No. E258346 UL Certificate No. 04-HS435190/1-DA (Marine Duty Service and Offshore Applications) ABS Type Approval Oil & as Mining Wastewater

HS Titan Standard Features Features Single hase Three hase Voltage roups 5 standard voltage groups 5 standard voltage groups s 0.5 to 37.5 2 to 150 Frequency 60 Hz (50/60 Hz on units with 380V primary) 60 Hz (50/60 Hz on units with 380V primary) Electrostatic Shield Optional on 0.50 Standard on 0.75 to 37.5 Standard on all units Encapsulated Enclosure All units are encapsulated with electrical grade silica sand and resin compounds Heavy Duty Type 3 Optional Type 4, 4X (stainless steel) and 12 Heavy Duty Type 3 Optional Type 4, 4X (stainless steel) and 12 Optional gasket kit Terminations Front accessible separated high and low voltage lead wires or copper tabs Top accessible separate high and low voltage lead wires or copper tabs Insulation System Mounting Conduit Knockouts Approvals Warranty 130 C (80 C rise) up to 1 180 C (115 C rise) 1.5 to 37.5 Standard wall mounting with keyhole mounting slots. Lifting provisions standard from 5 to 37.5. 130 C (80 C rise) up to 5 (Optional on 6 to 150 ) 180 C (115 C rise) 6 to 150 Standard wall mounting with keyhole mounting slots 2 to 15 (Optional wall mounting kit available for 30 and 45 ). Floor Mounted 25 to 150. Lifting provisions standard on 6 to 150. For rear and side entry into an easily accessible and spacious wiring compartment. ANSI/ISA 12.12.10 - File No. E258346 (Class 1, Division 2, roups A, B, C, and D Hazardous Locations) - T3C Temperature Classification UL 508 Listed - File No. E258346 UL Certificate No. 04-HS435190/1-DA (Marine Duty Service and Offshore Applications) ABS Type Approval All HS standard catalog encapsulated transformers come with a 10 year limited warranty (lease refer to the HS standard Transformer roducts Warranty for full details) Options and Accessories The following options and accessories are available on all standard and custom three phase encapsulated hazardous location transformers. Optional Type 4/12 asket Kits reviously ordered three phase HS Titan encapsulated transformers in standard Type 3 rated NQT enclosures can easily be converted to a Type 4 or 12 rating by ordering and installing the appropriate gasket kit as listed in the table on page 6. Optional Stainless Steel Enclosure Optional Type 4 rated NQT stainless steel enclosures are identical to the standard steel enclosure designs, but are designed using Type 316 stainless steel in accordance with ANSI, NEMA, UL and ABS requirements for indoor, outdoor and marine duty applications. If your application calls for a HS Titan Series unit in a stainless steel enclosure, just add the suffix 7 to the end of the standard HS part number. (e.g. 045KBKF is a standard unit. For stainless steel change the part number to 045KBKF7.)

