AGD AND AGD4A SERIES

Similar documents
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

2 ½ 12. Installation, Operation, and Maintenance Manual. Reduced Pressure Principle Backflow Preventer. Reduced Pressure Detector Assembly

MAINTENANCE MANUAL. Covering Models: Series (1/4-10 ) S Series (1/4-1 ) Series (3-10 )

MADE IN THE USA BACKFLOW PREVENTERS

BACKFLOW PREVENTION CATALOG

LEAD FREE * LFF113FP. Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology. Materials NOTICE NOTICE ES--LFF113FP

2 ½ 12. Model RP 4A Model RPDA 4A Model RPDA2 4A. Installation, Operation, and Maintenance Manual

K-Rain - Hydrotek Valves Instructions

Backflow Preventers TABLE OF CONTENTS

Operating Instructions ProMinent. Backpressure and Pressure Relief Valves

4P-300 4V-500 CONTINUOUS PRESSURE THERMOPLASTIC DUAL. PRINCIPLE (U & Z Flow) DUAL CHECK VALVE. PRINCIPLE (Stn.Steel) REDUCED PRESSURE

HERSEY 6CM SIZE 2 1/2", 3", 4", 6", 8", 10"

HVAC. Products. TRI A FLO Automatic Cartridges PAGE 2. TRI Y FLO Strainer PAGE 3. TRI U FLO Accessory Union PAGE 4. CB Series Butterfly/Venturi PAGE 5

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

DCAP Series 40-4 X X - X X X. Dual Check w/ Atmospheric Port Backflow Preventers

LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

Model Performance SW VersaJet. Shut-off PSI 118 Max. Lift 90 Conv. VersaJet Pro. Shut-off PSI 111 Max. Lift 90 Pro (RM2) Series

Proposition 65 Warning This product contains chemicals known to the State of California to cause cancer or birth defects or other reproductive harm.

P200 SERIES PORTABLE HYDROSTATIC TESTER FEATURES: PUMP TYPE AND PRESSURE RANGES

Bypass / Filter Feeders Operations & Maintenance Manual

LEAD FREE * PVS-7000 Engineered Flood Protection Valve Station with SentryPlus Alert

Series 867 Reduced Pressure Zone Assemblies

Colt Series C400, C500

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.

See Water Pressure Reducing Valves Catalog (PHBRWPRV) for more detailed information about the products in this section.

Model descriptions. Technical data. Pressure and Temperature Limits Models 19, 20, 20P: -60 to 406 F Models 19M, 20M, 20MP:

See Water Gauge/Liquid Level Catalog (PHBRWGA) for more detailed information about the products in this section.

See Water Pressure Reducing Valves Catalog (PHBRWPRV) for more detailed information about the products in this section.

Low Pressure Series - Accessories. High Pressure Series - Accessories

D-26. Combination Air Valve for Wastewater. Description. Applications. Operation. Main Features

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

CARBONATORS & WATER BOOSTERS

HBT SERIES HYDROSTATIC BURST TESTER FEATURES: PUMP TYPE PRESSURE RANGES HYDROSTATIC PRESSURE GAUGE

introduction RV Series Sediment Strainers Product Data Sheet

Kunkle Models 91/218/228 liquid relief valves Safety and relief products

Kunkle Models 91/218/228 liquid relief valves Safety and relief products

Flood Control Integrated System (FCIS)

Series 995/995RPDA. Sizes: 3" - 6" Reduced Pressure Zone Backflow Preventer/ Reduced Pressure Detector Assemblies RP/IS-995/995RPDA

5600 Control Valve. Bypass Piping Boss Inlet & Outlet. Distributor Tube and basket. Brine Well. Brine Line. Over-Flow (Optional) $1.

