NOTE: Local safety codes and regulations must be considered when installing and/or operating this unit.

Similar documents
Syntron EB-00 Vibratory Parts Feeder GENERAL MANUAL

Syntron F-450-C Electromagnetic Vibratory Feeder

Service Instructions. Syntron Vibrating Feeder Model: F-010-BM

Service Instructions. Syntron Light-Capacity Electromagnetic Model: F-T01-A DF-T01-A

Service Instructions. Syntron Electromagnetic Feeder Model: F-010-B DF-010-B

Service Instructions. Syntron Jogger Model: J-1-B

Service Instructions. Syntron Vibrating Feeder Model: RS-A Velocity TM

Service Instructions. Syntron Electromagnetic Vibratory Feeder Model: F-212-B

Service Instructions. DL-1-A Dental Vibrator

Service Instructions. V-9-D Vibrator

Service Instructions. Syntron TJ-2-B Jogger

Service Instructions. Syntron Electromagnetic Vibratory Feeder Model: BF-2-B/BF-2-BS BF-2-H/BF-2-HS

Service Instructions. Syntron Heavy Duty Electromagnetic Vibratory Feeders Models: F-22, FH-22, and F-88

Service Instructions. Syntron Vibrating Feeders Model: FH-24-D-HP

Service Instructions. Syntron Electromagnetic Feeder Model:BF-4-ALF and BF-4-ASLF (stainless steel hardware)

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions

TROUBLE SHOOTING VIBRATORY FEEDERS Contributed by ADI Representative: George Crawford

feeder Vibratory feeder

Thermal. Dimensions Torque Rotating. Rotating Capacity lb.ft. HPS/Min. Lb-Ft

Feeding Concepts, Inc Vibratory Feeding Equipment Troubleshooting Manual

Service Instructions. Syntron MF-200-B Electromechanical Vibratory Feeder

Bowl feeder WV401-1 / Translation of operating and installation instructions

60 Series End-Mount Brake Instructions Standard Housing

Safety Precautions. Introduction to Dyna-Slide

UNIFLO Control Valve

Installation, Operation and Maintenance Instructions

Table of Contents. 1

ELECTROMAGNETIC VIBRATORY FEEDER INSTRUCTION AND MAINTENANCE MANUAL

OHIO MODEL RD-2A AUTO/MANUAL DROP MAGNET CONTROLLER INSTALLATION, MAINTENANCE, AND PARTS BULLETIN

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)

SERVICE SHOP NOTES. Use ohmmeter to check the resistance between the leads.

INSTALLATION INSTRUCTIONS

Tech Note Truck 14 & 15.5 Twin Plate Cast Iron Type Installation Guidelines

GT-200 GATE VALVES PN16, Screwed end

Service Instructions. Syntron Pneumatic Turbine Vibrators Model: TAM TB TBM

*24828* 1 Installation. Left Hand Shown, Right Hand Opposite. Customer Service

Service Instructions. Syntron MF-1600-E Electromechanical Vibratory Feeder

Service Instructions. Syntron Electromechanical Direct Drive Vibratory Feeder Model: MF-300-C

Installation Instructions TH700-R4 (4L60) Transkit Part No thru 1986 Part No thru 1993 non-electronic models

Inertia of Rotating Parts Lb-Ft 2. Thermal Capacity HPS/Min.*

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Installation, Operation and Maintenance Instructions

OPERATING INSTRUCTIONS BULLETIN MODEL DA750 March MAGNETIC INSPECTION UNIT

Q-04: Replace Brake Shoes/Adjust Brakes

FN-27 FLASHER RELAY SERVICE MANUAL 4519 * * * * * * * * * * * * * * * *

VIBRATORY FEEDER MODELS - 52A & 56A

Timer. TipTop Timers. Installation and Operation Manual

80 Series 4 Post Brake Instructions

Jet Fans. Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY

Air Actuated Hydraulic Bottle Jacks

6200 Series. Specifications. Fluid End Power End Models 6211, 6212, 6221, & 6222 Models 6241 & 6242 Part Material Part Material Part Material

FRONT SUSPENSION GROUP 33A 33A-1 CONTENTS GENERAL DESCRIPTION... 33A-2 FRONT SUSPENSION DIAGNOSIS. 33A-3 LOWER ARM... 33A-13 SPECIAL TOOLS...

