SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

Similar documents
SLiC Aerial Closures

3 Reenterable Encapsulated PST Dome Closure

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

3M Closure System 2-Type Cover (505)

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

3M Cross-Connect Cabinets 4220SVC and 4220SVE Tall Skirt Installation Guide

3M Locator Plate

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TS (RW)

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW)

Cable Ties. Data Sheet

3M Fiber Dome Closure FDC 10

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT

710 Splicing Rig. Instructions. January E

Cold Shrink Silicone Rubber Termination QT-III 7672-S-8-JCN

Motor Lead Pigtail or V-Stub Splice 5380 Series For 5/8 kv Non-Shielded and Shielded Feeder Cables (Tape, Wire or UniShield Cables)

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN

3M Cold Shrink QT-III Silicone Rubber Termination

3M Locator Plate

3M Cable Ties Product Guide. Made in USA. & Plenum Rated

Model 1100B CHG Terminator. Installation Instructions

3M Ladder Kit 3M710/MS 2 -TMK-LK

CS Fiber Optic Splice Case. Instruction

QT-III Cold Shrink Silicone Rubber

3M Mechanical Shearbolt Connectors, QCI Series

3M Cold Shrink Splice Kit QS-III 5536A

Data Sheet July For RoHS information, please visit

8400 Series Fiber Distribution System

3M Electrical Tapes Product Selection Guide. Insulate & Protect. with Quality Tapes. Preliminary

DOCUMENT OBSOLETE. 3M710 UniPresser for 25-Pair Modular Splicing. Instructions. April B

3M Products for Electrical Networks Wind Farm Capabilities. Leading Edge. Electrical Solutions for. Wind Farms

3M Electrical Markets Division. Rubber, Mastic and Specialty Tapes Application Guide. Choose the. Right Tape. for your. Electrical Project

Volition. VF-45 Quick Install kit. and Maintenance Cleaning Kit. 3Innovation

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

Cold Shrink QS T Trifurcating Transition Splice Kit

QS-III. 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits. Data Sheet CAUTION. 1. Product Description. 2. Applications.

3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series

Branch Splice QS-2001B

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A

COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications

Cold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief)

3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable

3M Mini D Ribbon (MDR) Cable Assembly.050 High Speed Video Data Transmission System, 50 Position 14X50-SZWB-XXX-0NC

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kits

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

3M Cold Shrink QT-III Silicone Rubber Indoor Tubular Termination Kit

3M Cold Shrink QT-III Silicone Rubber Indoor Termination Kits With High-K Stress Relief

3M Cold Shrink QT-lll Silicone Rubber Skirted Termination Kit 7692-S-4, 7693-S-4, 7694-S-4, 7695-S-4, 7696-S-4

3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900-µm. Instructions. October C

3M Pleated Foil I/O Cable Assemblies MDR Series

Volition. Fiber Optic Cable. 3Innovation

Cold Shrink QS2013-3T-WS Trifurcating Transition Splice Kit

COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

3M Textool Test and Burn-In Sockets for 1.0 mm Area Array Packages Including Ball Grid Array and Land Grid Array

1 GENERAL INFORMATION

3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900 µm Instructions

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

JANUARY 2015 NOMENCLATURE. TOOLS REQUIRED 3/8" & 7/16" Can wrench or socket 1/4 Nut driver or screwdriver Snips Fiber optic cable opening tools

COYOTE Dome Closure 6.5" x 22" Kits. COYOTE Dome Closure 6.5" x 22" for Buffer Tube Applications. Includes: (2) Grommets, (1) Buffer

Scale Feeder Manifold Water Filtration System Instruction Manual

COYOTE Terminal Dome Closure 6.5" x 22"

C Power Connection Kit

3 980/980E Ionized Air Gun Instruction Manual

3M No Polish LC Connector SM and MM, Flat Splice, 250/900 µm

3M Cold Shrink QT-II Silicone Rubber Indoor Termination Kits

3M No Polish LC/APC Connector SM, Angle Splice, 250/900 µm 8830-APC/AS

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

Dual Flow Manifold Systems Instruction Manual

Repair Method for 3M Resilient Floor Protection System

GM Specification Annual Test Data

3M Cold Shrink QT-lll Silicone Rubber Indoor Tubular Termination Kits With High-K Stress Relief

