CALEFFI. Modulating temperature regulating unit with distribution kit for primary circuit. 171 series 01153/15 GB. replaces 01153/07 GB

Similar documents
CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.

CALEFFI. Direct supply unit for heating systems. 165 series 01237/17 GB. replaces dp 01237/15 GB. Function

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/18 GB. replaces 01260/14 GB

CALEFFI. Motorised temperature regulating unit for heating and air conditioning systems WYP UPM series 01254/17 GB

CALEFFI. Composite manifolds specifically designed for radiant panel systems. 670 series 01126/18 GB. replaces dp 01126/11 GB.

CALEFFI. Ball shut-off valve fitted for integrated flow rate measuring sensor. 111 series 01234/13 GB. (kpa) (mm w.g.) G (m 3 /h)

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS

FLOW RATE STATIC BALANCING Valves for radiators

CALEFFI. Pre-assembled distribution manifold for radiant panel systems S1 series 01144/11 GB. Replaces 01144/07 GB.

CALEFFI. Manifolds in composite specifically designed for radiant panel systems. 670 series 01126/05 GB. Function

ACCREDITED. brass EN CW617N brass EN CW614N brass EN CW614N, chrome plated PTFE PSU EPDM

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components

CALEFFI. Motorised ball zone valves with 3-contact control BY series 01131/18 GB. replaces 01131/11 GB

CALEFFI. Mixing valves and actuators series 01169/17 GB. replaces dp 01169/09. Function

CALEFFI. Hydraulic separator-manifold SEPCOLL. 559 series 01084/16 GB. replaces dp 01084/13 GB

CALEFFI. Pressure independent control valve (PICV) 145 series 01262/14 GB B 51

Pre-assembled distribution manifolds for radiant panel systems

Connection and regulation kit for HVAC terminal units

CALEFFI. Pre-assembled distribution manifolds for radiant panel systems. series 663 & /05 NA. Function

THERMOSETTER Recirculation thermal balancing valve

Pressure Independent Control Valve

CALEFFI. Motorised ball valve for central heating systems. 638 series 01196/18 GB. replaces dp 01196/12 GB

CT3202.0_01 EN February 2018

WAY MOTORISED COMPACT ZONE VALVES

Components for central heating

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Operating principle Application diagram. Regulator-actuator Wiring diagrams

548 hydraulic separator

Technote. Frese OPTIMIZER - pressure independent 4-pipe coil control unit. Application. Benefits. Features.

FO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com

SINGLE MANIFOLDS TECHNICAL DATA SHEET10/ ENG

MOTORISED BALL VALVE. Uni/Bi-directional. patented. 3 points 2 points Price list root SR... SS... SY... Connection with ball valve.

Application technology, 5th edition. Volume III: Fonterra radiant heating and cooling

CALEFFI. QuickSetter Balancing Valve with flow meter. Installation Tip

Preassembled fixed-point control, distribution and pumping unit for radiant panel heating systems DOMORADIANT Series

Art.918C Pre-assembled manifold with flow meters, air

Fan-coil valves Series

80% Max working pressure: Max working temperature: 70 C. Flow-meter regulation range: Flow meter-regulation range: ± 10%

T2 Wall Hung Radiator & UFH Manifolds

DISTRIBUTION GROUP WITH THERMOSTATIC REGULATION. Upper connections G1 F Without fittings Fittings with running connection* Without pump

Preassembled manifolds with flow meter, series CPRFL

CALEFFI. HydroMixer motorized temperature mixing unit. 167 series 01239/13 NA. Function

Technote. Frese OPTIMA - Pressure independent control & balancing valve. Application. Features. Benefits.

three-way mixing valve

Technote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits.

