IAX/LUX/LEX Series Low-Depth, Hydraulic-Magnetic Circuit Breakers. Introduction Configurations Delay Curves Operating Characteristics Decision Tables

Similar documents
209 Series. Magnetic Circuit Protectors

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables

209/219/229/249/279 Series Magnetic Circuit Protectors

Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 Operating Characteristics 73

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

AP/UP, AP/MIL Series Magnetic Circuit Protectors

PD-Series Ground Fault Circuit Protection

IAL/IUL/IEL/LEL Series Magnetic Circuit Protectors

AP/UP, AP/MIL Series Magnetic Circuit Protectors

These devices meet the requirements of OSHA 29 CFR (b)(1)(ii) and OSHA 29 CFR (a) (2)(ii)(G). Airpax LEL series

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker

PB-Series. GFCI/ELCI & Panel Seal

G-Series. Circuit Breaker.

Magnetic and Hydraulic-Magnetic Circuit Breaker

SAR & SAS Circuit Protectors

FR circuit breaker - hydraulic magnetic,

AR circuit breaker - Hydraulic magnetic,

Catalog Issued 3-03 (PDF Rev )

Single Pole Circuit Breakers 107 Multi-Pole Circuit Breakers 108 IAGX/IUGX/IEGX/CEGX/ IAGZX/IUGZX/IEGZX/CEGZX Breakers 110 IAGBX/IUGBX/IEGBX/CEGBX

SAR/SAS Series Hydraulic Magnetic Circuit Protectors

Magnetic Overcurrent Circuit Breaker

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

CX-Series. Circuit Breaker

ER circuit breaker - Hydraulic magnetic,

L-Series. Circuit Breaker

Single Pole Circuit Protectors 129. Multi-Pole Circuit Protectors 130. BX Style Circuit Protectors 131. High-Current Magnetic Circuit Protectors 132

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

PDR circuit breaker - Ground fault Datasheet

F-Series. Circuit Breaker

F-Series. Circuit Breaker

1492-CB 1492-GH 1492-GS

Circuit Breakers Series AM/S

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

G-Series DIN-RAIL CIRCUIT BREAKER

DD Frame - Series Circuit Breakers

Transfer switch OTEC open or delayed transition

J-Series CIRCUIT BREAKER

Series L9 UL-489 Miniature Circuit Breakers

Electronic Circuit Breaker ESS20-0..

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

1.0 Installation Wiring

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

H-Series. Circuit Breaker.

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

TMC 91H is now TMC 60 C Series

Miniature circuit breaker Application guide

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Miniature Circuit Breakers

Switchboards Instant Service

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

OTEC Transfer switch open transition

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

MERCURY CONTACTORS & RELAYS

Products :: Circuit Protection :: Thermal Circuit Breakers

Tmax Molded Case Circuit Breakers

MDS2 Series. Modular Distribution Systems. Introduction 8-Position Configuration Decision Tables

Flexible, Customizable Power Solutions for Mission Critical Success

Tmax Molded Case Circuit Breakers

Flexible, Customizable Power Solutions for Mission Critical Success

Motor Circuit Breakers C4

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Thermal-Magnetic Circuit Breaker 201/-WA

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

Close-Open (Short-Circuit) Time Results Interpretation

FACT SHEET Standard: Electrical Safety

Product Line Overview. The Most Logically Designed Contact Assembly

Selection Guide Motor Control Device Solutions

MS-Series. Circuit Breaker

ARC-ALERT CIRCUIT INTERRUPTER TECHNOLOGY NEXT GENERATION OF CIRCUIT PROTECTION

Control Circuit Protection

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Micro Contactor MA Series

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

Selection Guide. Control Circuit and Load Protection

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

CR circuit breaker - hydraulic magnetic,

Series C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker

Guide to Power Protection. Guide to Power Protection

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

UMBW-UL489 and UL1077 Listed

Flexible, Customizable Power Solutions for Mission Critical Success

Section. Circuit Breakers Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series...

Electromagnetic Industries LLP

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

Essential equipment for all your requirements

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

Manual Reset Limit Switch

Transcription:

IAX/LUX/LEX Series Low-Depth, Hydraulic-Magnetic Circuit Breakers Introduction Configurations Delay Curves Operating Characteristics Decision Tables 23 24 27 28 29