OPERATION MANUAL VCX-1

LIFTING MECHANISM PART NO SRM 965

Fisher 657 Diaphragm Actuator Sizes and 87

Operating and Maintenance Manual Gas & Diesel Engine Powered Self-Priming Trash Pumps Series

AUTO-BREEZE Cotton Candy Machine Instruction Manual Model #3052

OHIO MODELCDS AUTO/MANUAL DROP MAGNET CONTROLLER DESCRIPTION INSTALLATION PROCEDURES INSTALLATION, MAINTENANCE, AND PARTS BULLETIN

Connected To Control Box Series. Closer. Set Screw. Arm Screw. Right Hand Shown. 1/8" I.D. Air Inlet Tubing Connected To Control Box

Models Affected: Certain 2013 Model Year Propane Vision Buses Equipped with Ford 6.8L Engines CORRECTIVE ACTION ---- PROCEDURE

SL-6 & SL-6A. I UNION SWITCH & SIGNAL l[ml 645 Russell Street Batesburg, SC Service Manual Field and Shop Maintenance

DIRACT BRAKES 70 SERIES 4 POST BRAKE INSTRUCTIONS

DANGER CAUTION. 9. Brake Maintenance

G Series Hazardous Brake Instructions DESCRIPTION

VIBRATORY FEEDERS MODELS - HS-10, UHS-10, HS-20 & UHS-20

REMY TECHNICAL SERVICE BULLETIN

Operator s Manual. Nitro 1000 Nitro 1000X. Nitro 750 Nitro 750X. September REV0

MOREHOUSE INSTRUMENT COMPANY, INC. 60,000 LBS CAPACITY AIRCRAFT PART NUMBER SCALE S FORCE CALIBRATION PRESS PART NO.

TactAir 4-Stage PCP Hand Pump. Operation Manual

!"" #$% "!&' ( ( ) *

Type 657 Diaphragm Actuator Sizes and 87

Cougar B Series Electric Vibrators 3 Frame

Operating and Maintenance Manual Electric Motor Powered & Without Power 3 Diaphragm Pumps. Series

UNDERSTANDING & TROUBLESHOOTING A VIBRATORY FEED SYSTEM

Electric motor testing

Installation, Operating and Maintenance Instructions. Rotating Machine Screw Actuators. With Parts List Publication Part No.

OLYMPIAN MODEL 740 Operation and Service Manual

S3 General Installation

GROUP 33A 33A-1 CONTENTS GENERAL DESCRIPTION... 33A-2 FRONT SUSPENSION DIAGNOSIS. 33A-3 LOWER ARM... 33A-13 SPECIAL TOOLS... 33A-5

Model 7500 OPERATING INSTRUCTIONS MAINTENANCE INSTRUCTIONS. Terrco, Inc.

A2P Single Phase Automatic Industrial Battery Charger

NEW EQUIPMENT WARRANTY

AET48 Owner s Manual. TOW AERATOR Owner s Manual AET48 Beginning Serial #: Replacement Parts

Fig.01 Fig.02 Fig.03. Disassembly & Reassembly Instructions SBV-HP - Page 3

How To AC Couple Grid Tied Inverters with OutBack Frequency Shifting Inverters

HORSTMAN GREASED LIGHTNING CLUTCH

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

Owners Manual: - Pumps

GBP784B INSTALLATION TOOL

580RK SERVICE GUIDELINES For coupling models: 580 & 580J

70 Series 8700 End Mount Three Phase Brake Instructions IP43 (NEMA 2) Housing

Bowl Feeder BF10 / BF15 Translation of operating and installation instructions

MODEL 7100 PORTABLE PIN WELDER OPERATOR S MANUAL

Model 340 Tune-Up Kit Instructions

Tagger with Stand. Manual

WARNING...8 Keep glasses clean...8 Lamp replacement...8 Fuse replacement...8 Major failures...8 In summary...8 Section V. Specifications...

