DH-2000 Deuterium-Halogen Light Source Installation and Operation Manual

Similar documents
DH-2000 Deuterium-Halogen Light Source Installation and Operation Manual

AvaLight-DHS Deuterium Halogen Light Source Operating manual

D2H and D2H-2. Deuterium-Halogen Light Sources. INSTRUCTION MANUAL. Serial No. World Precision Instruments

Deep UV Deuterium Light Source. Operation Manual

BroadBand PowerShield. 20 AHr Battery. User Manual

Deuterium and Tungsten-Halogen Hybrid Light Source. Operation Manual

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

LS-1 Series Tungsten Halogen Light Sources

4 - SETTING UP THE MACROMAN CHARGING POSITION 4 Wall mounted 4 Workbench set-up 4

FieldView External Charger. User Guide

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

The Efficient Solution for Pipetting up to 100 ml at once! USER'S GUIDE

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Verti Blast. User Manual. Order code: EQLED355

Xenon Fiberoptic Lightsource

LDLS Laser-Driven Light Source. EQ-1000 High Brightness DUV Light Source. Operation Manual

Lamp kit. Installation manual SIM 7 series R

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

Fiber Optic Illuminator. Model 21AC Model 21DC

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

HARDWARE KIT INSTALLATION GLOVES

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

30W High Stability Tungsten- Halogen Light Source - ASB-W Operation Manual

User Manual Industrial Power Storage System (ips) ips-m Series Battery System

Welcome to PTI--Photon Technology International--Optical Building Blocks!

Operating Instructions

Safety, Installation and Service Manual Models 1952, 1953 & 1972

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

c-go 24V/6A 24V/8A 24V/12A

Video & Power Over Coax Kit

Owner's Manual. For latest instructions please go to

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX 512. Master/Slave. 115/230V Power Switch. Replaceable Fuse.

Compact Scales. Software Revision V1.25 & above

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

1. Before You Begin What Is Included... 3 Unpacking Instructions Claims Product at a Glance... 3 Safety Instructions...

Operating Manual. Follow all safety precautions!

B-RAD Select USER MANUAL TABLE OF CONTENTS

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

300 Volt Electrophoresis Power Supply

User Guide. Digital Shipping Scale S150

EASY CHARGE Waterproof portable Battery Charger

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

Operating instructions Bedienungsanleitung Mode d emploi

PANcharge1k Battery Charger User's Manual

FiberSource Q150. user manual P/N

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

Owner's Manual. For latest instructions please go to

P/N Wheeler. user manual

TABLE OF CONTENTS 1. BEFORE YOU BEGIN...

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

OCTA FLUORESCENT 7 SOCKET FIXTURE

UView Mini Transilluminator

USER MANUAL GEBRUIKSAANWIJZING. Phoenix 12/150 Phoenix 24/150 Phoenix 48/150

WF-5110R True Sine Wave Inverter

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Operating Manual. Follow all safety precautions!

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

User s Manual TX MHz Powercaster TM Transmitter

LIGHT & SOUND BATH VANITY LIGHT

Powerware Vdc Extended Battery Cabinet User s Guide.

i3000s/i2000 Flex AC Current Probe

Operator Manual For use with WFCO ULTRA III Deckmount Converter WF-9800 Series (model number located on the cover of the unit)

Measurements are expressed in millimeters.

Sylvania 9 Color Changing One Plug Tree Tree ID # T5, Item # V

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Owner's Manual. For latest instructions please go to

FOR INDOOR/SEASONAL USE ONLY

Uninterruptible Power Supply

Event Spot WW Triac. User Manual. Order codes: LEDJ237 - Black Housing LEDJ237A - White Housing

