Keatec Energy Catalogue 2018 Telecommunications

Similar documents
TLE Series UPS 400/500 kw With eboost Technology

TLE Series UPS 160/200/225/250 kw with eboost Technology

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

NetSure. 211 Series DC Power System

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Aurora Single Phase Emergency Lighting Inverters

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

TLE Series UPS 750/1000 kw With eboost Technology

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

TECHNICAL DATA SHEET KVA UPS Systemss

Technical Data Sheets

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Industrial Chargers and

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

3 Uninterruptible Power Systems

AT30 SERIES BATTERY CHARGER

POWER kva

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Technical Data Sheets

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

POWER kva

PowerValue 11/31 T kva

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

EFFEKTA Power Supplies

Power+ CLASSIC. 20/30 kva, 3x208 Vac

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Technical Data Sheets

QUEENSLAND URBAN UTILITIES

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Technical Data Sheets

Technical data sheets

Technical Specification SENTINEL PRO

Pure Lead-Tin Technology

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Three Phase UPS Systems Range: 10 to 500kVA

Industrial Power Supplies

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

POWERTRONIX QUASAR 5-40 KVA

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

AT EVO SERIES BATTERY CHARGER

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

PowerWave 33 Efficient power protection for today s IT and process-related work environments

720 W / 24 V On-board Battery Charger. for industrial applications. Product Data Sheet

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Uninterruptible Power Systems

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

X600. Technical Sheet

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

3 Uninterruptible Power Systems

EVO AT SERIES BATTERY CHARGER

RELIABLE SOLUTIONS in POWER ELECTRONICS. Power Management Instruments RDAT SERIES BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

nonstopower sdn bhd ( P) Power Management Instruments DC Battery Charger / Automation Type RELIABLE SOLUTIONS in POWER ELECTRONICS

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc

Liebert Hipluse U UPS;80-400kVA; 380/400/415V Detailed Specification

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

CPS2000 Cabinet Power System

DPP/3DPP. Digital ProcessPower UPS INDUSTRIAL PWM UNINTERRUPTIBLE POWER SUPPLY SYSTEM SINGLE PHASE THREE PHASE

ATevo SERIES BATTERY CHARGER

Illuminator Series CR NEMA 3R

MTPi2000C - 80 KW (RANGE)

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Haze Battery Company Ltd

AT SERIES EVO BATTERY CHARGER

Technical data sheets

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

FAT. FAT Battery Range FIAMM.COM

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

DC POWER SUPPLY SYSTEMS

KEPCO Will Point You In The Right Direction!

Security Plus Online Uninterruptible Power Supply

Transcription:

Keatec Energy Catalogue 2018 Telecommunications Keatec Energy designs, manufactures, installs and services DC and AC uninterruptible power solutions for Telecommunication, Commercial Information Technology (IT), Public Safety and Industrial clients across the Americas.

Tle o on en e ol e e ol e e onolle o e hel e o e l n e ol n ee nlone n ee ll ell o e oo e e on Te n l ee ee h on ee ee e n en n e ee n e on o o e e ee e p n eo n e e e en e e Telephone le n hooo e o n e n n e no ol n e e o e o Telephone ee ene o le ee ene o

RECTIFIER MODULE NESPACE Series Rectifer Module 2 kw 42 A 48 Vdc NESPACE Rectifier Modules deliver outstanding reliability and world-leading power density. Ideally suited for 48V telecom and other applications where wide input voltage ranges and high operating temperatures are required. FEATURES High efficiency and power density Max efficiency 96% Power density 1.41 W/cm 3 Wide input voltage range 85-296 Vac 1ph Output Voltage vs Output Current Io (A) 41.7 37.0 34.4 High operating temperature range Operating -40 to +75 C, full power -40 to +55 C 42 48 Vo (Vdc) 54 58 High reliability Efficient thermal design and self-protection features ensure high reliability Hot swappable Output Power vs Input Voltage 2000 > Excellent EMC performance Low interference and low susceptibility Po (W) 800 > Worldwide certifications UL and CE 0 > 77 85 176 Vi (Vac) 285 > 297 keatecenergy.com

RECTIFIER MODULE NESPACE Series Rectifer Module 2 kw 42 A 48 Vdc SPECIFICATIONS AC Input Nominal voltage 230 Vac 1ph Range 85-296 Vac 1ph Frequency 45~66 Hz Inrush 20 A at nominal input, full load Efficiency Up to 96% Power factor >0.99 at 50% load or more Protection Under and over voltage Mains fuse in both lines DC Output Nominal voltage Range Output power Output current Line regulation Load regulation Ripple and noise Protection 54.0 Vdc 42.0-58.0 Vdc 2000 W at >176 Vac input 1262 W at 120 Vac input 800 W at 85 Vac input 37 A at 54V, input >176 Vac 23 A at 54V, input 120 Vac 14.8 A at 54V, input 85 Vac + 0.5% Max over entire input range + 0.5% Max over entire load range <250 mv, p-p, <20 mv rms Overvoltage at 59Vdc (recycle input to reset) Power de-rating Thermal shutdown General Specifications Cooling MTBF Acoustic noise Operating temperature Storage temp Humidity Single fan (front to back airflow) >350,000 hours <55 dba (at nominal input and full load, ambient <40 C) -40 to +75 C (-40 to +55 C full load, de-rated above 55 C) -40 to +85 C 95% non-condensing H x W x L mm 41.0 (1U) x 108.0 x 319.9 Weight kg 2.18 Monitoring and NESPACE KA Monitoring Control Unit control Communication CAN Bus protocol Standards Safety IEC 60950-1, UL 60950-1 EMC EN 55022 Class A (emission) IEC 61000-4-2 (electrostatic discharge) IEC 61000-4-3 (radiated immunity) IEC 61000-4-4 (fast transients) IEC 61000-4-5 (surge immunity) IEC 61000-4-6 (conducted immunity) IEC 61000-4-10 (voltage dips) IEC 61000-4-11 (voltage interruptions) IEC 61000-3-3 (fluctuations & flicker) Certification UL, CE, CB Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS NESPACE Series Rectifier Module 2kW 42A 48Vdc English 20161125

RECTIFIER MODULE NESPACE Series Rectifer Module 3 kw 62 A 48 Vdc NESPACE Rectifier Modules deliver outstanding reliability and world-leading power density. Ideally suited for 48V telecom and other applications where wide input voltage ranges and high operating temperatures are required. FEATURES High efficiency and high power density Max efficiency 96% Power density 2.11 W/cm 3 Wide input voltage range 85-296 Vac 1ph Output Voltage vs Output Current Io (A) 62.5 55.5 51.7 High operating temperature range Operating -40 to +75 C, full power -40 to +45 C 20 42 48 Vo (Vdc) 54 58 High reliability Efficient thermal design and self-protection features ensure high reliability Hot swappable Output Power vs Input Voltage 3000 > Excellent EMC performance Low interference and low susceptibility Po (W) 1300 > Worldwide certifications UL and CE 0 > 77 85 176 Vi (Vac) 285 > 297 keatecenergy.com

RECTIFIER MODULE NESPACE Series Rectifer Module 3 kw 62 A 48 Vdc SPECIFICATION AC Input Nominal voltage 230 Vac 1ph Range 85-296 Vac 1ph Frequency 45~66 Hz Inrush 25 A at nominal input, full load Efficiency Up to 96% Power factor > 0.99 at 50% load or more Protection Under and over voltage mains fuse in both lines DC Output Nominal voltage Range Output power Output current Line regulation Load regulation Ripple and noise Overvoltage protection 54.0 Vdc 42.0-58.0 Vdc 3000 W at >176 Vac input 1954 W at 120 Vac input 1300 W at 85 Vac input 55.5 A at 54V, input >176 Vac 36.2 A at 54V, input 120 Vac 24.1 A at 54V, input 85 Vac + 0.5% Max over entire input range + 0.5% Max over entire load range <300 mv, p-p, <20 mv rms Overvoltage at 59 Vdc (recycle input to reset) Power de-rating Thermal shutdown General Specifications Cooling MTBF Acoustic noise Operating temperature Storage temperature Humidity Single fan (front to back airflow) >450,000 hours <55 dba (at nominal input and full load, ambient <40 C) -40 to +75 C (-40 to +45 C full load, de-rated above 45 C) -40 to +85 C 95% non-condensing H x W x L mm 41.0 (1U) x 108.0 x 319.9 Weight kg 2.30 Monitoring and Control Communication protocol NESPACE KA Monitoring Control Unit CAN Bus Standards Safety IEC 60950-1, UL 60950-1 EMC Certification EN 55022 Class A (emission) IEC 61000-4-2 (electrostatic discharge) IEC 61000-4-3 (radiated immunity) IEC 61000-4-4 (fast transients) IEC 61000-4-5 (surge immunity) IEC 61000-4-6 (conducted immunity) IEC 61000-4-10 (voltage dips) IEC 61000-4-11 (voltage interruptions) IEC 61000-3-3 (fluctuations & flicker) UL, CE, CB Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS NESPACE Series Rectifier Module 3kW 62A 48Vdc English 20161125

RECTIFIER MODULE NESPACE Series Rectifer Module Monitoring Control Unit KA NESPACE Monitoring and Control Unit KA enables remote monitoring and control over systems integrating NESPACE Rectifier Modules. FEATURES Faceplate display and control LCD screen, LEDs and four button interface Remote monitoring and control Monitoring and control of up to 32 NESPACE rectifier modules RS232, SNMPv1, SNMPv2c, Modbus Battery management Temperature compensated charging, boost, equalize and current settings, capacity test System management Input and output alarms, low voltage disconnects (LLVD, BLVD) Excellent EMC performance Low interference and low susceptibility Worldwide certifications CE, UL (pending) keatecenergy.com

