Cleanshield HEPA 550 Owner s Manual

Similar documents
X-3400A, X-3500, X-3700 OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS

PHOENIX GUARDIAN H. E. P. A. SYSTEM

HEPA AIR FILTRATION SYSTEM

Quest H5. Quest Dry. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. Quest H5:

Owner s Manual Phoenix GuardianR

PHOENIX MINI-GUARDIAN

Owner s Manual Phoenix Guardian HEPA System

1200 Portable Air Scrubber Model PRED1200 INSTRUCTION MANUAL

we make clean air Air Filtration Solutions Industrial Commercial Residential quatroair.com AIR TECHNOLOGIES INC.

INSTALLATION GUIDE. Greentek. Residential use only MODEL HS 3.0

INSTRUCTION MANUAL D ABATEMENT TECHNOLOGIES, INC. U.S. PATENT D CANADIAN PATENT Abatement Technologies, Inc.

Owner s Manual Phoenix Guardian HEPA System

AMAIRCARE HEPA BYPASS AIR FILTRATION SYSTEM READ AND SAVE THESE INSTRUCTIONS! AIR CLEANERS/ FILTERS. Rules for Safe Installation and Operation

Quest DRY 150. Quest PowerHEPA 500. quest. Read and Save These Instructions. Quest PowerHEPA 500:

600 Portable Air Scrubber Model PRED600 INSTRUCTION MANUAL

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

OWNER S MANUAL MODEL FSHEPA375 WHOLE-HOUSE TRUE HEPA AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

Airistar 100GT Owner s Manual Airistar 100GT Air Purifier

AIR FILTRATION DEVICE

INSTRUCTION MANUAL. Abatement Technologies, Inc./Remediation Products Division. Abatement Technologies, Inc. Georgia, USA

1200 Portable Air Scrubber Model PRED1200UV INSTRUCTION MANUAL

TOTALINE ELECTRONIC AIR CLEANERS

HEPA-AIRE PORTABLE AIR SCRUBBER-PAS1800 INSTRUCTION MANUAL

Air Purifiers Product Guide


PLANNING THE INSTALLATION

PUREAIR AIR PURIFICATION SYSTEM PHOTOCATALYTIC OXIDATION (PCO) TECHNOLOGY

Owner s Manual Phoenix Mini-Guardian HEPA System

Specialists in HEPA Filtration and Negative Air Machines

KenkoAir_Purifier manual ENG-FR_FDA 10/12_Air Filter manual 8/15/13 10:44 AM Page 1 OPERATING MANUAL

Omniaire 1000V Instruction Manual-8/05

Miracle State Of The Art Air Filtration System!

H2KM and H2KMA. Instruction Manual. Abatement Technologies, Inc. Abatement Technologies, Ltd. Georgia, USA. Ontario, Canada

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

INSTALLATION & OPERATION MANUAL

INSTALLATION / OPERATION / MAINTENANCE GUIDE

EPG Air Cleaners. Durable, Corrosion-Free Air Cleaner Improved Reliability, Superior Engine Protection, Easiest Serviceability

BULLDOG PORTABLE AIR FILTRATION UNIT Models BD2KL and BD2KLA INSTRUCTION MANUAL

MODEL FA5 Air Filtration System. Operations Manual

Portable filtration unit / 650 CFM (305 L/s) Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

Important Safety Instructions...2. Technical Specifications...2. Parts Description...3. Operating Instructions...4. Programming Instructions...

FA1 Series Air Filtration System. Operations Manual

Videojet Fume Extractor Preventive Maintenance Guide

MODEL SAFETY & INSTRUCTION MANUAL

FPG & FPG Alexin Air Cleaners

User Manual. Model: FSL300 Dual Port Laser Fume Extractor

Affordable portable filtration unit

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

BULL 240 EBS INDUSTRIAL VACUUM. Operator s Manual VAC.BULL240.EBS. SASE Company, LLC 2475 Stock Creek Blvd. Rockford, TN 37853

MIATECH SOLUTIONS, A PIECE OF THE PUZZLE. Bio Turbo 300. Bio Turbo 1000

For Mini Split Units. Cleaner, Fresher Air in 24 Hours New Advanced Environmental Air Treatment System

MODEL FA1 Mini Air Filtration System. Operations Manual

Multistage Air Filtration Systems Instruction Manual

WELCOME. Important Safety Instructions...2. Technical Specifications...2. Parts Description...3. Operating Instructions...4

Air Boss M-Series Media & Adsorption Air Cleaner

Cummins and Fleetguard are registered trademarks of Cummins, Inc. Mann+Hummel is a registered trademark of Mann+Hummel GMBH

AeraMax Pro AM IV. Please read these instructions before use. Do not discard: keep for future reference.