1 DESCRIPTION 2 WORKING PRINCIPLE 2.1 REGULATION ST

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

Terminator PICV. Technical Manual

Characterized Port -CP Three-Way Ball Valves

2-Way & 3-Way Non Spring Return Characterized Ball Valves

VP1000. Pressure Independent Control Valve. Product Bulletin

VE-S_15-32 Pressure Independent Balancing & Control Valves

PRE-ASSEMBLED MANIFOLD KIT 1 TECHNICAL DATA SHEET 10/ ENG

savings flexibility recyclable LIGHTNESS FULL FLOW MECHANICAL STRENGTH IMPROVE CONTROL TECHNICAL BROCHURE aesthetic performance CHANGE

Rod thermostat with micro switch

CALEFFI. Motorized ball valves with 3-wire control series ACCREDITED 01131/13 NA. Replaces 01131/07 NA

2-position electric actuators with Ball valves VBZ ½...11/4

Safety cap. Measuring probe. Seal. Operating principle. Advantages of balanced circuits. Balanced circuits have the following principal benefits:

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

2-Port and 3-Port Zone Valves & Actuators, PN16

STAF, STAF-SG. Balancing valves PN 16 and PN 25 DN

FCU Floor Control Unit

2-Port and 3-Port Zone Valves, PN 16 / 20

ZONE CONTROLE / 2-WAY

Vacuum pump system type

Flow controller with integrated control valve (PN 16) AHQM return and flow mounting

CALEFFI. FLOWCAL Automatic flow balancing valve with polymer cartridge. 121 series 01141/11 NA. Function

CV 206/216/306/316 GG. Standard control valves 2- or 3-way, DN , cast iron

5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO #1, #2, #3, #4 Steel reinforced main seals

Servo-operated 2/2-way solenoid valves Type EV220A

k VS DN (mm) Connections ( C) (m 3 /h)

LK Manifold Shunt VS 2-2,5

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

2/2 Pressure operated valves

underfloor heating PRODUCTS FOR UNDERFLOOR HEATING

V9000 PICV Pressure Independent Control Valve

Differential pressure controller (PN 16, 25, 40) AFP(-9) / VFG 2(1) return and flow mounting, adjustable setting

Transmitters: Relay Valve VR4151/4152

PRE-ASSEMBLED MANIFOLD KIT 1 TECHNICAL DATA SHEET 09/ ENG

CALEFFI. Solar pump stations 01166/14 NA. 278 and 279 series 01264/16 NA

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

Pump Stations for Heating Circuits

MVD, MV, MKV, MKL, 2161C, MXV Series

STAF, STAF-SG. Balancing valves PN 16 and PN 25 DN

STAINLESS STEEL MANIFOLDS FOR RADIANT SYSTEMS CREATION AND DIFFUSION OF THE STAINLESS STEEL MANIFOLD USE DIAGRAMS OF STAINLESS STEEL MANIFOLDS

Section 20. HVAC Valves & Products

STAF-SG. ANSI flanges. Balancing valves DN

599 Series Zone Valve Bodies:

V200 V200. Control on water, proportional integral. Simplified Master / Slave operation GENERAL DESCRIPTION

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

TECHNICAL CATALOGUE DISTRIBUTION MANIFOLDS

BUTTERFLY VALVES + SA ACTUATOR

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG

Ultrasonic filling level sensor UFM 200 / 600 C2 / C4 / R / MD

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control

VALVE FEATURES AVAILABLE MODELS LIMITS OF USE IP 67

Transcription:

ACCREDITED Modulating temperature regulating unit with distribution kit for primary circuit 7 series ISO 9 FM 6 / GB replaces /7 GB Function The temperature regulating unit with the distribution kit for the primary circuit is made to be used in mixed systems: radiant panels and radiators or fan coils, in combination with distribution manifolds for radiant panels. The modulating temperature regulating unit, complete with digital temperature regulator, controls the temperature of the medium sent to the panels according to the actual thermal load. In this particular series, the temperature is regulated by a dedicated hydraulic unit equipped with a specific motorised three-way valve. The function of the kit is to distribute a portion of the medium flowing from the primary boiler circuit to the heating elements. It is supplied with manifolds with built-in shut-off and balacing valves and a differential by-pass kit for the primary circuit. This accessory is essential when there is a primary circuit circulation pump and the radiator circuits or fan coils are controlled by thermostatic or thermo-electric valves. Reference Documentation - Tech. brochure Pre-assembled distribution manifolds for radiant panel systems 668...S series Product range Code 7.AL Modulating temperature regulating unit with distribution kit for primary circuit, with ALPHA L -6 pump Technical specifications Performance Materials Regulating unit with motorised three-way valve brass EN 98 CB7S Headwork: brass EN 6 CW6N Obturator: stainless steel EN 88- (AISI Seals: EPDM Flow adapter unit brass EN 98 CB7S Primary circuit by-pass kit brass EN 98 CB7S By-pass valve: PA6G Spring: stainless steel EN - (AISI ) Shut-off valves brass EN 6 CW67N Ball: brass EN 6 CW6N, chrome plated Primary circuit distribution manifolds Flow manifold brass EN 98 CB7S Flow rate regulating valve Obturator: brass EN 6 CW6N Hydraulic seals: EPDM Return manifold brass EN 98 CB7S Shut-off valve Stem: stainless steel EN 88- (AISI ) Obturator and seals: EPDM Springs: stainless steel EN - (AISI ) Control knob: ABS Medium: water, glycol solutions Max. percentage of glycol: % Adjustment temperature range: 78 C Primary inlet temperature range: C Max. working pressure: kpa ( bar) Min. working pressure: 8 kpa (,8 bar) Panel manifolds differential by-pass setting: kpa (. mm w.g.) Primary circuit differential by-pass setting: kpa (, m w.g.) Primary circuit manifold inside diameter: Ø 7 mm Temperature gauge scale: 8 C Pressure gauge scale: bar Connections: - primary circuit: / M (ISO 8-) - to regulating unit: F (ISO 8-) with nut - panel circuit outlets: / M - Ø 8 mm - outlet centre distance: mm - primary circuit manifold outlets: / M - Ø 8 mm - outlet centre distance: mm Panel circuit differential by-pass graph Δp (mm w.g.),,, Δp (kpa) Flow rate (l/min) (m /h)

bar 6 con forme norm e CL. ISPE S L 6 8 C 6 8 C CAMERA CALEFF Digital regulator Three-point type Electric supply: V - /6 Hz Power consumption: VA Protection class: IP Actuator Three-point type Electric supply: V - /6 Hz Operating time: s (rotation ) Power consumption: 8 VA Auxiliary micro contact rating:,8 A Protection class: IP Max. ambient temperature: C Protective cover: self-extinguishing VO Head available at the regulating unit connections H (m w.g.) 6 (kpa) 6 Flow/return temperature probes NTC type Working range: - C Time constant:, s Response:. Ω at C Two-wire cable with /8 M connection Maximum temperature safety thermostat Factory setting: C ± C Protection class: IP Contact rating: A / V Minimum temperature safety thermostat Factory setting: C ± C Protection class: IP Contact rating: A / V Pump High-efficiency pump: model ALPHA L -6 cast iron GG / Electric supply: V - /6 Hz Maximum ambient humidity: 9% Max. ambient temperature: C Protection class: IP Pump centre distance: mm Pump connections: / F (ISO 8-) with nut Note:,,,6,8,,,6,8, G (m /h) The pump can operate with constant or proportional pressure control which adapts the performance to the system requirements. For further details, see the pump installation instruction sheet supplied in the package. Insulation Material: closed cell expanded PE-X Thickness: mm Density: - inner part: kg/m - outer part: kg/m Thermal conductivity (DIN 6): C:,8 W/(m K) C:, W/(m K) Coefficient of resistance to the diffusion of water vapour (DIN 6): > Working temperature range: C Reaction to fire (DIN ): Class B Dimensions outlets 8 outlets outlets 8 9 / A A A Code Radiator outlets Panel outlets A 7EAL 7FAL 7GAL 7HAL 7IAL 7LAL 7MAL 7NAL

Characteristic components Digital regulator for heating Three-way mixing valve Three-point actuator High-efficiency pump, ALPHA L -6 Flow temperature probe 6 Return temperature probe 7 Adjustable drain cock 8 Safety thermostat 9 Flow and return temperature gauges with pocket Pressure gauge Primary circuit shut-off valves Distribution manifolds with built-in valves for primary circuit Primary circuit differential by-pass kit Hydraulic diagram BF RT 9 7 ST 8 6 9 SF SR RT ST Digital regulator Adjustable drain cock Temperature gauge Temperature probe Room thermostat Safety thermostat Ball shut-off valve Motorised three-way valve Pressure gauge Pump BR Differential by-pass

