Compact plastic limit switches with positive opening mechanism

Similar documents
Compact plastic limit switches with positive opening mechanism

Limit Switches with Positive Opening Mechanism

LJASeries. Limit Switches with Positive Opening Mechanism

Safety Limit Switch

Miniaturized limit switches

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Small Limit Switch D4V

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

BZSeries. Basic Switches

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

BZSeries. Basic Switches

2NC (slow-action) Direct. Model. opening

Safety Limit Switch

Basic Switches. BZ Series APPLICATIONS SELECTION GUIDE. High-quality switches with UL certification. *C-UL approval number: E96090.

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Limit Switch - Prewired Type Metal Body

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

Limit Switches - Limit Type (PS21L) Metal Body IP66

PRODUCT SPECIFICATION. Foot Switches. Series.

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

Manual Reset Limit Switch

K50H004UP cam changeover switch - 4-pole A - screw mounting

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

K30H001YP cam star-delta switch - 3-pole A - screw mounting

Limit Switches - Limit Type Plastic Body IP65

2NC (slow-action) Direct. Model. opening

Limit Switches - Limit Type Plastic Body IP65

HL (AZH) LIMIT SWITCHES

Limit switches 3. Page 92. Page 92

Limit Switches - Limit Type (PS31L) Plastic Body IP65

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

DL (AZD1) Mini Limit Switches

FL series position switches

SL1Series. Compact Horizontal Limit Switches

CSM_D4N-_R_DS_E_6_1

Microswitches M series

Mechanical Min. 20 million operations. Min. 2 million operations for the Model SL1-B. Min. 2 million operations for high oil. (All values assume overt

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

Limit Switches - Limit Type (PS42L) Plastic Body IP65

Pre wired limit switches

Miniature Pre-Leaded Vertical Enclosed Switches

HL (AZH) Limit Switches

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

Position switches FD series

Standard Interlock Safety Switches

Hinged Safety Door Switch

Safety-door Switch. Ordering Information

ED SERIES SAFETY LIMIT SWITCH Description

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

D4BS CSM_D4BS_DS_E_8_4

ED SERIES SAFETY LIMIT SWITCH

Position switches FR series

Model Number Structure

International, LLC. HMS/HLS/HNS Series Heavy Duty Limit Switches. Specifications. Features. Electrical Ratings HNS HLS HMS. Non-plug-in.

D4NH CSM_D4NH_DS_E_7_1

High sensitivity. Low current load type. type. Short plunger ~ Fine plunger ~ ~ Lever ~ Roller lever ~ Short roller lever ~

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications, type XCR. b XCR

LK Position Switches TECHNICAL DATASHEET.

Machine & Process Safeguarding Solution Selection Guide

Safety Switches & Operator Controls

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

Limit switches. Metal. Limit Switches Metal casing, 30mm, 40mm & 60mm

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

HL (AZH) Limit Switches

Prewired position switches FF series

K50F003UP cam changeover switch - 3-pole A - screw mounting

K63F003UP cam changeover switch - 3-pole A - screw mounting

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

Position switches FC series

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

OsiSense. XC Basic Limit Switches XCMN, XCKN, XCNT

Single foot switches PX and PA series

Switches with manual reset

Miniature Limit Switches

FOOT SWITCHES

D4GS-N CSM_D4GS-N_DS_E_7_2

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications XCR. b XCR

Solenoid Locking Safety Switches

1LS-J700 SERIES ULTRA LONG LIFE, GENERAL-PURPOSE COMPACT LIMIT SWITCHES

LS Series Limit Switches. Short Form Catalogue AC1300 ABB

VL (AZ8) Limit Switches

D4NS. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Model Number Structure

LJA10 Series Safety Limit Switch User's Manual LJA10-11A21N LJA10-57A21N

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

A22NK. Key-type Selector Switches

XACA871 pendant control station XAC-A - 8 pushbuttons

Transcription:

Compact limit switches with positive opening mechanism LJK-NSeries Positive opening mechanism Positive opening mechanism meets standards worldwide. A wide variety of actuators is available. The LJK-N conforms to IEC standards, and is certified by UL and CSA. For equipment and facilities to be exported anywhere in the world, use the LJK-N with confidence. Positive opening mechanism forces contacts open.* Can prevent problems caused by contact fusing. Can be used also as a safety limit switch. Wide variety, with 33 catalog listings in the lineup Actuators: types Contact configuration : : N.C. x + N.O. x 1 (BBM: break before make, N.C. x *Except for the steel wire and spring rod types. CATALOG LISTING Type of actuator Internal switch mechanism Contact configuration Resin roller lever Resin adjustable roller lever 0mm dia. resin roller lever 0mm dia. resin adjustable roller lever Plunger Resin roller plunger Resin cross roller plunger Resin one-way roller (horizontal Resin one-way roller (vertical Steel wire Spring rod N.C. x N.C. x N.C. x N.C. x N.C. x N.C. x N.C. x N.C. x N.C. x N.C. x N.C. x LJK-N18F1 LJK-N18F1 LJK-N718F1 LJK-N4F1 LJK-N4F1 LJK-N74F1 LJK-N39F1 LJK-N39F1 LJK-N739F1 LJK-N49F1 LJK-N49F1 LJK-N749F1 LJK-N10F1 LJK-N10F1 LJK-N710F1 LJK-N0F1 LJK-N0F1 LJK-N70F1 LJK-N03F1 LJK-N03F1 LJK-N703F1 LJK-NF1 LJK-NF1 LJK-N7F1 LJK-N7F1 LJK-N7F1 LJK-N77F1 LJK-N06F1 LJK-N06F1 LJK-N706F1 LJK-N08F1 LJK-N08F1 LJK-N708F1 1

INTERNAL SWITCH Snap-action type Slow-action BBM type The slow action internal switch has N.C./N.O. electrically independent contacts (form Zb. The positive opening mechanism forces the contacts open (N.C. contacts only even if they are fused. As seen above, the cam forces the N.C. contact up from the bottom, even if there is fusing of the contacts. Note: Steel wire and spring rod types do not have positive opening mechanism. SPECIFICATIONS Standards Compliance Certification Protective structure Electrical shock protection Structure Pollution degree Internal switch Electrical rating Insulation resistance Initial contact resistance Electrical Rated thermal current (Ith performance Short-circuit protection Rated insulation voltage (Ui Rated conditional short-circuit current Rated impulse withstand voltage (Uimp Impact resistance Mechanical performance Vibration resistance Max. operating speed and min. operating speed Mechanical life Life Electrical life Operating temperature Environment Operating humidity Storage temperature Conduit Recommended tightening torque Product-related: IEC 60947--1, and EN 60947--1 Machine-related: IEC 6004-1 and EN 6004-1 UL 08, CSA C. No. IP6 (IEC 609, JIS C 090 Class II (IEC 610 3 LJK-N F1: snap action, LJK-N F1 and LJK-N7 F1: slow action (See Table 1. 100MΩ or more between terminals with the same polarity and between each terminal and non-live metal part (by DC00 megger mω or less (6 to 8Vdc, thermal current 1A, measured by voltage drop method 10A 10A breaking fuse, gg (gl type 00V (IEC 60947--1, 0V (UL 08, CSA C. No. 1,000A 6,000V Durability: 00m/s Note: 0mm dia. resin adjustable roller lever types 0m/s spring rod types 00m/s IEC 60068--7 0m/s (10 to 00Hz, IEC 60068--6 (See Table. 10 million operations : 0000 operations, : 400000 operations to +7C (without freezing Max. 98% RH 40 to +7C G 1/ Body: 0. to 0.7N m (M4 Head: 0.8 to 1.N m (M3 round head screw Cover: 0.8 to 1.N m (M3 round head screw Terminal: 0.8 to 1.N m (M3. round head screw Lever: 1.3 to 1.7N m (M4 round head screw Table 1. Electrical rating AC-: A0 (Ue=40V, Ie=3A DC-: R0 (Ue=0V, Ie=0A Table. Max. operating speed and min. operating speed Actuator Contact configuration Utilization categories AC-: solenoid load DC-: solenoid load Ue: rated operating voltage Ie: rated operating current Actuator Contact configuration LJK-N F1 LJK-N F1 LJK-N7 F1 Roller lever type Plunger type One-way roller / non-directional operation types LJK-N 18F1 LJK-N 10F1 LJK-N F1 LJK-N 39F1 LJK-N 0F1 LJK-N 7F1 LJK-N 4F1 LJK-N 03F1 LJK-N 06F1 LJK-N 49F1 LJK-N 08F1 Min. speed Max. speed Min. speed Max. speed Min. speed Max. speed 0.03m/min 1.m/s 18m/min 1.m/s 18m/min 1.m/s 0.01m/min 0.m/s 0.0m/min 6m/min 0.m/s 1m/min 6m/min 0.m/s 1m/min 1m/s 1m/s 1m/s