NCSA 20plus Service Manual

TABLE OF CONTENTS. Page 2 of 12 DataStream 4 User Manual Rev. 2

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

Instruction Manual. Blink HQ Charger. Charge on. a CarCharging Company

Snapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Stereo Power Amplifier

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

7.5 FT PRE-LIT ENGLEWOOD PINE TREE

Mania EF1 user manual

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

1200W INVERTER GENERATOR

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

WF-5100 Series True Sine Wave Inverters

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

System 3 ZB1PS Device Chassis. Operator s Manual

User manual Temperature Calibrator JOFRA CTC-140/320/650 A/B JOFRA CTC-1200 A Copyright 2005 AMETEK DENMARK A/S ( UK)

UV Transilluminator Dual Wavelength (Large)

Installation and Operations Manual

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

Digital/Analog Amplifiers Installation Instructions

CYCLONE PocketMax PP-1000 Compact Battery Pack for Portable Flashes. User Manual

GSL Electronics Modified Sine Wave Power Inverters

Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide

900 PEAK AMP PORTABLE JUMP STARTER

Go to to register your product and find more information.

Transcription:

DH-2000 Deuterium-Halogen Light Source Installation and Operation Manual For Products: DH-2000-BAL, DH-2000-BAL-TTL-24V, DH-2000-FHS-DUV-TTL, DH-2000-S-DUV-TTL Document: 355-00000-000-01 Version 1.0 WARNING Protective Eye Wear Must Be Worn When Using This Instrument - Intense Ultraviolet Radiation Present See Important Safety Notices inside. 000-10000-080-02-2

AMERICAS & WORLD HEADQUARTERS Phone: +1 727-733-2447 Fax: +1 727-733-3962 Sales: Orders: Support: info@oceanoptics.com orders@oceanoptics.com techsupport@oceanoptics.com EUROPE, MIDDLE EAST & AFRICA Phone: +31 26-319-0500 Fax: +31 26-319-0505 Email: info@oceanoptics.eu Germany : +49 711-341696-0 UK : +44 1865-811118 France : +33 442-386-588 ASIA Phone: +86 21-6295-6600 Fax: +86 21-6295-6708 Email: asiasales@oceanoptics.com Japan & Korea: +82 10-8514-3797 www.oceanoptics.com Ocean Optics, Inc. 830 Douglas Ave. Dunedin, FL 34698 USA Manufacturing & Logistics 4301 Metric Dr. Winter Park, FL 32792 USA Sales & Support Geograaf 24 6921 EW Duiven The Netherlands Manufacturing & Logistics Maybachstrasse 11 73760 Ostfildern Germany Ocean Optics Asia 666 Gubei Road Kirin Tower Suite 601B Changning District Shanghai PRC, 200336 Copyright 2017 Ocean Optics, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, by any means, electronic, mechanical, photocopying, recording, or otherwise, without written permission from Ocean Optics, Inc. Trademarks All products and services herein are the trademarks, service marks, registered trademarks or registered service marks of their respective owners Limit of Liability Every effort has been made to make this manual as complete and as accurate as possible, but no warranty or fitness is implied. The information provided is on an as is basis. Ocean Optics, Inc. shall have neither liability nor responsibility to any person or entity with respect to any loss or damages arising from the information contained in this manual 355-00000-000-01

Table of Contents Table of Contents... i About This Manual... iii Document Purpose and Intended Audience... iii What s New in this Document... iii Document Summary... iii Product-Related Documentation... iii Upgrades...iv Important Safety Notices... v Warranty... v Certifications and Compliance...vi Chapter 1... 1 Setup... 1 Overview... 1 Unpacking the DH-2000... 1 Contents... 2 Connecting the Fiber Optic Cable... 2 Chapter 2... 4 DH-2000 Specifications... 4 Operating Environment... 4 DH-2000 Components... 4 Front Panel... 5 Rear Panel... 6 Specifications... 8 Parts List... 10 Pinout Information... 11 Pinout Diagram... 12 Chapter 3... 13 Operating Instructions... 13 355-00000-000-01 i