Operating principle The medium temperature is regulated by a three-way mixing valve with a sector obturator comprehensive of an actuator managed by a specific digital controller. The controller receives the signal from two probes, flow probe on the mixing valve outlet and probe from the panel circuit return, and it controls the movement of the valve. The flow in the valve is regulated by a shaped obturator () that, by turning, closes or opens the hot water flow ports () and the water returning ports from the circuit () to adjust the desired flow temperature. Even if the secondary circuit thermal load or the inlet temperature from the boiler change, the mixing valve automatically adjusts the flow rates until it obtains the optimal flow temperature. PRIMARY INLET SECONDARY FLOW PRIMARY RETURN SECONDARY RETURN Construction details Regulating unit body The valve body, containing the thermal regulating device, is made out of a single casting with connections to the primary and secondary circuits. A specific internal channel carries the system return medium to the regulating valve, making it possible for the unit to be smaller in size and easy to connect. Flow unit The flow unit is made out of a single casting with the necessary ports to connect with the functional components such as the safety thermostat, temperature gauge, pressure gauge, drain valve and flow temperature probe. Reduced head losses The three-way mixing valve is equipped with a special obturator acting on calibrated water orifices. This ensures a high flow rate and a reduced size, while maintaining accurate temperature control, with no swinging due to sudden changes in thermal load. Electrical connections The actuator is electrically connected through an external plug-socket system with a protective rubber cap. This system does not require opening the lid to connect the cables. In this way, replacing the actuator (should this ever be necessary) is particularly easy to do. ϒC 6 8 Manual opening By removing the actuator, the valve can be opened-closed manually by using a screwdriver. Regulating way - primary inlet Fully closed Fully open open c l o s e open l o s e c

Distribution and differential by-pass kit for primary circuit Operation The distribution and differential by-pass kit for the primary circuit enables controlling the flow supplied to the heating or cooling elements connected before the outlet to the panel circuit regulating unit. It is composed of distribution manifolds with built-in regulating and shut-off valves, and the differential by-pass kit for the primary circuit. Primary circuit distribution manifolds The distribution manifolds are equipped with: - flow rate regulating valves built into the flow manifold. In this way it is possible to set the right flow rate and balance the various connected circuits. - shut-off valves built into the return manifold. The same circuits can be automatically shut off by using the thermo-electric controls. Δp (mm w.g.) 9 8 6 8 6 9 8 6 8 6,,, Flow rate regulating valve fully open Shut-off valve - Kv = flow rate in m /h for a loss of head of bar - Kv, = flow rate in l/h for a loss of head of kpa Kv,, Δp (kpa) 9 8 7 6,,,,8,6,,,9,8,7,6,,,,,,8,6,, Kv,,,, Flow rate (l/min) (m /h) Hydraulic characteristics of flow rate balancing valve Adjustment position turns turns turns Differential valve The differential valve is used to control the head in the primary distribution circuit. It aids the flow circulation towards the heating elements and limits overpressure if there are thermostatic or thermo-electric valves. The differential valve setting can be adjusted. It is preset to kpa, the mean value for the loss of head in the primary circuit. If necessary, the trigger value can be adjusted within the range kpa (, m w.g.), using the corresponding knob with graduated scale. Δp (m w.g.) Kv (m /h),,, turns, F.O.,, Kv, (l/h),,,,,,7 mm (kpa) Flow rate (l/min) (m /h) Primary circuit by-pass kit The by-pass kit permits hydraulic separation between the primary and secondary circuits. This hydraulic separation optimizes the operation of the secondary circuit at the panels thus preventing the influence on the secondary circuit by any primary circuit flow rate variation. In this case, the flow rate through the respective circuits depends solely on the pump flow rate characteristics, preventing reciprocal influence due to their coupling in series. Two possible conditions of hydraulic balance are described here. The component is typically sized in order to have the following working rate: G primary = G secondary (inlet to the mixing valve) + G heating elements G primary maximum recommended:, m /h Secondary Gs Secondary Gs Gp Primary Gp Primary Gprimary > Gsecondary Gprimary < Gsecondary

