Preassembled manifolds with flow meter, series CPRFL

Similar documents
Fan-coil valves Series

Preassembled fixed-point control, distribution and pumping unit for radiant panel heating systems DOMORADIANT Series

MVD, MV, MKV, MKL, 2161C, MXV Series

FO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com

Art.918C Pre-assembled manifold with flow meters, air

TECHNICAL CATALOGUE DISTRIBUTION MANIFOLDS

CT3202.0_01 EN February 2018

22C, 22CX, 22CX5, 26LC Series

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/18 GB. replaces 01260/14 GB

HERZ-Motorised flow controler

CALEFFI. Composite manifolds specifically designed for radiant panel systems. 670 series 01126/18 GB. replaces dp 01126/11 GB.

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

SINGLE MANIFOLDS TECHNICAL DATA SHEET10/ ENG

Components for central heating

CALEFFI. Modulating temperature regulating unit with distribution kit for primary circuit. 171 series 01153/15 GB. replaces 01153/07 GB

WAY MOTORISED COMPACT ZONE VALVES

savings flexibility recyclable LIGHTNESS FULL FLOW MECHANICAL STRENGTH IMPROVE CONTROL TECHNICAL BROCHURE aesthetic performance CHANGE

CALEFFI. Manifolds in composite specifically designed for radiant panel systems. 670 series 01126/05 GB. Function

ZONE CONTROLE / 2-WAY

CALEFFI. Direct supply unit for heating systems. 165 series 01237/17 GB. replaces dp 01237/15 GB. Function

Valves, controls + systems Valves and controls for solar installations Regusol-180

80% Max working pressure: Max working temperature: 70 C. Flow-meter regulation range: Flow meter-regulation range: ± 10%

DISTRIBUTION GROUP WITH THERMOSTATIC REGULATION. Upper connections G1 F Without fittings Fittings with running connection* Without pump

VG6000 Series Forged Brass Valves

EMUJC Series. Electronic actuator. Technical Data Sheet. WattsIndustries.com

K35 HeatBloC with 3-temperature mixing valve

CALEFFI. Pre-assembled distribution manifold for radiant panel systems S1 series 01144/11 GB. Replaces 01144/07 GB.

TDU.3 floor distribution unit SK

Pressure independent balancing and control valve For ON/OFF control

MrPEX 1 ¼ Stainless Steel Manifold. Installation Guide

LK Manifold Shunt VS2

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.

IsoTherm FlowGuards Mini Ball Valves Gauges Aquastats Unions

T2 Wall Hung Radiator & UFH Manifolds

MANUAL VALVES LOCKSHIELD

MANIFOLDS AND DISTRIBUTION EQUIPMENT

COMPONENTS FOR SOLAR THERMAL SYSTEMS

Technote. Frese OPTIMIZER - pressure independent 4-pipe coil control unit. Application. Benefits. Features.

Pump group DN 25 SA, SMTC, SMT. Mounting and operating instruction

Thermostatically controllable valves art. VD/VS/VCR/VCD/VCS xxxx

CALEFFI. Motorised temperature regulating unit for heating and air conditioning systems WYP UPM series 01254/17 GB

CALEFFI. Pre-assembled distribution manifolds for radiant panel systems. series 663 & /05 NA. Function

FCU Floor Control Unit

TECHNICAL CATALOGUE EUROPA CHECK AND FOOT VALVES

Electro Controls. Valves / Linkages WattsIndustries.co.uk

Pump Stations for Heating Circuits

STAINLESS STEEL MANIFOLDS FOR RADIANT SYSTEMS CREATION AND DIFFUSION OF THE STAINLESS STEEL MANIFOLD USE DIAGRAMS OF STAINLESS STEEL MANIFOLDS

Pre-assembled distribution manifolds for radiant panel systems

HERZ-Connect 4 / Compact Connect 4 & Commissioning Centres

ACVATIX MiniCombiValves (MCV)

PRE-ASSEMBLED MANIFOLD KIT 1 TECHNICAL DATA SHEET 10/ ENG

TECHNICAL CATALOGUE BLOCK CHECK AND FOOT VALVES

ACVATIX MiniCombiValves (MCV)

Pump group DN 32 SA, SMT. Mounting and operating instruction

COMPONENTS FOR SOLAR THERMAL SYSTEMS

CHOOSING YOUR MANIFOLD & LOCATION

Technote. Frese OPTIMA - Pressure independent control & balancing valve. Application. Features. Benefits.

