F64C, F64H - Olympian Plus Plug-In System Puraire high efficiency coalescing filter

Similar documents
P64F - Olympian Plus plug-in system Soft start/dump valves

BL68 - Olympian Plus plug-in system Filter/regulators and lubricators

F84C - Excelon Plus Modular System Oil removal filter

F84V - Excelon Plus Modular System Oil vapour removal filters

F84G - Excelon Plus Modular System General purpose filter

T84T - Excelon Plus Modular System 3/2 shut-off valve

BL84 - Excelon Plus Modular System Filter/regulator - Lubricator Combination Units

L84M, L84C - Excelon Plus Modular System Micro- and oilfog lubricator

F64G. Typical flow with 40 µm element at 90 psig (6.3 bar) inlet pressure and a 5 psig (0.35 bar) pressure drop. F64G- N - D 1/4 2 3/8 3 1/2 4 3/4 6

T84T - Excelon Plus Modular System 3/2 shut-off valve

BL84 - Excelon Plus Modular System Filter/regulator - Lubricator Combination Units

Weight (kg) Dimension No. G1/4 Exhausting None 0,2 1 T F2BG *1) Interface Exhausting None 0,4 3 T10-N10-D2BN

Drain. Element. Flow (dm 3 /s) * B92 - K- T1-RMG. N/en

Weight (kg) Model L92C- P-ETN. N/en

Drain. Technical data, standard model, shut off valve, filter/regulator with exhaust port and lubricator. Element

L84M, L84C - Excelon Plus Modular System Micro-Fog and Oil-Fog Lubricators

Super X Inline 3/2 and 5/2 Spool valves, solenoid and pilot actuated

V03, V04, V05 (EXCEL 32) 2/2 & 3/2 Direct solenoid actuated poppet valves

25000, 4/2 Direct solenoid actuated poppet valves

74 Series Combination Filter/Regulator and Lubricator Unit, featuring an in-line shut-off valve, and Quikclamp system.

, /2 Soft start ( soft clutch ) valve

V44/V45 series, 2 x 3/2, 5/2 & 5/3 Mini ISO Valves

2oo2 with bypass valve exhaust guards and indicators. 2oo2 I4. N/en

ICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves

98025 NAMUR/INLINE 3/2 way poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface

60 series, 2/2 or 3/2 Ball valve

N/** поставка оборудования для подготовки воздуха

with interchangeable cartridges: 1/8, 1/4 and 3/8 threaded or integrated with super-rapid fitting for tube with Ø 6, 8 and 10 mm

24010, 3/2 Direct solenoid actuated poppet valve

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO #1, #2, #3, #4 Steel reinforced main seals

PRA/842000/M, PRA/ Clean Line cylinder Magnetic or non-magnetic piston, double acting

Air Service Units Filter pressure regulator + Lubricator - Size 1. Series Technical characteristics. Construction and working characteristics

LPRA/182000/M, ISO cylinder Magnetic piston, double acting

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

Operating pressure (bar) kv factor (m 3 /h) *3)

Orders. Combination shut off valve, filter/regulator and lubricator. Models. BL92 ø 8 mm, G1/4. For further information

Material pressure (bar) (Cv (US) kv x 1,2 Seat

LRA/8000/M/EX, LRA/8000/EX, ISO cylinder Magnetic & Non-magnetic piston, double acting

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. Semi-standard

M/146000/EX, M/146100/EX, M/146200/EX, LINTRA PLUS cylinder Magnetic & Non-magnetic piston, double acting

P72F P74F P74F-AD P7 F- - 1/4" (72) 2 3/8" 3 1/2" (74) 4 3/4" (74) 6. ISO G parallel

AUTO STAR with central connector M12x1

Parker Global Air Preparation System

Flow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en

IC3A, IC3D, IC4A and IC4D ISO Spirax-Monnier International Ultraclean Compressed Air Filters

Nugget 40, V08 series

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

A44000, LINTRA-LITE Rodless Cylinders Non-magnetic and Magnetic Piston, double acting

83 series Brass compression fittings

82 series Brass compression fittings

FLEXIBILITY, VALUE AND EASE OF USE NO TOOLS REQUIRED

M/48, M/148. 3/2 Poppet Valves Electrically Actuated. Miniature, 22 mm normally closed and normally open models. Sub-base mounted and manifold mounted

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

VR61, 3/2, 2 x 3/2, 5/2 or 5/3 Solenoid and pilot actuated spool valves

LRM/55401/M, Roundline cylinder Magnetic piston, double acting

NFPA Double acting imperial cylinders

Air Preparation Products

VM15 series, 2 x 3/2, 5/2 or 5/3 Valve islands

02/97 N/** Our policy is one of continued research and development. We therefore reserve the right to amend,