Table of Contents Operating the Lamp... 13 Starting Main Power... 13 Manual Operation of Lamp... 13 Starting the Lamp... 13 Turning the Lamp Off... 14 Warming Up the Lamp... 14 Manual Operation of the Shutter... 14 Remote Operation of the LAMP and Shutter... 15 Operating the Filter Slit (DH-2000-FHS-DUV-TTL only)... 16 Adjusting Halogen Lamp Output... 17 Chapter 4... 18 Troubleshooting... 18 Appendix A... 20 Maintenance... 20 Overview... 20 Bulb Replacement... 20 Replacing the Deuterium Bulb for All Models Except DH-2000-BAL... 21 Replacing the Deuterium Bulb for DH-2000-BAL Model... 21 Replacing the Halogen Bulb for All Models Except DH-2000-BAL... 22 Replacing the Halogen Bulb for DH-2000-BAL Model... 24 Warranty Service... 26 Index... 27 ii 355-00000-000-01

About This Manual Document Purpose and Intended Audience This document provides you with installation information to get your DH-2000 light source up and running. What s New in this Document This version of the Deuterium-Halogen Light Source Installation and Operation Manual describes the re-engineered DH-2000 family of light sources. To verify that you have a reengineered unit, look for the phrase Assembled in USA on the product label. Document Summary Chapter Chapter 1: Setup Chapter 2: DH-2000 Specifications Chapter 3: Operating Instructions Chapter 4: Troubleshooting Appendix A: Maintenance Description Contains a list of package contents and unpacking instructions. Also contains instructions for connecting the fiber optic cable. Contains operating environment specifications, as well as other physical details of the product, a parts list, and pinout information for the D-SUB-15 connector. Provides instructions for operating the DH-2000 lamp and the TTL shutter. Contains a table of troubleshooting information. Provides instructions for returning the unit to Ocean Optics for bulb replacement. Product-Related Documentation You can access documentation for Ocean Optics products by visiting our website at http://www.oceanoptics.com. Select Technical Operating Instructions, and then choose the appropriate document from the available drop-down lists. 355-00000-000-01 iii

About This Manual Ocean Optics offers a Glossary of spectroscopy terms to help you further understand your state-of-the-art products and how they function, located at: http://oceanoptics.com/glossary/. Detailed instructions for OceanView Spectrometer Operating Software are located at: http://oceanoptics.com/wp-content/uploads/oceanviewio.pdf. Upgrades Occasionally, you may find that you need Ocean Optics to make a change or an upgrade to your system. To facilitate these changes, you must first contact Customer Support and obtain a Return Merchandise Authorization (RMA) number. Please contact Ocean Optics for specific instructions when returning a product. iv 355-00000-000-01503

About This Manual Important Safety Notices 1. Do not remove or modify any installed safety device on this equipment. Doing so will void your warranty and create an unsafe operating environment. 2. Dangerous voltages are present in this device. 3. Only allow qualified personnel to operate this unit. 4. Do not use the unit if it is damaged in any way. Contact your dealer for repair or replacement information. 5. Always screw in the fiber optic cables before starting the instrument. WARNING Protective eyewear must be worn when using this equipment. Intense ultraviolet radiation is present. Never look directly into the light beam, as this can cause eye damage. Warranty Light Source products are covered by Ocean Optics Exclusive Three Year Warranty. For details, please visit the following webpage: https://oceanoptics.com/wp-content/uploads/warranty-sheet.pdf There are no warranties for the bulbs/modules. This instrument should not be used for any Clinical or Diagnostic purposes. Data generated in these areas is not warranted in any way by Ocean Optics, Inc. 355-00000-000-01 v