RECTIFIER MODULE NESPACE Series Rectifer Module Monitoring Control Unit KA SPECIFICATION Functions System control and monitoring Battery management Compatible rectifiers Remote Monitoring and Control External communication Control up to 32 rectifiers LVD functions Configurable alarms and settings Event log (1000 entries) Password management Temperature compensation Low voltage disconnect Capacity test Charge current limit Boost and equalize charge settings Nespace Digital Rectifiers RS232, TCP/IP, Ethernet, SNMPv1, SNMPv2, Modbus General Specifications Cooling Convection MTBF > 250,000 hrs Operating temperature - 40 to 75 o C Storage temperature - 40 to 80 o C Humidity (operating) 0 to 90% non-condensing Altitude 2,000 m H x W x L(mm) 41 (1U) x 108 x 319.9 Weight kg 0.3 Standards Certification CE, UL (pending) Features DC input range 42.0-58.0 Vdc Montoring AC input voltage DC output voltage Load current Battery current Battery cabinet temperature Individula module status Battery cell voltages Digital input alarms Up to 8 Digital outputs Up to 8, dry contact (8) LVD BLVD, LLVD Interface LCD, LED, buttons (4) Languages English Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS NESPACE Series Rectifier Module Monitoring Control KA English 20170623

RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 4 kw 83 A 48 Vdc with Distribution NESPACE Series Rectifier Modules in power shelf system with front DC fuse protection, rear DC load connections, dry contact alarms, and a monitoring and control module. Ideally suited for 48V telecom power plants where wide input voltage ranges and high operating temperatures are required. FEATURES High efficiency and power density Max efficiency 96% Two rectifiers up to 4 kw total output Wide input voltage range 85-296 Vac 1Ph High operating temperature range Operating -40 to +75 C, full power -40 to +55 C Advanced battery management Temperature compensated charging Boost, equalize and DC current settings Battery capacity test Flexible, scalable and reliable Hot swappable rectifier modules Front access to 15x DC output fuses Rear access to 15x DC output ports and 15x ground ports Rear access to 6x dry contact alarms RS232 port TCP/IP Ethernet port keatecenergy.com

RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 4 kw 83 A 48 Vdc with Distribution keatecenergy.com

SPECIFICATIONS RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 4 kw 83 A 48 Vdc with Distribution AC Input 4kW Power Shelf (2 x 2kW) AC Supply 1 Phase 3 Wire Nominal Voltage 230 Vac Range 85-296 Vac Frequency 47~63 Hz Efficiency Up to 96% DC Output Nominal voltage Range Output power Output current Line regulation Load regulation Ripple and noise Protection -54.0 Vdc 42.0-58.0 Vdc 4,000 W at >176 Vac input 2,524 W at 120 Vac input 1,600 W at 85 Vac input 74 A at 54V, input >176 Vac 46 A at 54V, input 120 Vac 29.6 A at 54V, input 85 Vac + 0.5% Max over entire input range + 0.5% Max over entire load range <250 mv, p-p Overvoltage at 59 Vdc, thermal shutdown, battery temperature compensation Distribution DC output 15 DC ground 15 Dry contact alarms 6 General Specifications Modules NESPACE 2 kw, NESPACE Monitoring Control Unit KA Communication RS232 for PC, TCP/IP Cooling Forced air Shelf H x W x L mm 44.4 (19 1U) x 446 x 408 Temperature Operating -10 to +75 C, derating of 2 kw module above +55 0 C / Storage -40 to +85 C Altitude < 3000 M Humidity 95% non-condensing Standards: Shelf 60950-1 (pending) Standards: Rectifier UL, CE Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Nespace Series Power Shelf 4kW 83A 48V with Distribution English 2011125

RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 6 kw 125 A 48 Vdc with Bulk Distribution NESPACE Series Rectifier Modules in power shelf system with rear DC bulk output connection, dry contact alarms, digitial inputs, and a monitoring and control module. Ideally suited for 48V telecom power plants where wide input voltage ranges and high operating temperatures are required. FEATURES High efficiency and power density Max efficiency 96% Three rectifiers up to 6 kw total output Wide input voltage range 85-296 Vac 1Ph High operating temperature range Operating -40 to +75 C, full power -40 to +55 C Advanced battery management Temperature compensated charging Boost, equalize and current settings Battery capacity test Flexible, scalable and reliable Hot swappable rectifier modules Rear access to bulk DC output and DC ground Rear access to 6x dry contact alarm ports Rear access to 4 digital input ports RS232 port TCP/IP Ethernet port keatecenergy.com

RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 6 kw 125 A 48 Vdc with Bulk Distribution keatecenergy.com

SPECIFICATIONS RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 6 kw 125 A 48 Vdc with Bulk Distribution AC Input 6kW Power Shelf (3 x 2kW) AC Supply 1 Phase 3 Wire Nominal Voltage 230 Vac Range 85-296 Vac Frequency 47~63 Hz Efficiency Up to 96% DC Output Nominal voltage Range Output power Output current Line regulation Load regulation Ripple and noise Protection -54.0 Vdc 42.0-58.0 Vdc 6000 W at >176 Vac input 3,786 W at 120 Vac input 2,400 W at 85 Vac input 111 A at 54V, input >176 Vac 69 A at 54V, input 120 Vac 44.4 A at 54V, input 85 Vac + 0.5% Max over entire input range + 0.5% Max over entire load range <250 mv, p-p Overvoltage at 59 Vdc, thermal shutdown, battery temperature compensation Distribution DC output 1 DC ground 1 Dry contact alarms 6 Digital inputs 4 General Specifications Modules NESPACE 2 kw, NESPACE Monitoring Control Unit KA Communication RS232 for PC, TCP/IP Cooling Forced air Shelf H x W x L mm 44.4 (19 1U) x 446 x 408 Temperature Operating -10 to +75 C, derating of 2 kw module above +55 0 C / Storage -40 to +85 C Altitude < 3000 M Humidity 95% non-condensing Standards: Shelf 60950-1 (pending) Standards: Rectifier UL, CE Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Nespace Series Power Shelf 6kW 125A 48V with Bulk Distribution English 2011125

RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 9 kw 187 A 48 Vdc with Distribution NESPACE Series Rectifier Modules in power shelf system with input and output alarms, battery low voltage disconnection, DC load distribution, and a monitoring and control module. Ideally suited for 48V telecom power plants where wide input voltage ranges and high operating temperatures are required. FEATURES High efficiency and power density Max efficiency 96% Three rectifiers up to 9 kw total output Wide input voltage range 85-296 Vac 1Ph High operating temperature range Operating -40 to +75 C, full power -40 to +45 C Advanced battery management Temperature compensated charging Boost, equalize and current settings Battery capacity test Flexible, scalable and reliable Hot swappable rectifier modules Two battery breaker postions 125A battery low voltage disconnect Four load distribution breaker postions Six input alarm ports Six output alarm ports TCP/IP Ethernet port keatecenergy.com

RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 9 kw 187 A 48 Vdc with Distribution keatecenergy.com

SPECIFICATIONS RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 9 kw 187 A 48 Vdc with Distribution AC Input 9kW Power Shelf (3 x 3kW) AC Supply 1 Phase 3 Wire or 3 Phase 4 wire Nominal Voltage 230 Vac Range 85-296 Vac Frequency 47~63 Hz Efficiency Up to 96% DC Output Nominal voltage Range Output power Output current Line regulation Load regulation Ripple and noise Protection -54.0 Vdc 42.0-58.0 Vdc 9000 W at >176 Vac input 5,862 W at 120 Vac input 3,900 W at 85 Vac input 166.5 A at 54V, input >176 Vac 108.6A at 54V, input 120 Vac 72.3 A at 54V, input 85 Vac + 0.5% Max over entire input range + 0.5% Max over entire load range <300 mv, p-p Overvoltage at 59 Vdc, thermal shutdown, battery temperature compensation Distribution Battery breakers 2 x 100A BLVD 125 A DC load breakers 2 x 20A, 30A, 50A Input EXT alarm ports 6 Output HW alarm ports 6 DC output points 9 Battery input points 2 x NEG -, 2 x POS + General Specifications Modules NESPACE 3 kw, NESPACE Monitoring Control Unit KA Communication RS232 for PC, TCP/IP, GUI, SNMP Cooling Forced air Shelf H x W x L mm 88.8 (19 2U) x 448.8 x 402 Temperature Operating -10 to +75 C, derating of 3 kw module above +45 0 C / Storage -40 to +85 C Altitude < 3000 M Humidity 95% non-condensing Standards: Shelf 60950-1 (pending) Standards: Rectifier UL, CE Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Nespace Series Power Shelf 9kW 187A 48V with Distribution English 2011125

RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 12 kw 250 A 48 Vdc with Distribution NESPACE Series Rectifier Modules in power shelf system with input and output alarms, battery low voltage disconnection, DC load distribution, and a monitoring and control module. Ideally suited for 48V telecom power plants where wide input voltage ranges and high operating temperatures are required. FEATURES High efficiency and power density Max efficiency 96% Four rectifiers up to 12 kw total output Wide input voltage range 85-296 Vac 1Ph High operating temperature range Operating -40 to +75 C, full power -40 to +45 C Advanced battery management Temperature compensated charging Boost, equalize and current settings Battery capacity test Flexible, scalable and reliable Hot swappable rectifier modules AC input surge suppression Ground current sensing with surge suppression LVLD with surge suppression and up to nine DC MCBs LBVD with two battery MCBs Four DC priority MCBs Eight input alarm ports Eight output alarm ports TCP/IP Ethernet port RS232 keatecenergy.com

RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 12 kw 250 A 48 Vdc with Distribution keatecenergy.com