IAX/LUX/LEX Series Low-Depth, Hydraulic-Magnetic Circuit Breakers INTRODUCTION Our lowest depth breaker family, the Airpax IAX/LUX/LEX series hydraulic magnetic circuit breaker allows increased density in datacenter rack power distribution units while leaving more space for equipment, wiring and airflow. These UL-489 Listed and IEC 60947-2 (pending) breakers are available in and 2 pole models using a unique handle actuator (patent pending) which minimizes breaker volume while maintaining reliable switching and over current protection. Available high interrupt capacity 0 kaic and low resistance all copper conductors meet the needs of high performing, high efficiency datacenters. FEATURES Based on the proven high performance of the Airpax LEG series Low depth to minimize PDU intrusion into equipment rack space 240VAC rating on a single pole further minimizes space requirements UL-489 Listed and IEC 60947-2 (pending) 5 kaic and 0 kaic versions available Standard (copper and brass) and low resistance (all copper) conductors available Unique handle actuator for protection against accidental turn-off with minimal size and no handle guard required Screw terminals provide secure vibration resistant connection for high reliability applications Terminal orientation allows simple power conductor routing and ease of assembly 23 IAX Series - Introduction http://airpax.sensata.com

LEX (Low-Depth) CONFIGURATIONS. Low Depth style screw terminals. 2. Barriers deflect to allow easy wiring access. IAX Series - Configurations 24

DELAY CURVES 50/60Hz Short Delay 0000 50/60Hz Medium Delay 0000 000 00 DELAY 6 000 00 DELAY 62 0. 0..0.0.00 0 00 50 200 300 400 500 600 700 800 900 000 25.00 0 00 50 200 300 400 500 600 700 800 900 000 25 50/60Hz Long Delay (Motor Start) 50/60Hz 25% Instant Trip 0000 000 DELAY 63 0000 000 DELAY 69 00 00 0. 0..0.0.00 0 00 50 200 300 400 500 600 700 800 900 000 25.00 0 00 50 200 300 400 500 600 700 800 900 000 25 27 IAX Series - Delay Curves http://airpax.sensata.com

PERCENTAGE OF RATED CURRENT VS TRIP LEX (Low-Depth) Delay 00% 25% 50% 200% 400% 600% 800% 000% 6 No Trip.7-2.35-7.30-3.030-.05-.3.0-.5.0-. 62 No Trip 0-20 6-60 2-20.2-3.05-2.05-.8.0-25 63 No Trip 50-700 30-400 0-50.5-20.05-0.03-.85.03-.5 69 No Trip.20 MAX..00 MAX..050 MAX..022 MAX..07 MAX..07 MAX..07 MAX. TYPICAL RESISTANCE / IMPEDANCE Current Rating (Amps) Standard DC Resistance - Ohms All Copper 2.0.400.385 4.0.0098.009 5.0.0075.0070 20.0.0049.0046 30.0.0027.0024 DCR and Impedance based on 00% rated current applied and stabilized for a minimum of one hour. Tolerance 2.0-2.5 amperes ± 20%: 2.6-20. amperes ± 25%, 2.-30. amperes ± 50%. Consult Sensata for special values and for coil impedance of delays not shown. INRUSH PULSE TOLERANCE Delay Pulse Tolerance 6, 62, 63 0 times rated current (approx) The table above provides a comparison of inrush pulse tolerance for each of the 50/60Hz delays. Pulse tolerance is defined as a single pulse of half sine wave peak current amplitude of 8 milliseconds duration that will not trip the circuit breaker. Consult Sensata for further assistance. AGENCY APPROVALS - LUX CIRCUIT BREAKERS Max Voltage Frequency (Hz) Phase Minimum Poles UL/CSA rated current UL489 short circuit 240 50/60 2-30 5,000 240 50/60 only 5-30 0,000 240 50/60 2 only 2-30 0,000 IAX Series - Operating Characteristics 28

DECISION TABLES LUX LUXH IAX IAXH 2 First Decision Type. Individual units riveted together as a single unit are indicated by M following the type (e.g. LUXHM). Must be handles in all poles. No mechanical linkage is provided between units. 2. See ratings table for specific rating values. Second Decision Poles Screw Terminals Low Depth Single pole Two pole One handle per pole Single pole Two pole One handle per pole U.L. listed per 489, C22.2 No. 5 Special customer variation not covered by agency approvals. Example: LUXHA66--6-20.0-NR-0 2 3 4 5 6 7 5 8.0 5.0 6.0 20.0 25.0 30.0 6 -A -N -R Fifth Decision 8 amp 5 amp 6 amp 20 amp 25 amp 30 amp For other ratings, contact Sensata. Sixth Decision Miscellaneous Metric thread mounting, terminals and screws. All copper option 0kAIC. One or more descriptors may be used as required. 2. When no sixth decision is selected, ASME/ ANSI threads will be supplied. A6 Single Pole A66 Third Decision Construction Two Pole. Screw terminals are 0-32. M5 terminals are available as an option in the sixth decision. 3 - Series 4-6 -62-63 -69 Fourth Decision Frequency & Delay 50/60 short delay 50/60 long delay 50/60 extra long / motor start 50/60 25% instant trip 7 Seventh Decision Marked (Combination On - Off / I-O) -0 Black with white markings 29 IAX Series - Decision Tables http://airpax.sensata.com