OPERATING CHARACTERISTICS BY ROTARY OR IN-LINE ACTUATIONS OF ACTUATORS O.F.: max. operating force needed for N.C. operation Roller lever type Free position Plunger type and one-way roller type P.O.F: min. force for positive opening Non-directional operation type TT PO PT PT TT PO PT PO TT PT PT T.T.: total travel. P.T: pretravel for N.C. operation. P.T.: pretravel for N.O. operation. M.D.: minimum movement differential. P.O.: minimum travel to positive opening position. SHAPE / DIMENSIONS / OPERATING CHARACTERISTICS / CIRCUIT DIAGRAMS Resin roller lever: LJK-N18F1, LJK-N18F1, LJK-N718F1 (unit: mm 3 Roller: 19 dia. x. width, 44. 39.8 4 Roller lever can also be mounted on the opposite side. by lever rotational angle PT (pretravel for N.O. operation LJK-N18F1 LJK-N18F1 LJK-N718F1 0.N m ( (16 (7 47 0.N m (8 (38 (7 41 0.N m (7 (7 (108 3.6 4. 6 6 R. ( ( 18 R. ( 81.6 by dog operation (P LJK-N18F1 16 7 8 47 (P LJK-N18F1 38 7 0 G 1/ 37 LJK-N718F1 7 41 (P 1-1 7 (P: Min. travel to positive opening position 3

Resin adjustable roller lever: LJK-N4F1, LJK-N4F1, LJK-N74F1 (unit: mm 3 (108 to 7 Roller: 19 dia. x. width, (3. to 10. (3. to 84. R. ( R6 to 7 4.3 38 9 Roller lever can also be mounted on the opposite side. by lever rotational angle PT (pretravel for N.O. operation by dog operation LJK-N4F1 LJK-N4F1 LJK-N4F1 LJK-N74F1 0.N m ( (16 (7 (P 16 7 47 0.N m (8 (38 (7 41 0.N m (7 (7 R. ( ( 81.6 LJK-N4F1 8 47 (P 38 7 0 G 1/ 39.7 LJK-N74F1 7 41 (P 1-1 7 (P: Min. travel to positive opening position 0mm dia. resin roller lever: LJK-N39F1, LJK-N39F1, LJK-N739F1 3 Roller: 0 dia. x 10 width, 49. 4 0 Roller lever can also be mounted on the opposite side. by lever rotational angle PT (pretravel for N.O. operation LJK-N39F1 LJK-N39F1 LJK-N739F1 0.N m ( (16 (7 47 0.N m (8 (38 (7 41 0.N m (7 (7 (16 78 33 R. ( by dog operation (P LJK-N39F1 16 7 ( R. ( 81.6 LJK-N39F1 8 47 (P 38 7 0 G 1/ 37 LJK-N739F1 7 41 (P 1-1 7 (P: Min. travel to positive opening position 4

0mm dia. resin adjustable roller lever: LJK-N49F1, LJK-N49F1, LJK-N749F1 (unit: mm 3 Roller: 0 dia. x 10 width, Roller lever can also be mounted on the opposite side. 47.9 40.4 (60 to 100 ( R3 to 7 by dog operation R (78 to 8 (P LJK-N49F1 R 8. ( LJK-N49F1 0 LJK-N749F1 47 (P 7 38 41 (P 7 G 1/ 7 16 81.6 ( (. to 17. 6.9 LJK-N49F1 LJK-N49F1 LJK-N749F1 by lever rotational angle 47 41 0.N m 0.N m 0.N m ( (8 (7 (38 PT (pretravel for N.O. operation (16 (7 (7 (7-1 7 39.7 1 (P: Min. travel to positive opening position Plunger: LJK-N10F1, LJK-N10F1, LJK-N710F1 LJK-N10F1 LJK-N10F1 LJK-N710F1 by vertical operation N N N 4.mm 4.mm 4mm N N N (.mm (.8mm (.7mm (4.0mm PT (pretravel for N.O. operation (1.4mm ( ( ( Plunger: 8 dia. Steel by vertical operation 1.. 4.(P. ( LJK-N10F1 1.4 ( 0. R R (7.8 LJK-N10F1 ( 4.0.7 LJK-N710F1 0 G 1/ 4.(P -1 4(P 1 (P: Min. travel to positive opening position

