Deep UV Deuterium Light Source. Operation Manual

Similar documents
Deuterium and Tungsten-Halogen Hybrid Light Source. Operation Manual

30W High Stability Tungsten- Halogen Light Source - ASB-W Operation Manual

AvaLight-DHS Deuterium Halogen Light Source Operating manual

DH-2000 Deuterium-Halogen Light Source Installation and Operation Manual

Microscope light manual

D2H and D2H-2. Deuterium-Halogen Light Sources. INSTRUCTION MANUAL. Serial No. World Precision Instruments

Thermaltake Warranty / Support Information

This document describes:

TECHNICAL INFORMATION

Lambda HPX-L5. High-Power LED Light Source System (Air-Cooled with Liquid Light Guide) Operation Manual. Rev (( )

Installation Instructions. Fog Lights. The lamps get very hot when they have been in use. Do not touch them as they may cause burns.

Panel Mount Digital Tachometer Model

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

Installation & Operation Manual Chef Base

MODEL 5120 Tire Repair Station

LBT-3 WITH 300 CFM RECLAIM MANUAL NUMBER: 506 TABLE OF CONTENTS

Further information: Berriman Associates Model 850P.2 Owners Manual

This document describes:

USER S MANUAL & WARRANTY INFORMATION

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Installation Instructions

LIONEL No Gabe the Lamplighter Owner s Manual 6/01

DH-2000 Deuterium-Halogen Light Source Installation and Operation Manual

MODEL 950C-NP-UV Installation and Owners Manual

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Introduction

MANUAL Model: PT 12/24-60 Solar Converters Inc. - Rev. F

Wiring Installation Instructions for : Pressure. Wiring Installation Instructions for : Temperature. 2 1/16 Spek Pro Professional Racing Gauge

ABRASIVE BLAST CABINET

AQUA2000 ADVANCED WATER TREATMENT SYSTEMS OWNER S MANUAL INCLUDES: Restrictions. Installation. Operation. Maintenance. Changing the Filter

Spotlight 1,000,000 Power Series Cordless Rechargeable

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

Owner s Guide APS596Z

Installation Instructions for AEM Serial Gauge

FUSE PANEL Technical Practice FDP /10 GMT NEBS Level 3 Certified

Cabling for power, control, and video must be run to the installation site before the mount is installed.

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

Installation and Operation Manual

Installation Instructions

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

SPC Series. Digital Scale. Operation Manual

Active Controlled Cooling System

Broadband PowerShield. CP27U Models. User Manual

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

WARNINGS, CAUTIONS AND NOTES

INSTALLATION AND INSTRUCTIONAL MANUAL ELECTRIC V-BOX MATERIAL SPREADERS

FUSE PANEL Technical Practice FDP /20 GMT NEBS Level 3 Certified

Model Combustible Gas Sample Draw Detector Head Operator s Manual

Propane/CNG Solenoid Valve Controller

& r"1aintef~ance. Your KENBAK-l computer is a quality instrument which is. should expect months or years of operation without significant

AQUA2000 From O3PURE

Owner s Guide CA 4555

Integrated Heating System

Parts Manual Vermeer/ McLaughlin Mud System 230P

Operating Instructions August 2013

OWNER'S MANUAL POWER BOOSTER. Rechargeable 12 Volt DC power supply. Item # Enclose copy of original sales receipt

Data Sheet. TitanTurbo TM Lamina Lighting Incorporated

INSTRUCTION MANUAL. TEC Controller/Thermocouple Thermometer

Owner s Guide. ca5154

Model:M5B/M5W/M5N. Installation Guide. Specifications Desktop Weight Capacity Keyboard Tray Weight Capacity Height Adjustable Range

Model Combustible Gas Sample Draw Detector Head Operator s Manual

Infinitybox Express Road Race Car Kit Installation Guide

LS-1 Series Tungsten Halogen Light Sources

Toll Free DX100. Owner's Guide. Printed in China

10 Year Limited Warranty

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

2. Description of Standard NUV Lightsource (350nm-450nm) 3 3. Description of Deep UV (220nm-280nm) and Mid UV (280nm-310nm) Lightsource Systems 3

Tachometer. English. Users Manual

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount

ATD Amp Carbon Pile Battery Tester User s Manual WARNING

Page 1 of 5 FL-4020 FLUORESCENT BALLAST CONTROLLER

/99 LIONEL. Lionel Route 66 Cafe Owner s Manual

CEAT SPECIALTY TIRES INC. LIMITED WARRANTY POLICY For AGRICULTURE BIAS TIRES

Image Pro. Create eye-catching holiday displays or project personalized images. Image projection system

Long-Range Barrier Sensors

Parts Manual Vermeer/ McLaughlin Mud System 230P

Model 617 Benelli Tactical Light. Users Manual. Benelli Shotgun M1 Super Gauge Serial No. M and later Protected by US.

INSTALLATION AND OPERATIONS MANUAL POWER OPERATED TUBING STORAGE REEL MODEL TSR-P PRODUCTS, INC.