SPECIFICATIONS RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 12 kw 250 A 48 Vdc with Distribution AC Input 12kW Power Shelf (4 x 3kW) AC Supply 1 Phase 3 Wire Nominal Voltage 230 Vac Range 85-296 Vac Frequency 47~63 Hz Efficiency Up to 96% DC Output Nominal voltage Range Output power Output current Line regulation Load regulation Ripple and noise Rectifier self protection -54.0 Vdc 42.0-58.0 Vdc 12,000 W at >176 Vac input 7,816 W at 120 Vac input 5,200 W at 85 Vac input 222.2 A at 54V, input >176 Vac 144.8 A at 54V, input 120 Vac 96.4 A at 54V, input 85 Vac + 0.5% Max over entire input range + 1.0% Max over entire load range <300 mv, p-p Overvoltage at 59 Vdc, thermal shutdown, battery temperature compensation Distribution AC input protection SPD 20KA Ground protection SPD 6.5KA LVBD (MCB) 260A (2 x 100A) LLVD (MCB) 200A with SPD 40KA (3 x 25A, 1 x 32A, 4 x 63A, 1 x open) DC priority MCB 3 x 10A, 1 x 16A Input alarm ports 8 Output alarm ports 8 General Specifications Modules NESPACE 3 kw, NESPACE Monitoring Control Unit KA Communication RS232, TCP/IP, SNMP Cooling Forced air Shelf H x W x L mm 219.8 x 482 x 403.2 (19 5U) Temperature Operating -40 to +75 C, derating of 3 kw module above +45 0 C / Storage -40 to +80 C Altitude < 2000 M Humidity 95% non-condensing Standards: Shelf 60950-1 (pending) Standards: Rectifier UL, CE Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Nespace Series Power Shelf 12kW 250A 48V with Distribution English 20170706

RECTIFIER POWER SYSTEM NESPACE Series Power Plant 165 kw 3438 A 48 Vdc NESPACE Series Rectifier Modules in power plant system with individual AC input to rectifiers. Monitoring with input and output alarms, and battery low voltage disconnection. AC Input and DC output surge suppression. Ideally suited for 48V telecom power plants. FEATURES High efficiency Max efficiency 96% Advanced battery management Temperature compensated charging Boost, equalize and current settings Flexible, scalable and reliable Dual racks with 55x 3kW rectifiers N+1 redundancy design Individual AC power input per rectifier Hot swappable rectifier modules 1250A battery breakers 1500A battery low voltage disconnects AC and DC surge suppression DC battery bypass Six input alarm ports Six output alarm ports TCP/IP Ethernet port keatecenergy.com

RECTIFIER POWER SYSTEM NESPACE Series Power Plant 165 kw 3438 A 48 Vdc keatecenergy.com

RECTIFIER POWER SYSTEM NESPACE Series Power Plant 165 kw 3438 A 48 Vdc keatecenergy.com

RECTIFIER POWER SYSTEM NESPACE Series Power Plant 165 kw 3438 A 48 Vdc keatecenergy.com

RECTIFIER POWER SYSTEM NESPACE Series Power Plant 165 kw 3438 A 48 Vdc keatecenergy.com

RECTIFIER POWER SYSTEM NESPACE Series Power Plant 165 kw 3438 A 48 Vdc keatecenergy.com

SPECIFICATIONS RECTIFIER POWER SYSTEM NESPACE Series Power Plant 165 kw 3438 A 48 Vdc AC Input 165kW Power Plant (55 x 3kW) AC Supply 3 Phase 4 Wire 380Vca Nominal Voltage 380 Vac Range 305 ~ 514 Vac Frequency 45~66 Hz Efficiency Up to 96% DC Output Nominal voltage -53.5.0 Vdc Range 42.0-58.0 Vdc Output current 3052.5 A at 54 Vdc Line regulation + 0.5% Max Load regulation + 1.0% Max Over current 101 ~ 110% Ripple and noise <300 mv p-p, <2 mvrms Protection Overvoltage at 59 Vdc, thermal shutdown, battery temperature compensation Distribution AC surge suppression 40 kva per rack AC input breaker 225 A 3 P+N per rack Battery bypass Manual bypass switch (on, off, auto) Battery fuse 4 x 1250 A BLVD relay 2 x 1500 A DC load fuse 3 x 1250 A DC bus bar - 48 Vdc 1500 SQ (bus-bar, ground) Input alarm ports 6 Output alarm ports 6 DC surge suppression 6.5 kva per rack General Specifications Modules Communication Cooling H x W x L mm Temperature Altitude Humidity Standards: Rack Standards: Rectifier NESPACE 3 kw, NESPACE Monitoring Control Unit KA RS232 for PC (GUI), TCP/IP, SNMP Forced air 2000 x 1200 x 700 per rack (master, slave) Operating -10 to +50 C, derating of 3 kw module above +45 0 C / Storage -40 to +80 C < 2000 M 90% non-condensing 60950-1 (pending) UL, CE Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Nespace Series Power Shelf 165kW 3438A 48V English 20170523

MODULAR INVERTER TM 250S Modular Inverter 1.0-1.6 kva 120 Vac 48 Vdc TM250S Modular Inverter series is a high frequency design with compact size and high power density. Ideally suited for 48V telecom and other applications where operation in high temperatures and N+1 redundancy is required. FEATURES High efficiency and high power density Efficiency up to 87% High power density 3U module High operating temperature range Operating range -20 to +40 C High reliability N+1 redundant Hot swappable Parallel operation DC-AC isolation Dynamic respons time to <20 ms Systems with 1.0, 1.5, 1.6 kva modules STM (max 6.4 kva) with TJ20 Monitor and Bypass Switch XTM (max 12.8 kva) with TJ21 Monitor Module HTM (max 12.8 kva 1 Phase) with TJ10 Monitor and STS HTM (max 38.4 kva 3 Phase) with TJ30 Monitor and STS keatecenergy.com

MODULAR INVERTER TM 250S Modular Inverter 1.0-1.6 kva 120 Vac 48 Vdc SPECIFICATIONS AC Output Nominal 120 Vac +2% Range 110, 115, 120 Vac adjustable Frequency 50-60 Hz +0.1 Hz Power 1.0 kva (TM 251S) 1.5 kva (TM 252S) 1.6 kva (TM 252S - 1600VA) Power factor 0.8 Efficiency up to 87% THD < 3% linear load, < 5% non-linear load Crest factor 3:1 Dynamic <20 ms response Overload capacity 125%, 10 min 150%, 1 min Connectors Terminal block DC Input Nominal 48 Vdc (-18% to +25%) General Specifications Display LED On/off Cooling Operating temp Full load Islolation Standards Safety EMC Fault, load% Front switch Forced air -20 to +40 C (-4 to +104 F) 1500 V rms EN60950-1 EN55022 Systems with 1.0, 1.5, 1.6 kva modules STM Max 6.4 kva with TJ20 Monitor and Bypass Switch XTM Max 12.8 kva with TJ21 Monitor Module HTM Max 12.8 kva 1 Phase with TJ10 Monitor and STS HTM Max 38.4 kva 3 Phase with TJ30 Monitor and STS Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS TM 250S Modular Inverter 1.0-1.6 kva 120 Vac 48 Vdc English 20161215

MODULAR INVERTER TM 250S Modular Inverter 1.0-2.0 kva 230 Vac 48 Vdc TM250S Modular Inverter series is a high frequency design with compact size and high power density. Ideally suited for 48V telecom and other applications where operation in high temperatures and N+1 redundancy is required. FEATURES High efficiency and high power density Efficiency up to 88% High power density 3U module High operating temperature range Operating range -20 to +40 C High reliability N+1 redundant Hot swappable Parallel operation DC-AC isolation Dynamic respons time to <20 ms Systems with 1.0, 1.5, 2.0 kva modules STM (max 6.0 kva) with TJ20 Monitor and Bypass Switch XTM (max 16 kva) with TJ21 Monitor Module HTM (max 16 kva 1 Phase) with TJ10 Monitor and STS HTM (max 48 kva 3 Phase) with TJ30 Monitor and STS keatecenergy.com

MODULAR INVERTER TM 250S Modular Inverter 1.0-2.0 kva 230 Vac 48 Vdc SPECIFICATIONS AC Output Nominal 230 Vac +2% Range 220, 230, 240 Vac adjustable Frequency 50-60 Hz +0.1 Hz Power 1.0 kva (TM 251S) 1.5 kva (TM 252S) 2.0 kva (TM 253S) Power factor 0.8 Efficiency up to 88% THD < 3% linear load, < 5% non-linear load Crest factor 3:1 Dynamic 20 ms response Overload capacity 125%, 10 min 150%, 1 min Connectors Terminal block DC Input Nominal 48 Vdc (-18 to +25%) General Specifications Display LED On/off Cooling Operating temp Full load Islolation Standards Safety EMC Fault, load% Front switch Forced air -20 to +40 C (-4 to +104 F) 1500 V rms EN60950-1 EN55022 Systems with 1.0, 1.5, 2.0 kva modules STM Max 6.0 kva with TJ20 Monitor and Bypass Switch XTM Max 16 kva with TJ21 Monitor Module HTM Max 16 kva 1 Phase with TJ10 Monitor and STS HTM Max 48 kva 3 Phase with TJ30 Monitor and STS Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS TM 250S Modular Inverter 1-2kVA 230 Vac 48 Vdc English 20161215

DIGITAL INVERTERS TP 600M Series Standalone Inverter 500 VA - 1 kva 120 Vac 24 Vdc TP 600M Series inverter is a high frequency design with compact size and high power density. Ideally suited for 24V telecom and other applications where high operating temperatures are required. FEATURES High efficiency and high power density Efficiency up to 87% High power density in 1U, 2U, 19 size High operating temperature range Operating range -20 to +60 C, full power up to +40 C High reliability DC-AC isolation Transfer time to 5-8 ms Flexible Standby design with an integrated utility bypass Selectable AC or DC working mode priority RS232 or RS485 communication port, four dry contacts Certification CE Options Models with LCD keatecenergy.com

