Specification Sheet for 2D LED Light

Similar documents
LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

INSTALLATION & MAINTENANCE MANUAL HBL

ASSEMBLY & FITTING INSTRUCTIONS P-LUX3 LED TRI-SENSOR LANTERN

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

PROFESSIONAL 270 o PIR MOTION DETECTOR

MAINTAINED LED CIRCULAR EMERGENCY CEILING LIGHT

Mightylite Elite 16W LED Wall Light with PIR

MAINTAINED LED DOUBLE SIDED SUSPENDED CEILING MOUNTED EMERGENCY LIGHT

18W Round LED Slimline Emergency Light

LED CANOPY with j-box

PMWS2W SURFACE MOUNT 2-WIRE WALL SWITCH

Dedicated PIR Light Controller c/w RF remote control for LEDPRO Floodlights

75% ENERGY SAVINGS 200W-600W HID Light Replacement

Compact Security FloodLight

Motion and Light Sensor Kit LHBAS51

Installation Instructions

Installation Instructions

3000W Dusk to Dawn Light Controller

MANUFACTURED IN THE UK

Doc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Start Waterproof LED START WATERPROOF LED 1265MM TWIN 4000K PRODUCT OVERVIEW

MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT

18W Low Energy. instructions. Instructions

25W LED Cross Bezel Bulkhead Light

Doc Ref: WD029/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

MANUFACTURED IN THE UK

LED.Commercial 12W LED DD

2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years

ECO CFL. with Photocell. Instructions. Model: ECO2DD Model: ECO3DD

UP TO 75% Up to 160Lm/W. UFO LED HIGH BAY 100W to 200W. Key Features. Image Show. 200W-600W HID Light Replacement

Single gang PIR switch Replaces a standard light switch or dimmer Turns off automatically Turns on automatically Security mode Switches all lighting,

Sieve Shaker 200mm/300mm - 8/12 inch SV003

Doc Ref: WD027/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

icebreaker icebreaker A C G GE Lighting 2D lamps are fitted as standard. I44

Emergency lighting units EM powerled

LED Security Wallpack Installation Instruction

Emergency lighting units EM LED Light Engines

With magnetic fixing With ON/OFF switch

TABLE OF CONTENTS Page:

Doc Ref: WD030/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Emergency lighting units EM powerled

Emergency lighting units EM powerled

TITAN. A range of elegant technical luminaires designed to withstand extreme vandalism in public spaces. 114 / Securlite

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM RANGE INSTALLATION NON-EMERGENCY LUMINAIRES PRE INSTALLATION

THE INTELLIGENT MOTION SENSOR TRACKING LIGHT

Emergency lighting units EM powerled

BH500 BH100 BH400 BH200 BH300 BH600 BH900 BH1100 BH700 BH1000 BH800. Series. Series. Series. Series. Series. Series. Series. Series. Series.

10W LED Die Cast Small Rectangle Bulkhead Light

LED emergency exit signage from Channel Safety Systems

LED Lighting. LED Reflector. LED Downlight. LED Tube. LED Plug-in Tube. LED Sensor Batten. LED Floodlight. LED Lighting

Emergency lighting units EM powerled

ASSEMBLY AND INSTALLATION INSTRUCTIONS

Installation Instructions: Eco SpunBay LED High Bays

5 m. length high efficiency adhesive flexible LED strip from the TROLL family Flexiled.

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

24 Hour Immersion Heater Time Controller

ADVANTAGES. The light fitting is suitable for emergency and orientation illumination of hallways, offices, warehouses and production shop floors.

Emergency lighting units EM powerled

TRUET5 EXT (DIMMABLE)

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Start Waterproof LED G3 fixed output START WATERPROOF LED G3 1500MM T 4K

120 LED DUAL HEAD SOLAR MOTION LIGHT

INDEX PAGE WHERE LIGHT CREATES COLOUR SERIES, EDITION 01

INSIGHT WHAT ARE YOU LOOKING FOR IN LED LIGHTING?

LED microwave sensor T8 tube light

2x 10W LED Slimline Floodlight Twin Flood

X20020 INFRESCO P 4kW Issue 4 User manual Date 16/02/16. Page 1 of 9 KEY FEATURES

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply

Emergency lighting units EM powerled

PRODUCT GUIDE MAKING SMART SOLUTIONS SIMPLE

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Installation Instructions

7 Lighting Technology

LED PROFILE - FLEXILED

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM E1, E7, S1 and S7 Recessed Ceiling Luminaires

INDEX PAGE WHERE LIGHT CREATES COLOUR SERIES, EDITION 01

All our Eterna Emergency Exit Signage comply with current Exit Signage Regulations using the Signs Directive format.

