Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Similar documents
Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model FSD-331 Combination Fire Smoke Dampers

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model FSD-212. Combination FIRE SMOKE DAMPERS

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

VCD-23. Low Leakage CONTROL DAMPER

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

VCD-23 Low Leakage CONTROL DAMPER

Model VCD-20 3V CONTROL DAMPER

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

Model VCD-43 Extruded Airfoil Blade Control Damper

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

VCD-23. Flange Options. Size Limitations

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

AMD-33 Air Measuring Station with VCD-33 Control Damper

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Thermal Isolation. Break

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

HCD-230 Industrial Control Damper

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Fusible Link (replaceable) Horizontal Mount

Fusible Link (replaceable) Horizontal Mount

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

HVAC Control & Balancing Dampers

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

SD-1250 and SD-1600 Series Smoke Dampers

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

HVAC Control & Balancing Dampers

Air Measuring Products AMD AMS IAQ

FSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

Installation, Operation and Maintenance Manual

Motorized Fire Dampers

5995 Greenwood Plaza Blvd. Suite 100 Greenwood Village, CO (fax)

HVAC Control Damper Models VCD and MBD. Selection Construction Performance

Installation, Operation and Maintenance Manual

Life Safety Dampers. Fire Combination Fire Smoke Smoke Ceiling Radiation

CFSD Series. Product Description

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

Fire, Smoke, and Combination Fire Smoke Dampers

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

Blast Protection Damper

SMOKE DAMPER - CLASS F MODEL BMSD

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

Series HCD Airfoil Control Damper

LOW LEAKAGE VOLUME CONTROL DAMPER

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

Blast Protection Damper

Fire Dampers Catalogue

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

FOR USE IN SOLUTION AIR HANDLING UNITS

MULTI-BLADE FIRE DAMPERS

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

BC Motorized Fire Smoke Dampers MSFD-GB-30C1-A MSFD-GB-30C1-A LISTED

AIR DUCT ACCESSORIES

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

Life Safety Dampers - International. Fire Combination Fire Smoke Smoke Ceiling Radiation

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

ARROW INDUSTRIAL PRODUCTS

Introduction to Johnson Controls Dampers

SECTION CONTROL DAMPERS

BD-1600 Balancing/Zone Control Damper

ID-141x 12-Gauge Hat Channel Industrial Damper

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400

Installation, Operation, and Maintenance Instructions

MULTI-BLADE FIRE DAMPERS

Part # Installation,Operation and Maintenance Instructions

SECTION DUCTWORK ACCESSORIES

Transcription:

Model Application The is a leakage rated smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model serves the function of both a control damper and smoke damper. The may be installed vertically (with blades running horizontal) or horizontally and is rated for airflow and leakage in either direction. Ratings Leakage Class: Operational Rating Maximum : Maximum Pressure: Maximum Temperature: Construction Frame Material Frame Material Thickness Frame Type Blade Material Blade Material Thickness Blade Type Linkage Axle Bearings Axle Material Blade Seals Jamb Seals Size Limitations W x H Size I 4,000 fpm (20.3 m/s) 8 in. wg (2 kpa) 350 F (177 C) Single Section Standard Galvanized Steel 16 ga. (1.5mm) 5 in. x 1 in. (127mm x 25mm) hat channel Galvanized Steel 14 ga. (2mm) Equivalent Double Skin Airfoil Plated Steel Out of Airstream, Concealed in Jamb 304SS Plated Steel Silicone 304SS Maximum Size* Multiple Section Inches 8 x 6 32 x 50 192 x 100 mm 203 x 152 813 x1270 4877 x 2540 Note: Maximum sizes are dependent on velocities and pressures. LH W* Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I *W and H dimensions furnished approximately 1 4 in. (6mm) undersize. Add sleeve thickness for overall sleeved damper dimension. Right hand is shown. Left hand drive is available. RH Model meets the requirements for smoke dampers established by: National Fire Protection Association NFPA Standards 92A, 92B, 101, & 105 International Building Codes (IBC) CSFM California State Fire Marshal Leakage (Smoke) Damper Listing (#3230-0981:0104) New York City (MEA listing #260-91-M) H* Features Frames are constructed with reinforced corners. Low profile head and sill are used on sizes less than 17 in. (432mm) high Blades are double skin airfoil shape of galvanized steel with full length structural reinforcement Actuators: 120V, 24V, 230V, Pneumatic See complete marking on product. UL 555S Classification R13317 Installation instructions available at www.greenheck.com.

Options and Options for : Factory mounted accessories: - Access Doors - Quick Connect breakaway connections - Retaining angles - S & Drive connections Greenheck Test Switches (GTS-3 and GTS-4) Momentary test switch POC retaining angles OCI (Open Closed Indication Switches) Sealed transitions and sleeves Security bars Smoke detectors Transitions: R, C, O This pressure drop testing was conducted in accordance with AMCA Standard 500-D using the three configurations shown. All data has been corrected to represent standard air at a density of.075 lb/ft 3 (1.2 kg/m 3 ). Actual pressure drop found in any HVAC system is a combination of many factors. This pressure drop information along with an analysis of other system influences should be used to estimate actual pressure losses for a damper installed in a given HVAC system. AMCA Test Figures Figure 5.2 Illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. D 4 (W) (H) 3.14 Figure 5.3 Illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. 6D Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system.