About This Manual Certifications and Compliance ISO CERTIFICATION Ocean Optics, the industry leader in miniature photonics, has been certified for ISO 9001:2008 applicable to the design and manufacture of electro-optical equipment since 2009. WEEE COMPLIANCE The WEEE symbol on the product indicates that the product must not be disposed of with normal household waste. Instead, such marked waste equipment must be disposed of by arranging to return to a designated collection point for the recycling of waste electrical and electronic equipment. Separating and recycling this waste equipment at the time of disposal will help to conserve natural resources and ensure that the equipment is recycled in a manner that protects human health and the environment. This device has been tested and complies with the following standards: EN 61326-1:2013 EN 61000-4-2:2009 / IEC 61000-4-2:2008 EN 61000-4-3:2006 / IEC 61000-4-3:2006 EN 61000-4-5:2006 / IEC 61000-4-5:2005 EN 61000-4-11:2004 / IEC 61000-4-11:2004 EN 55011: 2009/A1:2010 Group 1 Class A ANSI C63.4:2003 vi 355-00000-000-01503

About This Manual FCC COMPLIANCE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which the user will be required to correct the interference at his own expense. 355-00000-000-01 vii

Chapter 1 Setup Overview The following sections provide instructions on unpacking and setting up your DH-2000 Light Source. Before using the DH-2000 for the first time, check for transport damage. Be sure to adhere to all warnings on the unit and in this manual. Unpacking the DH-2000 Procedure DH-2000 Deuterium-Halogen Light Source 1. Unpack your lamp assembly carefully. Although the lamp is rigidly mounted, dropping this instrument can cause permanent damage. 2. Inspect the outside of the instrument and make sure that there is no damage. Do not use the instrument if damage is present. Contact your dealer for repair or replacement information, if necessary. 355-00000-000-01 1

1: Setup 3. Use this instrument in a clean laboratory environment (see Operating Environment). Contents Your DH-2000 package should contain the following: DH-2000 High-Power Light Source Power cord UV safety goggles One IC-DB15-2 interface cable for shutter operation Quick Start Document Connecting the Fiber Optic Cable Connect the fiber optic cable to the unit prior to turning on the deuterium or halogen lamps. Procedure To connect the fiber optic cable to the DH-2000: 1. Locate the cap on the front of the DH-2000. Cap covering SMA connector 2 355-00000-000-01503

1: Setup 2. Lift the cap on the front of the DH-2000 to expose the SMA connector. SMA connector is exposed 3. Connect the fiber optic cable to the SMA connector. 355-00000-000-01 3

Chapter 2 DH-2000 Specifications This section provides information on the operating environment, physical controls, and dimensions of the DH-2000. It also provides pinout information for the connector. Operating Environment The following table provides information on optimizing the operating environment of your DH- 2000. Moisture 5-95% without condensation at 40 C Ventilation Temperature Object and Liquid Entry DH-2000 Components Unit should be situated so that its location or position does not interfere with proper ventilation. 5 C 35 C. Unit should be situated away from any device that emits excessive heat. Unit should be positioned so that objects do not fall on top of the unit. Additionally, ensure that no liquids are spilled into the enclosure through openings. The following sections describe the components located on the front and rear of the DH-2000 unit. 355-00000-000-01 4

2: DH-2000 Specifications Front Panel Deuterium On/Off Switch Halogen On/Off Switch Halogen Status LED Deuterium Status LED Power LED Mechanical Protection SMA Connector Shutter Switch Component Deuterium On/Off Power LED Mechanical Protection SMA Connector Halogen On/Off Description Press the blue DEUTERIUM button to turn the Deuterium lamp on or off. The bulb requires a warm-up time of 20 seconds before the Deuterium lamp is illuminated. You must allow the bulb to warm up to receive accurate data from the lamp. LED located under button lights green upon successful illumination or red to indicate lamp malfunction. Indicates the power state of the DH-2000. Covered to protect users from unintentionally looking directly at the beam of light. Connect the fiber cable to the DH-2000 BEFORE turning the lamp on to avoid unnecessary exposure to UV radiation. Always wear proper eye protection when using the DH-2000 lamp. Press the red HALOGEN button to turn the Halogen lamp on or off. LED located under button lights green upon successful illumination or red to indicate lamp malfunction. Shutter Mode Switch Sets the operational mode of the shutter. Open indicates that the shutter is constantly open; Closed indicates that the shutter is constantly closed; TTL indicates the shutter is operated via the rear panel connector (see Rear Panel). 355-00000-000-01 5