Resin roller plunger: LJK-N0F1, LJK-N0F1, LJK-N70F1. R. LJK-N0F1 LJK-N0F1 LJK-N70F1 by vertical operation N N N 4.mm 4.mm 4mm N N N (.mm (.8mm (.7mm (4.0mm PT (pretravel for N.O. operation (1.4mm ( ( ( 1. Roller: dia. x 3. width, by vertical operation ( 4.(P. ( LJK-N0F1 8 (unit: mm R. ( 0 4.0 LJK-N70F1 4(P.7 G 1/ 4.(P.8 LJK-N0F1 1.4-1 1 (P: Min. travel to positive opening position Resin cross roller plunger: LJK-N03F1, LJK-N03F1, LJK-N703F1 LJK-N03F1 LJK-N03F1 LJK-N703F1 by vertical operation N N N 4.mm 4.mm 4mm N N N (.mm (.8mm (.7mm (4.0mm PT (pretravel for N.O. operation (1.4mm ( ( ( Roller: dia. x 3. width, 1. 4.(P. LJK-N03F1 ( R R LJK-N03F1 1.4.8 8. by vertical operation (. 4.(P 4.0 1 (.7 LJK-N703F1 0 G 1/ -1 4(P 6 (P: Min. travel to positive opening position

Resin one-way roller (horizontal: LJK-NF1, LJK-NF1, LJK-N7F1 (unit: mm 3 LJK-NF1 LJK-NF1 LJK-N7F1 by dog operation.9mm.9mm.6mm (9mm (10mm (9.6mm (mm PT (pretravel for N.O. operation (.mm Roller: dia. x. width,. R18 R ( LJK-NF1.9(P R ( (93.7 by dog operation 9 19 (39. 10 10 ( LJK-NF1 G 1/ LJK-N7F1.9(P mm 9.6.6(P 0.mm -1 1 (P: Min. travel to positive opening position Resin one-way roller (vertical: LJK-N7F1, LJK-N7F1, LJK-N77F1 3 LJK-N7F1 LJK-N7F1 LJK-N77F1 by dog operation.9mm.9mm.6mm (9mm (10mm (9.6mm (mm PT (pretravel for N.O. operation (.mm Roller: dia. x. width, 10 by dog operation 9 R. ( LJK-N7F1 ( (9. 19 (41 R18.mm 10 LJK-N7F1.9(P.9(P mm 1 R. ( 9.6.6(P LJK-N77F1 0 1 G 1/ (1. -1 7 (P: Min. travel to positive opening position

Steel wire: LJK-N06F1, LJK-N06F1, LJK-N706F1 (unit: mm Note: Steel wire switches do not have positive opening mechanism. LJK-N06F1 LJK-N06F1 LJK-N706F1 by wire inclination angle 0.N m 0.N m 0.N m ( (8 (7 (4 PT (pretravel for N.O. operation ( 196. 1. dia.. R ( by dog operation 1 R 69 ( LJK-N06F1 8. LJK-N06F1 ( 4 7 0 G 1/ LJK-N706F1-1 (P: Min. travel to positive opening position Spring rod: LJK-N08F1, LJK-N08F1, LJK-N708F1 Note: Steel wire switches do not have positive opening mechanism. LJK-N08F1 LJK-N08F1 LJK-N708F1 by rod inclination angle 0.N m 0.N m 0.N m ( (8 (7 (4 PT (pretravel for N.O. operation ( 18 6.4 dia. 18. LJK-N08F1 ( R by dog operation ( 69 R. 1 8 LJK-N08F1 4 ( 7 LJK-N708F1 0 1 G 1/ -1 8 (P: Min. travel to positive opening position

HANDLING PRECAUTIONS 1. Mounting the switch Always tighten each part of the safety switch to the tightening torque recommended in the product specifications. If any part is tightened excessively, the screw and/or other parts may be damaged. Mount the dog so that no force is directly applied to the actuator in the free state. Do not use any glue or lubricant containing silicone. Doing so might result in faulty electrical conductivity.. Wiring Do not perform wiring work with the power turned ON. Doing so might cause an electrical shock or cause the device to operate suddenly. 3. Adjustment Do not apply excessive force (force times larger that the O.F. to the actuator when it is beyond the operation limit position. Doing so might break the switch. Adjust the actuator motion so that it exceeds the specified P.O. (travel to positive opening position but does not exceed the operation limit position. 4. Operating environment Do not use in a location subject to splashing with strong acid or alkali. 1 9