DIGITAL INVERTERS TP 600M Series Standalone Inverter 500 VA - 1 kva 120 Vac 24 Vdc SPECIFICATIONS AC Output Nominal 100, 110, 120, 127 Vac +2% Frequency 50-60 Hz +0.1 Hz Nominal (model) 500 VA (605M) 1000 VA (610M) Power factor 0.8 Efficiency up to 87% THD < 3% linear load, < 5% non-linear load Crest factor 3:1 Transfer time 5-8 ms Dynamic response < 30 ms Overload capacity 125%, 10 sec 110%, 10 min AC Input Nominal 100/110/120/127 Vac +2% Range -25% + 20% Vac Frequency 50-60 Hz +10% General Specifications Display LED Mode, fault, battery capacity, load% Alarms Dry contacts (4) Communication RS232 or RS485 (optional) Cooling Forced air Enclosure IP20 Operating temp -20 to +60 C, full power up to +40 C Humidity <95% Islolation 1500 V rms Dimensions H x W x L mm Weight 44 x 436 x 319 (605M) (19, 1U) 88 x 436 x 256 (610M) (19, 2U) 6 kg (605M) 6 kg (610M) Standards Electrical safety EN 60950-1 EMC EN 55022 DC Input Nominal 24 Vdc (-17 to +25%) Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS TP 610M Series Standalone Inverter 500VA-1kVA 120Vac 24Vdc English 20161018

DIGITAL INVERTERS TP 600M Series Standalone Inverter 500 VA - 1 kva 230 Vac 24 Vdc TP 600M Series inverter is a high frequency design with compact size and high power density. Ideally suited for 24V telecom and other applications where high operating temperatures are required. FEATURES High efficiency and high power density Efficiency up to 88% High power density in 1U, 2U, 19 size High operating temperature range Operating range -20 to +60 C, full power up to +40 C High reliability DC-AC isolation Transfer time to 5-8 ms Flexible Standby design with an integrated utility bypass Selectable AC or DC working mode priority RS232 or RS485 communication port, four dry contacts Certification CE Options Models with LCD keatecenergy.com

DIGITAL INVERTERS TP 600M Series Standalone Inverter 500 VA - 1 kva 230 Vac 24 Vdc SPECIFICATIONS AC Output Nominal 208, 220, 230, 240 Vac +2% Frequency 50-60 Hz +0.1 Hz Nominal (model) 500 VA (605M) PF 0.8 1000 VA (610M) PF 0.8 Efficiency up to 88% THD < 3% linear load, < 5% non-linear load Crest factor 3:1 Transfer time 5-8 ms Dynamic response < 30 ms Overload capacity 125%, 10 sec 110%, 10 min AC Input Nominal 208/220/230/240 Vac Range -25% +20% Vac Frequency 50-60 Hz +10% General Specifications Display LED Mode, fault, battery capacity, load% Alarms Dry contacts (4) Communication RS232 or RS485 (optional) Cooling Forced air Enclosure IP20 Operating temp -20 to +60 C, full power up to +40 C Humidity <95% Islolation 1500 V rms Dimensions H x W x L mm Weight Standards Electrical safety IEC 60950-1 EMC EN 55022 44 x 436 x 319 (605M) (19, 1U) 88 x 436 x 256 (610M) (19, 2U) 6 kg (605M) 6 kg (610M) DC Input Nominal 24 Vdc (-17 to +25%) Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS TP 610M Series Standalone Inverter 500VA-1kVA 230Vax 24Vdc English 20161206

DIGITAL INVERTERS TP 600S Series Standalone Inverter 500 VA - 3 kva 120 Vac 48 Vdc TP 600S series inverter is a high frequency design with compact size and high power density. Ideally suited for 48V telecom and other applications where high operating temperatures are required. FEATURES High efficiency and high power density Efficiency up to 87% High power density in 1U, 2U, 19 size High operating temperature range Operating range -20 to +60 C, full power up to +40 C High reliability DC-AC isolation Transfer time to 5-8 ms Flexible Standby design with an integrated utility bypass Selectable AC or DC working mode priority RS232 or RS485 communication port, four dry contacts Certification CE Options Models with LCD keatecenergy.com

DIGITAL INVERTERS TP 600S Series Standalone Inverter 500 VA - 3 kva 120 Vac 48 Vdc SPECIFICATIONS AC Output Nominal 100, 110, 120, 127 Vac +2% Frequency 50-60 Hz +0.1 Hz Nominal (model) 500 VA (605S) 1000 VA (610S) 2000 VA (620S) 3000 VA (630S) Power factor 0.8 Efficiency up to 87% THD < 3% linear load, < 5% non-linear load Crest factor 3:1 Transfer time 5-8 ms Dynamic response < 30 ms Overload capacity 125%, 10 sec 110%, 10 min AC Input Nominal 100/110/120/127 Vac +2% Range -25% + 20% Vac Frequency 50-60 Hz +10% General Specifications Display LED Mode, fault, battery capacity, load% Alarms Dry contacts (4) Communication RS232 or RS485 (optional) Cooling Forced air Enclosure IP20 Operating temp -20 to +60 C, full power up to +40 C Humidity <95% Islolation 1500 V rms Dimensions H x W x L mm Weight 44 x 436 x 319 (605S, 610S) (19, 1U) 88 x 436 x 256 (620S) (19, 2U) 88 x 436 x 321 (630S) (19, 2U) 6 kg (605S) 6 kg (610S) 6 kg (620S) 12 kg (630S) Standards Electrical safety EN 60950-1 EMC EN 55022 DC Input Nominal 48 Vdc (-17 to +25%) LVD 40 Vdc Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS TP 610S Series Standalone Inverter 500VA-3kVA 120Vac 48Vdc English 20161018

DIGITAL INVERTERS TP 600S Series Standalone Inverter 500 VA - 5 kva 230 Vac 48 Vdc TP 600S Series inverter is a high frequency design with compact size and high power density. Ideally suited for 48V telecom and other applications where high operating temperatures are required. FEATURES High efficiency and high power density Efficiency up to 88% High power density in 1U, 2U, 19 size High operating temperature range Operating range -20 to +60 C, full power up to +40 C High reliability DC-AC isolation Transfer time to 5-8 ms Flexible Standby design with an integrated utility bypass Selectable AC or DC working mode priority RS232 or RS485 communication port, four dry contacts Certification CE Options Models with LCD keatecenergy.com

DIGITAL INVERTERS TP 600S Series Standalone Inverter 500 VA - 5 kva 230 Vac 48 Vdc SPECIFICATIONS AC Output Nominal 208, 220, 230, 240 Vac +2% Frequency 50-60 Hz +0.1 Hz Nominal (model) 500 VA (605S) PF 0.8 1000 VA (610S) PF 0.8 2000 VA (620S) PF 0.8 3000 VA (630S) PF 0.8 4000 VA (640S) PF 0.7 5000 VA (650S) PF 0.7 Efficiency up to 88% THD < 3% linear load, < 5% non-linear load Crest factor 3:1 Transfer time 5-8 ms Dynamic response < 30 ms Overload capacity 125%, 10 sec 110%, 10 min AC Input Nominal 208/220/230/240 Vac Range -25% +20% Vac Frequency 50-60 Hz +10% DC Input Nominal 48 Vdc (-17 to +25%) LVD 40 Vdc General Specifications Display LED Mode, fault, battery capacity, load% Alarms Dry contacts (4) Communication RS232 or RS485 (optional) Cooling Forced air Enclosure IP20 Operating temp -20 to +60 C, full power up to +40 C Humidity <95% Islolation 1500 V rms Dimensions H x W x L mm Weight Standards Electrical safety IEC 60950-1 EMC EN 55022 44 x 436 x 319 (605S, 610S) (19, 1U) 88 x 436 x 256 (620S) (19, 2U) 88 x 436 x 321 (630S, 640S) (19, 2U) 88 x 436 x 390 (650S) (19, 2U) 6 kg (605S) 6 kg (610S) 6 kg (620S) 12 kg (630S) 15 kg (640S) 15 kg (650S) Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS TP 610S Series Standalone Inverter 500VA-5kVA 230Vac 48Vdc English 20161206

SMALL CELL POWER SYSTEM Small Cell Power Series Outdoor Rectifier KLTE-413 13 A 54 Vdc 220 Vac Outdoor Rectifier for 4G and LTE mobile networks. FEATURES High efficiency Efficiency up to 90% Wide input voltage range 176-264Vac 1ph High operating temperature range Operating -30 to +50 C Reliable convection cooling Standards UL, CE, NEBS Level 3 Optional - Outdoor Battery Cabinet IP55 enclosure Wall mount Pull out battery racks Battery breaker 20A Lock and key security keatecenergy.com

SPECIFICATIONS AC Input Nominal 220 Vac 1ph Range 176-264 Vac Frequency 47~63 Hz Inrush 20 A at nominal input (max cold start) Current 4 A at nominal input (max continuous) Leakage 3.5 ma at 264 Vac Efficiency Up to 90% Input protection Double pole 10 A fuse / 250 Vac Undervoltage Overvoltage DC Output Nominal voltage Adjustment range Output current Line regulation 53.3 Vdc 40.0-58.0 Vdc 13 A max + 0.5% Max over entire input range Load regulation + 0.5% Max Temperature + 0.5% Max regulation Ripple and noise <250 mv, p-p, (10 Hz - 14 MHz) Over current 105-130% Output projection Overvoltage < 59 Vdc (recycle input to reset) thermal shutdown battery temperature compensation SMALL CELL POWER SYSTEM Small Cell Power Series Outdoor Rectifier KLTE-413 13 A 54 Vdc 220 Vac General Specifications MTBF 150,000 hours Operating temp -30 to +50 C Storage temp -40 to +85 C Humidity 10-90% non-condensing Cooling Convection cooling Environment NEBS Level 3 Altitude 3,000 m H x W x L 150 x 280 x 110 mm Weight 5 kg Communication High signal indicates DC is within regulation Interface RS485, TCP/IP Standards Electrical safety IEC 60950-1, UL 60950-1 EMC EN 55022 Class A (conducted) IEC 61000-4-2 (electrostatic discharge) IEC 61000-4-3 (radiated immunity) IEC 61000-4-4 (fast transients) IEC 61000-4-5 (surge immunity) IEC 61000-4-6 (conducted immunity) IEC 61000-4-10 (voltage dips) IEC 61000-4-11 (voltage interruptions) IEC 61000-3-3 (fluctuations & flicker) Harmonics EN 61000-3-2 Class D Certification UL, CE LVD CB Optional - Battery Cabinet Environment IP55 Shelf Pull out shelf (2) Configuraton 4 x 12V 12Ah batteries Battery breaker 20A Security Lock and key H x W x L 370 x 260 x 220 mm Weight 25 kg with batteries Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Small Cell Power Series Outdoor Rectifier KTLE 413 13A 54Vdc 220Vac English 20161228