Pure Sine Wave Inverter 600W-24V User Manual

MODEL TC400 TIRE CART. Installation, Operation & Repair Parts Information REV P/N:

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

Fiber Optic Illuminator. Model 21AC Model 21DC

Instruction Manual. Backup Sensor Reversing System RVS-RS103

Model FM2642 Wall Mount. Full Motion Television Wall Mount

Thank you for purchasing a 911EP GALAXY Light Bar! Every light bar is carefully inspected for defects prior to shipment.

Owner s Guide PR1BZ PR1BZLR

Operation Manual REFLEX SIGHT NC 6X Sparks Ave., Toronto, ON, M2H 2S5, Canada

INSTRUCTION MANUAL. Rotary Unidirectional Piezoelectric Motor Evaluation Kit. (Model: UPM-28) Made in USA

Model GD-K77D4X-XX Supplement to the GD-K77D Operator s Manual

shadow focus floodlight SFS-300 INSTRUCTIONS

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Power. On Your Terms.

Owner s Guide CARS & CA4B5

Active Evacuation System (AES)

Noran Tel. FUSE PANEL Technical Practice N21C110-NCY 5/5 GMT (20Amp GMT) NEBS Level 3 Certified

CA 5054 Owner s Guide

"SPOAU" DEDICATED 100% OUTSIDE AIR UNITS Self Contained Single Package or Split System Units

Noran Tel. a subsidiary of Westell Inc. Fuse Panel Technical Practice NPGMT /10 GMT NEBS Level 3 Verified

Operator s Manual. Light & Laser Sight. GripSense

Installation / Operation Instructions Sunnex ORION Series Exam Lights

Transcription:

Deep UV Deuterium Light Source - ASBN-D130 / ASBN-D230 - Operation Manual

Important Safety Notices 1. Never look directly into the UV light, as this can cause eye damage. 2. Do not remove or modify any installed safety device on this equipment. Doing so will void your warranty and create an unsafe operating environment. 3. Do not use the unit if it is damaged in any way. Contact your dealer for repair or replacement information. Warranty and Liability This SP s product is warranted against defects in material and workmanship for a period of one year from the date of shipment. During the warranty period, Spectral Products will, without charge, repair or replace, at its discretion, the defective product or component parts. For warranty service or repair, this product must be returned to a service facility designated by Spectral Products (SP). For products returned under warranty, the Buyer shall prepay shipping charges (including shipping charges, duties, and taxes for products returned to SP from another country), and SP will pay for shipping charges to return the product to the Buyer. This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations, modifications or repairs, if the serial number is altered, defaced or removed, the improper or inadequate maintenance by the Buyer, Buyersupplied software or interfacing, or improper site preparation or maintenance. No other warranty is expressed or implied. SP shall not be liable for any consequential damages, including without limitation, damages resulting from loss of use, as permitted by law.

Specification The following tables provide information on our high power Deuterium light sources. Overview Mount Housing Output type Tapered flange, adjustable, Post mounting for standalone operation Air cooled w/ two focusable fused silica doublet collection lens sets, 1 size Dimension: 11.0 X 11.5 X 5. Monochromator Matching (M) : CM110, DK240, or DK480 Fiber coupling (F) : SMA905 or FC Electric Deuterium Electric Input Electric Output Input Voltage: 24 Vdc regulated (<45W), 5Vdc (TTL) disable input Input Current: 2A Anode: 60-100Vdc / 30 W max Trigger pulse: 600±50 Vpk continuous (Anode Vdc included) Heater Warm up: ~20-30 seconds Regulation: +/-0.5% typically Others Temperature: 0-40 ºC Humidity: 95% Cooling: 20 CFM of forced air across the component side

Spectrum The deuterium (D2) lamp is designed for use in spectroscopic applications where high intensity and stability in the 190 to 400nm band is needed. Above 400nm, some spiky spectra will be detected also. The envelope of D2 lamp is made of fused silica. Its transmittance is as follows.

Operation Front Back Switch for the 2 nd D2 lamp. Only available for ASBN- D230 Switch Fiber coupling Cooling Fan terminal Input & Fuse Component terminal input switch Fuse Cooling fan switch for the 2 nd D2 lamp Description Connect power cable to provide voltage to our high power Deuterium light source. Turn on to supply power to the D2n lamp. The RED light illuminates when this switch is in the On position. Contains the fuse to protect the unit against overload: Fuse type: 5A/250V Cools the interior of the light source housing. Note: Although block with heat shield system, do not look into the light beam through this fan. For ASBN-D230 only: Turn on/off switch for the 2 nd lamp.

Bulb Replacement 1. Turn off all power. 2. Wait until the lamp cools down. 3. Remove housing. 4. Remove heat shield. 5. Take off the three deuterium lamp leads on the bottom. 6. Unscrew the set-screw for the deuterium bulb. 7. Take out the old bulb and replace the new one. 8. Adjust the bulb to be centered properly looking through the focusing lens set. If there is a fiber coupling plug attached, please take it off first.

NOTE: When adjusting the new deuterium lamp, please be careful not to touch it with a bare hand. Technical Support Toll Free: (877) 928-5834, ext 15 Tel: (860) 928-5834, ext 15 Fax: (860) 928-2676 Website: http:// Email: support@spectralproducts.com / mdrugan@spectralproducts.com