HS Titan Encapsulated Transformers for Harsh Environments Single hase roduct Specifications 208/240/277V rimary, 120/240V Sec. 60 Hz 600V rimary, 120/240V Sec. 60 Hz For shielded unit 0.50, replace the suffix CB with a KB 0.50 QC50YECB NQ2 19 0.75 QC75YEKB NQ2 21 1 Q1C0YEKF NQ3 28 1.5 Q1C5YEKF NQ3 36 2 Q002YEKF NQ4 44 3 Q003YEKF NQ4 56 5 Q005YEKF NQ5 134 7.5 Q007YEKF NQ5 160 10 Q010YEKF NQ6 204 15 Q015YEKF NQ6 248 25 Q025YEKF NQ7 345 37.5 Q037YEKF NQ8 476 For shielded unit 0.50, replace the suffix CB with a KB 0.50 QC50ECB NQ2 15 0.75 QC75EKB NQ2 18 1 Q1C0EKF NQ3 27 1.5 Q1C5EKF NQ3 31 2 Q002EKF NQ4 40 3 Q003EKF NQ4 52 5 Q005EKF NQ5 114 7.5 Q007EKF NQ5 129 10 Q010EKF NQ6 197 15 Q015EKF NQ6 234 25 Q025EKF NQ7 285 37.5 Q037EKF NQ8 454 347/380V rimary, 120/240V Sec. 50/60 Hz Export* rimary, 120/240V Sec. 50/60 Hz For shielded unit 0.50, replace the suffix CB with a KB 240 X 480V rimary, 120/240V Sec. 60 Hz For shielded unit 0.50, replace the suffix CB with a KB 0.50 QC50FECB NQ2 18 0.75 QC75FEKB NQ2 20 1 Q1C0FEKB NQ3 26 1.5 Q1C5FEKF NQ3 36 2 Q002FEKF NQ4 55 3 Q003FEKF NQ5 88 5 Q005FEKF NQ5 130 7.5 Q007FEKF NQ6 145 10 Q010FEKF NQ6 155 15 Q015FEKF NQ6 248 25 Q025FEKF NQ7 345 37.5 Q037FEKF NQ8 476 0.50 QC50LECB NQ2 23 0.75 QC75LEKB NQ2 24 1 Q1C0LEKB NQ3 28 1.5 Q1C5LEKF NQ3 35 2 Q002LEKF NQ4 47 3 Q003LEKF NQ4 62 5 Q005LEKF NQ5 131 7.5 Q007LEKF NQ5 155 10 Q010LEKF NQ6 220 15 Q015LEKF NQ6 248 25 Q025LEKF NQ7 345 37.5 Q037LEKF NQ8 476 For shielded unit 0.50, replace the suffix CB with a KB 0.50 QC50XECB NQ2 15 0.75 QC75XEKB NQ2 20 1 Q1C0XEKB NQ3 32 1.5 Q1C5XEKF NQ3 35 2 Q002XEKF NQ4 54 3 Q003XEKF NQ5 105 5 Q005XEKF NQ5 138 7.5 Q007XEKF NQ6 189 10 Q010XEKF NQ6 222 15 Q015XEKF NQ7 300 25 Q025XEKF CF CF 37.5 Q037XEKF CF CF CF = consult factory *Export = 190/200/208/220/240 1 X 380/400/415/440/480 1 rimary Volts Note 1 : The primary voltage ratio of 240 or 480 is available at 60Hz only with secondary voltage of approximately 130/262V.

Single hase Enclosure Drawings and Dimensions A B D ØN.39 Figure 1 C F E A/2 H ØN K (K.O.) K (K.O.) FONT VIEW SIDE VIEW VIEW A ØM B ØN D.34 Figure 2 C F E K (K.O.) K (K.O.) H ØN L FONT VIEW SIDE VIEW VIEW Fig # A B C D E F H K 1 L M N NQ0 1 3.75 5.25 7.25 2.50 5.63 6.25 1.50 2.00 -- 0.88 -- -- 0.22 1.25 -- NQ1 1 4.50 5.75 7.25 3.13 5.63 6.25 1.50 2.00 0.81 0.88 -- -- 0.22 1.25 -- NQ2 1 5.00 4.75 9.25 3.88 7.75 8.25 1.50 2.00 1.00 0.88 X 1.13 X 1.38 -- -- 0.22 1.25 -- NQ3 1 5.88 5.50 10.50 4.13 8.25 9.00 1.50 2.00 1.25 0.88 X 1.13 X 1.38 -- -- 0.28 1.25 -- NQ4 1 7.00 6.50 11.75 5.38 9.50 10.25 1.75 2.00 1.50 0.88 X 1.13 X 1.38 -- -- 0.28 