Data AMCA Figure 5.2 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36in. x 36 in. (914mm x 914mm) 12in. X 48 in. (305mm x 1219mm) 48 in. x 12 in. (1219mm x 305mm) 500 0.03 500 0.01 500 0.01 500 0.01 500 0.02 1000 0.11 1000 0.06 1000 0.05 1000 0.05 1000 0.08 1500 0.24 1500 0.12 1500 0.12 1500 0.12 1500 0.18 2000 0.42 2000 0.22 2000 0.21 2000 0.21 2000 0.33 2500 0.66 2500 0.34 2500 0.32 2500 0.33 2500 0.51 3000 0.95 3000 0.49 3000 0.47 3000 0.48 3000 0.74 3500 1.30 3500 0.67 3500 0.63 3500 0.65 3500 1.00 4000 1.70 4000 0.87 4000 0.83 4000 0.85 4000 1.31 AMCA Figure 5.3 6D 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36in. x 36 in. (914mm x 914mm) 12in. X 48 in. (305mm x 1219mm) 48 in. x 12 in. (1219mm x 305mm) 500 0.01 500 0.01 500 0.01 500 0.01 500 0.01 1000 0.06 1000 0.02 1000 0.02 1000 0.03 1000 0.04 1500 0.13 1500 0.06 1500 0.05 1500 0.06 1500 0.10 2000 0.23 2000 0.10 2000 0.09 2000 0.11 2000 0.18 2500 0.37 2500 0.16 2500 0.14 2500 0.18 2500 0.29 3000 0.53 3000 0.23 3000 0.21 3000 0.25 3000 0.42 3500 0.73 3500 0.32 3500 0.29 3500 0.34 3500 0.57 4000 0.95 4000 0.42 4000 0.38 4000 0.45 4000 0.74 AMCA Figure 5.5 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36in. x 36 in. (914mm x 914mm) 12in. X 48 in. (305mm x 1219mm) 48 in. x 12 in. (1219mm x 305mm) 500 0.04 500 0.03 500 0.03 500 0.03 500 0.03 1000 0.18 1000 0.13 1000 0.12 1000 0.12 1000 0.14 1500 0.42 1500 0.29 1500 0.27 1500 0.27 1500 0.32 2000 0.75 2000 0.52 2000 0.48 2000 0.49 2000 0.57 2500 1.17 2500 0.81 2500 0.75 2500 0.77 2500 0.89 3000 1.68 3000 1.17 3000 1.08 3000 1.11 3000 1.28 3500 2.29 3500 1.60 3500 1.48 3500 1.51 3500 1.75 4000 2.09 4000 2.14 4000 1.93 4000 1.97 4000 2.29 Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to air performance ratings only.

Application Data Space Envelopes Required for Actuators and Accessories Externally mounted actuators always require space outside of the damper sideplate or sleeve. The S dimension illustrates the clearance required for various available actuators. On dampers less than 18 in. (457mm) high, actuators may also require clearances above and/or below the sideplate or sleeve. B and T dimensions are worst case clearance requirements for some dampers less than 18 in. (457mm) high. All damper sizes under 18 in. (457mm) high do not require these worst case clearances. If space availability above or below the damper sleeve is limited, each damper size should be individually evaluated. S T* B* Actuator Type/Model B* T* S With RRL, RRL/OCI, or TOR With RRL, RRL/OCI, or TOR 120 Volt AC No PiggyBack FSLF120 (-S) Belimo 3 1 2 in (89mm) 0 6 in. (152mm) NA FSNF120 (-S) Belimo 12 3 4 in. (324mm) 0 6 in. (152mm) 9 in. (229mm) FSTF120 (-S) Belimo 3 1 2 in. (89mm) 0 6 in. (152mm) NA ML4XXX Series Honeywell 4 3 4 in. (121mm) 0 6 in. (152mm) NA MS4X09 Series Honeywell 4 3 4 in. (121mm) 0 6 in. (152mm) NA MS4120 Series Honeywell 12 3 4 in. (324mm) 0 6 in. (152mm) 9 in. (229mm) 24 Volt AC FSAF24 (-S) Belimo 12 3 4 in. (324mm) 0 6 in. (152mm) NA FSAF24-BAL (-S) Belimo 12 3 4 in. (324mm) 0 6 in. (152mm) NA FSLF24 (-S) Belimo 3 1 2 in (89mm) 0 6 in. (152mm) NA FSNF24 (-S) Belimo 12 3 4 in. (324mm) 0 6 in. (152mm) 9 in. (229mm) ML8XXX Series Honeywell 4 3 4 in. (121mm) 0 6 in. (152mm) NA MS8X09 Series Honeywell 4 3 4 in. (121mm) 0 6 in. (152mm) NA MS8120 Series Honeywell 12 3 4 in. (324mm) 0 6 in. (152mm) 9 in. (229m) 230 Volt AC FSLF230 (-S) Belimo 3 1 2 in (89mm) 0 6 in. (152mm) NA FSNF230 (-S) Belimo 12 3 4 in. (324mm) 0 6 in. (152mm) 9 in. (229mm) ML4XXX Series Honeywell 4 3 4 in. (121mm) 0 6 in. (152mm) NA MS4X09 Series Honeywell 4 3 4 in. (121mm) 0 6 in. (152mm) NA MS4620 Series Honeywell 12 3 4 in. (324mm) 0 6 in. (152mm) 9 in. (229mm) Pneumatic (25 psi min.) 331-4551 Siemans 7 1 2 in. (191mm) 0 6 in. (152mm) NA 331-2976 Siemens 12 3 4 in. (324mm) 0 6 in. (152mm) NA 331-2856 Siemens 2 1 2 in. (64mm) 0 9 in. (229mm) NA Yes * For dampers 18 in. (457mm) or more in height these dimensions are 0 in..

