Operation Manual Image

Similar documents
Operation Manual. Foto-Flo 44

Operation Manual. Flathead 80 System

Operation Manual Mega. 4Bank, Double & Single

Operation Manual. 12V Single Kit

Operation Manual. Mega 4Bank DMX Universal

Operation Manual. Select/DMX 4Bank

Operation Manual. 4Bank, Double & Single

The 4-Lamp Mega Fixture Built-in Barndoors Removable Reflector, Louver and Lamp Harness Twist-on Locking Center Mount True Match daylight, tungsten

DMR 3005 WM ONE ZONE WIRELESS DIMMER RECEIVER

Install Guide PMX SERIES PENDANT MOUNTED MATRIX SP1 STYLE

1.4 N/1.4 D. Operating Instructions. 580 Mayer Street, Building #7, Bridgeville, PA phone fax

Compact LED profile with zoom

PRODUCT MANUAL Gecko Wireless One Zone LED Dimmer and Receiver

Operation Manual. Kino Flo/BlockBattery

LED GEL MOUNTED FRAME

SURFACE TRACK (120/250V) SPECIFICATIONS

ELS Electronic Lighting System

OFFICE PARTITIONS. Data Port Openings. Use cable tie bracket to dress data cables under panels. STEP 1

INSTALLATION AND CUSTOMER CARE INFORMATION 80 SERIES & 90 SERIES TREATMENT STATIONS

DESIGNER SERIES HINGED GLASS PANEL, GRILLE, BLIND AND SHADE INSTRUCTIONS

LSI 20 Series 30A, 120V Surface Busway Components 1

Page 1 of 5 FL-4020 FLUORESCENT BALLAST CONTROLLER

OEM TM-50 Quick Start Guide

PRODUCT MANUAL Gecko Wireless 2 Zone LED Dimmer and Receiver

Anthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A

ARRI EVENT SYSTEM. Best in Show

Installation Instructions

UCA ADJUSTABLE ANGLE MULTI COLOR TEMPERATURE

INSTALLATION GUIDES OUTDOOR LIVING

Base Power Infeed Installation for Training Tables with Modular Table Power System

TOYOTA RAV4/HV INTERIOR LIGHT KIT Preparation

RECESSED TRACK (120V) SPECIFICATIONS

EMERY SKY SUSPENDED LED LUMINAIRE

ATTACH YOUR RECEIPT HERE ITEM # FT. PRE-LIT DOUGLAS FIR TREE. MODEL #DF-75C85 Español p. 8

Universal Super Shield & Ultimate Aluminum w/electric Drive Conversion Kits , , Installation Instructions

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

NT-300 Series Single Circuit Track System & Accessories

PRODUCT MANUAL Desktop LED Dimmer and Receiver

PRODUCT MANUAL Onyx 2 Zone In-Wall Wireless LED Dimmer and Receiver

Installation Instructions

Measurements are expressed in millimeters.

USER S MANUAL TUBE SEALER. Model SE250. No. CAT.SE25010Ce

WAVELIGHT -2 USER INSTRUCTIONS. Description:

Installation Instructions

To Purchase This Item, Visit BMI Gaming

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

ILLUMINA BS100 INSTALLATION INSTRUCTIONS FLUORESCENT VAPOR TIGHT

HLS Watt Halogen Illuminator Service Manual

PARTS AND SERVICE MANUAL

LAMPS 8L - 1 LAMPS CONTENTS

2005 and 09 Mustang install instructions Sequential / Chase Unit Partial Plug-N-Play Kit Meter4it Eng. Updated: 3/28/09

ECO-T LED RECESSED TROFFER USER MANUAL

HPNLS-HO. Installation Manual

Wireless Dimmer Installation and User Guide

1Unpack fixture. Suspensions/canopies are ordered and

Special Note About The JDM High Performance Water Pump:

Installation Instructions

Lighting Systems Argus-7

NULB-8 Series silk sbc led lightbar 24V LED Light Bar Source: 5W / 350Lumen / 90+CRI per ft

Lamp: K-2200K K-2200K

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

install o IIVIPORTANT - Savethese -&WARNING - -&WARNING - This appliance must -&WARNING - Before beginning the Mode_s PB970, PB975

Outdoor Installation Using an Electronic LED Power Supply (TE-60L-12)

