Rectangular fire damper TFER 30. pag. C-10

Similar documents
7/S5 FIRE DAMPER FD40. v 2.9 (en)

7/S1 FIRE DAMPER PPZEN. v 2.5 (en)

7/S6 FIRE DAMPER FDC40. v 2.9 (en)

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

PKI-C Cartridge Fire Dampers

Systemair Fire Dampers

TPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB

M A D E L. FOK-EIS-180 Fire dampers CE

PKIR3G, PKIS, PKIS3G and PKIS3GA

TPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD

Fire damper FK120/FK90 TECHNICAL DATA

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE

Fire/smoke damper EKO-JBG2

Systemair Fire Dampers

Fire Dampers. Types FKA FRL FRK 4/1/EN/1

DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8.

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

Fire/combustion gas damper EKO-JBL

Fire/smoke damper EKO-SRBG1

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Fire damper ETPR. Specifications. Product code example Fire damper ETPR

MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA

ESAS Smoke control damper

Smoke damper EKO-SRB1

Fire/combustion gas damper EKO-JBG

Fire damper BKA-EN. with general technical approval Z tested according to DIN EN

VARYCONTROL VAV Dual Duct Terminal Boxes

Combustion gas damper EKO-JB

CONSTANTFLOW Volume Flow Controllers

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance

VU120. Rectangular smoke evacuation damper. V22-EN-G 08/2017

Technical information

VU120. Rectangular smoke evacuation damper. V22-F 07/2015

Heights up to 1000 mm Fire resistance period up to 120 minutes

ROOF FAN ROOFMASTER STEC

FD-C Series. Circular Single Blade Externally Resettable Combination Fire and Volume Control Damper B RITAI N

Slot diffusers for ceiling installation

NEO. Fire Damper. air handling intelligence FIRE SAFETY FUNCTION

CU2. Wide-ranging rectangular fire damper up to C2-G 08/2015

TYPE EK-EU SMOKE CONTROL DAMPER

A B. Linear cylinder diffuser LC. pag. A-52

FK120/FK90 FIRE DAMPER» INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

Combustion gas damper EKO-SRB

Fire dampers ETCE and ETCS TECHNICAL DATA

series CEVH Smoke Evacuation Damper

series FSD-FLD Fire and smoke dampers UL Approval

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3

CR120. Optimized circular fire damper up to 120' C11-I 07/2015

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Bevent Rasch BSK Fire /04/2017

CR2. Circular fire damper C1-C 04/2010

CRE60 XF9499. Røgevakueringsspjæld Ø100-Ø630. AiR Ξ FORCE CRE60 XF9499 FORCE:

BSK-EN Fire damper INSTALLATION, MOUNTING AND OPERATING INSTRUCTIONS

CU-LT. Optimised rectangular fire damper up to C3-EN-J-06/2018

Type VSD35. Nominal length up to 1500 mm: one spigot

Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects

Bevent Rasch BSK6. - Fire /04/2017

Fire Safety Products. Product Overview

Shutter Fire Damper Type FSD GFSD 4/1.1/B/1

CU2-15. Rectangular fire damper 120' at 1500 Pa. C7-EN-I 06/2018

Fire Damper BSK-RPR. with general building supervisory approval Z

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

series Silencers

CU2/B. Battery assembly of max. 4 individual dampers. C31-EN-G 06/2018

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Technical documentation

Variable Air Volume Dampers

Smoke control damper RKI-90 Test certificate Z

1/11 29/06/2016 CONTENTS 1. GENERAL DUCTS, AIR VENTS, VALVES MONOBLOCK UNITS FILTRATION CONTROL...

TransShield Mode 1/2. Transfer Stainless Steel Sliding Plate Fire Dampers.

Ceiling swirl diffusers with perforated face plate

ROOFMASTER STEF-HT ROOF FAN

DCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description

CYCLONE F 400 smoke extraction casing

PK-I-Ex. Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S. Systemair Fire Dampers for Explosive Areas.

Pressure control damper ERPA

Motorized Fire Dampers

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

WDD/WSD - Grille. Halton WDD/WSD. Universal Grille

DAMPERS LSS - R. N-6230 SYKKYLVEN, NORWAY TEL FAX

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

SEMI RIGID THE PROFESSIONALS CHOICE

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

WAY MOTORISED COMPACT ZONE VALVES

Multileaf damper with actuator

BRC

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Rectangular smoke damper (remote controlled)