MGM Brakes Service Manual

Bowl feeder BF20 / BF25 / BF30 BF35 / BF40 / BF50

Transcription:

Syntron Vibratory Parts Feeder Model: Legacy UM-15 SAFETY INSTALLATION OPERATION Parts Feeder Drive Features and Benefits Spring Replacement Parts List Specifications Thank you for buying equipment from Homer City Automation Inc. This manual will help you to understand how your equipment operates and what is required to maintain peak performance. Please read it thoroughly and keep it on file for reference. Your satisfaction is important to us, so please direct any comments to our Customer Service department. SAFETY INSTRUCTIONS Product safety labels must be highly visible on the equipment. Check visibility on a regular basis. If safety labels need replaced, contact Homer City Automation Inc. for an additional supply free of charge. WARNING: These instructions and safety precautions must be followed. There is hazard of electric shock to the operator. INSTALLATION WARNING: Disconnect and lock out the power supply at the safety disconnect switch before performing any maintenance. NOTE: Local safety codes and regulations must be considered when installing and/or operating this unit. POWER SUPPLY It is important to follow the wiring diagram, supplied with the control, when making electrical connections. Voltage and frequency must match the requirements designated on the control nameplate. WARNING Before starting the machine, remove the red shipping brackets (if equipped) from the vibratory drive. WARNING The unit must be properly grounded. FEATURES AND BENEFITS The Syntron Vibratory Parts Feeder Drive Model UM-15 features a round base construction with three spring stacks, and a single, center mount coil and armature. This unit operates at lower current than other syntron parts feeder models, making it possible for a more cost efficient control to be used. The circular design makes installation of the drive unit in confined places easy and fast. Three rubber isolator feet are provided for isolation of vibration between the drive unit and the mounting structure. The accessible rubber isolators are adjustable one-quarter inch up or down to achieve bowl discharge height, and are adjusted and locked on top of the base plate. This three-point mounting feature provides an even weight distribution of the drive unit, producing a high degree of stability. 2010 Homer City Automation, Inc. All rights reserved. SM0664 082010 1

Various sizes of bowls can be mounted to the drive unit. Mounting methods include center mount or threepoint toe clamp arrangements. The three-point contact feature greatly reduces stress in the bowl, allowing for better feed characteristics. Optional base weights can be added to the drive unit to increase the weight mass of the base when larger and heavier bowls are used, making this drive unit very versatile. Optional drive-unit covers are also available and can be supplied for additional protection of the drive unit components as well as overall aesthetic appearance. SPRING REPLACEMENT GUIDE The Model UM-15 incorporates three spring stacks. Replace or rebuild only one stack at a time. This permits the remaining stacks to serve as support for the upper mass (bowl and crossarm/armature assembly), during the replacement procedure. WARNING Disconnect and lock out the power supply at the safety disconnect switch before performing any maintenance. 1. Proper arrangement of the spring stacks is critical to optimize feeder operation. Before removing a spring stack, match-mark each spring stack at the top and bottom so that the original arrangement can be maintained. 2. Remove both clamp bolts (H), clamp blocks (G), all spacers (E) and leaf springs (F). Important: When removing these items, take special note of their location in the stack arrangement. Spring and spacer requirements may vary depending on the unit To avoid premature spring failure, assemble the thickest springs to the stack first, followed by the thinnest springs. 3. Examine each leaf spring, one at a time, for signs of fatigue or defects (breaks, hairline fractures, rust, etc.). CAUTION: All of the spring stacks should be carefully examined. Always replace a defective spring with a new spring of the same thickness and width. 4. When reassembling a spring stack, it is important to isolate each spring with spring spacers at both the top and the bottom mounting locations, and to verify that the springs are in their correct locations. Attempt to balance spring strength in each stack. 5. With all springs, spring spacers and clamp blocks in position and aligned, insert and tighten the top and bottom clamp bolts. WARNING: Never oil the spring assembly. If the spring stacks are repainted, be sure no paint is applied to the area between the spring clamping surfaces. 6. Tighten each clamping bolt (H) evenly, then torque to the recommended 110 ft/lbs. 7. Connect the electrical supply and refer to the (AIR GAP ADJUSTMENT) below. 2