LED Trouble Light / Hand Lamp / Drop Light -10 Watt LED Bulb - 12 Foot SJOW Cord

Portable Lighting Equipment Operating Instructions Table of Contents

INTEGRID TRACK (120V) SPECIFICATIONS

I1 7.5 Pre-Lit Clear Christmas Tree

EnDuraLast II Charging System Installation Guidlines

5 Million Candlepower Handheld Spotlight- Red Hunting Lens Watt Halogen - Spot/Flood Combo

1000 DE BOSS. Installation & Operating Instructions COMMERCIAL FIXTURE READ THESE INSTRUCTIONS BEFORE FIRING UP YOUR BALLAST

Museum Alkmaar - Alkmaar, Netherlands

One- Touch Installation Instructions

Stand Alone Kit Installation Instructions

CHAPTER S e t u p NOTICE:

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

If You Are Experiencing This, Click Thru:

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

SPECIALTY LAMPS INCANDESCENT SCARE LAMP LED UTILITY/INTERIOR LAMP SAND DOLLAR FEATURES:

STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

2000 Watt Telescoping Light Mast - 30' 3-Stage Light Tower Rotating Boom - High Mast Lighting

1718 W. Fullerton Ave Chicago, IL Tel: Fax:

Use Littlites anywhere you need a little light! Gooseneck Lamps & Accessories

Specular louver Semispecular. PRF Perforated Top Cover SLD Solid Top Cover. louver. FUS GLR fuse for each ballast

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

Automatic Butter Dispenser Instruction Manual Model #2395NS

HP10134 & HP10135 KITS BASIC SIMULTANEOUS AIR SPRING ACTIVATION KIT

Part No. PAFULAxxx. Figure 2

Ara 4. Mounting and installation instructions. Item no.: Ara K black. User manual

DRYING SYSTEM ASSEMBLY AND OPERATING MANUAL

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

Ichip Mystére LED FOLLOWSPOT USER MANUAL

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

MIDTOWN INSTRUCTIONS. White, Silver, Black. Single Light. MIDTOWN LED Recessed Light Installation Guide LED RECESSED LIGHT. (The nuts & bolts)

Source: 81.68LM per foot, 1.3 W per foot

Designed for 2015 Ford F150 Super-Cab and Super-Crew vehicles (Compatible in vehicles with or without Sony System. M6 Bolt X 2

INSTRUCTION MANUAL. All PrimeTime Studio Lights are equipped with advanced reflector technology.

NULB-5 Pro90 Series ILLUMINATING THE FUTURE...SINCE Ultra-Low Profile Linear LED Lightbar PLUS. Type Project Catalog No.

ALD Dimmer Enclosures

INSTALLATION INSTRUCTIONS

L-801 HBM 150/2 Airport Rotating Beacon Compliant with Standards: FAA: L-801 AC 150/ (Current Edition) ICAO: Annex 14, para 5.3.

Transcription:

Operation Manual Image 82, 42, 22 4/14/03

Image 82 8 x 4ft lamps Manual on/off switching control Switches 2 lamps at a time Image 42 4 x 4ft lamps Manual on/off switching control Switches 2 lamps at a time Image 22 4 x 2ft lamps Manual on/off switching control Switches 2 lamps at a time Each System Includes: 1 Image Fixture 1 Silver Louver 1 Gel Frame 2

Insert lamps into both lamp connectors. Twist ¼ turn to make electrical contact. The gel frame is secured to the fixture by 4 spring-loaded pins. Align the pins of the gel frame with the oval receptacle holes on the edge of the fixture. Pull back the pins and release into the receptacles to properly secure the gel frame. A) The Gel Frame comes with Gel Clips. Cut the gel to size and use the Clips to fasten the gel to the Frame. (A) (B) B) Another method is to apply transfer tape directly to the gel frame. The clips are not necessary when taping the gel. 3

Place the long edge of the Louver into the lower channel containing a set of leaf springs. Press down on the Louver and slip the upper edge of the louver into the upper channel of the fixture. To remove reverse the procedure. The Image 82 requires a Junior Pin assembly or any other clamping device that uses a ½ inch bolt. Junior Pin Assembly The Image 82 uses the longer bolt. The Image 42 and 22 require the shorter bolt. The Baby Receiver is for use only on the Image 42 and Image 22. Baby Receiver Assembly Do Not use the Baby Receiver on the Image 82. This receptacle is not strong enough to safely hold the greater weight of the Image 82. 4