2: DH-2000 Specifications Rear Panel Cooling Fan Unit Label Input Terminal for Power Cord Main Power Switch TTL Input Variable Resistor Fuse Compartment DH-2000-FHS-DUV, DH-2000-S-DUV-TTL, DH-2000-BAL Cooling Fan Unit Label Main Power Switch Input Terminal for Power Cord TTL Input Variable Resistor Fuse Compartment DH-2000-BAL-TTL-24V 6 355-00000-000-01503

2: DH-2000 Specifications Component Main Power Switch Fuse Compartment Input Terminal for Power Cord TTL Input Variable Resistor Description Turn on to supply power to the unit. The Power LED lights when this switch is in the ON position. Contains the fuse to protect the unit against overload: 2.0 Amp, 250 V slow blow. Littlefuse part # 0218002 Plug power cord into this terminal. Note: Only connect the power cable to the lamp when the Main Power Switch is in the OFF position. THE INSTRUMENT MUST BE CONNECTED TO A GROUNDED (EARTHED) OUTLET D-SUB 15-pin connector for automatic shutter control and remote lamp enable Use a screwdriver to adjust the intensity of the halogen lamp to optimize the intensity between deuterium and halogen light in UV-VIS applications. Unit Label - Model DH-2000-xxxxx Deuterium-Halogen Lightsource - Version Europe / USA - Main connection 115 / 240V 47-63Hz - Power consumption 50 Watt - Max. Ambient Temperature 35 C - Serial-No. xxxxxx Cooling Fan Cools the interior of the DH-2000. Do not obstruct. 355-00000-000-01 7

2: DH-2000 Specifications Unit Specifications Specifications Deuterium Lamp Criteria Tungsten-Halogen Lamp Criteria Wavelength Range 210 2500 nm 190 2500 nm (DUV models) Stability 0.01 % / h@ 254 nm 0.01 % / h@ 700 nm Drift 0.01 % / h@ 254 nm 0.01 % / h@ 700 nm Warm-Up Time 20 minutes* 25 minutes* Lamp Lifetime (typical) Radiation Characteristics Possible Filter Dimensions (FHS model only) 2000 hours (13 ) Focused Diameter or square 20-25mm Thickness 4-6mm Performance Guaranteed Temperature 5 C 35 C Humidity 5-95% without condensation at 40 Internal Power Consumption 26 W 20 W Total Power Max. Power Consumption 100 Watt/190 Watt (Heating D-Lamp for 20 seconds) Power Requirements: 110-240V 50/60 Hz (24VDC for DH-2000-BAL-TTL-24V) Remote Lamp Enable and Shutter Enable Requirements I= 2.6 ma at 2.5V I = 8.1mA at 5V Weight Size Approximately 6 kg 150 x 135 x 319 mm *Warm-up time @23 C ambient, free airflow, no vibrations 8 355-00000-000-01503

2: DH-2000 Specifications Output Power Deuterium Bulb Only Tungsten-Halogen B u l b O n l y DH-2000-FHS 217 μw 295 μw DH-2000-DUV 585 μw 990 μw DH-2000-BAL 194 µw 615 µw * Typical output power coupled into a 600 μm UV/VIS fiber and measured with an optical power meter integrated from 200 1100 nm Modification of device specifications and designs to improve performance may occur without notice. 355-00000-000-01 9

