JET PUMP INSTALLATION MANUAL. motralec SHALLOW WELL JET PUMPS

Similar documents
HALLMARK INDUSTRIES INC

INSTALLATION INSTRUCTIONS MODELS S S SHALLOW WELL & CONVERTIBLE JET PUMPS PAGE 3 PAGE 8

Material required for drilled well application (indoor use only)

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

Trouble Shooting Guide EWA, 3-phase (D2422)

Model T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP

MODEL SS INSTALLATION INSTRUCTIONS

OWNER S MANUAL CONVERTIBLE JET PUMP

Installation Vertical Pump: Installation 'CM' and 'CDM' Style: Operation:

END SUCTION CENTRIFUGAL PUMPS

LAWN SPRINKLER, IRRIGATION PUMP

Installation Instructions and Parts Manual CPJ SERIES JET PUMPS. Shallow Well Jet Pumps. Convertible Jet Pumps. Ejectors (Purchase separately)

INSTALLATION INSTRUCTIONS

SUBMERSIBLE ELECTROPUMPS 50 HZ

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

Potable Water Convertible Jet Pumps

INSTALLATION INSTRUCTIONS

SHALLOW WELL JET PUMP

Farval. Dualine Installation System Start-Up. Bulletin DL300 BIJUR DELIMON INTERNATIONAL

STAR STOP SHALLOW WELL JET PUMP

Installation & Operating Manual

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

Installation & Operating Manual

Portable Oil Free Silent Series Compressor Operating Instructions

3" & 4" Cast Iron Self-Priming Centrifugal Pump Instruction Manual

PRESSURE BOOSTER 150

SUBMERSIBLE PUMPS

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

END SUCTION CENTRIFUGAL PUMPS

INSTALLATION INSTRUCTIONS MODELS S S S S SSN S SSW SSN SPRINKLER PUMPS

Models 3305P, 3307P, 3310P

k. Components not properly adjusted. Refer to machine technical manual for proper adjustment of components.

Hydropak Booster Systems. Series motralec

KP-C Series. Close Coupled End Suction Centrifugal Pumps. Installation, Operation and Maintenance

Owners Manual: - Pumps

Pump Installation & Service Manual

INSTALLATION & OPERATING INSTRUCTIONS

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

6 Litre Oil-Less Air Compressor

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

DO NOT INSULATE BELOW THIS LINE. * For sizes 1/2" to 1 1/2" add 2 1/2" to 'C' dimension.

IMPORTANT SAFETY INSTRUCTIONS

MODEL P INSTALLATION INSTRUCTIONS

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

390 Series Multi-Stage Vertical In-Line Centrifugal Pumps

WALKIE HIGH LIFT HYDRAULIC SYSTEM

SPECIFICATIONS: Tank Size: 80 gallons PUMP RPMs: 1050 CFM: 40PSI; 90 PSI Max Pressure: 150 PSI Thermal overload protection

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

NOTE: Visit our website at for video repair procedures, under the Tools section.

TYPE E Main Valve Sizes 3 /8 through 12

MS Series. Call Multi-Stage Deep Well Jet Pumps. For further operating, installation, or maintenance assistance:

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

Troubleshooting 3Z8 038 Rev B

MODEL MC1500 Installation and Operation Manual Important:

OWNER S MANUAL. Power-Injection-Gun PIG

HALLMARK INDUSTRIES INC. Deep Well Submersible Pumps Operating & Installation Instructions