3M Cold Shrink QT-III Silicone Rubber Termination Kits 7640-T and 7650-T Series 5, 8, 15, 25/28 and 35 kv

POWERHEAT TYPE AHT TERMINATION INSTRUCTIONS. Ref TK/AHT Issue C Date 16 August 1999

GM Specification Annual Test Data

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

Door Edge Protection Film 36 inch

American Standard ProAx Triaxial Camera Connectors Installation Instructions

EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions

3 740 Wrist strap + shoe tester

3M Cold Shrink Splice Kits, QS T Series

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit With High-K Stress Relief

3M Cushion-Mount Plus Plate Mounting Tapes with Easy Mount Adhesive

3M TM Cubitron TM II Bonded Abrasive Grinding and Cut-Off Wheels. born to. grind. It s grinding reinvented. Featuring. cut & grind wheels

COYOTE Dome Cross-Connect Closure 6-1/2" x 22"

AccuGlide. HST 3-Inch HST 3-Inch Taping Heads. Instructions and Parts List. Important Safeguards. Important. Type 29100

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

Dual/Triple Manifold Water Filtration Systems Instruction Manual

HTP PTP/ PTJ Power Connection Kit for Pipes

COYOTE LCC (Low Count Closure)

CommScope MULTILAYERED 289-TYPE INSTALLATION INSTRUCTIONS

Full Flow Drinking Water System Model: 3MFF100

COYOTE CLOSURE ADOBE SERIES FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (152.4 mm x mm mm x 558.

protect mask conduct reflect enhance 3M Specialty Tape Solutions

Dual Port Manifold Water Filtration Systems Instruction Manual

SJOF-BS604A Fiber Optic Splice Closure User Manual Rev.0

3MTM CubitronTM II Bonded Abrasive Grinding and Cut-Off Wheels. BORN TO GRIND. IT S GRINDING REINVENTED.

Transcription:

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks Instructions June 2002 78-8130-2161-1-B 1

Contents: 1.0 General... 3 2.0 Kit Contents... 3 3.0 Cable Preparation... 3 4.0 Terminal Block Installation... 4 5.0 Terminal Installation, Bonding and Splicing... 4 6.0 End Seal Installation... 4 7.0 Terminal Assembly... 6 8.0 Drop Wire Termination... 6 9.0 Testing... 7 10.0 Extending Terminal... 7 11.0 Lug Assembly Replacement... 8 12.0 Accessories... 8 A B C Size A 328 28" (711 mm ) 9.0" (229 mm) 6.4" (163 mm) 530 30" (762 mm) 10.4" (264 mm) 8.6" (218 mm) B C Cut with scissors M IL L I M E T E R S R A N G E I N C H E S.4 10 15.6 20.8 25 1.0 2 30 1.2 35 1.4 40 1.6 45 1.8 50 2.0 55 2.2 60 2.4

1.0 General 1.01 The 3M brand SLiC TM Aerial Terminals and Spiral End Seal made for use with AMP* Quiet Front terminal blocks, and with external bonding hanger brackets, are designed for fixed count terminating up to 25 pair. Two terminal sizes are available: 3" x 28" (76 mm x 711 mm) and 5" x 30" (127 mm x 762 mm). They are available empty or with an AMP Quiet Front IDC Terminal Block in a configuration of either 5, 10, 15 or 25- pair. They can accommodate a 3" (76 mm) or 5" (127 mm) diameter splice bundle and cable up to 2.67" (68 mm) diameter or 3.00" (76 mm) diameter respectively. 1.02 The AMP Quiet Front Terminal Block is designed to connect telephone distribution lines (air core or grease filled shielded cable) with individual drop wires. The blocks are CSA certified and UL listed communication circuit accessories. They can be grease or gel sealed. 2.0 Kit Contents Bond Bar 2.01 Kit Contents are as follows: Bond Bar Braid Assembly Terminal Body Spiral End Seals 2.02 Additional Materials Required: Shield Connectors Cable Ties Cable Spacers Moisture Resistant Splicing Connectors Vinyl Tape End Seal (2) Braid Assembly (2) Terminal Body 3.0 Cable Preparation 3.01 Prepare cable and strand. 20" (508 mm) Split Web Approx. 91" (2.3 m) Self-Supporting Cable 18" (457 mm) 63" (1.6 m) 2" (51 mm) 10" (254 mm) Double Jacket Cable Sheath Opening Outer Jacket 14" (355 mm) 2" (51 mm) Outer Jacket 14" (355 mm) 2" (51 mm) Lashing Wire Clamp Lashed Cable Support on Self-Supporting Cable Lashed Cable Support and Spacer (Use approximate size cable spacer to keep cable at same level or slightly lower than end seals) Trim core wrap to extend approximately 1" (25 mm) past outer sheath. If core wrap is damaged, wrap with vinyl tape. 1" (25 mm) 12" 1" (25 mm) (305 mm) Inner Jacket 3