The Image 82 Fixture is used for example purposes throughout these instructions. A B A ) Power Switch: Has a built-in indicator light, which can detect if AC power is present in power cord. "O" = OFF position B ) Fuse: Provides circuit protection. Note: If Fuse is blown or open replace with same type of fuse rating as marked. Provide 120 Volt AC primary power. Do not dim the fixture through a dimming circuit. If powering the fixtures through a dimmer board, set the dimmer profile to non-dim. Load Considerations: Kino Flo ballasts are not power factor corrected. They will draw double the current on the neutral from what is being drawn on the two hot legs. On large installations it may be necessary to double your neutral run so as not to exceed your cable capacity. 5

IMAGE 82, 42 and 22 Fixtures are operated manually with the Lamp Switches. The Switches enable you to turn lamps on and off with an inside-out pattern Image 82 Switching Pattern Image 42 and 22 Switching Pattern 6

LVR-I80-B Image 82 Black Louver MTP-I80 Junior Pin for Image 82 Image 42 and 22 MTP-I40 Baby Receiver for Image 42 and 22 BRD-I80 Image 82 Barndoors, Set of 4 BRD-I40 Image 42 Barndoors, Set of 4 BRD-I20 Image 22 Barndoors,Set of 4 7

Side Door X2 Top and Bottom Door 1. For the Side Doors, align the hinge bracket tabs with the two square receptacles on the side of the fixture. 2. Press the tabs of both brackets into the square receptacles. 3. Slide the two brackets up until the silver lock pin snaps into place. 4. To release the Barndoor, press the Lock Pin down and slide the bracket in reverse. 8

1. For the Top and Bottom Doors, align the two hinge bracket tabs with the two square vents closest to the Silver Lock Pins. 2. Press the brackets down into the vent and slide them over to engage the Lock Pins with the hole in the bracket. 3. To remove the Barndoor, press down on the two Lock Pins and slide the brackets back. Adjust the hinge tension with a Philips head screwdriver. 9

Kas-I80-1 Kas-I80-2 KAS-48 Part Description Dimensions Weight Holds Number (Empty) KAS-I80-2 Image 82 Ship Case 56.25 x 16.25 x 35 98 lb / 44Kg Image 82 x 2 1435mm x 413mm x 889mm 8KAS-I80-1 Image 82 Ship Case 56.5 x 7.75 x 35 38lb / 17Kg Image 82 x 1 1435mm x 197mm x 889mm KAS-I40-1 Image 42 Ship Case 56.5 x 10.25 x 23.25 29lb / 13Kg Image 42 x 1 1435mm x 260mm x 590mm KAS-I20-1 Image 22 Ship Case 31.25 x 10.25 x 23.25 18lb / 8Kg Image 22 x 1 794mm x 260mm x 590mm KAS-48 4ft Lamp Ship Case 52.5 x 10.5 x 11.25 15lb / 7Kg 4ft T12 Lamps(20) 1333mm x 267mm x 286mm Model: Image 82 Power requirements: 120VAC or 230VAC Amperage: 10 amps at 120VAC, 5 amps at 230VAC Weight w/lamps: 37lb / 16.7Kg Dimensions: 54.5 x 32.63 x 6.25 1384mm x 829mm x 159mm Lamp Switching: 8 / 6 / 4 / 2 / Off Lamp types: F40T12 10

Model: Image 42 Power requirements: 120VAC or 230VAC Amperage: 5 amps at 120VAC, 2.5 amps at 230VAC Weight w/lamps: 22lb / 10Kg Dimensions: 54.5 x 20.25 x 6.25 1384mm x 514mm x 159mm Lamp Switching: 4 / 2 / Off Lamp types: F40T12 Model: Image 22 Power requirements: 120VAC or 230VAC Amperage: 1.8 amps at 120VAC,.9 amps at 230VAC Weight w/lamps: 14lb / 6.3Kg Dimensions: 30.5 x 20.25 x 6.25 775mm x 514mm x 159mm Lamp Switching: 4 / 2 / Off Lamp types: F20T12 Kino Flo, Inc. 10848 Cantara Street, Sun Valley, CA 91352, USA Tel: 818 767-6528 website: www.kinoflo.com 11