SMALL CELL POWER SYSTEM Small Cell Power Series Outdoor Power Cabinet DORS 430K 30 A 54 Vdc 220 Vac Small Cell Power Series Outdoor Power Cabinet for 4G and LTE mobile networks. Wall mounted IP 55 cabinet with battery shelf and outdoor rectifier. FEATURES High efficiency Efficiency up to 90% Wide input voltage range 176-264 Vac 1Ph High operating temperature range Operating -30 to +50 C Reliable convection cooling Compact Outdoor Cabinet Wall mount IP 55 enclosure Shelf space for 4 x 18 Ah batteries AC utility outlet keatecenergy.com

SPECIFICATIONS SMALL CELL POWER SYSTEM Small Cell Power Series Outdoor Power Cabinet DORS 430K 30 A 54 Vdc 220 Vac AC Input Nominal 220 Vac 1 ph Range 176-264 Vac Frequency 57~63 Hz Inrush 50 A at nominal input (max cold start) Leakage 3.0 ma at 220 Vac Efficiency Up to 90% Input protection Double pole 15 A fuse / 250 Vac Undervoltage Overvoltage DC Output Nominal voltage 53.3 Vdc Adjustment range 42.0-58.0 Vdc Output current 30 A max Line regulation + 1.0% Max over entire input range Load regulation + 1.0% Max Temperature + 1.0% Max regulation Ripple and noise <250 mv, p-p, (10 Hz - 14 MHz) Over current 105-130% Output projection Overvoltage < 57.5 Vdc (recycle input to reset) thermal shutdown battery temperature compensation Battery Configuration General Specifications MTBF Operating temp Storage temp Humidity Cooling Altitude Enclosure H x W x L Interface 4 x 12V 18 AH (not included) 100,000 hours -30 to +50 C -40 to +75 C 10-90% non-condensing Convection cooling 2,000 m 645 x 400 x 245 mm GUI, input dry contact, alarm Standards Electrical safety IEC 60950-1, UL 60950-1 EMC EN 55022 Class A (conducted) IEC 61000-4-2 (electrostatic discharge) IEC 61000-4-3 (radiated immunity) IEC 61000-4-4 (fast transients) IEC 61000-4-5 (surge immunity) IEC 61000-4-6 (conducted immunity) IEC 61000-4-10 (voltage dips) IEC 61000-4-11 (voltage interruptions) Harmonics EN 61000-3-2 Class D Enclosure IP 55 Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Small Cell Power Series Outdoor Power Cabinet DORS430K 30A 54Vdc 220Vac English 20161209

SMALL CELL POWER SYSTEM Small Cell Power Series Outdoor Power Cabinet KLTE-430D 30 A 54 Vdc 220 Vac Small Cell Power Series Outdoor Power Cabinet for 4G and LTE mobile networks. Wall or Pole mounted IP 65 cabinet with outdoor rectifier. External battery optional. FEATURES High efficiency Efficiency up to 90% Wide input voltage range 176-264 Vac 1ph High operating temperature range Operating -30 to +50 C Reliable convection cooling Compact Outdoor Cabinet Wall or poll mount IP65 AC utility outlet Monitoring Full feature status and alarms Dry contact alarm LED alarm indicators Worldwide certifications UL, CE and NEBS Level 3 keatecenergy.com

SPECIFICATIONS SMALL CELL POWER SYSTEM Small Cell Power Series Outdoor Power Cabinet KLTE-430D 30 A 54 Vdc 220 Vac AC Input Nominal 220 Vac 1 ph Range 176-264 Vac Frequency 47~63 Hz Inrush 20 A at nominal input (max cold start) Current 10 A at nominal input (max continuous) Leakage 3.5 ma at 264 Vac Efficiency Up to 90% Input protection Double pole 15 A fuse / 250 Vac Undervoltage Overvoltage DC Output Nominal voltage Adjustment range Output current Line regulation 53.3 Vdc 40.0-58.0 Vdc 30 A max + 0.5% Max over entire input range Load regulation + 0.5% Max Temperature + 0.5% Max regulation Ripple and noise <250 mv, p-p, (10 Hz - 14 MHz) Over current 105-130% Output projection Overvoltage < 59 Vdc (recycle input to reset) Thermal shutdown Battery temperature compensation Battery Configuration General Specifications MTBF Operating temp Storage temp Humidity Cooling Altitude Rectifier H x W x L Communication Interface External (not included) 150,000 hours -30 to +50 C -40 to +85 C 10-90% non-condensing Convection cooling 3,000 m 362 x 250 x 232 mm High signal indicates DC is within regulation RS485, TCP/IP, Dry Contact Alarm Standards Electrical safety IEC 60950-1, UL 60950-1 EMC EN 55022 Class A (conducted) IEC 61000-4-2 (electrostatic discharge) IEC 61000-4-3 (radiated immunity) IEC 61000-4-4 (fast transients) IEC 61000-4-5 (surge immunity) IEC 61000-4-6 (conducted immunity) IEC 61000-4-10 (voltage dips) IEC 61000-4-11 (voltage interruptions) IEC 61000-3-3 (fluctuations & flicker) Harmonics EN 61000-3-2 Class D Environment NEBS Level 3 Certification UL, CE LVD, CB Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Small Cell Power Series Outdoor Power Cabinet KTLE 430D 30A 54Vdc 220Vac English 20161209

VRLA AND AGM BATTERY GENERAL FEATURES Valve Regulated - Sealed Construction Valve regulated lead acid and AGM batteries are rechargeable and designed for safe, trouble free operation in any position. Ease of Shipment Can be shipped by sea, road or air without special handling and packaging precautions due to their sealed construction. Maintenance Free Operation No need to check the specific gravity of the electrolyte. No requirement to refill electrolyte or add water during normal operation. Cycle or Float Service Suitable for either cycling or floating service Heavy Duty Grids Heavy duty calcium-tin alloy grids extend service life. Compact Design A high power-to-weight ratio battery. Low Self Discharge Lead calcium grids minimize capacity loss during long periods of storage time at room temperature. Wide Operating Temperature Performance over a broad range of ambient temperatures. Impact Resistant Case Impact resistant and non-conductive plastic case. CONSTRUCTION

PRINCIPLE OPERATION OF VALVE REGULATED LEAD ACID BATTERY Positive Plate. Negative Plate. Net. PbO2+SO4-+4H + +2e-=PbSO4+H2O - Pb+SO4 +4H + +2e-=PbSO4+H2O - PbO2+2SO4 + 4H + + Pb =2PbSO4+2H2O The gassing and water loss reactions are as follows: Positive Plate. Negative Plate. Net. H2O=2H + +1/2O2+2e - 2H + +2e - = H2 H2O=H2+1/2O2 Note that the gassing reaction generally occurs when the battery is almost totally charged. In the valve regulated battery water loss must be avoided by limiting the escape of hydrogen and oxygen from the battery. Therefore the battery design supports the recombination of the oxygen formed at the positive plate with the hydrogen formed at the negative plate as follows. Negative a. Negative b. Net Negative. Pb+1/2O2+H2SO4=PbSO4 +H2O PbSO4+2H + +2e - =Pb +H2SO4 1/2O2+2H + +2e - =H2O The virtually eliminates the production of free hydrogen at the negative plate during recombination. However it is necessary to ensure that correct charging voltages are used because the construction provides a means of recombining the internally generated hydrogen and oxygen, and suppresses the evolution of hydrogen gas to limit the consumption of water from the electrolyte. Therefore the battery requires no addition of water during its normal life time. Valve regulated batteries are sealed with the exception of a valve that opens when excess pressure builds up inside the battery. The valve automatically reseals itself. The recombination of charge gases is accomplished by allowing oxygen produced at the positive plate to pass through the separator material to the negative plates where the recombination reaction occurs. The valve controls the internal process of the battery to optimize the efficiency of the recombination reaction and minimize the possible expense of electrolyte. NOMINAL CAPACITY The capacity of a battery is the available amount of electrical energy which can be obtained from a fully charged cell. The capacity of a cell is expressed in ampere hours (AH), which is a current-time product. The capacity value is dependent upon the discharge current, the temperature during discharge, the final cutoff voltage and the general history. The nominal capacity of a battery is measured at the 10 hour or 20 hour rate at 25 to a cut-off voltage of 1.75 volts per cell. STORAGE During storage, batteries gradually lose their capacity due to their self-discharge. The self-discharge rate is low and is typically less than 3% per month at 25. Although the self-discharge rate is low, specific precautions must be taken against the battery over self-discharging itself when in storage or not in use. Precautions Against Over Self-discharge a. The batteries should be stored in a clean, cool and dry place b. Storage place should not be affected by sources of radiant heat such as sun, heating units, radiators or steam pipes c. The recommendable storage temperature: 10~20 d. The recommendable storage humidity is as low as possible Charge AdviceStorage Temperature Charging Interval 20 or less 9 months 20~30 6 months 30~40 3 months