Digital regulator 7 8 Operation The regulator receives the signal from the room thermostat to switch the pump on and to control the mixing valve. The regulator acts on the mixing valve following two operating logics, depending on the state of activation of the return sensor. Set point regulation: return probe off. Selector 6) OFF. In this case the flow temperature FT is kept constant at the value set with the selector ) in both heating and cooling. This setting is shown on the display ). Modulating regulation: return probe on. Selector 6) ON. In this case the flow temperature FT is changed according to the temperature measured by the return probe RT. In this way the actual thermal efficiency of the slab is kept under control and, as a result, the room s thermal load as well. This minimizes the system s thermal response times. RT set = FT set - % (FT set - C) FT calculated = FT set + (RT set - RT) Example: FT set = C RT set = -, ( - ) = C FT calculated = + ( - RT) 9 6 The front panel identifies the following functions: ) Three-digit LCD indicating: the measured or calculated temperature and the settings of the delays programmed in the system. Temperature range displayed: 99 C with resolution, C. ) Regulator ON/OFF function selector. ) Mixer on opening: LED on. ) Mixer on closing: LED on. ) Selector for setting the flow temperature. Temperature range 7 78 C Factory configuration: - heating: max C - cooling: min C 6) Return probe selector. Probe off: OFF Probe on: ON Factory configuration: ON 7) Pump working (ON): LED on steady. 8) T.S. LED safety temperature. Continuously ON when the limit signalled by the safety thermostat or by the safety humidostat is reached. Continuously ON even if the flow/return sensors malfunction (see flow/return sensor paragraph). 9) Heating/cooling function switch The new value of FT calculated is shown on the display ) with a side bar. At each update of the FT calculated, the FT measured is displayed for s, thereafter the new FT calculated is shown again. FT modification stops when RT reaches RT set. The return probe is not active in the cooling function. Curve correction graph with return probe FT;RT ( C) Designed flow temperature FT Set FT Calculated RT Set FT Calculated Return temperature designed Flow temperature limit FT Flow temperature ) Trimmer for maximum pulse duration on the valve. Adjustable, 6 s. Factory configuration:, s. Pulse value calculation: % % % Designed thermal load % Tpulse (s) = Example: Tactuator rotation = s Tpulse = / = s Actuator rotation time (s) ) Return probe reading delay time trimmer. Adjustable 6 s. Factory configuration: s. ) Valve-motor mechanical delay recovery trimmer. Adjustable s. Factory configuration: s. Display The three-digit LCD displays the following parameters: - flow temperature set with selector ). After s the measured flow temperature appears. - measured flow temperature, with return sensor off. - calculated flow temperature, with return sensor on. - maximum duration of pulse on the valve, selectable via trimmer ). Displayed for s. - return temperature acquisition delay time, selectable via trimmer ). Displayed for s. - valve-motor mechanical delay recovery, selectable via trimmer ). Displayed for s