VAL /4" to 2" Solenoid Pilot Actuated 2/2, 3/2, & 4/2 Inline Valves. Solenoid pilot operated spring return inline valves with nonlocking

Compressed Air Filters

ARO-FLO SERIES FILTERS, REGULATORS AND LUBRICATORS

VR61 and VR62 3/2, 2 x 3/2, 5/2 and 5/3 directional control solenoid and pilot valves 1/4 or 3/8

V50... V53 Series 3/2, 5/2 and 5/3 way valves Solenoid actuated and pilot operated 1/8... 1/2

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information

High pressure valves. 80 to 350 bar

AIR PREPARATION PRODUCTS. Table of Contents

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

FRL/AirCare Air Controls & Accessories

P3Y Series Air preparation system. 3/4 & 1 Body ported

Stainless Steel FRLs

Parker Global Air Preparation System. A complete air preparation system

Model Model 815

AIR PREPARATION PRODUCTS

Filters, regulators, and lubricators

3000 Series filters 3/4" and 1" Ports

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. 3 (Closed center) 3/4, 1 3 (Exhaust center)

PRA/882000/M/EX, IVAC Clean Line cylinder Magnetic piston, double acting

Excel V03, V04 and V05 Series

3 (R) 1 (P) 5 (S) Port size 1 (P) 2 (A) 3 (R) 4 (B) 5 (S)

Installation Components AirCare Air Preparation Systems

M/146000, M/146100, M/146200

Compressed Air Cleaning Filter Series

Accessories for Filters, Regulators, and Lubricators

Solenoid pilot operated spring return inline valves with nonlocking overrides, 120V, 60 Hz, and cablegrip connector

Modular line 042 1/4. Regulator. Regulator

Installation Components AirCare Air Preparation Systems

5.22 A IR PREPARATION FILTERS: HIGH EFFICIENCY H IGH FLOW AIR FILTER SERIES AF AF (1 1 2) AF (2) AF (1 1 2) AF (2) S TOCKED

M/1000, Heavy Duty Cylinders Double Acting

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. Semi-standard

26220, 26230, For single- and double-acting drives. Standard manual override with detent. Compact design. Exhaust air silencers.

solenoid/air operated

Strokes (mm) N/en

RM/900/M Heavy duty cylinders Ø 1 1/4... 4

50 SERIES FILTER F50B Series F50B-04 pictured Application ANSI SYMBOL Primary air filters are designed to separate liquid, water, rust, pipe scale, an

COMPRESSED AIR FILTERS AF SERIES Product overview

1 6 / 2 6 S E R I E S C O M P A C T & S T A N D A R D M O D U L A R A I R P R E P A R A T I O N S Y S T E M S

SentronicPLUS IO-Link CLASS A Electronic Pressure Regulator. Installation Manual

Transcription:

> > Port size: /... 3/ (ISO G/PTF) > > Service indicator standard > > High efficiency coalescing filters > > Quick release bayonet bowl > > Coalescing element removes sub-micron particles and converts oil and water mist to liquid form to drain away Technical features Medium: Compressed air only Maximum operating pressure: bar (6 psi) Flow: See diagrams on page Remaining oil content:, mg/m 3 max at +ºC (+ F) Particle removal: To, μm Port sizes: /, 3/, / or 3/ Drain: Manual or automatic utomatic drain conditions: Pressure to close drain: >,3 bar (.3 psi) Pressure to open drain: <, bar (.9 psi) Minimum air flow to close drain:,6 dm 3 /s (.3 scfm) Service life indicator: Mechanical standard Bowl size:, litre ( fluid oz) mbient/media temperature: -... +65 C (-... +9 F) ir supply must be dry enough to avoid ice formation at temperatures below + C (+35 F). ote: Install an F6G filter with a 5 µm filter element upstream of the F6C/H filter for maximum service life. Materials: Body and yoke: Zinc alloy Connection piece: luminium Metal bowl: luminium Element: Composite Prismatic liquid level indicator: Grilamid Elastomers: BR Technical data, standard models Symbol Port size Size Filter element (µm) Flow * (dm 3 /s) Bowl Drain Weight (kg) Model G/, 6 Metal Manual, F6C-GD-MD G3/, Metal Manual, F6H-3GD-MD G/ Basic, Metal Manual,6 F6H-GD-MD G3/, Metal Manual, F6H-6GD-MD Without yoke, Metal Manual, F6C-D-MD Without yoke, Metal Manual, F6H-D-MD G/, 6 Metal utomatic, F6C-GD-D G3/, Metal utomatic, F6H-3GD-D G/ Basic, Metal utomatic,6 F6H-GD-D G3/, Metal utomatic, F6H-6GD-D Without yoke, Metal utomatic, F6C-D-D Without yoke, Metal utomatic, F6H-D-D * Maximum flow at 6,3 bar (9 psi) - guaranty optimum oil removal performace. Option selector Bowl/Element Standard flow C High flow H Port size / 3/ 3 / 3/ 6 Without yoke Threads form PTF ISO G (standard) G Without yoke (standard) F6 - - D Drain utomatic Manual Service life indicator Mechanical (standard) Without M D without notice, the specifications given in this document. (99-5c) 5 IMI International s.r.o. /6 en..5.