TECHNICAL CATALOGUE BALL VALVES: VIENNA

TECHNICAL CATALOGUE BALL VALVES: PARIS

TECHNICAL CATALOGUE BALL VALVES: VIENNA

PRESSURE CONTROL VALVES SABS 198

CALEFFI. Ball shut-off valve fitted for integrated flow rate measuring sensor. 111 series 01234/13 GB. (kpa) (mm w.g.) G (m 3 /h)

Ðàñïðåäåëèòåëüíûé óçåë

ZTV/ZTR. Externally threaded 2- and 3-way zone valves. Function. No leakage in closed position

PRE-ASSEMBLED MANIFOLD KIT 1 TECHNICAL DATA SHEET 09/ ENG

TECHNICAL CATALOGUE BALL VALVES: IDEAL

SELF-CLEANING FILTER

CALEFFI. Pressure independent control valve (PICV) 145 series 01262/14 GB B 51

High capacity valve body, type RA-G

TECHNICAL CATALOGUE GAS BALL VALVES: BERLIN

Connection and regulation kit for HVAC terminal units

TECHNICAL SPECIFICATIONS 63/2E DN15 Kvmax /4"E. ( 3 4"x18) 3/4"E

3 & 4-Way Rotary Valves

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

Inspection boxes and accessories

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components

MIXING VALVES. art.ref. 450 art.ref. 451 art.ref. 460 art.ref.461. art.ref. 475 art.ref. 476 art.ref. W art.ref. W28.022

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.

Mikrotherm F. Manual Radiator Valves With presetting

Zone manifold DN 25, DN 32, DN 50. Mounting and operating instructions

DESCRIPTION 9.4 G 3/4"M

HYDRAULIC SEPARATOR PRODUCTION RANGE. Code Size Max. flow rate (l/h) " "1/ "1/ " 8.

Pressure Independent Control Valve

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

PRESSURE RELIEF VALVE CONTROL VALVE

G Type Range of Actuators

Automatic balancing valves ASV-PV DN (3rd gen.)

COMPLETE CONTROL IN YOUR HANDS MODULAR MANIFOLDS - QUICKER, EASIER AND MORE STRAIGHTFORWARD TO INSTALL

TECHNICAL CATALOGUE BALL VALVES: VIENNA

Installation and Operation Instructions K38 HeatBloC - DN 32

DA 50. Differential pressure controllers Adjustable set-point

CALEFFI. Mixing valves and actuators series 01169/17 GB. replaces dp 01169/09. Function

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications

TA-6-way valve. Standard control valves 6-way valve for change-over systems

Floor heating manifold with automatic flow control

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control

Installation and Operation Instructions HeatBloC K31 - DN 25

TECHNICAL CATALOGUE AUTOMATIC AIR-VENT VALVES

Transcription:

Preassembled manifolds with flow meter, series CPRFL Main features - Available in the versions with : Head connections DN./4 F Side outlet connections /4 M Centre distance between the outlet connections 0 mm - Patented flow meter for control and measurement of the water flow rate. - Low pressure drops A Division of Watts Water Technologies Inc.

Description The preassembled manifolds of the CPRFL series allow building up systems for distributing the heat carrier fluid to heating and air conditioning installations (above all for heating systems with radiant floor heating panels). The manifolds are available with NTP threading and in the following versions : Head connections /4" MF Side outlet connections /4" M Centre distance between the outlet connections 0 mm The manifolds, supplied already preassembled on brackets, are provided with : Delivery manifolds complete with flow meters series FLMR Return manifolds series 8MM Two ball shut-off valves series 0 Two end-pieces for manifolds series 8MP complete with drain cocks series 8, air vent valves series MVD and immersion thermometers series T CPRFL Preassembled manifold consisting of : delivery manifolds complete with flow meters series FLMR. Return manifolds series 8MM. Two ball shut-off valves series 0. Two end-pieces for manifolds series 8MP complete with drain cocks series 8, air vent valves series MVD and immersion thermometers serie TB. Centre distance between side outlet connections: 0 mm. N.B.: inspection box not included in the supply. Type Part number Size Outlets Weight (Kg.) CPRFL CPRFL4TM./4" F -/4" M,8 CPRFL CPRFL4TM4./4" F 4-/4" M, CPRFL CPRFL4TM./4" F -/4" M,9 CPRFL CPRFL4TM6./4" F 6-/4" M 4, CPRFL CPRFL4TM7./4" F 7-/4" M 4,9 CPRFL CPRFL4TM8./4" F 8-/4" M,6 CPRFL CPRFL4TM9./4" F 9-/4" M 7,4 CPRFL CPRFL4TM0./4" F 0-/4" M 8,6 CPRFL CPRFL4TM./4" F -/4" M 9,8 CPRFL CPRFL4TM./4" F -/4" M 0, 6 Flow meter control cap Type Description 6 Flow meter control cap Application The preassembled manifolds of the CPRFL series are used for distributing the heat carrier fluid in heating systems, above all in heating systems with radiant floor heating panels. The use of - or -way zone valves of the ZONAKIT series upstream of the preassembled manifolds (in Pic. the -way version with by-pass) and relative thermal energy metering components allows providing the manifolds of the CPRFL series with zone control and billing of the thermal energy for allocation of the running costs to each individual user.

