Technical Information

Similar documents
Technical Information

Technical Information. 300 Elm Street Rockford, Illinois

Meeting Room Head Table/Dimensions/Capacities (Subject to Fire Marshal Approval) Seating Capacities

ACCESSIBILITY GUIDE REVISED

Oregon Conventi Center

AMERICA S CENTER. America s. Center

PIKE STREET PIKE STREET

THE NEW HENRY B. GONZÁLEZ CONVENTION CENTER

Washington State Convention Center Level One: Entrances, Shops, and Services FLOOR PLANS, CAPACITIES, AND DIMENSIONS PIKE STREET PIKE STREET

The Moscone Center Facility Accessibility Information

TECHNICAL INFORMATION. Rabobank Arena Capacities. End stage - 9,000. End stage ,225. Center stage - 10,225. Half-house - 6,400.

RBC THEATRE TECHNICAL INFORMATION

Event Center. Welcome to the Event Center at San Jose State University. This multi-million

Please contact Brisbane Powerhouse for further capacity and configuration break downs.

NORTH CHARLESTON COLISEUM

Anaheim. Anaheim Convention Center by the numbers

Welcome. 100,000 square feet of meeting space when combined with the Adler Theatre. Exclusive catering, decorating, and audio-visual services

General Specifications for Lighthouse Power Pedestal

The Grand Hall/Arena

A. This section includes unit capacitors for power factor correction.

A. This section includes enclosed dry type transformers for lighting and power loads, with primaries and secondaries rated 600 volts and less.

WINTRUST ARENA at MCCORMICK SQUARE 200 E. CERMAK RD, CHICAGO, ILLINOIS wintrustarena.com

Venue Specification. Concerts and Entertainments. Technical services supplied by: Harrogate International Centre Kings Road, Harrogate, HG1 5LA

LOEB PLAYHOUSE TECHICAL SPECIFICATIONS PRE SHOW SHIPPING ADDRESS LARGE FREIGHT AND DAY OF SHOW SHIPPING ADDRESS TECHNICAL SPECIFICATIONS

h y n e s r i g g i n g r u l e s a n d r e g u l a t i o n s G 1 4

COLORADO CONVENTION CENTER BELLCO THEATRE TECHNICAL SPECIFICATIONS REVISED AS OF 4/1/2016

Union Bank & Trust Pavilion 16 Crawford Circle Portsmouth, Virginia (fax)

Table Station Elements

TECHNICAL SPECS. PORTSMOUTH PAVILION 16 Crawford Circle Portsmouth, VA (Fax)

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual

RENTAL RATES

Loading Dock: Two covered truck berths with a 100 long interior holding and storage area that enters onto stage left.

Technical Packet Value City Arena at the Jerome Schottenstein Center

March Government Center Station

ADA Checklist RESTAURANTS AND CAFETERIAS

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

2209 S. Knoxville Russellville, AR (479)

Creating An Accessible World ELVORON CPL.

Elvoron Home Elevator

Elegance Electrician s Installation Guide

Rates, Services & Equipment Personnel Services, Technical Services, Facility Equipment, Cleaning Services, Re-Set Fees

La Caserne. 103 Dalhousie Québec (Québec) Canada, G1K 4B9. Telephone : (418) Fax : (418) Telephone : (418)

NTELOS Pavilion 901 Crawford Street Portsmouth, VA

Spring Test 10 due 05/11/2013

Technical Guidelines CARMEN WÜRTH FORUM

CECO BUILDING SYSTEMS

2701 INTERTECH DRIVE, YOUNGSTOWN, MAHONING COUNTY, INDUSTRIAL PROPERTY FOR SALE 143,789 SF on ACRES $4,300,000

East Allen County Schools Facilities History Calendar Years October 5, 2015

RAMP DOORS ACCESS DOORS

ELVORON HR DESIGN AND PLANNING GUIDE

The St. Augustine Amphitheatre 1340C A1A South, St. Augustine, Florida 32080

25' - 6" 4' - 0" 8' - 10" 4' - 0" opt. bath 4. opt. clo. 5' - 6" 17' - 0" opt. bed 4 11' - 6" 10' ceiling. flr. 3' - 5" 3050 sh.dl.