Temperature above 40 should be avoided. After long term storage, all batteries deliver less than the rated capacity. Full capacity will be obtained after several charge/discharge cycles. For the longest life a battery should be fully charged before being put into storage. Self-Discharge Characteristics Open Circuit Voltage and Remaining Capacity 2.33 0 (32 Capacity Retentionratio (%) 40 (104 30 (86 20 (68 5 (41 10 (50 Battery Volts ( ) 2.17 2.0 1.83 1.67 Storage Time (Months) Capacity (25 ) BATTERY DISCHARGING The capacity of a battery is the available amount of electrical energy which can be obtained from a fully charged cell. The capacity of a battery is expressed in amperehours(ah),which is a current-time product. The capacity value is dependent upon the discharge current, the temperature during discharge, the final cut-off voltage and the general history. The nominal capacity of an battery is measured at the 10 hour or 20 hour rate according to types at 25 to a cut-off voltage of 1.80 volts or 1.75 volts per cell. Battery Selection The battery discharge curve may be utilised in battery selection. However it is suggested that a review is made of the data sheet for each battery size or the chart showing the actual ampere hour capacity of each battery size at various discharge times. Temperature Effect on discharge Capacity The discharge capacity varies according to the temperature during discharge. At low temperature the discharge capacity decreases and at high temperature it increases. the temperature effects on the discharge capacity at various discharge current rates are shown in the graph. Final Acceptable Discharge Voltages The battery cut-off voltage is the volts per cell to which a battery may be discharged safely to maximise battery life, this value is specified according to the actual discharge load and run time. As a rule of thumb, high amp loads and short run times will tolerate a lower cut off voltage, whereas a low amp long run time discharge will require a higher cut off voltage. Terminalv oltage (V) Capacity (%) Discharge Characteristic Curve 3C 2C Discharge current 1C 0.6C Discharge time Cut off Volts/Cell 3CA 1.30 1CA 1.30 0.5-1.0 CA 1.55 0.2-0.5 CA 1.70 0.05-0.2CA CA 1.75 0.17C 0.05C 0.27C 0.10C Rating the Capacity at 25 Temperature 2.17 2.0 1.83 1.67 1.5 1.33

CHARGING CHARACTERISTICS The characteristics of charging by constant voltage (recommended) are shown in the graph. Standby Use Cycle Use Charge Method Cyclic Operation Float Operation Refresh Charge During Storage 2.40~2.45vpc 2.25~2.30vpc 2.40~2.45vpc Constant Voltage Initial current Initial current Initial current 0.3CA or less 0.3CA or less 0.3CA or less Constant Current Charging current approximately 0.1 CA. Charge time control is also recommended otherwise an overcharge can occur. Not applicable Charging current: approximately 0.1CA Charging Method Ambient Temperature: 25 Note: ensurethe voltage is set correctly. A voltage set too high will increase the corrosion of the positive plates and shorten battery life. A voltage set too low will lead to sulphation of the plates causing loss of capacity and ultimately shortening the life of the battery. BATTERY LIFE Cyclic Use Cycle life is very dependent on the depth of discharge which the battery experiences during each cycle. The number of cycles relating to the depth of discharge is shown in the graph. Effect of Temperature on Charging Voltage Within the normal operating parameters of 20 ~30 voltage compensation for operating temperature may not be necessary. However, to maximise the life of the battery, temperature compensation for operating temperatures outside this temperature range should be considered. Charging voltage compensation for battery temperature: Capacity (%) 100% D.O.D 50% D.O.D 30% D.O.D 1.Float operation: Vt=V-0.003(t-25) 2.Cyclic operation: Vt=V-0.005(t-25) (V=Charging voltage at 25, t=temperature,vt=charging voltage at t ) Number of cycles

Floating Use Float use life is very dependent on the temperature at which the battery is float charged. The float life is very long at low temperature (10~20 )but at higher temperature the float life is shortened. Life (Years) Temperature TERMINAL DATA F1 F2 B1 B2 M M1 14 0.551 6 0.236 M2 16 0.630 6 0.236 M3 20 0.787 8 0.315 M4 12 0.47 5 0.20 M5 18 0.71 8 0.31 M6 18 0.71 6 0.236

6-FMH-100 FMH Series For Front Terminal 6-FMH-100 Specifications Nominal Voltage Rated Capacity (20 hour rate) Total Height (with terminals) Dimensions Height length width Weight Characteristics Capacity 77 (25 ) Internal Resistance Capacity affected by Temperature (20hour rate) Self-Discharge 77 (25 ) Max. Discharge Current 77 (25 ) Terminal Charge Cycle (Constant Voltage) Float 12V 100Ah 11.26 inches(286mm) 11.26 inches(286mm) 15.55 inches(395mm) 4.33 inches(110mm) Approx.71.06 Pound(32.3kg) 20 hour rate (5.0A) 100 Ah 10 hour rate (9.2A) 92 Ah 5 hour rate (16.0A) 80 Ah 1hour rate (60.0A) 60 Ah 15Minute Rate (164A) 41 Ah Full charged Battery 77 (25 ) 4.5 MΩ 104 (40 ) 102% 77 (25 ) 100% 32 (0 ) 85% 5 (-15 ) 65% Capacity after 3 month storage 91% Capacity after 6 month storage 81% Capacity after 12 month storage 60% 800A(5S) M6 Initial Charging Current less than 30A Voltage 14.4~14.7 V / 77 (25 ) Voltage 13.5~13.8V / 77 (25 ) Constant Current Discharge (AMPERES @25 Discharge Curves 77 (25 ) Discharge time Relationship between charge voltage and temperature F.V/Time 5Min 10Min 15Min 30Min 60Min 2H 3H 4H 5H 10H 20H 1.65 311 217 168 102 80.1 54.7 37.8 26.0 17.5 10.6 4.33 1.70 285 205 157 86.8 75.7 52.1 36.9 25.0 16.9 10.4 4.25 1.80 227 173 137 78.4 71.5 49.4 35.3 23.6 16.0 10.0 4.17 Terminalv oltage (V) 13.0 12.0 11.0 10.0 (V/6V) 9.0 8.0 7.8 7.5 7.2 6.9 6.6 (V/12V) (V/CELL) 15.6 15.0 14.4 13.8 13.2 3C 1C 0.59C 0.56C CYCLE USE STAND BY USE Ambient temperature ( ) 0.16C 0.09C 0.092C0.05C 0.05C -10 0 10 20 30 40 50 60 Constant Power Discharge (WATTS PER CELL@25 Cut off voltage V/cell 5min 10min 15min 30min 45min 1h 2h 3h 5h 10h 24h 1.60 571 394 307 191 148 119 70.0 49.1 32.4 18.3 8.11 1.65 542 389 304 185 146 115 69.1 49.0 32.2 18.2 8.10 1.67 540 386 302 173 144 114 68.8 48.6 31.9 18.2 8.09 1.70 506 379 291 162 142 111 68.4 47.7 31.6 18.1 8.07 1.75 461 346 274 156 141 108 67.9 46.4 31.0 18.0 8.06 1.80 423 330 264 151 138 107 66.6 46.1 30.5 17.7 8.04 1.85 339 273 231 141 127 104 64.2 45.0 29.5 16.9 7.62 www.keatecenergy.com

FMH Series For Front Terminal 6-FMH-100 Temperature above 40C should be avoided. After long term storage, the battery capacity will be less than the rated capacity. Full capacity will be achieved after several charge/discharge cycles. For the longest life, the battery should be fully charged before storage. Cycle service life in relation to depth of discharge Constant voltage charge characteristic Charged Volume Current Voltage (%) ( CA) (V) 140 (0.25CA,25 ) Capacity (%) 100% D.O.D D.O.D 50% D.O.D 30% D.O.D 120 100 80 60 40 0.25 0.20 0.15 0.10 15.0 14.0 13.0 12.0 CHARGED VOLUME CHARGE VOLTAGE 20 0.05 11.0 CHARGE CURRENT Number of cycles 0 0 0 2 4 6 8 10 12 14 16 18 20 Charge time(hours) Self-Discharge Characteristics Relationship of OCV and Residual Capacity % (25 ) 0 (32 Capacity (%) 5 (41 10 (50 Residual Capacity ( ) 40 (104 30 (86 20 (68 Storage Time (Months) Temperature effects on capacity Capacity (25 ) Temperature effects float life Capacity (%) CA: Rated Capacity at 25 Life (Years) 6-FMH-100 Temperature Temperature www.keatecenergy.com

6-FMH-150 FMH Series For Front Terminal 6-FMH-150 Specifications Nominal Voltage Rated Capacity (20 hour rate) Total Height (with terminals) Dimensions Height length width Weight Characteristics Capacity 77 (25 ) Internal Resistance Capacity affected by Temperature (20hour rate) Self-Discharge 77 (25 ) Max. Discharge Current 77 (25 ) Terminal Charge (Constant Voltage) Cycle Float 12V 150Ah 11.34 inches(288mm) 11.34 inches(288mm) 21.69 inches(551mm) 4.33 inches(110mm) Approx.101 Pound(45.9kg) 20 hour rate (7.5A) 150 Ah 10 hour rate (13.8A) 138 Ah 5 hour rate (24.0A) 120 Ah 1hour rate (90.0A) 90 Ah 15Minute Rate (246A) 61.5 Ah Full charged Battery 77 (25 ) 4.0 MΩ 104 (40 ) 102% 77 (25 ) 100% 32 (0 ) 85% 5 (-15 ) 65% Capacity after 3 month storage 91% Capacity after 6 month storage 81% Capacity after 12 month storage 60% 1000A(5S) M6 Initial Charging Current less than 45A Voltage 14.4~14.7 V / 77 (25 ) Voltage 13.5~13.8V / 77 (25 ) Constant Current Discharge (AMPERES @25 Discharge Curves 77 (25 ) Discharge time Relationship between charge voltage and temperature F.V/Time 5Min 10Min 15Min 30Min 60Min 2H 3H 4H 5H 10H 20H 1.65 461 322 249 157 119 82.2 56.8 38.2 26.3 16.2 6.73 1.70 426 303 239 148 112 80.2 55.0 37.5 25.8 15.7 6.51 1.80 336 255 203 122 106 78.1 53.0 35.9 24.7 15.0 6.25 Terminalv oltage (V) 13.0 12.0 11.0 10.0 (V/6V) 9.0 8.0 7.8 7.5 7.2 6.9 6.6 (V/12V) (V/CELL) 15.6 15.0 14.4 13.8 13.2 3C 1C 0.59C 0.56C CYCLE USE STAND BY USE Ambient temperature ( ) 0.16C 0.09C 0.092C0.05C 0.05C -10 0 10 20 30 40 50 60 Constant Power Discharge (WATTS PER CELL@25 Cut off voltage V/cell 5min 10min 15min 30min 45min 1h 2h 3h 5h 10h 24h 1.60 821 583 454 291 219 178 106 73.7 48.6 27.8 12.2 1.65 804 576 451 286 217 175 104 73.5 48.4 27.6 12.1 1.67 801 571 450 282 213 174 103 73.4 48.3 27.5 12.0 1.70 757 560 441 276 210 173 102 73.1 48.1 27.2 11.9 1.75 697 524 416 247 208 172 101 72.6 47.9 27.0 11.8 1.80 626 487 391 234 205 171 100 71.6 47.2 26.5 11.6 1.85 501 404 342 214 188 159 95.5 68.7 44.0 25.2 11.4 www.keatecenergy.com