THE DEFENDER 4D-200 SERIES

HIGH CAPACITY CENTRIFUGAL & SPRINKLER PUMPS

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

THIS WARRANTY IS IN LIEU

TEMPERATURE REGULATORS W91/W94 Series

High Pressure Ball Valves

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

High Capacity Centrifugal & Sprinkler Pumps

Close-Coupled Centrifugal Pumps 316 Stainless Steel, Bronze and Cast Iron Models

SELF-PRIMING PUMPS PRODUCT FAMILY APPLICATIONS FAMILY COMPARISON CHART

SHURflo Pedestal-Mount Centrifugal Pumps

DIGIFLO ELECTRONIC FLOWMETER

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

TECHNICAL DATA. Trimpac 244a. April 15, 2011

Control Components Pty Ltd. Drawing Number. Indicator Model Overview A 66.01A Side flanged connection

INLINE 1100 COMPACT, MULTI-PUMP SYSTEM

KUNKLE MODELS 19/19M/20/20M/20P/20MP/200A/200H LIQUID RELIEF VALVES SAFETY AND RELIEF PRODUCTS

D-023 PN 16 / 25. Combination Air Valve for Wastewater PATENTED. Description. Applications. Operation. Main Features

Water treatment services product catalog

Installation, Maintenance, & Repair Series 995 Reduced Pressure Zone Backflow Preventers

REPAIR SEALS AND OPTIONS

Overfill Prevention Valve

3. The working pressure shall be 145 psi and tested to 230 psi.

REDUCED DIAMETER SUBMERSIBLE PUMPS

Valve Accessories NEW! Wanner Engineering Inc

Pulsation Dampeners (Chargeable-Adjustable)

Valves and Equipment

Series 009. Reduced Pressure Zone Assemblies. Installation Service Repair Kits Maintenance. Sizes: 8 80mm. 80mm 009LF RP/IS-009-AUS

Installation Manual. Model # SF-4W rev.4 (02/28/14) 1200 Lower River Road, P.O. Box 800 Charleston, TN PULSAR

ASV Valves V E S A S V. Electric valve with Atmospheric Backflow Prevention For Residential Systems

Accessories. Section Outline

SHOCK BLOCKER FLUID PULSATION DAMPENERS

Reverse Osmosis Systems Section 11 Reverse Osmosis Systems

pump selection guide PONNDORF PX single series PDX single series PD/2 dual series PK series

CPPL9000 EFFECTIVE 01OCT18

F479 HVE V PARTS LIST

ABS DWV FITTINGS FOR PLUMBING AND MECHANICAL APPLICATIONS

CAUTION: NOT INTENDED FOR STREET USE HOW TO USE THIS CATALOG WE LOVE RACING

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.

4000SS. For other repair kits and service parts, send for Ames Repair Parts Price List, PL-A-RP-BPD.

Recognized globally for our quality, service and the ability to deliver! ISO 9001: Quality Service Experience

Installation, Maintenance, & Repair Series 919 and LF919

HIGH PRESSURE SPRAYERS

DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

Conrader Control Valves Technical Data

TECHNICAL DATA. Trimpac 249a. September 16, 2013

Weights: Motor... Lb Pump... Lb Extra Column... Lb

SAMPLE CYLINDERS. Sample Cylinders & Accessories. Spun End Cylinders. Ultra-Seal Constant Pressure Cylinders. VP Series Cylinder Valves

Sanitary Solutions Valves/Product Recovery System Catalog Distributed By:

INLINE 1100 COMPACT, MULTI-PUMP SYSTEM. franklinwater.com

Phone (toll-free): (888) Phone (local): (973) Fax: (973) Web:

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011

Installation, Maintenance, & Repair Series 4000CIV

1.1 PURPOSE A. This section is intended to define the general installation and minimum product requirements for hydronic and steam valves.