Shelter: Primary Shelter Secondary Shelter Respite Site Only Client Service Center Pet Shelter

Proposed Kitchen Plan Scale:1/2"=1'-0"

FACILITY EXPANDABLE TO 780,000 SF PROPERTY HIGHLIGHTS RESEARCH DR. (PARCEL 43B)

Anaheim Convention Center. Meeting & Exhibit Space

Lighting Inventory. (2) 120/208V; 3 phase 400 Amp with lug connections, stage left at mezzanine No Shore Power available

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

BADLANDS ENVIRONMENTAL CONSULTANTS, INC E. Central Ave. Bismarck, ND (701) AIR MONITORING & SAMPLE ANALYSIS REPORT

FOR SALE OR LEASE EBERHARDT & BARRY INC.

F9 PROPERTIES LUMBER LIQUIDATORS FACILITY 307,184 + /- Square Feet on /- acres Toano, Virginia

KLIK LEDpod 50 Patented

The St. Augustine Amphitheatre 1340C A1A South, St. Augustine, Florida 32080

Shipping and Receiving

Location: Fraser Fort George, Prince George, Northern BC - Municipal : Trail (Great Northern Circle Route)

(2) For mounting heights suitable in schools and other facilities used primarily by children see section

KLIK LEDpod 40 Patented

Home Elevator. Planning Guide

Product Overview. High Power 7W/ft. Fixture Summary (see following pages for more information) Power Level Watts Per Foot

Elvoron CPL. Planning Guide

Decidedly Jazz Danceworks Technical Specifications Updated: Jan 5, 2017

GP12 TECHNICAL MANUAL

ELVORON HOME ELEVATOR

All necessary forms are available in this section and are DUE FEBRUARY 9, 2018.

STANDARD 120V ELECTRICAL ORDER FORM

Temporary Sales Trailer Application

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

Electrical Depth. Josh Kreutzberger Lighting/Electrical

CECO BUILDING SYSTEMS

Section 02: Pre-Installation Procedures

Technical Packet Value City Arena at the Jerome Schottenstein Center

610 chartwell road OAKVILLE, ON

PRODUCT SPECIFICATIONS

Chapter 5. General Site and Building Elements

CODE ANALYSIS BUILDING AREA STORIES 2 BUILDING HEIGHT 25'

Meter Installation. -and- Padmount Transformer Guide

Orion LU/LA Commercial Elevator OWNER S MANUAL

Over-moldable Ruggedized Connectors for higher Amperage

2018/9 Capital Improvement Plan Building on our strong foundation

REAR +/- 94' 20' 10' 10'-4" 9'-6" 10'-3" 10' 20' 13'-2" Private Office 25. Private Office 23 Private Office 24 7'-1" Open Space 3 14'-7"

Smooth Silent Precise. The best sensation is not to notice anything. A dream lifestyle

CHAPTER 4: ACCESSIBLE ROUTES

Flat Screen Garage Table System Price List. November 6, 2006 Updated May 22,

ACCESSIBLE COMMUNITY BUILDER CHECKLIST

SECTION VII METERING INSTALLATIONS

Facility Technical Package. Bert Church Live Theatre Address 1000 East Lake Blvd NE, Airdrie, AB Canada. Bert Church. LIVE Theatre

James H. Whiting Auditorium (dba The Whiting)

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery

BARBARA B. MANN PAH Tech Information Table of Contents

Transcription:

Technical Information CCC Total Gross Square Footage: 2,200,000 square feet. Lower Level: 114,860 square feet Street Level: 313,525 square feet (Includes theatre) Upper Level: 625,969 square feet Elevations for Each Level: Lower Level: 5,197 6 Street Level: 5,214 Upper Level: 5,241 6 (It is 16 6 from the Lower Level floor to Street Level floor, 27 6 from Street Level floor to Exhibit Hall level floor, and 44 from Lower Level floor to Exhibit Level floor.) Freight Elevator: Located at Hall A load-in door. Freight elevator is 19 6 deep; 12'2" wide, 10' high; capacity 20,000 pounds. Elevator services to exhibit floor level, meeting room level and Four Seasons Ballroom level. Stout Sliding Door: Located in north shuttle drop off. Open door dimensions: 101 wide x 111 high. LOBBY AND BUS DROP OFF INFORMATION Lobby Square Footage: A: 13,000 square feet. B: 25,000 square feet. C: 12,000 square feet. D: 28,800 square feet. E: Minimal square feet. F: 13,500 square feet. Bellco Theatre: 12,500 square feet. West outside deck: 6,020 square feet. East outside deck: 1,000 square feet. 1

LOBBY AND BUS DROP OFF INFORMATION (continued) Note: A Entry from the tile to top of glass railing: 24 3. Lobby A & B: Ceiling height 16 @ soffit and 18 at the dropped ceiling grid. Lobby B & C entrance door clearance: 77 wide by 93 high. Lobby D,F& Bellco Theatre entrance door width clearance: 65 Freight Elevator to Lobby B, the distance between the column and the wall is 88 (narrowest point). Lowest point is 96 (roll door). Upper D Lobby Grid Dimensions (approx.): D Hall South: Right Side 120 Left Side: 280 Front 485 D Hall North: Right Side: 0 Left Side: 52 Front: 256 Lobby Utilities: Electric: Video: Telephone: Audio: 24-32 duplex 20 amp service outlets on floors and walls. 1, 60 amp, 208/120 volt wall receptacles and 1-20 amp, 208/120 volt wall receptacle. Coax cable service outlets on floors and walls. Multi-mode located in each lobby. Voice/data jacks along walls. Limited number of inputs available. Large Overhead Directional Signs: 3 101/2 high X 18 3 long. Bus Drop off: A Lobby drop off will accommodate 3 Busses. B Lobby drop off will accommodate 10 busses. D Lobby drop off will accommodate 3 busses F Lobby drop off will accommodate 4 busses. 2

LOBBY AND BUS DROP OFF INFORMATION (continued) Welton Drive Height Measurements (length of vehicle important plus labor to remove and re-install the way-finding sign): Ceiling height from 13th Street going east: 13 th Street and ring road = 14 8 1st column east (30 ) = 13 11 2 nd column east (60 ) = 13 7 3 rd column east (90 ) = 13 4 CONCOURSE INFORMATION Concourse Square Footage: A 25' x 219'; 5,475 square feet B 18' x 243'; 4,374 square feet C 25' x 203'; 5,075 square feet D 70 x 140 ; 9,800 square feet. E: 30 x 270 ; 8,100 square feet. F 40 x 200 ; 8,000 square feet. Grand Concourse: Length 949.5 from bottom of ramp to the Bellco Theatre. 3

EXHIBIT HALL INFORMATION Loading Dock and Exhibit Floor Move In: Halls A, B, & C: 23 truck positions available, width 12'6"; length 80', dock driveway width 26'; dock ceiling height 25'; Halls A & C load-in doors 22' wide, 20' high; Hall B outer door load in 21 11, 15 1 high; inner door load in 28 6, 15 1 high; Hall C outer door load in 21 11, 17 10 high; inner door load in 21 11, 17 10 high. Dock levelers at docks 3, 13, and 26. Loading ramp is length 500, width 32, and grade 10%. Welton Dock Side Ramp Angle = 5.31 degrees Champ Dock Side Ramp Angle = 2.90 degrees Welton Dock Access Door: 30 w x 17 h. Halls D, E, & F: 20 truck positions available, width 12, length 80, dock driveway width 29, dock ceiling height 24, Hall D has 2 load in doors 22 wide 16 high and 10 wide 12 high. Hall E has 2 load in doors 22 wide 16 high and 10 wide 12 high. Hall F has 2 load in doors 16 wide 16 high and 12 wide 12 high. Dock levelers at docks 28, 37 and 47. Champa Dock Access Door: 25 w x 17 10 h. Exhibit Hall Square Footage: A 105,000 architectural net square feet. B 90,000 architectural net square feet. C 95,000 architectural net square feet. D 92,000 architectural net square feet. E 91,000 architectural net square feet. F 106,000 architectural net square feet. A + B1 147,000 architectural net square feet. C + B2 143,000 architectural net square feet. D + E1 151,000 architectural net square feet. F + E2 137,000 architectural net square feet Note: Exhibit Halls A,B&C to Exhibit Halls D,E&F through the movable partition wall double doors. Door clearance: 64 wide 86 high. Exhibit Hall Upper Lobbies Square Footage: A 5,600 Square feet. C D F 4,800 Square feet. 16,000 Square feet. 10,200 Square feet. Note: Exhibit Hall to Upper Lobby door width clearance: Exhibits Hall A, B, &C: 75 1/2 Exhibits Hall D, E, &F: 65 4