M-3025CB-AV Fuel Pump

SS/SSH Submersible Pump. Owner s Manual

Pressurized Bead Filters

Table of Contents Illustrations

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST 60 CYCLE SELF-PRIMING CENTRIFUGAL PUMPS D SERIES MODELS

SERIES PC INSTRUCTION AND OPERATION MANUAL

Low Profile J Series Power Unit with Vane Pump

900 Series Split Case Fire Pump Systems

Series FP4100. Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien,

Vertical Jet Pumps. SSJ Series. Call OWNER S MANUAL

INSTALLATION INSTRUCTIONS MODEL Z Z Z Z 1.5 HP 115/230V Z Z 2.0 HP 115/230V Z Z

Self-Priming Horizontal Three and Four Stage Pumps

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

End Suction Centrifugal

SERVICING INSTRUCTIONS

OWNERS GUIDE TO INSTALLATION AND OPERATION OF 1/2-5 HP, 5, 7, 10, 15, 19 & 27 GPM 4 SUBMERSIBLE PUMPS

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

Series LM/LP. Installation and Operating Instructions LIMITED WARRANTY. Single Stage In-Line Centrifugal Pumps

6L Oil-less Air Compressor 53103

OWNER S TECHNICAL MANUAL

Section 10 Chapter 17

DW-DW VOX RICAMBI/SPARE PARTS DWG N 01357

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 13 HP DIRECT DRIVE PRESSURE WASHER CATALOG NO

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

HORIZONTAL SPLIT CASING PUMP

3-Wire Deep Well Submersible Pump

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

TURBOCHARGER Toyota Celica DESCRIPTION OPERATION TURBOCHARGING SYSTEMS All Models

MH Series - Horizontal Multistage Pump OWNER'S MANUAL

AQUAPUMP INDUSTRIES INSTALLATION & OPERATION MANUAL (SPARE PARTS LIST INCLUDED) MANUFACTURED BY: HORIZONTAL JET MONOBLOCK

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

Maintenance Information

Troubleshooting the Transmission Hydraulic System

MODEL INSTALLATION INSTRUCTIONS. 12 Volt UTILITY PUMP

Centrifugal PTO Pumps. 2 nd Edition

Maintenance Information

Transcription:

motralec 4 rue Lavoisier. ZA Lavoisier. 95223 HERBLAY CEDEX Tel. : 01.39.97.65.10 / Fax. : 01.39.97.68.48 Demande de prix / e-mail : service-commercial@motralec.com www.motralec.com JET PUMP INSTALLATION MANUAL SHALLOW WELL JET PUMPS STEP 1 Make sure the well is pumped clean and that sand and grit are absent. STEP 2 Before installing a shallow well or centrifugal pump make sure the total suction lift does not exceed 25 feet. STEP 3 For convertible jet pumps attach the ejector to the pump housing, making sure that the 1 1/4 and 1 tapped holes in the ejector match up with the 1 1/4 and 1 tapped holes in the pump housing. STEP 4 Install a 1 1/4 foot valve on the bottom of the suction pipe, on driven wells, where the well casing is used as suction pipe, install a 1 1/4 horizonal line check valve. STEP 5 Install a sanitary well seal onto the top of the 1 1/4 suction pipe to fit well diameter. Use 1 1/4 tee and a 1 1/4 plug at the top of the well seal to support suction pipe in the well. Install 1 1/4 union between well and 1 pressure pipe that will rest on the well seal to support the pipes and ejector or jet in well. A 1 1/4 tee or elbow can be used on the top of the 1 1/4 suction pipe which needs to be slightly higher than the 1 pressure pipe to make the connection to the pump housing. Install a compression coupling on both suction & pressure pipes staggering them apart from each other. Install 1 1/4 pipe into the 1 1/4 tap in the pump housing. Install 1 pipe in to the 1 tap in the pump housing. Join together with