SHURflo Close-Coupled Centrifugal Pumps

CALL GRIFFCO CHEMICAL PUMP ACCESSORIES

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15, 20 & 25 TONS MODELS: J07 thru 25NC, 2-PIPE J10 thru 20ND, 4-PIPE

Filters & Strainers Technical Information TECHNICAL INFORMATION WEIGHTS & DIMENSIONS

Installation / Operation Manual

FIELD ADJUSTABLE REG-U-MATIC PRESSURE REGULATING VALVES

TECHNICAL DATA TRIMPAC MODEL B-4, B-4B & B-4S SINGLE INTERLOCK PREACTION SYSTEM WITH PNEUMATIC RELEASE

Transcription:

Job Name: Job Location: Engineer: Tag: AGD AND AGD4A SERIES DESCRIPTION The Apollo Air Gap Drain (AGD) is designed to funnel minor discharges from a Reduced Pressure Backflow Preventer s relief valve due to line pressure fluctuations and/or minor check valve fouling, into the drainage system. Drain piping is easily attached to the AGD s threaded bottom outlet. The AGD4A series ABS plastic AGDs have the additional option of using the outlet OD to glue on a coupling using the appropriate cement or the use of a flexible pipe coupling. Note: The AGD is NOT designed to collect the full discharge capacity of the relief valve. Please refer to the charts on pages 2 and 3 for RP Relief Valve full discharge rates. The appropriate AGD should be selected for Apollo s Reduced Pressure RP4A and RP40 Series backflow preventers from the table below. Contractor: P.O. Number: Representative: Wholesale Distributor: RP4A ½ 2 RP40 ¼ 2 RP40 2 ½ 10 RP4A Series AGD Model No. Order Code A B C OD of C D Wt.Each 1/2" AGD4A1 AGD4A1 6 1/2 3 3/8 1" FNPT 1 1/4" Pipe 2 5/8 0.1 3/4" AGD4A1 AGD4A1 6 1/2 3 3/8 1" FNPT 1 1/4" Pipe 2 5/8 0.1 1" AGD4A1 AGD4A1 6 5/8 3 3/8 1" FNPT 1 1/4" Pipe 2 5/8 0.1 1 1/4" & 1 1/2" AGD4A112 AGD4A112 8 1/2 4 1/8 1 1/2" FNPT 2" Pipe 3 1/2 0.2 2" AGD4A2 AGD4A2 10 5 3/8 2" FNPT 2 1/2" Pipe 4 1/4 0.35 RP40 Series AGD Model No. Order Code A B C OD of C D Wt.Each 1/4", 3/8", 1/2" AGD4012 AGD4012 6 1/2 3 3/8 1" FNPT 1 1/4" Pipe 2 5/8 0.1 3/4" & 1" AGD401 AGD401 8 1/4 4 1/8 1 1/2" FNPT 2" Pipe 3 1/2 0.2 1 1/4", 1 1/2, & 2" AGD2 40-200-X1 11 1/4 5 1/8 1" FNPT N/A 5 1/4 3.4 2 1/2" & 3" AGD3 40-200-X2 19 9 7/8 2" FNPT N/A 7 11.0 4" AGD3 40-200-X2 20 9 7/8 2" FNPT N/A 7 11.0 6" AGD3 40-200-X2 21 9 7/8 2" FNPT N/A 7 11.0 8" AGD4 40-200-X3 22 11/16 12 11/16 3" FNPT N/A 10 12.45 10" AGD4 40-200-X3 25 11/16 12 11/16 3" FNPT N/A 10 12.45 SS1107 05/12 Page 1 of 3

AGD AND AGD4A SERIES RELIEF VALVE DISCHARGE RATES MODEL RP40 SS1107 05/12 Page 2 of 3

AGD AND AGD4A SERIES 250 200 FLOW RATE (GPM) 150 100 2" 1-1/4" & 1-1/2" 50 1/2", 3/4" & 1" 0 0 20 40 60 80 100 120 140 160 180 ZONE PRESSURE (PSIG) RELIEF VALVE DISCHARGE RATES MODEL RP4A SS1107 05/12 Page 3 of 3