4.0 Terminal Block Installation 4.01 Select and punch through proper mounting configuration in terminal box for desired AMP terminal block(s). Proper mounting configuration for different pair counts are indicated by the bold circles. 5-Pair Block Mounting Screw Locations Wire Exit Locations 4.02 Feed terminal block tail(s) through appropriate hole(s) in box leading to splice chamber. Feed hole for the tail is larger and sits above and between mounting holes. 4.03 Mount the 5-pair block(s) with two mounting screws and two hex nuts positioned in the far left and right holes on block(s). Use three mounting screws and hex nuts for 25- pair block, (two at each end and one just to the bottom right of the tail hole). 10-Pair Block 10-Pair using Two 5-Pair Blocks 15-Pair Block 15-Pair using One 10-Pair and One 5-Pair Block 15-Pair using Three 5-Pair Blocks 20-Pair Block 20-Pair using Two 10-Pair Blocks Bond Bar 20-Pair using One 15-Pair and One 5-Pair Block 25-Pair Block 5.0 Terminal Installation, Bonding and Splicing 5.01 Attach terminal to strand using the proper position at the bottom of the external bond hanger bracket. Always use bottom notch with small groove. For 10M strand and larger, rotate hanger cap and use large groove. Secure the hanger brackets to strand using 50 in lbs (5.65 N m) torque. For self-supporting cable, tighten to 105 in lbs - 115 in lbs (11.86 N m - 12.99 N m) torque. 5.02 Install shield connectors and attach braid from terminal body. 5.03 Splice block tail(s) to selected cable pairs per standard procedure. 6.0 End Seal Installation 6.01 Remove plugs for the desired number of cables to be installed. Use appropriate port as needed for cable size to be installed (Check cable range shown on end seal). 4

Spiral End Seal Port Diameter Range 3 X 28 5 X30 Port 1... 0.8" to 2.6" 1.2" to 3.0" 20 mm to 66 mm 30mm to 76 mm Port 2... 0.5" to 1.0" 0.8" to 1.4" 13 mm to 25 mm 20 mm to 36 mm Port 3... 0.5" to 1.0" 1.4" to 2.0" 13 mm to 25 mm 36 mm to 51 mm Port 4... N/A 0.5" to 1.2" 13 mm to 30 mm 6.02 Install end seal on cable and put one wrap of vinyl tape around center of end seal. Distance required between end seals shown below. Do not wrap endseal or vinyl tape tightly. Distance Between End SLiC Seal Centers 3x28 5x30 24" (610 mm) 26" (660 mm) Location of end seal in SLiCs is not flush with end. 6.03 Cut on dotted line, if necessary, according to the following chart: SLiC 3x28 5x30 If end seal bundle size is >3.8 (97 mm) >5.8 (147 mm) Cut method and location indicated by dotted line on each End Seal. 6.04 Cutting is optional, but makes closing of closure easier with larger diameter cable configurations. If cutting is not performed, then compress SLiC end by using knife to slit through thin plastic membrane. 5