FMH Series For Front Terminal 6-FMH-150 Temperature above 40C should be avoided. After long term storage, the battery capacity will be less than the rated capacity. Full capacity will be achieved after several charge/discharge cycles. For the longest life, the battery should be fully charged before storage. Cycle service life in relation to depth of discharge Constant voltage charge characteristic Charged Volume Current Voltage (%) ( CA) (V) 140 (0.25CA,25 ) Capacity (%) 100% D.O.D D.O.D 50% D.O.D 30% D.O.D 120 100 80 60 40 0.25 0.20 0.15 0.10 15.0 14.0 13.0 12.0 CHARGED VOLUME CHARGE VOLTAGE 20 0.05 11.0 CHARGE CURRENT Number of cycles 0 0 0 2 4 6 8 10 12 14 16 18 20 Charge time(hours) Self-Discharge Characteristics Relationship of OCV and Residual Capacity % (25 ) 0 (32 Capacity (%) 5 (41 10 (50 Residual Capacity ( ) 40 (104 30 (86 20 (68 Storage Time (Months) Temperature effects on capacity Capacity (25 ) Temperature effects float life Capacity (%) CA: Rated Capacity at 25 Life (Years) 6-FMH-150 Temperature Temperature www.keatecenergy.com

6-GFMH-180 FMH Series For Front Terminal 6-GFMH-180 Specifications Nominal Voltage Rated Capacity (10 hour rate) Total Height (with terminals) Dimensions Height length width Weight 12V 180Ah 12.4 inches(320mm) 12.4 inches(320mm) 21.5 inches(546mm) 4.92 inches(125mm) Approx.116.9 Pound(53kg) Discharge Curves 77 (25 ) Terminalv oltage (V) 13.0 12.0 11.0 10.0 9.0 8.0 3C 1C 0.59C 0.56C 0.16C 0.09C 0.092C0.05C 0.05C Characteristics Capacity 77 (25) Internal Resistance Capacity affected by Temperature (20hour rate) Self-Discharge 77 (25) Max. Discharge Current 77 (25) Terminal Charge Cycle (Constant Voltage) Float 20 hour rate (9.0A) 180Ah 10 hour rate (16.5A) 165Ah 5 hour rate (28.8A) 144Ah 1hour rate (101A) 101Ah 15Minute Rate (295A) 73.8Ah Full charged Battery 77 (25) 4mΩ 104 (40) 102% 77 (25) 100% 32 (0) 85% 5 (-15) 65% Capacity after 3 month storage 91% Capacity after 6 month storage 81% Capacity after 12 month storage 60% 1050A(5S) M8 Initial Charging Current less than 54A Voltage 14.4~14.7 V / 77 (25) Voltage 13.5~13.8V / 77 (25) Relationship between charge voltage and temperature (V/6V) 7.8 7.5 7.2 6.9 6.6 (V/12V) (V/CELL) 15.6 15.0 14.4 13.8 13.2 Discharge time CYCLE USE STAND BY USE -10 0 10 20 30 40 50 60 Ambient temperature () Constant Current Discharge (AMPERES @25 6-GFMH-180 1.65 1.70 1.80 391 369 311 302 283 247 184 156 141 144 136 129 101 93.5 88.9 Constant Power Discharge (WATTS PER CELL@25 68.0 66.4 63.5 47.0 45.0 42.5 31.5 30.4 28.8 22.3 21.4 20.2 17.6 17.3 16.6 15.1 14.7 14.3 7.80 7.66 7.52 1.60 1.65 1.67 1.70 1.75 1.80 1.85 700 691 685 672 629 584 485 545 541 540 529 499 469 410 349 343 338 331 296 281 257 263 260 256 252 250 246 226 214 210 209 208 206 205 191 127 125 124 122 121 120 115 88.4 88.2 88.1 87.7 87.1 85.9 82.4 58.3 58.1 58.0 57.7 57.5 56.6 52.8 40.2 40.1 40.0 39.7 39.0 38.5 35.9 33.4 33.1 33.0 32.6 32.4 31.8 30.2 28.4 28.3 28.2 28.0 27.7 27.5 25.7 14.6 14.5 14.4 14.3 14.2 13.9 13.7

FMH Series For Front Terminal 6-GFMH-180 Temperature above 40C should be avoided. After long term storage, the battery capacity will be less than the rated capacity. Full capacity will be achieved after several charge/discharge cycles. For the longest life, the battery should be fully charged before storage. Cycle service life in relation to depth of discharge Constant voltage charge characteristic Charged Volume Current Voltage (%) ( CA) (V) 140 (0.25CA,25 ) Capacity (%) 100% D.O.D D.O.D 50% D.O.D 30% D.O.D 120 100 80 60 40 0.25 0.20 0.15 0.10 15.0 14.0 13.0 12.0 CHARGED VOLUME CHARGE VOLTAGE 20 0.05 11.0 CHARGE CURRENT Number of cycles 0 0 0 2 4 6 8 10 12 14 16 18 20 Charge time(hours) Self-Discharge Characteristics Relationship of OCV and Residual Capacity % (25 ) 0 (32 ) Capacity (%) 5 (41 ) 10 (50 ) Residual Capacity ( ) 40 (104 ) 30 (86 ) 20 (68 ) Storage Time (Months) Temperature effects on capacity Capacity (25 ) Temperature effects float life Capacity (%) CA: Rated Capacity at 25 Life (Years) 2 1 3 4 6-GFMH-180 Temperature Temperature

BATTERY NiCd Battery Te hnolo FEATURES ominal. Ah ated at C5 ( 0 + - 5 C) M - esigned for Medium discharge rate of 0.5 t A.5 t A L - esigned for a discharge rate lower than 0.5 t A State-of-the-art automated manufacturing ensures consistency and reliability. icd batteries have a service life much longer than that of Lead Acid batteries, which suffer from lead plate shedding and internal corrosion. icd batteries are widely used for outdoor applications because they operate reliably at temperatures up to + 0 C. keatecenergy.com

BATTERY KGL Series NiCd Gas Recombination Battery Maintenance free KGL Series Ni- Cd rechargeable batteries use negative oxygen recombination technology and gas recombination vent plugs. State-of-the-art automated manufacturing ensures consistency and reliability. Designed for a discharge rate lower than 0.5 I t A FEATURES Ah Rated at C5 (20 +/- 5 o C) Nominal 1.2 V Long Life Ultra-low water consumption due to high gas recombination efficiency and vent plug technology Pocket plates and internal frames made of steel do not react with the electrolyte Service life can exceed 25 years with virtually no internal corrosion 2,000 cycles with at most a single replacement of electrolyte Operation at Extreme Temperatures -40 C to +60 C Top Quality Materials Plates - horizontal pockets of double perforated steel strips Separator is polypropylene fiber Nickel plated steel terminals Translucent plastic container Easy Handling Maintenance free Top access terminals Flip top vent caps keatecenergy.com

SPECIFICATIONS BATTERY KGL Series NiCd Gas Recombination Battery Model C5 Rated Capacity Ah Nominal Voltage Dimensions H x W xl mm Weight kg Terminals Threading Container Material KGL 30 30 1.2 245 x 134 x 68 2.7 2 x M10 PP KGL 40 40 1.2 245 x 134 x 68 2.9 2 x M10 PP KGL 50 50 1.2 285 x 134 x 68 3.8 M16 PP KGL 60 60 1.2 285 x 134 x 70 3.9 M16 PP KGL 70 70 1.2 285 x 134 x 70 4.1 M16 PP KGL 80 80 1.2 370 x 141 x 80 5.8 M10 PP KGL 90 90 1.2 370 x 141 x 80 5.9 M10 PP KGL 100 100 1.2 370 x 141 x 80 6.0 M10 PP KGL 150 150 1.2 348 x 165 x 107 8.7 M20 PP KGL 200 200 1.2 450 x 171 x 100 11.8 M20 PP KGL 250 250 1.2 450 x 171 x 100 12.5 M20 PP KGL 300 300 1.2 385 x 170 x 152 15.0 M20 PP KGL 350 350 1.2 385 x 170 x 152 15.9 M20 PP KGL 400 400 1.2 450 x 276 x 138 23.0 2 x M16 PP KGL 450 450 1.2 490 x 276 x 138 24.8 2 x M16 PP KGL 500 500 1.2 490 x 276 x 138 36.0 2 x M16 PP KGL 550 550 1.2 510 x 291 x 176 36.5 2 x M20 MBS KGL 600 600 1.2 510 x 291 x 176 39.0 2 x M20 MBS Compliance IEC 62259 Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS KGL Series NiCd Gas Recombination Battery English 20170515