2: DH-2000 Specifications Parts List Description Balanced Deuterium Tungsten-Halogen Source, 210-2500nm Balanced Deuterium Tungsten-Halogen Source, 24Vdc, 210-2500nm Deep UV Deuterium Tungsten-Halogen Source, 190-2500 nm Deep UV Deuterium Tungsten-Halogen Source with integrated filter holder, 190-2500nm Fuse Deuterium Bulb Tungsten-Halogen Bulb Part Number DH-2000-BAL DH-2000-BAL-TTL-24V DH-2000-S-DUV-TTL DH-2000-FHS-DUV-TTL Littlefuse 0218002.HXP DH-2000-BD DH-2000-BH Deep UV Deuterium Bulb DH-2000-DUV-B 10 355-00000-000-01503

2: DH-2000 Specifications Pinout Information The following table contains pinout information for the DH-2000 Light Sources: Pin Description 1 Must be pulled up by use to 2.6V to 5 Volts 2 Deuterium Lamp Turns the Deuterium Lamp on/off when 2.6V to 5V is applied to the pin (Rising Edge ON, Rising Edge OFF). * 3 Halogen Lamp - Turns the Halogen Lamp on/off when 2.6V to 5V is applied to the pin (Rising Edge ON, Rising Edge OFF). * 4 Light Source Ground 5 HAL_BAD: In the event the Halogen lamp is bad, this will be active low, otherwise it will be hi. This equates to the Red Halogen LED on the front. Note this LED usually flashes briefly at power up 6 NA 7 NA 8 D_BAD: In the event the Deuterium lamp is bad, this will be active low, otherwise it will be hi. This equates to the Red Deuterium LED on the front 9 D_GOOD: This is active low when the Deuterium is on. It will toggle at 1 Hz during warm up, just like the Green Deuterium LED on the front 10 Shutter Ground 11 NA 12 NA 13 Lamp Enable Signal (Rising Edge ON, Rising Edge OFF, 2.6V to 5V). * 14 HAL_GOOD: This is active low when the Halogen is on. Just like the Green Halogen LED on the front. 15 SHTR_STAT: Should be active HI if the shutter is OPEN *This pull up is only required to use the OUTPUT signals on pins 5, 8, 9, 14, and 15. The input control signals on pins 2, 3, and 13 do not require this pull up. A label on the rear of the unit also provides pin information. 355-00000-000-01 11

2: DH-2000 Specifications Pinout Diagram 12 355-00000-000-01503

Operating the Lamp Chapter 3 Operating Instructions The following sections provide instructions on operating the deuterium and halogen lamps in the DH-2000 Light Source. The DH-2000 unit must be in a horizontal position for it to work. Starting Main Power To apply main power to the unit, 1. Ensure that the Main Power Switch is OFF. Then, connect the power cord to the Terminal Input on the rear panel of the unit. 2. Turn the Main Power Switch ON. The Power LED lights, indicating that the unit is receiving power. The Status LED blinks momentarily after the main power is switched on. The deuterium and halogen bulbs remain off after power-on; they must be turned on separately. Manual Operation of Lamp Starting the Lamp Press the DEUTERIUM or HALOGEN On/Off switch down to ignite the desired lamp. The LED blinks green until the lamp illuminates (approximately 20 seconds for the deuterium lamp, 1-2 seconds for the halogen lamp.) Deuterium Switch Halogen Switch Deuterium Status LED Halogen Status LED 355-00000-000-01 13

3: Operating Instructions After successful illumination, the two-color LED beneath the lamp s On/Off switch lights up green to indicate that the lamp is on. Should the lamp fail to light, the two-color LED lights up red. This indicates a malfunction of the lamp. Press the On/Off switch again to reset the lamp. See Troubleshooting for more information. WARNING Protective eyewear must be worn when using this equipment - Intense ultraviolet radiation present. Never look directly into the light beam, as this can cause eye damage. Turning the Lamp Off Turn the Deuterium or Halogen lamp off by tapping the appropriate ON/OFF switch. Wait 60 seconds before powering off the unit. Warming Up the Lamp After starting the lamp, it must be followed by a warm-up period. The Deuterium lamp requires 10 15 minutes, while the Tungsten-Halogen lamp requires 5 10 minutes of operation to reach a state of thermal equilibrium. During this warm-up period, the intensity of the output power can vary substantially. If applications require extreme intensity stability, the Deuterium and/or Halogen lamps should be warmed up for an additional 15 minutes. Once warmed up for this amount of time, the lamp will reach specified drift values. Manual Operation of the Shutter The shutter on your DH-2000 device may be operated either manually or remotely by utilizing the shutter switch on the front of the unit. 14 355-00000-000-01503