SHALLOW WELL JET PUMPS CONT. two unions between the pump and the well. If vertical pump is being used, adapt the 1 1/4 and 1 pipes directly into the 1 1/4 and 1 taps in the pump housing and adapt some type of supports or legs from the foundation to brackets on the pump housing to support the weight of the pipes, ejector or jet in the well. STEP 6 Prime pump by pouring water into the discharge of the pump housing or automatic regulator that is mounted on the discharge of pump. STEP 7 Make sure pump is off! Check motor decal and make sure motor is wired for voltage being used. Make your wire connections in the pressure switch. STEP 8 Adjust regulator to maximum pressure, and start the pump. When pressure builds up on the pressure guage, start opening regulator slowly. The pump will start discharging water and the pressure will decrease. Continue to slowly open up regulator until pump starts to charge tones or pump starts to lose prime. At this point determine what your operating pressure is by the reading on the pressure guage. Adjust regulator back up about 5 pounds above this tone or prime loss pressure. Put a jam nut on regulator to secure adjustment. STEP 9 Make connection on the discharge of pump to the water tank. This connection can be made with galvanized or pvc pipe. DEEP WELL JET PUMP DOUBLE PIPE STEP 1 Make sure the well is pumped clean and that sand and grit are absent. STEP 2 Deep well pumps are always installed with the ejector or jet attached to the bottom of the suction and pressure pipe in the well. A foot valve must be used if the ejector does not have a built in check valve. A tail pipe may be used beneath the ejector with the foot valve at the bottom of the tail pipe. STEP 3 Connect foot valve to bottom of jet with 1 1/4 galvanized nipple or full length of 1 1/4 galvanized pipe. Connect 1 1/4 galvanized pipe to 1 1/4 tap in ejector or jet body. Connect 1 pipe to the 1 tap in ejector or jet body. Keep adding pipes until you reach the desired depth. As each pipe is added fill each with water after lowering in well. STEP 4 Install a double pipe sanitary well seal at the top of the well to keep out contamination and to support the pipe and ejector or jet in well. STEP 5 Use 1 galvanized elbow on top of pump. Connect suction pipe into tapped hole in housing or ejector. Pump needs to be installed at an uphill slope from the well with no dips or low spots to eliminate the possibility of air pockets. Pump needs to be mounted onto the foundation for smoother and quieter operation and prolonged motor life. STEP 6 Prime the pump! Be sure the suction pipe and pump housing are full of water with no trapped air pocket in suction line. STEP 7 Make sure power is off! Check motor decal and make sure motor is wired for voltage being used. Connect power voltage wire to terminals marked line voltage in pressure switch. Connect ground wire to ground terminal on pressure switch. STEP 8 Start pump! If pressure does not build after a reasonable time, stop the pump. Reprime and start again. Allow pump to operate briefly to purge air from the system. This procedure may have to be repeated until pump builds up pressure. STEP 9 Make connection on discharge of pump to water tank. This connection can be made with galvanized or pvc pipe. DEEP WELL JET PUMP SINGLE PIPE STEP 1 Make sure the well is pumped clean and that sand and grit are absent. STEP 2 Deep well pumps are always installed with the ejectors or jet attached to the bottom of the suction pipe in the well. A foot valve must be used if the ejector or jet does not have a built in check valve. A tail pipe may be used beneath the ejector or jet with the foot valve mounted on the bottom of the tail pipe.