BATTERY KGM Series NiCd Gas Recombination Battery Maintenance free KGM Series Ni- Cd rechargeable batteries use negative oxygen recombination technology and gas recombination vent plugs. State-of-the-art automated manufacturing ensures consistency and reliability. Designed for a medium discharge rate of 0.5 I t A ~ 3.5 I t A FEATURES Ah Rated at C5 (20 +/- 5 o C) Nominal 1.2 V Long Life Ultra-low water consumption due to high gas recombination efficiency and vent plug technology Pocket plates and internal frames made of steel do not react with the electrolyte Service life can exceed 25 years with virtually no internal corrosion 2,000 cycles with at most a single replacement of electrolyte Operation at Extreme Temperatures -40 C to +60 C Top Quality Materials Plates - horizontal pockets of double perforated steel strips Separator is polypropylene fiber Nickel plated steel terminals Translucent plastic container Easy Handling Maintenance free Top access terminals Flip top vent caps keatecenergy.com

SPECIFICATIONS BATTERY KGM Series NiCd Gas Recombination Battery Model C5 Rated Capacity Ah Nominal Voltage Dimensions H x W xl mm Weight kg Terminals Threading Container Material KGM 30 30 1.2 285 x 134 x 70 3.6 M16 PP KGM 40 40 1.2 285 x 134 x 70 3.8 M16 PP KGM 50 50 1.2 285 x 134 x 70 4.1 M16 PP KGM 60 60 1.2 370 x 141 x 80 5.8 M16 PP KGM 70 70 1.2 370 x 141 x 80 6.0 M16 PP KGM 80 80 1.2 370 x 141 x 80 6.5 M16 PP KGM 90 90 1.2 348 x 165 x 107 8.7 M20 PP KGM 100 100 1.2 348 x 165 x 107 8.3 M20 PP KGM 150 150 1.2 348 x 167 x 107 12.4 M20 PP KGM 200 200 1.2 348 x 167 x 164 14.2 M20 PP KGM 250 250 1.2 385 x 170 x 152 15.7 M20 PP KGM 300 300 1.2 450 x 200 x 162 22.5 2 x M16 PP KGM 350 350 1.2 450 x 200 x162 23.0 2 x M16 PP KGM 400 400 1.2 490 x 278 x 138 35.7 2 x M16 PP KGM 450 450 1.2 510 x 291 x 176 36.2 2 x M20 MBS KGM 500 500 1.2 510 x 291 x 176 37.0 2 x M20 MBS KGM 550 550 1.2 510 x 291 x 176 37.5 2 x M20 MBS KGM 600 600 1.2 510 x 291 x 176 38.0 2 x M20 MBS Compliance IEC 62259 Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS KGM Series NiCd Gas Recombination Battery English 20170515

BATTERY h on Battery Te hnolo FEATURES Maintenance free rack mounted Lion rechargeable batteries are ideal for Telecom applications. Lithium-ion (Lion) batteries deliver high power density, deep cycling capability and a service life much longer than that of Lead Acid batteries. Lion batteries also accept high charge currents and recharge very quickly. Unlike Lead Acid Batteries, Lion Battery packs precisely control the charging process through an on-board Battery Management System (BMS) that communicates with the charging device. Lion batteries are maintenance free and ultimately deliver the lowest total cost of ownership. Lion can be used for outdoor applications because they discharge reliably at temperatures up to +55 C and can be recharged at temperatures up to +40 C. State-of-the-art automated manufacturing ensures consistency and reliability. keatecenergy.com

BATTERY LBT Series LiFePo Battery 48 Vdc 50 Ah LBT Series maintenance free rack mounted Lithium-ion rechargeable batteries are ideal for Telecom applications. State-of-the-art automated manufacturing ensures consistency and reliability. Lifetime of up to 15 years, or 6,000 cycles 80% SoC. FEATURES Battery Management System (BMS) State of charge and health management PC management and monitoring software RS232 and RS485 communications Alarms Data storage Operation at Extreme Temperatures Charging 0 C to +50 C Discharging 0 C to +60 C Easy Handling Rack mount - 19 inch Height - 3U Parallel up to 15 batteries Options LCD display screen keatecenergy.com

SPECIFICATIONS BATTERY LBT Series LiFePo Battery 48 Vdc 50 Ah LBT 4850 Nominal voltage 51.2 Vdc Nominal capacity 50 Ah / 2.56 kwh (0.2 C, to 43.2 V, at 25 C) Charging cut-off voltage 58.4 Vdc Discharging cut-off voltage 40 Vdc Standard charging current 10 A Max charging 50 A Standard discharging current 10 A Max discharging current 50 A BMS power consumption < 1.5 W H x W x D mm 132.5 x 480 x 383.2 Weight kg 27 Discharging temperature 0 to +60 C Charging temperature 0 to +50 C Storage temperature 15 to 25 C Humidity < 80 % Environment IP 30 Protection Over-current, over-voltage, under-voltage, over-temperature, short-cicuit Parallel up to 15 Communications RS232, RS485 Monitoring PC Software (RS 485 or Modbus) Standards IEC 62619, IEC 21A/556CD, RoHS, UN/DOT 38.3, EN 61000-6-1, EN 61000-6-3, EN 55032, EN55024 Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Keatec LBT Series LiFePo Battery 48V 50A English 20180112

BATTERY LBT Series LiFePo Battery 48 Vdc 100 Ah LBT Series maintenance free rack mounted Lithium-ion rechargeable batteries are ideal for Telecom applications. State-of-the-art automated manufacturing ensures consistency and reliability. Lifetime of up to 15 years, or 6,000 cycles 80% SoC. FEATURES Battery Management System (BMS) State of charge and health management PC management and monitoring software RS232 and RS485 communication Data storage Alarms Operation at Extreme Temperatures Charging 0 C to +50 C Discharging 0 C to +60 C Easy Handling Rack mount - 19 inch Height - 5U Parallel up to 15 batteries Options LCD display keatecenergy.com

SPECIFICATIONS BATTERY LBT Series LiFePo Battery 48 Vdc 100 Ah LBT 48100 Nominal voltage 51.2 Vdc Nominal capacity 100 Ah / 5.12 kwh (0.2 C, to 43.2 V, at 25 C) Charging cut-off voltage 58.4 Vdc Discharging cut-off voltage 40 Vdc Standard charging current 20 A Max charging 50 A Standard discharging current 20 A Max discharging current 50 A BMS power consumption < 1.5 W H x W x D mm 221.5 x 480 x 385 Weight kg 48 Discharging temperature 0 to +60 C Charging temperature 0 to +50 C Storage temperature 15 to 25 C Humidity < 80 % Environment IP 30 Protection Over-current, over-voltage, under-voltage, over-temperature, short-cicuit Parallel up to 15 Communications RS232, RS485 Monitoring PC Software (RS 485 or Modbus) Standards IEC 62619, IEC 21A/556CD, RoHS, UN/DOT 38.3, EN 61000-6-1, EN 61000-6-3, EN 55032, EN55024 Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Keatec LBT Series LiFePo Battery 48V 100A English 20180112

PROFESSIONAL SERVICES Preventative Maintenance - Batteries UPS runtime can be greatly reduced by a single degraded battery that adversely affects the performance of the entire string PROFESSIONAL SERVICES Battery state-of-health testing Discharge testing Temperature checks Inspection for leaks and corrosion Clean and tighten connections - UPS availability and performance improves when its supported by healthy batteries - Costly emergency repairs and lost business revenue are avoided when batteries are proactively replaced before a failure - Best practices are followed with the removal and recycling of spent batteries keatecenergy.com

PROFESSIONAL SERVICES Preventative Maintenance - Batteries Cycle life is very dependent on the depth of discharge which the battery experiences during each cycle. Float use life is very dependent on the temperature at which the battery is float charged. Float use life is longer at low temperatures (10~20 0 C) but at higher temperatures float use life is shortened. FACTORS AFFECTING BATTERY LIFE AND PERFORMANCE x - Charging at high or low voltage x - Low or excessive charge current x - High room temperatures x - Overcharging or undercharging x - Loose interconnections between batteries in the string x - Improper maintenance - Lead acid batteries lose capacity (runtime) based on age, usage and operating temperature. - Every time a battery is discharge, it shortens the remaining lifetime. - Typically lead acid batteries start to lose capacity and fail within 3-5 years. - Lead acid batteries are electrochemical devices that require regular checks and maintenance. - Discharging and charging of a lead acid battery is an electrochemical process that ultimately results in the destruction of the lead plates (shedding) and the degradation of the electrolyte liquid. - A high battery cell temperature indicates severe internal issues and that battery replacement is required. Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Keatec Services - Preventative Maintenance - Batteries English 20170608

PROFESSIONAL SERVICES Integration of Power Solutions PROFESSIONAL SERVICES Site Audits, Needs Analysis and System Design Integration of DC Power Plant with Distribution Integration of AC UPS with Distribution Custom Outdoor Power System Enclosures Custom Indoor Battery Racks and Outdoor Enclosures - Free up key resources with delivery of a turnkey system - Accelerate your schedule by having systems manufactured in parallel with site works - Decrease rework and time spent at remote sites with pre-tested systems - Increase quality and finish with factory manufactured enclosures - Factory applied paint can extend the service lifetime of outdoor enclosures Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Keatec Services - Integration of Power Solutions English 20170608 keatecenergy.com

PROFESSIONAL SERVICES System Capacity and Performance Audit Businesses grow, technology changes, and eventually systems require upgrading or replacement PROFESSIONAL SERVICES System Capacity Audit Performance Review Upgrade Assessment Fault Cause Discovery Surge and Ground Protection Review Cooling System Review - Eliminate faults and performance issues causing downtime and lost revenue. - Cost-effectively extend the life of assets with an upgrade or expansion. - Enhance bottom line performance by enhancing system efficiency and reliability. - Restore system to full backup runtime with fresh batteries. Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Keatec Services - System Capacity and Performance Audit English 20170608 keatecenergy.com