AIR GAP ADJUSTMENTS The air gap of a vibratory feeder is the spacing between the armature face and the face of the magnet core assembly. Proper adjustment is critical for optimum feeder performance. If the air gap is adjusted too close, the armature and core will make contact during feeder operation, causing striking. WARNING: A striking condition will cause severe mechanical damage; broken springs, cracked bowl, crossarm, armature or magnet core. If the air gap is adjusted so that the armature and core are too far apart, the unit will draw high amperage and result in coil burn-out, failure of control components, or poor of bowl stroke and part feed rate. The air gap is properly set at the factory. However, if the air gap has been moved, due to improper handling or rebuilding of drive unit, adjustment may be necessary. NOTE: Do not operate the feeder while the air gap is being adjusted. WARNING: Disconnect and lock out the power supply at the safety disconnect switch before performing any maintenance. 1. Turn off the power to the unit and loosen the three socket head cap screws (J) which secure the coil mounting plate to the base plate. (Loosen each cap screw approximately one half turn). 2. Using the three socket head set screws (L), adjust the coil mounting plate in the required direction (either closer to or farther away from the armature assembly) a little at a time and equally on each side to obtain an initial.025 inch air gap between coil and armature. 3. When adjusting the air gap, never set the gap so close that a striking condition results. Never set the gap so wide that rated current is exceeded. 4. After achieving the initial.025 inch air gap, reconnect power to the unit and operate the unit to observe feed characteristics. If the feed rate is too low, repeat the adjustment procedure to decrease the air gap.005 inch at a time to achieve a higher feed rate. After each air gap adjustment, tighten the socket head cap screws (J) securing the magnet mounting plate to the base. Feeder Amperage When measuring the amperage of a feeder, a clamp-on ampmeter does not reveal the same current as stamped on the equipment nameplate. This is due to the waveform characteristics of the rectified current (RC) feeder operation. To obtain a true amperage reading, multiply the clamp-on ampmeter reading by 1.7. PARTS FEEDER SPECIFICATIONS Maximum amperage draw 2.5 (Not to exceed) Recommended air gap setting -.025 inch Drive spring torque - 110 ft-lbs. 3

4

Parts List - Vibratory Parts Feeder MODEL: UM-15-S and UM-15-L ITEM DESCRIPTION QUANTITY PART NO. A Top Plate and Armature Assy. UM-15-S Counter Clockwise 1 223173-A Clockwise 1 223173-B UM-15-L Counter Clockwise 1 223202-A Clockwise 1 223202-B B Magnet Assembly 115V/60HZ 1 223185-B 230V/60HZ 1 223185-C 115V/50HZ 1 223185-D 230V/50HZ 1 223185-E C Magnet Mounting Plate 1 223166-1 D Base Assembly Counter Clockwise 1 223172-A Clockwise 1 223172-B E Spacer AS REQ'D 182648-C F Leaf Spring 3/32" Thick AS REQ'D 182548-C 1/8" Thick AS REQ'D 182548-H 3/16" Thick AS REQ'D 182548-G 1/4" Thick AS REQ'D 182458-D G Clamp Block 6 182649-C H Cap Screw HX HD, GR. 8 1/2-13 x 1-1/2" AS REQ'D H0320809 1/2-13 x 1-3/4" AS REQ'D H0315609 1/2-13 x 2" AS REQ'D H0303509 1/2-13 x 2-1/4" AS REQ'D H0321709 1/2-13 x 2-1/2" AS REQ'D H0304509 J HX SOC HD Screw 1/2-13 x 2" 3 H0424900 K Lockwasher 3 H0113609 L Set Screw HX SOC CUP 1/2-13 x 1 1/2" 3 H0457300 M HX SOC HD Screw 5/16-18 x 1" (secure with lock-tite) 4 H0419100 N Isolator Foot 3 223209-1 P Foot Locator 3 223204-1 R HX Jam Nut 1/2-13 3 H0104004 S Bowl Mounting Assy. (NOT SHOWN) When Mounting 10" O.T., 15" O.T., & 24" Cascade Bowls 1 When Mounting 12" O.T. Bowl 1 When Mounting 24" Cast Aluminum Cascade Bowl 1 T * Warning Label 1 125694 V * Name Plate 1 223240 W * Torque Label 1 183986 X * Stroke Gage (NOT SHOWN) 1 58462 Y * Air Gap Adjustment Label Optional Covers (Not Shown) 5 1 1 195774 Consult Factory * Do not remove or paint over safety labels or name plate. If safety labels need replaced, contact Homer City Automation for an extra supply free of charge.

Homer City Automation, Inc. 57 Cooper Avenue Homer City, PA 15748 Phone (724)-479-4503 FAX: (724)-479-4767 Email: info@homercityautomation.com Web: www.homercityautomation.com Homer City Automation, Inc. reserves the right to alter at any time, without notice and without liability or other obligations on its part, materials, equipment specifications and models. Homer City Automation, Inc. also reserves the right to discontinue the manufacture of models, parts, and components thereof. 6