Caution: A properly installed, undamaged foam filter is required for proper operation.

FPG & FPG Alexin Air Cleaners

FNCCAB & FILBBFNC Sizes 014, 017, 021 & 024

Portable Air Purifiers

Installation & Service Manual for Portable Fume Collector. Model PFC-800

Making copies of this manual for any purpose other than your own personal use is a violation of the United States copyright laws.

I-6500 Series. Industrial Applications. Operations & Maintenance Manual. Air Purifiers for. Manufactured. Serial number.

OmniAire Portable Air Cleaner OA1200PAC

Our older, classic EBA cowl-mounted air cleaner (shown on the right) has been replaced with our ERA Air Cleaner.

SPH General Manual 400 Series

A properly installed, undamaged foam filter is required for proper operation.

OWNER S MANUAL MODELS EADM900UV-VO-A & EADM900UV-VO-VS WHOLE-HOUSE DUCT MOUNT HEPA AIR CLEANER WITH ULTRAVIOLET LAMP & PHOTO CATALYTIC FILTER

PowerPleat Air Cleaners

MODEL GS1-100 Air Filtration System. Operations Manual

Cleaner, Fresher Air in 24 Hours New Advanced Environmental Air Treatment System For PTAC & ETAC Units

FILCAB, FILCAR & EZ Flex Sizes 016, 020, 024

Product Data. FNCCAB & FILCCFNC High Efficiency Fan Coil Filtration. Sizes 014, 017, 021 & 024. FNCCAB Filter Cabinet. FILCCFNC Media Filter

EXT DUCTLESS FUME HOOD

ELECTRICAL SAFETY. Safety Training For The Non-Qualified

CA111 (Series 1,2,3) In Ceiling Media Air Cleaner

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

/ 120-VOLT ELECTRICAL SYSTEM

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01

PowerPleat Air Cleaners

Air Bear Supreme and Air Bear Cub. Media Air Cleaners READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

Product Data. FILCAB, FILCAR & EZ Flex Efficient Mechanical Air Cleaner. Sizes 016, 020, 024. FILCAB Filter Cabinet. FILCAR Media Filter

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

Flow Max Fluid Pump. by Duraself OEM INSTALLATION MANUAL

Rev: Flow Max 115V AC Fluid Pump

OPERATIONAL INSTRUCTIONS

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

HRC06 OWNER S MANUAL HYDROXYL ROOM CURTAIN

There are two general ways to capture airborne pollutants:

Simple Smart Screen This space-saving yet powerful central vacuum system combines the same high performance

OWNER S MANUAL C O M M E R C I A L I N D O O R A I R Q U A L I T Y S O L U T I O N S. Total High Efficiency Particulate & Gaseous Filtration System

OPERATIONAL INSTRUCTIONS

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BVX-100. Fume Extraction System _B

MODELS: CAP600-UVP AND CAP600-UV INSTRUCTION MANUAL

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

CRYSTAL-AIRE. concealed commercial air cleaners

Transcription:

Cleanshield HEPA 550 Owner s Manual READ AND SAVE THESE INSTRUCTIONS E-mail: sales@alorair.com Add: North Carolina USA

Caution! Don t adjust or alter the Cleanshield HEPA 550 in any way.use the parts approved by ALORAIR Company. Adjustments or utilization of unapproved parts could void your warranty. Contact approved distributor for help. Clean Shield HEPA 550 Key Features WARNING! FIRE AND ELECTRIC SHOCK DAMAGE Control Panel Located opposite of the side showing Handle Unit must be electrically grounded. Insert 3-prong plug directly to outlet with Ground Fault Circuit Interrupting device. Adapter is not allowed to be used in the unit Removable foam cap (with cap leash) Latches (4 total) Wiring and motor operation Do not use the unit in standing water. If electrical parts get wet, must dry them before using. USE AND OPERATION The CleanShield HEPA 550 is a convenient filtration system that can clean air coming from Inlet (ductable,12") Inlet panel, removable Outlet outside environment through advanced filters. The unit expels airborne particles like mold spores, dust, pollen, pet dander and incidental garbage. HOW THE CLEANSHIELD HEPA 550 WORKS The CleanShield HEPA 500 uses an effective blend of wind stream and advanced filtration system to make "cleaner" air. The unit's maximum air flow of 550 CFM draws air into the filters of two types - a pre-filter Vertical, upright position and a HEPA filter for filtration. The principal phase of filtration catches bigger particles, and the second phase of filtration catches much littler particles down to 0.3 microns. You can utilize the air scrubber for water damage restoration, sewage restoration, fire Retaining Clips (2 per side,8 total) damage restoration, etc.. -1- -2-