1.25 -- NQ5 2 10.00 7.75 17.25 7.38 15.38 15.25 2.375 2.00 4.00 1.13 X 1.38 6.00 0.75 0.44 1.25 1.68 NQ6 2 12.25 9.25 20.88 9.38 18.13 18.88 2.00 2.00 5.00 1.38 X 2.50 8.00 0.75 0.44 2.00 1.68 NQ7 2 14.50 10.75 21.38 11.63 18.63 19.38 2.00 2.00 6.00 1.38 X 2.50 10.00 0.75 0.44 2.00 1.81 NQ8 2 14.50 10.75 27.38 11.13 24.50 24.88 2.00 2.00 6.00 1.38 X 2.50 10.00 0.75 0.56 2.00 1.81 1 Knockout (K) sizes are actual diameter of knockout, not conduit sizes Optional stainless steel enclosures are available

HS Titan Encapsulated Transformers for Harsh Environments Three hase roduct Specifications 480V rimary, 208Y/120V Sec. 60Hz 600V (Y) rimary, 240V (D) Sec. 60Hz 2 002KBKB NQT3 49 3 003KBKB NQT3 86 6 006KBKF NQT4 160 9 009KBKF NQT5 262 15 015KBKF NQT6 304 30 030KBKF NQT7 478 45 045KBKF NQT8 642 75 075KBKF NQT9 1450 112.5 112KBKF NQT10 2100 150 150KBKF NQT11 2650 2 002DKB NQT3 51 3 003DKB NQT3 68 6 006DKF NQT4 146 9 009DKF NQT5 211 15 015DKF NQT6 270 30 030DKF NQT7 515 45 045DKF NQT8 740 75 075DKF NQT9 CF 112.5 112DKF NQT10 CF 150 150DKF NQT11 CF CF = consult factory 480V(D) rimary, 240V(D) Sec. 600V rimary, 208Y/120V Sec. 60Hz 2 002KDKB NQT3 52 3 003KDKB NQT3 68 6 006KDKF NQT4 182 9 009KDKF NQT5 250 15 015KDKF NQT6 312 30 030KDKF NQT7 540 45 045KDKF NQT8 650 75 075KDKF NQT9 1230 112.5 112KDKF NQT10 2100 150 150KDKF NQT11 2650 60Hz 2 002BKB NQT3 85 3 003BKB NQT3 94 6 006BKF NQT4 146 9 009BKF NQT5 211 15 015BKF NQT6 340 30 030BKF NQT7 605 45 045BKF NQT8 770 75 075BKF NQT9 1350 112.5 112BKF NQT10 3150 150 150BKF NQT11 3200 600, 480V rimary, 480Y/277V Sec. 60Hz 2 002QKKB NQT3 65 3 003QKKB NQT3 69 6 006QKKF NQT4 190 9 009QKKF NQT5 270 15 015QKKF NQT7 380 30 030QKKF NQT7 472 45 045QKKF NQT8 680 75 075QKKF NQT9 1650 112.5 112QKKF NQT10 CF 150 150QKKF NQT11 CF CF = consult factory Optional asket Kits Selection Table Enclosure NQT3 NQT4 NQT5 NQT6 NQT7 NQT8 NQT9 NQT10 NQT11 asket Kit /N NQT3K NQT4K NQT5K NQT6K NQT7K NQT8K NQT9K NQT10K NQT11K

Three hase Enclosure Drawings and Dimensions A D Lifting Lifting rovision rovision on Lifting NQT4, on rovision NQT4, NQT5 NQT5 and on NQT6. NQT4, and NQT6. NQT5 and NQT6. A A D D H H 1.26 1.26 Figure 1 Easy access to wiring Easy compartment access to Easy wiring access compartment to wiring compartment via (4) HHCS on top via cover. (4) HHCS on via top (4) cover. HHCS on top cover. E E C q 1.0(2) B E C q 1.0(2) B K (K,O)(4) K (K,O)(4) q N(4) q N(4) q N(4) All Dimensions in Inches All Dimensions All in Inches Dimensions in Inches FONT VIEW FONT VIEW FONT VIEW FONT VIEW SIDE VIEW SIDE VIEW SIDE VIEW EA VIEW EA VIEW EA VIEW AA A F L F L H H 0.69 0.69 Typ. 0.69 Typ. Typ. Easy Easy access access Easy to access to wiring wiring to compartment wiring compartment via via via ABS ABS approved ABS approved hardware hardware on on top top cover. on cover. top cover. 