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

HIGH-POWERED VENTILATORS

Transcription:

pag. C-10 Description Rectangular fire damper with CE label in conformity to UNI-EN 15650, certified according to EN 1366-2, classified EI 120 S in accordance to EN 13501-3. Removable shifted kinematic mechanism in order to simplify the installation and to allow the eventual walled substitution. Release thermo-fuse with melting point certified at 70 C (72 C for motorised versions). Manual starting stick. Symmetric construction (blade in the box centre line) with resistance characteristics independent of fire origin direction. Tests Cold smokes passage seal with 300 Pa depression, on minimum and on maximum dimension damper (max. 200 m/h correct to 20 C, for at least 5 minutes). Thermo-isolation with temperature s increase control on box 4 sides in proximity to device, on device in proximity to box and on extraction duct, on maximum dimension damper (max. 180 C for each point, max. 140 C as points average). Hot smokes passage seal with 300 Pa depression, on maximum dimension damper (max. 360 m/h, correct to 20 C). Starting mechanism s solidity with 50 opening/closing cycles and following cold smokes seal test (first point). Thermo-fuse s intervention rapidity, that must release in two minutes from oven s ignition. Servomotor s solidity with functionality test after 10 000 opening/closing cycles for each of 4 disposable models (see Accessories section). Construction Galvanised sheet-steel box. Calcium silicate (external layers) and calcium sulphate (intermediate layer). Graphite base s thermo-expander. cold smokes seal s silicone gasket. Mineral fibre s thermo gasket. CE label (UNI-EN 15650) The fire damper TFER 30 is in conformity to UNI-EN 15650 and is provided of CE label, issued from legally certified institution. Dimensions B (mm) : 200-1500 (increments of 50) H (mm) : 200-800 (increments of 50) Versions TFER 30 (basic version) : it disposes from thermo-fuse locally directed release (fusion temperature certified at 70 C), manual starting stick and an end-stroke microinterruptor, signaling if the blade is in closing position (two contacts: NA and NC). As option it may have an interruption-current or currentlaunch electromagnet, for remote control s release (alarm control unit) and another end-stroke micro-interruptor (blade in opening position). Both can be easily added, also with already installed damper. TFER 30 M (version disposed for motor) : to be combined with a serie s ATF 2x servomotor, it disposes from thermo-fuse locally directed release, one internal and one external to the box (fusion temperature certified at 72 C), remote control release with current interruption, motorised starting and two end-stroke micro-interruptors, signaling blade s opening and closing position posizion (each one with two contacts: NA and NC). N.B. - The presence of at least one signaling micro-interruptor is recommended in conformity to UNI 10365 art. 4.9. To remember that the damper s running must be anyway guaranteed, also without electric current (art. 4.1 UNI 10365). Specifications Rectangular fire damper with CE label in conformity to UNI-EN 15650, certified according to EN 1366-2, classified EI 120 S in accordance to EN 13501-3. Suitable to installation on rigid vertical wall (also with two coupled units), light vertical wall (plasterboard) and horizontal slab. Removable shifted kinematic mechanism to simplify the installation. Release thermo-fuse calibrated at 70 C. Micro-interruptor notifying closed damper status. Manual starting stick.

pag. C-11 12 Key to symbols 1 - Symmetric box 2 - Mineral-fibre gasket 3 - Graphite thermo-expander gasket 4 - Cold smokes silicone seal gasket 5 - Activation plate gasket 6 - Multilayered refractory blade 7 - Kinematic mechanism link-control 8 - Thermo-fuse release s system 9 - Closing test button 10 - Thermo-fuse 11 - Security block 12 - Heat-sinks

pag. C-12 Installation N.B. A damper s fire resistance depends on device characteristics, that is the damper has not an own class resistance, but it s always depending on considered device. 1 - Rigid vertical wall N.B. Installation s operations (device s perforation, damper s positioning and filling) are completely described in the installation manual. N.B. The minimum distance between two fire dampers installed on two different ducts cannot be less than 200 mm. N.B. The minimum distance between the fire damper and structural elements around (ceiling, floor, walls) cannot be less than 75 mm. N.B. The 4 following installaton typology are allowed, corresponding to the tests conditions employed from certified laboratory. For each one, classification report allows the fire damper s employment in accordance to law, in the same conditions. 1 Rigid vertical wall Wall class REI 120 Wall thickness 100 mm Wall density 500 kg/m 3 Maximum duct dimensions (BxH) 1500x800 mm Damper class EI 120 S (300 Pa) ve i o 2 Rigid vertical wall - 2 vertical units (flange against flange) Wall class REI 120 Wall thickness 100 mm Wall density 500 kg/m 3 Maximum duct dimensions (BxH) 1500x1600 mm Damper class EI 120 S (300 Pa) ve i o 3 Lightweight insulated vertical wall (plasterboard + steel-wool + plasterboard) Wall class REI 120 Wall thickness 100 mm (25 + 50 + 25 mm) Wall density 100 kg/m 3 (steel-wool) Maximum duct dimensions (BxH) 1500x800 mm Damper class EI 120 S (300 Pa) ve i o 4 Horizontal slab Slab class REI 120 Slab thickness 150 mm Slab density 2200 kg/m 3 Maximum duct dimensions (BxH) 1500x800 mm Damper class EI 120 S (300 Pa) ho i o N.B. - As described in the installation manual, the air spaces resulting between the damper and its device must be filled with M10 or upper class mortar (EN 998-2).