Back panel M V~ 6 Hz ~ μ () A / V~ 6 6 6 7 8 L N SA SR TA TS V~ IN OUT Apre Chiude 6 7 8 7 8 9 7 8 9 On the back panel there are terminals for the electrical connections of the various components. Electric supply Electric supply V~ Live Electric supply V~ Neutral Ground/Earth Pump command Ground/Earth Pump command V~ Live 6 Pump command V~ Neutral Mixer command 7 Valve command for opening 8 Common C 9 Valve command for closing Heating safety thermostat If the safety thermostat trips, on detecting a higher flow temperature than the setting, the following state comes into operation: pump OFF, mixing valve closed. The thermostat contact is N/C; if the connection fails, the regulator is not on. Auxiliary microswitch The regulator is equipped with an auxiliary microswitch that can be used to control other devices. Example: When Heating, to turn the water heater on/off. N/O contact - Pump stationary - ambient thermostat OFF or safety thermostat on (water heater off). N/C contact - Pump on - ambient thermostat ON (water heater on). Contact capacity: A ( V). Flow/return probe The flow/return temperature probes are the NTC type. If the probes detect an ohmic resistance corresponding to short circuiting, the following operating state comes into operation: pump OFF, mixing valve closed, LED 8) on steady. Sensor resistance values table - 97.6-7.9 -.9 -..6.96 9.9.7.9. 8.6 6..7..6.986 6.88 6.8 Flow temperature limit for heating The regulator enables selecting the maximum flow temperature for heating. For this purpose, the regulator base contains specific dipswitches that enable setting different temperature limits. Factory configuration: - heating max C..7 7.8 8. 8. 9 9 9 787 68 9 7 9 Auxiliary microswitch Auxiliary output N/O Auxiliary output common C Auxiliary output N/C Flow/return probe Flow temperature probe Common C Return temperature probe Ambient thermostat/safety thermostat 6 Contact for ambient thermostat 7 Contact for common C ambient thermostat / Contact for common C safety thermostat 8 Contact for safety thermostat Dipswitch position-temperature limit table Setting Limit Dipswitch maximum 8 6 66 7 78 ON Position Position Accessories 78 Digital room chrono-thermostat. operating programmes with ON/OFF spark advance. Weekly programmable clock. Fitted for phone programmer. Three temperature levels + anti-freeze. -minute minimum programme. ON/OFF function with adjustable differential from, to C or proportional. Adjustable temperature with, C steps. SUMMER/WINTER switch. changeover switch output contact: 8 () A. Protection class: IP. Code 787 787 787 x 8 x 9 mm x 8 x 9 mm x 8 x 9 mm battery supply electric supply V built-in GSM module - supply V

bar 6 6 8 ϒC c on f or m eno r me I SP CL. ESL 6 8 ϒC CAMERA CAMERA CALEFF Application diagram Pump Thermostatic valve Manual valve Lockshield Shut-off-valve Clock RT Room thermostat RT SPECIFICATION SUMMARIES Code 7.AL Modulating temperature regulating unit with distribution kit for primary circuit. Connections to the primary circuit / M (ISO 8-). Connections to the regulating unit F (ISO 8-) with nut. Panel circuit outlet connections / M - Ø 8 mm. Primary circuit manifold outlet connections / M - Ø 8 mm. Medium: water and glycol solutions; maximum percentage of glycol %. Adjustment temperature range 78 C. Temperature range at primary circuit inlet C. Maximum working pressure kpa ( bar). Minimum working pressure 8 kpa (,8 bar). Panel manifolds differential by-pass setting kpa. Primary circuit differential by-pass setting kpa. Temperature gauge scale 8 C. Pressure gauge scale bar. Complete with: flow manifold for panel system with outlets (from to ) with brass body, flow rate regulating valve with flow meter with a scale of l/min; return manifold for panel system with outlets (from to ) with brass body, shut-off valve. Regulating unit with motorised three-way valve, three-point actuator, electric supply V - /6 Hz, protection class IP. Digital regulator, electric supply V - /6 Hz, complete with probes measuring temperature of flow and return. Flow adapter unit with brass body. Primary circuit distribution manifolds with outlets, brass body, flow rate regulating and shut-off valves. By-pass kit with brass body, PA6G differential by-pass valve and stainless steel spring. Shut-off valves with brass body and chrome plated brass ball. Maximum temperature safety thermostat: factory setting C ± C; minimum temperature safety thermostat: factory setting C ± C, protection class IP, contact rating A / V. High-efficiency ALPHA L -6 pump, protection class IP. Pre-formed PE-X shell insulation for primary circuit. Supplied preassembled in a painted plate box with lock, depth adjustable from to mm, including floor supports adjustable in height from to mm. We reserve the right to make changes and improvements to the products and related data in this publication, at any time and without prior notice. Caleffi S.p.A. S.R. 9 n. 8 Fontaneto d Agogna (NO) Italy Tel. +9 89 Fax +9 867 info@caleffi.com www.caleffi.com Copyright Caleffi