Security Lighting INSTRUCTION MANUAL 16W, 28W, 36W & 50W PIR Security LED Floodlight

Emergency lighting units EM series

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE

LIGHTING Autumn & Winter Offers 2018/2019

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Emergency Luminaire with LED Series EXLUX 6409/1

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Adjustable Pneumatic Time Delay Switch

DUALBRITE Motion Sensing Coach Light

HBDB High Bay Fixture with Occupancy Sensor

INSTALLATION MANUAL. Outdoor Series RP-SAL-8W-50K-SF-GY-G1, RP-SAL-30W-50K-SF-GY-G1. south if in northern hemisphere for example). sunlight.

SLIM LIGHT SERIES FOR NON MAINTAINED / MAINTAINED LUMINAIRE

Operating Instructions

LED Emergency Luminaires

EXI LED INTRODUCTION APPLICATION PRODUCT SPECIFICATION

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

LED light engine / OLED LED compact. Umodule STARK CLE 360 CLASSIC EM STARK CLE

Schaltgeräte GmbH GmbH Geschäftsbereich Leuchten

Technical Application Guide for UP-SHINE LED Batten Light UP-DB W

Technical Application Guide for UP-SHINE LED Batten Light UP-DB W

Technical Application Guide for UP-SHINE LED Batten Light UP-DB W

Transcription:

Specification Sheet for 2D LED Light Product Features LED light source, green and energy-saving; IP54 bulkhead, available to replace a 2D fitting; PC housing and opal diffuser; 3 Hours emergency; Microwave / Motion sensor: --Automatic dimming when detected area is unattended --Adjustable range (1-8m) C/w M20 x 1.5 IP54 Gland; Anti-glare design; No UV, no infrared, no other hazardous substances; No noise, no flicker, resistance from vibration; CE&ROHS compliant; Three years warranty. Available in retro-fit kit without housing Mechanical Structure Ref No BES.ES12021-C-2 12021 Standard LED Bulkhead BES.ES12021-S-2 12021 LED Bulkhead c/w Microwave sensor BES.ES12021-E-2 12021 LED Bulkhead c/w 3 hours emergency BES.ES12021-S-2 12021 LED Bulkhead c/w Microwave sensor & 3 hours emergency Product Dimensions

Technical Specifications Input voltage ( 50/60Hz) AC 100-240V Power consumption 12W (14W for emergency versions) PF >0.9 LED Driver output voltage DC 30V LED Driver output current 350mA ±15mA Light source Colour Temperature (CCT) 5630 SMD LED 50 PCS 3000K /4000K/ 6000K (optional) CRI >80 Luminous Flux Luminous efficacy 620-680Lm 58Lm /W for SN-ES12021-C-2 View angle 109 Housing material Polycarbonate IP Rating IP 54 Life Span Operating Temperature Dimension Package Net Weight Emergency: Type Battery(High-Temperature) Emergency output Up to 35,000 hours -10degC to 40degC 325*100mm *330*110mm 1.8KG Maintained 9.6V 1.6AH Ni-MH rechargeable 30% nominal power Emergency duration >3 Hours Charge time LED indication Test button Microwave Sensor: Sensor range Sensing interval Sensing interval output < 12Hours Red: charging; Green: fully charged; Yellow: battery fault or disconnected AC power on: Push and hold the button enter emergency mode release button to come back AC power mode 180 degree; 0.5-8M(adjustable) 10s to 5min max (adjustable) 25% of nominal power

APPLICATION Hotels Indoor lighting and display units Shopping centers Leisure centers Corridors Building Staircases