0.56 0.56 Typ. Typ. K (K,O)(4) K (K,O)(4) Figure 2 The The Lifting Lifting The Lifting rovisions rovisions on on NQT7, on NQT7, NQT8 NQT8 and NQT8 and NQT9 NQT9 and NQT9 enclosures enclosures are are are located located in in the the wiring in wiring the wiring compartment. compartment. C C M M 3.0 3.0 DD D FONT FONT VIEW VIEW θ N(4) θ N(4) E E B B SIDE VIEW SIDE SIDE VIEW VIEW 0.63 0.63 Typ. Typ. All Dimensions in Inches EA VIEW Fig # A B C D E F H K 1 L M N NQT2 1 9.38 4.94 8.63 8.38 4.00 -- 7.06 2.38 4.50 0.88 X 1.13 -- -- 0.28 1.81 2.44 NQT3 1 12.38 5.44 11.13 11.38 6.50 -- 9.50 2.38 5.50 0.88 X 1.13 -- -- 0.28 1.81 3.44 NQT4 1 15.19 6.94 15.13 13.88 9.25 -- 13.56 1.88 5.50 0.88 X 1.13 -- -- 0.28 3.06 4.19 NQT5 1 16.63 10.25 16.63 14.50 8.25 -- 13.88 2.69 10.00 1.38 X 1.75 -- -- 0.41 4.50 2.25 NQT6 1 19.25 10.44 16.63 17.50 8.25 -- 13.56 2.69 12.50 1.38 X 2.50 -- -- 0.41 4.50 2.50 NQT7 2 20.25 13.00 23.38 12.00 11.75 11.38 17.94 2.50 13.75 1.38 X 2.50 4.25 17.94 0.56 -- 2.13 NQT8 2 22.25 13.00 28.38 14.00 11.75 11.38 21.94 2.50 15.75 1.38 X 2.50 4.25 21.94 0.56 -- 2.13 NQT9 2 31.25 16.00 29.88 18.00 14.75 14.13 23.94 2.75 22.75 2.00 X 3.00 6.50 23.94 0.56 -- 3.13 NQT10 2 38.44 26.00 39.13 23.50 24.00 20.80 32.50 6.40 24.75 2.50 X 3.63 8.00 32.50 0.69 -- 6.84 NQT11 2 37.38 30.00 45.63 23.50 28.00 22.00 39.00 6.95 24.75 2.50 X 3.63 8.00 39.00 0.69 -- 6.31 1 Knockout (K) sizes are actual diameter of knockout, not conduit sizes Optional stainless steel enclosures are available

EUOE CANADA EUOE UNITED INDIA STATES INDIA CANADA HS 595 Southgate Drive uelph, Ontario N1 3W6 Tel: (519) 822-2441 Fax: (519) 822-9701 Toll Free: 1-888-798-8882 sales@hammondpowersolutions.com UNITED STATES HS 1100 Lake Street Baraboo, Wisconsin 53913-2866 Tel: (608) 356-3921 Fax: (608) 355-7623 Toll Free: 1-866-705-4684 sales@hammondpowersolutions.com EUOE Hammond ower Solutions Via Angelo Schiatti, 12 36040 Meledo di Sarego (VI) Italy Tel: +39 0444 822 000 Fax: +39 0444 822 065 info@hpseurope.eu INDIA ETE - Hammond ower Solutions vt. Ltd. -9 to 11, Bhavya s Sree Arcade Erragadda, Hyderabad, A.. - 500 018 Tel: 040-23813593, 23812291 Fax: 040-23706741 marketing@petetransformers.com Distributed by: Scan this Q code with your smartphone to view additional information on the HS Titan. www.hammondpowersolutions.com Literature No.: TSETB8 Issue Date: October 2014