Electrothermic zone valve Soft-sealed connection Automatic control of the branches with electrotermic actuators Return of the heat carrier fluid Connection elements of the zone and by-pass valves Flow meter for control and measuring of the flow Heat carrier fluid inlet Distribution of fluid to the user By-pass setting valve Pic. Operation The operation of the series CPRFL manifolds is based on the automatic movement of the plug shutting off the heat carrier fluid, obtained by installing electrothermic actuators, series C on the return manifolds after unscrewing the protective white cap (Pic. ). The ON/OFF action of the plug is given by a thermostat wax expansion element inside the actuators series C against a signal emitted by a room thermostat series BATTERY ELECTRONIC (or room timing chrono-thermostat series MILUX). For control and measurement of the water flow rate for each branch, use the flow meter with control cap series 6: turn clockwise for closing or reducing the flow rate or anti-clockwise for opening or increasing the flow rate. For the hydraulic flow rate and pressure drops characteristics of the manifolds, see relative tables and charts given in the following pages.

Details ) Pre-adjustment packing nut which can be replaced also when the system is under pressure. ) The manifold can be actuated with electrothermic motors series C. ) Elastomeric plug seal. Details ) Cover / NTP ) O-Ring ) Level tube 4) O-Ring (FLMR) ) O-Ring 6) Dipstick 7) Level indicator 8) Precision spring 9) Spring guide bushing 0) Washer ) Plug (FLMR) ) O-Ring ) Modular manifold 4) Seal seat ) O-Ring 6 4 4 7 8 0 9 4 A B The reliability of the manifolds series CPRFL is ensured by 00% testing of the production: testing consists of a hydraulic seal test of the manifold assembly to detect any microporosity and body resistance test at operating pressure. Technical features Kvs coeff. Side outlets 8MM.8 Liquids which can be used Water also with glycol 0% Setting and measuring range 0 6 l/min Max. temperature 90 C Operating temperature 80 C Max pressure 0 bar Outlet max. flow coefficent Kvs =.8 Reading error ± 0% f.s. i.e. ± 0.6 l/min. (with DP at the ends between 0 kpa and 0 kpa) Leakage Max. permissibile leakage with plug closed 0,0% Kvs FLMR Flow meter tightening torque 0 Nm on replacement manifold Design features Body and internal parts Plug seals O-ring Packing nut Cap for 8MM Brass CW67N EPDM EPDM Polyacetal plastic Polypropylene Hydraulic characteristics Kv values in the various preadjustment positions Setting positions 4 6 7 A 8MM./4" 0.6 0. 0.9...79.0.8 Installation Preassembled manifolds series CPRFL are inserted in inspection boxes series 89M placed in the centre of gravity position with respect to the users in order to minimize use of pipe and to ensure improved hydraulic balancing. This arrangement also allows the necessary maintenance of all components and accessories (shut-off, control and air vent valves). It is recommended: To keep the manifolds with the centre-line of the main pipe in horizontal position To install the manifold with the flow meters on the supply line and the manifold with built-in adjustment devices on the return circuit, so that the plug movement is opposite to the direction of flow. It is recommended to use special spanners (art. 89M or open-ended spanners) for tightening the fittings on the pipes and manifold joints. When the number of the user is lower than the connections available on the manifolds, plugs of the 84M series can be used.

Flow rate / Pressure drop charts Manifold with control valves. Preadjustments 8MM - DN./4" pos. 4 Kv. pos. Kv. pos. Kv 0.6 pos. Kv 0.9 pos. Kv 0. pos. 6 Kv.79 pos. 7 Kv A Kv.8 [ kpa ] [ m bar ][ mm c.a. ] 0 00 000 0 00 000 8 80 800 0 00 4 40 400 PRESSURE DROP 0.8 0. 0 0 0 00 00 00 0 0. 0 0. 0 0. 0 0 0 00 0 00 00 00 000 000 000 [ l/h ] 0 0.0 0.0 0.0 0.0 0. 0. 0. 0. [ m /h ] FLOW RATE Flow meters 0-6 l/m measurement + control 00 0 turn - Kv 0.48 0.7 turns - Kv 0.40 0. turns - Kv 0. 0. turns - Kv 0.. turns - Kv 0.66 turns - Kv 0.88. turns - Kv. turns - Kv.48. turns - Kv.68 4 turns - Kv.8 P kpa 0, 0 00 000 FLOW RATE l/h

Overall dimensions (mm) 6 CPRFL Number of Outlets L -./4 0 4 400 00 6 00 7 0 8 600 9 60 0 700 70 800 Re-order no. 68-00-UK-IT/-04/07-Rev.0 The descriptions and photographs contained in this product specification sheet are supplied by way of information only and are not binding. Watts Industries reserves the right to carry out any technical and design improvements to its products without prior notice. A Division of Watts Water Technologies Inc. Watts Industries Italia s.r.l. Via Brenno, - 0046 Biassono (MI), Italy Tel. : +9 09 49.86. - Fax : +9 09 49.86. e-mail : info@wattsindustries.it www.wattsindustries.com