INSTRUCTIONS SETUP 1. Put the Cleanshield HEPA 550 upright. 2. Plug to a standard 115 volt outlet. Each unit needs 3 amps to operate. 3. Power the unit on, adjusting speed by twisting the variable speed switch. The maximum speed is 550 CFM and the minimum speed is 270 CFM. 4. The Cleanshield HEPA 500 is multi-positional. THE CONTROL PANEL: Variable Speed Control Note that the MAX speed setting is located immediately under of the OFF button, you can turn to minimum speed by anticlockwise turn. The Auxiliary Outlet You can daisy chain up to 3 same units to satisfy your air filtration needs. The maximum value is 12 amps when the unit is turned off, and maximum 9 amps when it is turned on. That means you can plug other equipment into the unit, but the amperage is limited. Red Circuit Breaker Switch Red Circuit Breaker Switch is used to protect the unit when more than 12 amps of electricity passing the circuit. The circuit breaker switch will cut off the power. The Filters The unit's maximum air flow of 550 CFM draws air into the filters of two types - a pre-filter and a HEPA filter for filtration. The principal phase of filtration catches bigger particles, and the second phase of filtration catches much littler particles down to 0.3 microns. Changing filters 1. Loosen the 4 locks that holding the filter board. 2. Slide the filter panel board. 3. Remove the used filters and replace. WARNING: Wear defensive mask when changing filters. Change filters after each remediation work. Change HEPA filters when the indicator light on. Main Uses: APPLICATIONS OF CLEANSHIELD HEPA 550 CleanShield 550 HEPA,a versatile air scrubber and negative air machine that can effectively complete your water damage restoration tasks, mold remediation works,fire damage restoration, dust control, odor control and sewage remediation. Variable Speed Control Red Circuit Breaker Switch For Water Damage For water damage restoration, Cleanshield HEPA 550 be put in the central point of the influenced area. The air scrubber will suck up the encompassing air and give back the filtered air to the same environment. To work the air scrubber, just turn the unit on. It will promptly start sucking up air through various stages of filters and catching airborne particles. When the unit works in huge regions or spaces that are divided by walls, entryways, or lobbies, you may need to put several pieces of air scrubbers in the key areas. The Auxiliary Outlet -3- -4-

For Odor Control CleanShield 550 HEPA air scrubber adopts various stages of filters to satisfy the variable sized contaminants in the air. Activated carbon filter which is placed in the pre-filter stage, is quite capable of capturing a wide variety of odor-casing gas molecules like volatile organic compounds (VOCs), soot and smoke, food odors, fumes from paint and paint thinners, sewer odors, and many other compounds. This activated carbon filter is also used for microscopic particles adsorption and cleaning. Activated carbon material has super adsorption ability. One gram of activated carbon can handle the gaseous odor particles in the surface area sized up to 2,000 sq.ft. Removable intake panel for remediation professionals There s a removable panel on the intake side of the unit. Lift the latches to release the panel. Install the Cleanshield HEPA 500 outside the containment area to draw air out. Cut a hole in the containment plastic the size of the unit s inlet, insert the inlet into the plastic, and seal the circumference tightly with duct tape. A tightly sealed containment area will aid in creating an effective negative pressure. Use a manometer to monitor air pressure. Manometers are available at most equipment supply houses. WARNING: Multi-Positional BREATHING HAZARD When using the Cleanshield HEPA 550 in a containment area, turn off all sources of power to open combustion appliances such as fireplaces, boilers, furnaces,water heaters and You can stack and operate up to two CleanShield HEPA 550 vertically. You can also stack them horizontally for space saving storage. HVAC systems to avoid the risk of backdrafting carbon monoxide fumes. If the Filter Change Light illuminates during the remediation process, immediately change the HEPA filter. TIPPING HAZARD When stacking units,beware of tipping. Do not stack more than 2 units on top of each other. Falling equipment could cause bodily harm. SPECIALIZED USES: Daisy-chain capability You can at most connect together three units to create a maximum of 550, 1100, or 1650 CFM using the auxiliary outlet on the unit s control panel. You can also daisy chain the units in a stacked position. Operation Safety Instruction Before Use: Unplug unit before performing any maintenance. Check the power cord for fraying, cuts or any damage. Do not use the unit if you find any. Check your GFCI outlet. Power on the unit and press the red GFCI "Test" button. If it's working well the "Reset" fasten would pop up. You'll have to press the "reset" button again for operation. Never use a water hose or pressure washer to clean electrical components; water could enter the electrical compartment causing a shock hazard. -5- -6-

Check pre-filter for dust block before use. If there is airflow restriction, please change for a new filter. When using the Cleanshield HEPA 550 for remediation: Replace both the filter to avoid cross-pollution. Clean the unit after remediation to avoid cross-pollution in next remediation work.. Make sure the unit is dry before installing clean filters. -7-