3: Operating Instructions Shutter Switch Manually set the operating mode of the DH-2000 with the Shutter Switch as follows: OPEN - Shutter open CLOSE - Shutter closed TTL Remote operation of shutter Remote Operation of the LAMP and Shutter For remote operation, plug the D-SUB 15-pin connector into the appropriate socket on your spectrometer. USE ONLY THE CABLE PROVIDED OR A CUSTOM CABLE DESIGNED TO INTERFACE WITH THE PINOUTS AS DESCRIBED IN THE PINOUT INFORMATION SECTION. DO NOT USE A VGA VIDEO CABLE. Set the front panel shutter switch to the TTL position Pin 2 of the connector is the Deuterium LAMP ON/OFF control. Pin 3 of the connector is the Halogen LAMP ON/OFF control. Pin 13 of the connector is the shutter control. (HIGH=OPEN, LOW=CLOSE) Refer to Pinout Information for information on operation of the Lamp and shutter. 355-00000-000-01 15

3: Operating Instructions Operating the Filter Slit (DH-2000-FHS-DUV-TTL only) Procedure 1. Rotate the light beam protection cap to open the filter slit. Filter slit in open position 2. Insert your filter with a maximum size of 1 round or square into the filter slit. 3. Rotate the light beam protection cap to completely close the filter slit, ensuring that no light is being emitted Filter slit in closed position 4. After removing the filter, rotate the protection cap to its closed position. 16 355-00000-000-01503

Halogen Lamp Output Adjustment 3: Operating Instructions The user has an option to adjust the halogen lamp output to optimize the intensity between deuterium and halogen light in UV/VIS applications. On the rear of the unit, there is a variable resister that can be adjusted with a small screwdriver. Voltage Optical Power Halogen adjustment Approx. 5V - 12 V 10% - 100% 355-00000-000-01 17

Chapter 4 Troubleshooting Deuterium Lamp If the power supply or Deuterium lamp does not seem to functioning properly, check the following: Issue Probable Cause Resolution Power switches on, but no LEDs light. Deuterium lamp does not light. The two-color LED under the Deuterium On/Off switch lights up red, indicating an error. Deuterium lamp turns off during operation. Line power not present Fuse defective Deuterium lamp too hot Deuterium lamp life exhausted Deuterium lamp s internal connection plug is not closed correctly. Deuterium lamp too hot Check line voltage Check fuse Allow the Deuterium lamp to cool down (20 minutes). Press On/Off switch again to reset the Deuterium Tungsten- Halogen lamp, then press again to restart. Replace Deuterium lamp Open unit (see Maintenance) and close connector plug. Turn off the unit. Allow the unit to cool down for at least 20 minutes. Once the unit has cooled down, turn the Deuterium lamp back on. 355-00000-000-01 18

4: Troubleshooting Halogen Lamp If the Halogen lamp does not seem to functioning properly, check the following: Issue Probable Cause Resolution Halogen lamp does not work after pressing On/Off switch LED does not light after switching on the Halogen lamp Deuterium lamp is warming up Halogen lamp is defective Internal power supply is defective Wait until the Deuterium lamp has lit and try again Replace the Halogen lamp Disconnect the unit from the main power source and contact your dealer for repair or replacement 355-00000-000-01 19