Installation Instruction These instructions should be read in full and retained after Installation for future reference. SAFETY It is recommended that this luminaire is installed by a qualified electrician and installed to the current 17 th edition of the IEE wiring regulations. Before installation or maintenance is carried out, ensure that the mains supply is turned off, and adequately isolated. Fig 1 Check that the total load of this and any other luminaires on the same circuit does not exceed that of the fuse or main circuit breaker. FIXING INSTRUCTIONS Twist and remove the diffuser from the base and lift away. Unscrew the 3 fixing screws (see Fig 1) to remove the LED gear tray and gain access to the terminal block. A safety chain is provided to prevent the gear tray from falling during installation. Fig 2 Drill 4 of eight fixing holes on the back of the base (see Fig 3). Then measure the position of the luminaire and ensure the fitting surface can bear the weight of the luminaire. Drill the marked holes and fit a suitable wall/surface plug (supplied). Then mark the position of the luminaire to the fitting surface. Feed the power supply cable through the cable entry and gland, then fix the luminaire to the wall through the 4 screws. (See Fig 4) Connect the cable to the terminal block as follow: For the BES.ES12021-C-2 and BES.ES12021-S-2 versions (see Fig.5): LIVE wire (Red or Brown) to the terminal marked L NEUTRAL wire (Black or Blue) to the terminal marked N EARTH wire (Green/Yellow) to the terminal marked For the BES.ES12021-E-2 and.beses12021-2 emergency versions: PERMANENT LIVE (Red or Brown) to the terminal marked PL SWITCH LIVE (Red or Brown) to the terminal marked SL NEUTRAL (Black or Blue) to the terminal marked N EARTH (Green/Yellow) to the terminal marked Fig 3 Fig 4 (Note: If there are only 3 lead wires from the main supply, please short PL and SL, and then connect Live Wire to PL or SL.) Ensure that there are no exposed conductors, loose or trapped cable strands, and re-fit the gear tray. Refit the diffuser by twisting. The luminaire is now ready for use. Fig 5

EMERGENCY VERSION ONLY Emergency function test button, (see Fig 1) after installation with the mains supply on, push the test button to test the emergency function, if the LED brightness is reduced to emergency brightness (30% of full brightness), the function is working. LED Indication Red indicates the battery is charging Green indicates the battery is fully charged Yellow indicates the battery is disconnected or damaged. Microwave sensor instructions The sensor is an active motion detector, it emits high-frequency electro-magnetic waves (5.8GHz) and receives their echo. The sensor detects the change in echo from the slightest movement in its detection zone. A microprocessor then triggers the switch light ON command. Detection is possible through doors, panes of glass or thin Walls. Important: persons or objects moving towards the sensor are detected best! Reach setting (sensitivity) Reach is the term used to describe the radius of the circular detection zone produced on the ground. After mounting the sensor light at a height of 2.5m, turn the reach control completely in anti-clockwise direction to select minimum reach(approx.1 m radius), and turn the reach control completely in a clockwise direction to select the maximum reach (approx.8m radius). The LED indicator will flash when the reach control is rotated It flashes 1 to 10 times, representing 1m to 8m for the radius of the detection zone. NOTE: The above detection distance is measured using a person who is between 1.6m~1.7m tall with an average build, moving at a speed of 1.0~1.5m/sec. if any of these variables are changed, the detection distance will also resultantly change. Light-control setting The chosen light response threshold can be infinitely from approx. 2-2000lux. Turn it fully anti-clockwise to select dusk- to-dawn operation at about 2 Lux. Turn it fully clockwise to select daylight operation at about 2000lux. The knob must be turned fully clockwise when adjusting the detection zone and performing the walk test in daylight. Time setting The light can be set to stay ON for any period of time between approx. 10sec (dial turned fully anti-clockwise ) and a maximum of 5min(dial turned fully clockwise). Any movement detected during the on time will reset the timer. The LED indicator will flash when adjusting the time setting dial. The number of flashes means the following: 1flash=10sec 2 flashes= 20sec 3 flashes= 30sec 4 flashes= 45sec 5 flashes=60sec 6 flashes=90sec 7 flashes=2min 8 flashes=3min 9 flashes=4min 10 flashes=5min NOTE: After the light switches off, it takes approx. 1sec before it is able to start detecting movement again. The light will only switch on in response to movement once this period has elapsed. 10sec~5min Note: This setting has not been used!

Troublesho oting Malfunction Possible Cause Remedy The luminaire will not work Wrong light-control setting selected Adjust setting Luminaire faulty Mains switch OFF Change luminaire Switch ON The luminaire is always ON Continuous movement in the detection zone Check zone setting The luminaire works without any identifiable movement The luminaire will not work despite movement The sensor not properly mounted for detecting movement reliably Movement occurred, but not identified by the sensor (movement over boundary wall, movement of a small Object in immediate luminaire vicinity etc.) Rapid movements are suppressed to minimize false triggering or the detection zone you have set is too small Securely mount sensor enclosure and luminaire Check zone setting Check zone setting