Then place a heavy duty cable tie,hose clamps or metal banding through the slit on each end and tighten to secure and compress seal. 6.05 For sheath repair of cables larger than maximum diameter as shown on end seal, cut tail until end seal bundle diameter is approximately 0.3 to 0.5" (8 mm to 13 mm) greater than diameter of SLiC; i.e., SLiC 3 x 33 should have a maximum end seal bundle in the range of 3.3 to 3.5" (84 mm to 89 mm). 7.0 Terminal Assembly 7.01 Tie splice bundle and cable ends to bond bar. 7.02 Close latches to seal assembly. White cable ties used for clarity only. 8.0 Drop Wire Termination 8.01 Open terminal box door. 8.02 Use the slitter provided in the terminal to split the ends of the drop wire leads approximately 2" (51 mm). There are two slots in the slitter, the top slot is for mini-drop and the bottom slot is for regular drop. Do not strip insulation. 8.03 Dress wires, staggering lead lengths by cutting according to dimension shown. 3/8" (10 mm) 1" (25 mm) 2" (51 mm) 8.04 Insert shorter wire into hole on tip (T) terminal post, and rotate the lug CLOCKWISE 1/4 turn with a 216 c (7/16" or 11 mm) terminal wrench. Be sure to insert wire until it stops. Hold wire in place while terminating. Turn lug 1/4 turn only. DO NOT over torque. 6

8.05 Insert longer wire into the hole on ring (R) terminal post, and rotate lug CLOCKWISE 1/4 turn with a 216 c (7/16" or 11 mm) terminal wrench. Carefully follow safety, health, and disposal information for AMP Sealant given on label or Material Safety Data Sheet. 8.06 An additional conductor can be inserted in each terminal post by rotating lug COUNTERCLOCKWISE 1/4 turn and inserting wire into the empty hole and then turning the lug CLOCKWISE. (A previously terminated wire should have 1/4" (6 mm) cut off length to provide a new end for retermination). 8.07 Complete termination log. 8.08 Close door and check for proper sealing. 9.0 Testing 9.01 Insert test clips into test ports and follow company procedure for testing. 10.0 Extending Terminal 10.01 To extend, use a standard SLiC 3 x 33 or 5 x 33 Aerial Closure. 10.02 Remove bond bar with tubing from closure and cut 6" (152 mm) from end. 10.03 Cut closure using center mark as a guide. Each cut half section will only fit over similar end of terminal body. 10.04 Install bond bar with tubing back on closure half. Use piece of braid from aerial terminal and attach to shield connector, or cut new braid to reach full length of extended splice opening. 10.05 Install half section over end of terminal body. 10.06 Reposition end seal in extended body, close latches to seal. White cable ties used for clarity only. 2.6 65 70 75 80 85 90 95 2.8 3.0 3.2 3.4 3.6 3.8 7

11.0 Lug Assembly Replacement 11.01 If lug needs to be replaced with red (priority circuit) lug, apply inward pressure to lug with 216 c (7/16") (11 mm) or equivalent wrench and turn lug 1/4 turn counterclockwise to open position. 11.02 Remove any conductors. 11.03 Use needle nose pliers to grasp only lug assembly (plastic lug and metal test tab) through test port. Carefully follow safety, health, and disposal information for AMP Sealant given on label or Material Safety Data Sheet. 11.04 Pull lug assembly straight out of post. 11.05 Select replacement lug assembly and place in open post. (Open position when access hole is in front). 11.06 Press down on top of lug assembly to seat in terminal block base. Lug assembly must be in the open position. 11.07 If additional sealant is needed, use AMP Sealant No. 769141-1. 11.08 Terminate drop wire as described in Section 8.0. 12.0 Accessories 12.01 AC-HB1 Aerial Closure Offset Hanger Bracket AC-HB2 Extended Hanger Bracket Designed to support and bond the SLiC Terminals to the messenger strand when there is more than one cable supported by the messenger. AC-HB2 Cap and Bolt AC-HB1 * "AMP" is a trademark of AMP Incorporated. Reprinted with the permission of AMP Incorporated. Important Notice Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture as of the date of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential regardless of the legal theory asserted. Telecom Access Division 3M Telecommunications 6801 River Place Blvd. Austin, TX 78726-9000 800/426-8688 www.3m.com/telecom Printed on 50% recycled paper with 10% post consumer 8 Litho in USA 3M IPC 2002 78-8130-2161-1-B