Appendix A Maintenance Overview Bulb Replacement You can manually change the Deuterium and Halogen bulbs in the DH-2000. To order replacement bulbs for the DH-2000, order the following item number(s): Deuterium Spare Bulb (210 400 nm): DH-2000-BD Deuterium Spare Bulb Deep UV (190 400 nm): DH-2000-DUV-B Halogen Spare Bulb (300 1500 nm): DH-2000-BH WARNING Before replacing the bulb in the DH-2000, disconnect the lamp from your power source and allow the unit to cool for at least twenty minutes. Do not touch the lamp glass directly, as contact with bare fingers will reduce the lifetime of the bulb. Both the deuterium and tungsten-halogen bulbs have a typical life of 2000 hours. A good practice recommendation is to change both bulbs at the same time. 355-00000-000-01 20

Replacing the Deuterium Bulb for All Models Except DH-2000-BAL Appendix: Maintenance Procedure 1. Open the six slotted screws (14) and open the casing cover. 2. Open the screws (15) with the tool (18) that is delivered with the spare bulb (16). 3. Disconnect the old bulb and connect the new Deuterium Tungsten-Halogen lamp only with the originally supplied connection plugs (17). Replacing the Deuterium Bulb for DH-2000-BAL Model Procedure 1. Open the six slotted screws (14) and open the casing cover and rotate or remove the cover to expose the bulb housing 355-00000-000-01 21

Appendix: Maintenance 2. Open the screws (15) with the tool (18) that is delivered with the spare bulb (16). 3. Disconnect the old bulb and connect the new Deuterium lamp only with the originally supplied connection plugs (17). 4. Reassemble the lamp housing by reversing Steps 1-3. Replacing the Halogen Bulb for All Models Except DH-2000-BAL Procedure 1. Open the six slotted screws (14) and open the casing cover. 22 355-00000-000-01503

Appendix: Maintenance 2. Remove the screw (21) with the tool (20) provided with the spare bulb (19). 3. Disconnect the old Halogen bulb from the connection plugs (18) 4. Open the screws of the cable-clamp on the lamp-side and remove the defective Halogen lamp module. 5. Insert the new Halogen lamp module and Replace the screw (21). 6. Reattach the two cables of the Halogen lamp module to the cable-clamp. To do this, attach the Halogen lamp s blue cable to Port 1 and the black cable to Port 2 of the connector. 355-00000-000-01 23

Appendix: Maintenance Replacing the Halogen Bulb for DH-2000-BAL Model Procedure 1. Open the six slotted screws (14) and open the casing cover. 2. Remove the screw (21) with the tool (20) provided with the spare bulb (19). 3. Disconnect the old Halogen bulb from the connection plugs (18) 4. Open the screws of the cable-clamp on the lamp-side and remove the defective Halogen lamp module. 5. Insert the new Halogen lamp module and Replace the screw (21). 6. Reattach the two cables of the Halogen lamp module to the cable-clamp 24 355-00000-000-01503

Appendix: Maintenance 7. Reassemble the unit by reversing the disassembly steps. 355-00000-000-01 25

Appendix: Maintenance Warranty Service To initiate warranty service, navigate to: https://oceanoptics.com/support/rma/ to obtain a RMA (Return Merchandise Authorization) number. It is very important that you obtain a RMA number. Please DO NOT SHIP merchandise to Ocean Optics, Inc. without prior authorization. 26 355-00000-000-01503

Index B bulb replacement, 20 cable connection fiber optic, 2 certifications, vi components, 4 front panel, 5 rear panel, 6 connecting the fiber optic cable, 2 document audience, iii purpose, iii summary, iii fiber optic cable connecting, 2 filter slit, 16 lamp adjustment, 17 starting, 13 turning off, 14 warming up, 14 lamps, 13 C D F L maintenance, 20 M O operating environment, 4 package contents, 2 parts list, 10 pinouts, 11 product-related documentation, iv P S setup, 1 shutter, 14 automatic operation, 15 specifications, 4, 8 T troubleshooting table, 18 TTL shutter, 15 U unpacking procedure, 1 upgrades, iv W warranty, v warranty service, 26 what's new, iii 355-00000-000-01 27