Job Name: Job Location: Engineer: Tag: AGD4A SERIES Contractor: P.O. Number: Representative: Wholesale Distributor: DESCRIPTION The Apollo Air Gap Drain (AGD4A6) is designed to funnel minor discharges from a Reduced Pressure Backflow Preventer s relief valve due to line pressure fluctuations and/or minor check valve fouling into the drainage system. Drain piping is easily attached to the AGD s threaded bottom outlet. The AGD4A6 fits Apollo s Model RP4A and RP4AN in sizes 2 ½, 3, 4, and 6. The AGD4A6 is ABS and PVC plastic with stainless steel screws and nuts. Note: The AGD4A6 is NOT designed to collect the full discharge capacity of the relief valve. Please refer to page 4 for RP Relief Valve full discharge rates. Shown without shut-off valves for clarity. RP4A Series AGD Model No. Order Code A B C D Outlet Connection Wt. Each RP4AN Series 2-1/2" AGD4A6 AGD4A6 11.28 10.87 2.63 3.13 2" FNPT 0.7 3" AGD4A6 AGD4A6 11.28 10.87 2.63 3.13 2" FNPT 0.7 4" AGD4A6 AGD4A6 12.02 10.51 2.63 3.13 2" FNPT 0.7 6" AGD4A6 AGD4A6 13.32 11.76 2.63 3.13 2" FNPT 0.7 SS1176 7/12 Page 1 of 4

DESCRIPTION The Apollo Air Gap Drain (AGD4A8) is designed to funnel minor relief valve (RV) discharges due to line pressure fluctuations and/or minor check valve fouling into the drainage system. The AGD4A8 fits Apollo s Model RP4A and RP4AN in size 8. Notes: Drainage piping is easily attached to the threaded portion of the AGD. The female NPT size is listed in the table under Outlet Connection. The AGD4A8 is ABS plastic with stainless steel screws and nuts. Drainage piping may be attached with a coupling and the appropriate cement or with a flexible pipe coupling. The OD is listed in the table under OD of C. The AGD4A8 is NOT designed to collect the full discharge capacity of the relief valve. Please refer to page 4 for RP Relief Valve full discharge rates. AGD4A SERIES Model AGD Model No. Order Code A B OD of C Outlet Connection Wt. Each RP4A AGD4A8 AGD4A8 21.3 9.1 3" Pipe 2-1/2" FNPT 1.5 RP4AN AGD4A8 AGD4A8 19.8 9.1 3" Pipe 2-1/2" FNPT 1.5 SS1176 7/12 Page 2 of 4

DESCRIPTION The Apollo Air Gap Drain (AGD4A12IN) is designed to funnel minor relief valve (RV) discharges due to line pressure fluctuations and/or minor check valve fouling into the drainage system. The AGD4A12IN fits Apollo s Model RP4A and RP4AN in sizes 10 and 12. Notes: Drainage piping is easily attached to the threaded portion of the AGD. The female NPT size is listed in the table under Outlet Connection. The AGD4A12IN is epoxy-coated steel with stainless steel screws. The AGD4A12IN is NOT designed to collect the full discharge capacity of the relief valve. Please refer to page 4 for RP Relief Valve full discharge rates. AGD4A SERIES Model AGD Model No. Order Code A B OD of C Outlet Connection Wt. Each RP4A AGD4A12 AGD4A12 26.3 7.7 4.00" 3" FNPT 4 RP4AN AGD4A12 AGD4A12 23.4 7.7 4.00" 3" FNPT 4 SS1176 7/12 Page 3 of 4

AGD4A SERIES 800 700 600 10" & 12" FLOW RATE (GPM) 500 400 300 8" 2-1/2", 3", 4" & 6" 200 100 0 0 20 40 60 80 100 120 140 160 180 ZONE PRESSURE (PSIG) Relief Valve Discharge Rates Model RP4A & RP4AN SS1176 7/12 Page 4 of 4