EXHIBIT HALL INFORMATION (continued) Exhibit Hall Upper Lobbies Height of the Grid above the Hall Entries (Metal band grid width is 12 ): A B C 10 (round columns in the grid ceiling area). Grid Ceiling is 15 9 off of the floor. No grid 9 11 (round columns in the grid ceiling area) D North = 10 and South = 10 1 E No grid F North = 9 9 and South = 10 Exhibit Hall A,B&C Floor Utilities: Floor Ports: 30' centers. Electrical: 2 each, 20 amp 120 volt, duplex outlet, 1 each 100 amp, 208 volt, 3 phase service. Telephone: 1 each, 25 pair Amphenol connector Exhibit Halls A, B & C. 2 strand multi-mode each port Exhibit Halls. Water Drain: 1 each, 1-1/4" floor drain at each floor port. Exhibit Hall D, E & F Floor Utilities: Floor Ports: 30' centers. Electrical: Electrical panel in port: 18 20amp 120/208v. Electrical panel not in port: 1 100amp 120/208v 3 phase. Telephone: 2 Data and 6 pair CAT 6 4 strand multi-mode and 4-strand single-mode each port Water Drain: 1 each, 1-1/4" floor drain at each floor port. Exhibit Hall A,B&C Column Utilities: Columns: 90' Centers, except center of Hall A. Electrical: 4 each dedicated 20 amp, 120-volt duplex outlets. 1 each, 100 amp 120/208 volt 3-phase 5 wire service. 1 each, 60 amp 277/480 volt 3-phase 5 wire service. Water: 4 each, hose bib, faucet #293, 45-psi minimum. Compressed Air: 4 each, AMFLO C5 coupler, 80 psi. Telephone: 1 each 25 pair Amphenol connector at each column. 2 strand multi-mode at each column. Cable TV: CATV multiple overhead locations. Audio: Limited number of microphone inputs available at interior columns. Exhibit Halls A, B, & C North-Side Emergency Exit Stairwell Enclosures: Hall A: One location only with a 4 high brick wall. Hall B: Two locations with two heights, 9 4 and 30. 5