pag. C-13 2 - Rigid vertical wall - 2 vertical units 3 - Lightweight insulated vertical wall Steel-wool lines Plates ATF 35 Plates ATF 35 N.B. - In case of flange against flange dampers (case 2) the couple must be executed through special plates ATF 35 (see Accessories section ) filling the gap between the two units with 100 kg/m 3 steel-wool lines (see Installation manual). N.B. - This installation typology is the most complicated one and requests to pay more attention : FCR disposes of an alternative solution called TFERS 30, that is a rectangular fire damper that keeps the same characteristics of TFER 30 but purposely conceived for fast assembly on plasterboard.

pag. C-14 4 - Horizontal slab Accessories ATF 11 24 Vdc (normally energised) interruptionelectromagnet. ATF 12 230 Vac (normally energised) interruptionelectromagnet. ATF 13 24 Vdc (normally de-energised) launch electromagnet. ATF 14 230 Vac (normally de-energised) launch electromagnet. ATF 15 Open position blade s signaling micro-interruptor (contact NA/NC). ATF 21 24 Vdc servomotor - BxH < 0,8 m 2. ATF 22 24 Vdc servomotor - BxH 0,8 m 2. ATF 23 230 Vac servomotor - BxH < 0,8 m 2. ATF 24 230 Vac servomotor - BxH 0,8 m 2. ATF 31 Hatch 140 mm with gasket. Position: upper (kinematic mechanism side). ATF 32 Hatch 140 mm with gasket. Position : opposite side to kinematic mechanism. ATF 33 Hatch 140 mm with gasket. Position : lower (kinematic mechanism side). ATF 34 Fixing brackets (4) for assembly on plasterboard. ATF 35 Plates (4) for dampers coupling (flange against flange).

pag. C-15 Aeration and hearing characteristics Correction factors DP for B 400 mm. P (Pa) 400 200 100 10 80 60 40 20 1 8 6 4 2 B=400 mm 30 H=200 250 300 350 400 2 3 4 5 6 7 8 9 1 10 v (m/s) 35 40 45 50 55 500 600 700 800 60 db A B (mm) DP/DP B400 B (mm) DP/DP B400 200 1,7 900 0,7 250 1,4 950 0,6 300 1,2 1000 0,6 350 1,1 1050 0,6 400 1,0 1100 0,6 450 0,9 1150 0,6 500 0,8 1200 0,6 550 0,8 1250 0,6 600 0,8 1300 0,6 650 0,7 1350 0,6 700 0,7 1400 0,6 750 0,7 1450 0,6 800 0,7 1500 0,6 850 0,7 Key to symbols v DP L WA Speed = Capacity/gross section BxH (m/s) Open damper pressure drop (Pa) Pressure sound level weighted A (db A - rif. 10-12 W) v L WA - spectral correction - (db A ) (m/s) 63 125 250 500 1K 2K 4K 8K 2 25 9 2-4 -9-17 -32-19 3 20 8 1-4 -8-14 -27-22 4 15 6 1-4 -7-11 -22-24 5 11 5 0-4 -6-8 -18-26 6 9 4-1 -4-5 -7-15 -25 7 8 4-2 -5-5 -7-14 -22 8 7 4-3 -5-5 -6-13 -21 9 7 4-3 -6-5 -6-12 -20 10 7 3-3 -6-5 -6-12 -19 Add algebrically to value L WA resulting on diagram (correcting if B 400 mm.), in order to obtain sound power spectrum. Correction factors L WA for B 400 mm. B (mm) DL WA (db A ) B (mm) DL WA (db A ) 200 3,3 900 1,9 250 2,3 950 2,0 300 1,4 1000 2,1 350 0,6 1050 2,2 400 0,0 1100 2,3 450 0,3 1150 2,4 500 0,6 1200 2,5 550 0,8 1250 2,6 600 1,0 1300 2,7 650 1,2 1350 2,8 700 1,3 1400 2,8 750 1,5 1450 2,9 800 1,6 1500 3,0 850 1,8 Example Consider a rectangular duct with dimensions BxH = 800x400 mm, which crosses a rigid wall REI 120, through a fire damper TFER 30. The capacity in the duct is supposed to be 5000 m 3 /h. It would results : v = 5000 / (3600 * 0,8 * 0,4) = 4,3 m/s DP = 0,7 * 25 18 Pa L WA = 1,6 + 42 44 db A

pag. C-16