STEP 3 Install foot valve to the bottom of the jet or on the bottom of the tail pipe, if the tail pipe is being used. Stretch leather cup washer to open up leathers for a better seal in the well casing. Connect the ejector or jet to 1 1/4 pipe and lower into the well. Keep adding pipes and lowering the ejector or jet into the well to the desired depth. Fill suction pipe with water as it is lowered into the well. Fill the well casing with water as each suction pipe is added. STEP 4 Install casing adapter onto 1 1/4 suction pipe, lossen the three flange bolts on the adapter and lower adapter onto the well casing, being careful not to damage the rubber gasket. Make sure the well adapter is all the way around. Tighten the three bolts, each evenly until tight. Fill the well adapter with water making sure both the 1 and 1 1/4 holes are full of water. STEP 5 Mount the pump onto the well adapter with gaskets and bolts, making sure that the 1 1/4 and 1 holes in pump line up with the holes in the adapter. STEP 6 Prime the pump by pouring water into the discharge of the pump housing or automatic regulator mounted in discharge of the pump on some models. STEP 7 Make sure the power is off! Check motor decal and make sure the motor is wired for the voltage being used. Make your wire connections in the pressure switch. STEP 8 Adjust the regulator to maximum pressure, start the pump when the pressure builds up on the pressure guage start opening the regulator slowly. The pump will start discharging water and the pressure will start decreasing as the discharge flow increases. Continue to slowly open up the regulator until pump starts to change tones or pump starts to loose its prime. At this point determine what your operating pressure is by reading the pressure guage. Adjust the regulator back up about 5 pounds above this tone or prime lost pressure. Use a jam nut on regulator to secure this adjustment. STEP 9 Make connection on discharge of pump to water tank. This connection can be made with galvanized or pvc pipe. TROUBLE SHOOTING A. PUMP WON T RUN CAUSE OF TROUBLE HOW TO CHECK HOW TO CORRECT 1. Blown fuse. Check to see if fuse is ok If blown, replace with fuse of proper size. 2. Low in voltage Use voltmeter to check pressure switch or terminals nearest pump If voltage is under recommended minimum, check the size of wiring from main switch on property. If ok, contact power company. 3. Loose, broken or incorrect wiring. 4. Defective Motor 5. Defective pressure switch 6. Tubing to pressure switch clogged Check wiring circuit against diagram. See that all connections are tight and that no short circuits exist because of worn insulation, crossed wire, etc. Check to see that switch is closed Check switch setting. Examine switch contacts for dirt or excessive wear. Remove tubing and blow through it. Rewire any incorrect circuits. Tighten connections, replace defective wires. Repair or take to motor shop. Adjust switch settings. Clean contacts with emory cloth if dirty. Clean and replace if plugged.

TROUBLE SHOOTING CONT. A. PUMP WON T RUN CONT.. CAUSE OF TROUBLE HOW TO CHECK HOW TO CORRECT 7. Impeller or seal 8. Defective start capacitor 9. Motor shorted out Turn off power, then use screwdriver to turn impeller or motor. Use an omhmmeter to check resistance across capacitor. Needle should jump when contact is made. No movement means an open capacitor, no resistance means capacitor is shorted. If fuse blows when pump is started ( and external wiring is ok) motor is shorted. If impeller won t turn, remove turn housing and locate source of binding. Replace capacitor or take motor to a service station. Replace Motor B. MOTOR OVERHEATS AND OVERLOAD TRIPS OUT. 1. Incorrect line voltage Use voltmeter to check at pressure switch or terminals nearest pump If voltage under recommended minimum, check size of wiring from main switch on property. If ok, contact power company. 2. Motor wired incorrectly 3. inadequate ventilation 4. Prolonged low pressure delivery Check motor wiring diagram Check air temperature where pump is located. Iif over 100 degrees F overload may be tripped out on external head Continuous operation at very low pressure places heavy overload on pump. This can cause overload protection to trip. Reconnect for proper voltage as per wiring diagram. Provide adequate ventilation or move pump. Install globe valve on dicharge line and throttle to increase pressure C. PUMP STARTS AND STOPS TOO OFTEN 1. Leak in the pressure tank 2. Defective air volume control 3. Leak on discharge side of system 4. Leak on suction side of system 5. Leak in foot valve. Apply soapy water to entire surface above water line. If bubbles appear, air is leaking from the tank. This will lead to a waterlogged tank. Make sure control is operating properly. If not, remove and examine for plugging. Make sure all fixtures in plumbing system are shut off. Then check all units (especially ballcocks) for leaks. Listen for noise of water running. On shallow well units, install pressure guage on suction side. On deep well systems, attach a pressure guage to the pump. Close the discharge line valve. Then using a bicycle pump or air compressor, apply about 30 psi pressure to the system. If the system will not hold this pressure when the compressor is shut off, there is a leak on the suction side. Pull piping and examine foot valve Repair leaks or repair tank. Adjust switch settings. Clean with emory cloth if dirty. Repair leaks as necessary. Make sure above ground connections are tight. Repeat test. If necessary, pull piping and repair leaks. Repair or replace defective valve