Flow characteristics F6C Port size: / F6H Port size: / bar bar,5,6,5 6,3,5,6,5 6,3 Pressure drop p,,3, Pressure drop p,,3,,, 6 dm 3/s 3 5 6 dm 3/s ir flow ir flow Typical performance characteristics (bar) Maximum flow (dm 3 /s)* F6C F6H 6,, 3, 9,3 5,3,9 6,3 6,, 6,9 9,5 9 9, 33,5 * Maximum flow to maintain stated oil removal performance. en..5. without notice, the specifications given in this document. (99-5c) 5 IMI International s.r.o. /6

ccessories and service kit 5 ccessories Models with G-thread Single yoke Double yoke 3/ Shut-off valve Threaded inlet only Threaded outlet only End connector kit Rear entry bracket kit Thread 5 G/ Y6-G- Y6-G- T6T-GB-P T6T-GC-P G3/ Y6-3G- Y6-3G- T6T-3GB-P T6T-3GC-P G/ Y6-G- Y6-G- T6T-GB-P T6T-GC-P 55-5 G3/ Y6-6G-* Y6-6G-* T6T-6GB-P T6T-6GC-P 55-53 -6-9 / PTF Y6-- Y6-- T6T-B-P T6T-C-P 3/ PTF Y6-3- Y6-3- T6T-3B-P T6T-3C-P / PTF Y6-- Y6-- T6T-B-P T6T-C-P 55-5 3/ PTF Y6-6-* Y6-6-* T6T-6B-P T6T-6C-P 55-55 *These yokes are supplied with two end connenctor kits as standard. Bracket mounting ut Yoke connector kit Porting block djustable pressure switch Padlock with two keys 9 5-5 5-9 53-5 5-5 36-99 63633 (brass) Service kit Service kit F6C Service kit F6H F6C-KITC F6H-KITC /6 without notice, the specifications given in this document. (99-5c) 5 IMI International s.r.o. en..5.3

Basic dimensions F6C F6H Dimensions in mm Projection/First angle #,5 39 # 6 3 3 5 or 3/6 # 5 56 # 3 3 5 or 3/6 Manual drain 33,5 ø 6,5 utomatic drain 5 Manual drain 33,5 ø 6 utomatic drain 3 5 5 5 5 ø33 3 # Minimum clearance required to remove bowl Main ports /, 3/, / or 3/ 3 For main ports 3/ only 5 Sight glass Gauge port / Single yoke with bracket mounting Double yoke with bracket mounting 3 3 9 5 93, 3,5,,5,,5 5 5 93, 3,5 en..5. without notice, the specifications given in this document. (99-5c) 5 IMI International s.r.o. /6

Rear entry bracket -6-9 Porting block 5-5 Dimensions in mm Projection/First angle 35, 9,5 G 3/ 5 6,5 ø G3/ +,,5,5 5,5 35,5,5 3,5 - G/ O -ring (included in scope of supply of bracket) djustable pressure switch 36-99 Pg Voltage V d.c./ V a.c. Current,5 (d.c.); 5 (a.c.) Pressure range... bar Repeatabillity % of full set point range at C 6 6 6 verage deadband Electrical connection (corresponding to choosen coil),..., bar E 53-3 - Form C, 5 mm 5 Degee of protection: djustable Material IP65 Standard Body: luminium, Elastomers: BR ø 6 djusting screw 3/ Shut-off valve Symbol B ø C Model 3 B G/ T6T-G*-P G3/ T6T-3G*-P OPE 3 G/ T6T-G*-P G3/ 5 33 T6T-6G*-P 6 ø C * B = Threaded inlet only, C = Threaded outlet only Rc / 3,5,5 Padlock hole ø,5 mm Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features/data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI Precision Engineering, IMI International s.r.o. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. /6 without notice, the specifications given in this document. (99-5c) 5 IMI International s.r.o. en..5.5