Application Data Damper Sideplate and Sleeve Dimensional Data Sideplate The drawings illustrate the factory standard sideplate and sleeve mountings for the. The standard A dimensions listed in the table provide adequate space for the mounting of actuators and controls. If space constraints are a problem the A dimension can be varied between 5 3 8 in. (136mm) and 12 in. (305mm). 6 in. (152mm) "A" Dimension in. (mm) Standard Sleeve Maximum Sideplate All Dampers* 7 3 16 (183) 12 (305) 6 3 16 (157) When height is 11 in. (279) or less with OCI 11 3 16 (284) 12 (305) 10 3 16 (259) A 5 in. (127mm) Sideplate Length Sleeve 11/2" max. *With the exception of dampers 11 in. (279mm) high or less, 12 in. (305mm) high or less if width is greater than 64 in. (1625mm) with OCI option. ** On dampers 11 in. (279mm) high or less, 12 in. (305mm) high or less if width is greater than 64 in. (1625mm) with OCI option, sideplate is 16 in. (406mm). Varies 3 3 /4" 5 3 /8" Sleeve Length Damper Sizing Information Dampers larger than maximum single section size are supplied as a factory assembly of two or more sections of equal size. The following figures show damper sections and assemblies that have been qualified for operation with a single actuator. Larger size can be accommodated using multiples of these assemblies. A 5" Single Section Double Section 50 in. (1270mm) 50 in. (1270mm) 32 in. (813mm) 32 in. (813mm) 64 in. (1626mm)

Transitioned Damper Dimensions When a smoke damper is being used in conjunction with round or oval ductwork, the can be supplied in a factory sleeve with round or oval transitions on both ends of the sleeve. Dampers should be ordered to the duct dimensions. Drawings below show overall damper size. D* + 2 in. (51mm) +Ts W* + 2 in. (51mm)+T s W* + 2 in. (51mm)+T s D* + 2 in. (51mm)+T s 2 1/8 in. (54mm) H* + 2 in. (51mm)+T s 2 1/8 in. (54mm) H* H* + 2 in. (51mm)+T s 2 1/8 in. (54mm) H* 16 in. (406mm) D* 16 in. (406mm) W* 16 in. (406mm) W* TYPE R TYPE O * These dimensions are furnished approximately 1 4 in. (6mm) undersize, except round and oval dimensions which are approximately 1 8 in. (3mm) undersize. Ts = (2)(Sleeve Thickness) TYPE C Specifications Smoke dampers meeting the following specifications shall be furnished and installed where shown on plans and/or as described in schedules. Dampers shall meet the requirements of NFPA 92A, 92B, 101, and 105 and further shall be tested, rated and labeled in accordance with the latest edition of UL Standard 555S. Smoke dampers shall be of low leakage design qualified to UL 555S Leakage Class I. Each damper/actuator combination shall have a UL 555S elevated temperature rating of 250 F (121 C) minimum and shall be rated operate at maximum design air flow at its installed location. Each damper shall be supplied with an appropriate actuator installed by the damper manufacturer at the time of damper fabrication. Damper actuator shall be (specifier select one of the following) electric type for 120 (24 or 230) volt operation or pneumatic type for 25 psi minimum (30 psi maximum) operation. Damper blades shall be of the double skin airfoil type and shall have an equivalent metal thickness of 14 ga. (2mm). Damper frame shall be galvanized steel formed into a structural hat channel shape with reinforced corners. Bearings shall be 304SS rotating in extruded holes in the damper frame. Blade edge seals shall be silicone rubber designed to inflate and provide a tighter seal against leakage as pressure on either side of the damper increases. Jamb seals shall be stainless steel compression type. Blades shall be completely symmetrical relative to their axle pivot point, presenting identical resistance to airflow in either direction or pressure on either side of the damper. Damper must be rated for mounting vertically (with blades running horizontal) or horizontally and be UL 555S rated for leakage and airflow in either direction through the damper. The basis of design is Greenheck Model. Copyright 2017 Greenheck Corporation Rev. 13 May 2017