TROUBLE SHOOTING CONT. D- PUMP WON T SHUT OFF CAUSE OF TROUBLE 1. Wrong pressure switch setting or setting drift. 2. Defective pressure switch 3. Tubing to pressure switch clogged 4. Loss of prime 5. Low well level 6. Plugged ejector HOW TO CHECK Lower switch setting. If pump shuts off this was the trouble. Arcing may have caused switch contacts to weld together in closed position. Examine points and other parts of switch for defects. Remove tubing and blow through it. When no water is delivered check prime of pump and well piping. Check well depth against pump performance table to make sure pump and ejector are properly sized. Remove ejector and inspect HOW TO CORRECT Adjust switch to the proper setting. Replace switch if defective. Clean and replace if plugged. Reprime if necessary If undersized, replace pump or ejector. Clean and reinstall if dirty E - PUMP OPERATES BUT DELIVERS LITTLE OR NO WATER 1. Low line voltage 2. System incompletely primed 3. Air lock in suction line. 4. Undersized piping. 5. Leak in volume control or tubing 6. Pressure regulating wire stuck or incorrectly set. (Deep well only) 7. Leak on suction side of system 8. Low well level 9. Wrong pump-ejector combination. Use voltmeter to check at pressure switch or terminals nearest the pump. When no water is delivered, check prime of pump and well piping. Check horizontal piping between well and pump. If it does not pitch upward from the well to pump, an air lock may form. If system delivery is low, the discharge piping and/or plumbing lines may be undersized. Refigure friction loss. Disconnect air volume control tubing at pump and plug hole. If capacity increases, a leak exist in the tubing of control. Check valve setting, inspect valve for defects. On shallow well units, install pressure guage on suction side. On deep well systems, attach a pressure guage to the pump. Close the discharge line valve. Then using a bicycle pump or air compressor apply about 30 psi pressure to the system. If the system will not hold this pressure when the compressor is shut off, there is a leak in the suction side. Check well depth against pump performance table to make sure pump and ejector are sized correctly. Check pump and ejector models against manufacture s performance tables. If voltage under recommended minimum, check size to see if wiring from main switch on property. If ok contact power company. Reprime if necessary. Rearrange piping to eliminate air lock. Tighten all fittings and replace control if necessary. Reset, clean, or replace valve as needed. Make sure above ground connections are tight. Repeat test if necessary, pull piping and repair leaks. If undersized, replace pump or ejector. Replace ejector if wrong model is being used.

TROUBLE SHOOTING CONT. E - PUMP OPERATES BUT DELIVERS LITTLE OR NO WATER CONT... 10. Low water level in well. Shut off pump and allow well to recover. Restart pump and note whether delivery drops after continuos operation. If well is weak lower ejector (deep well pumps) use a tall pipe, or switch from shallow well to deep well equipment. 11. Plugged ejector. 12. Defective or plugged foot valve and/or strainer. 13. Worn or defective pump parts or plugged impeller. Remove ejector and inspect. Pull foot valve and inspect. Partial clogging will reduce delivery. Complete clogging will result in no water flow. A defective foot valve may cause pump to loose its prime, resulting in no delivery. Low delivery may result from wear or impeller or other pump parts. Disassemble and inspect. Clean, and reinstall if dirty. Clean, repair or replace if needed. Replace worn parts on entire pump. Clean parts if required. motralec 4 rue Lavoisier. ZA Lavoisier. 95223 HERBLAY CEDEX Tel. : 01.39.97.65.10 / Fax. : 01.39.97.68.48 Demande de prix / e-mail : service-commercial@motralec.com www.motralec.com