Hall C: One location with a 4 high brick wall. EXHIBIT HALL INFORMATION (continued) Exhibit Hall D,E&F Column Utilities: Columns: 90' Centers. Electrical: 4 each dedicated 20 amp, 120-volt duplex outlets. 1 each, 100 amp, 120/208 volt, 3-phase 5 wire service. 1 each, 100 amp, 277/480 volt, 3-phase 5 wire service. Water: 4 each, hose bib, faucet #293, 45-psi minimum. Compressed Air: 4 each, AMFLO C5 coupler, 80 psi Telephone: 2 Data and 6 pair CAT 6 at each column Exhibit Halls. 4 strand multi-mode and 4-stand single-mode at each column Audio: Limited number of microphone inputs available at interior columns. Exhibit Hall Other Utilities: Natural Gas: 1 each in halls A, B & C, tie in by special arrangement only. Stage Electrical Supply: Exhibit Hall A & F only 2-400 and 2-200 amp, 208/120 volt 3 phase electrical service at columns A31 & F31. Overhead Electrical Bus Duct System: 800 amp, 208/120 volt, 3 phase in Exhibit Halls A&B, with an additional 600 amp, 208/120 volt, 3 phase in Hall C. Exhibit Halls D, E&F separate 1200 amp for each hall. Exhibit Hall Floor Load: 350 pounds per square foot. Exhibit Hall General Lighting: Lights in Exhibit Halls ABCDEF at 100% are 70 footcandles at 30 inches above the floor. (There is individual lighting control at an applicable hourly fee.) Hall A is the only exhibit hall that has dimmable LED lighting: Lights in Hall A at 100% + LED lights at 100% are 100 foot-candles at 30 inches above the floor. Lights in Hall A with ONLY LED lights at 100% are 35 footcandles at 30 inches above the floor. (Individual fixture control in Hall A is available at an applicable hourly fee.) Exhibit Hall Rigging: Refer to separate handout. Exhibit Hall Mezzanine Window-to-Doorway: A and C 6 8 between bottom of window to top of doorway. (Exhibit hall side For sign hanging purposes) B 8 0 6

BELLCO THEATRE INFORMATION Bellco Theatre Loading Dock Move In (Docks D, E): Two truck positions available to service the Bellco Theatre. Width 12 length 80 height clearance 14 6, 1 dock leveler. Dock driveway width 18. Dock access door 18 wide 16 high. Theatre load in door 8 wide 10 high. Stage access door 16 wide 12 high. Vehicle Access from Loading Dock to Bellco Theatre Stage: The route is up the ramp through the scene dock onto the stage. A path must be cleared by Technical Services for ease of move in and move out of the vehicle. This space was designed to bring in a Ford Expedition or other vehicle basically under the following parameters: 19 long, 7 wide. Green Room, Dressing Rooms & Multi-Purpose Rooms Ceiling Heights Green Room & Dressing Rooms 1-3: 9 Multi-Purpose Rooms 1-4: 17 3 Bellco Theatre Approximate Square Footage: 39,628 GO GOURMET CAFE LOBBY B Window Openings from Lobby B into the Café (with the curve, the windows get a little larger on the curved ends): Large Windows: 86 to 86-1/2 wide x 63 high Smaller Windows (above the larger windows): 86 to 86-1/2 wide x 35 high 7

MILE HIGH BALLROOM INFORMATION Mile High 1-4 Square Footage: All: 180 x 265 : 47,700 square feet. 1 or 4 60 x 180 : 10,800 square feet. 1 A,B,C,D,E or F 30 x 60 : 1,800 square feet. 2 A,B,C or 3A,B,C 45 x 180 : 8,100 square feet. 4 A,B,C,D,E or F 30 x 60 : 1,800 square feet. Prefunction Area: Prefunction Stairs: West Side East Side Circular Staircase 80 x 240 : 14,000 square feet. Height of the lower ceiling area: 12 106 wide w/28 steps, includes middle landing, the landing is 78 deep. 279 wide w/28 steps, includes middle landing, the landing is 51 deep. First landing is 13 8 diameter; second landing is 17 6 diameter Ballroom to Prefunction door clearance: 62 ½ wide. Entrance doors to ballroom: 61 ½ x 90 ½ Airwall entry/double doors: 64 wide. Service Corridor to West Prefunction: 91 wide x 95 high. Movable partition wall double entry doors: 64 Mile High Ballroom Digital Display Monitors: There are six built-in 32 monitor outside each of the main ballroom entrances. The meeting name has a maximum of 22 characters. The description of the event has a maximum of 17 lines, with approximately 44 characters per line with an approximate 450 characters total. Mile High 1-4 Move In Loading Docks (Docks A, B): Two truck positions available to service Mile High 1-4. Note: these docks are also used for food service deliveries. 1 position: width 13, length 70, height clearance 14 6 1 dock leveler. 1 position: width 11, length 40, height clearance 14 6 Dock driveway width 18. Dock access door 18 wide, 16 high. Load in door to building 10 wide 10 high. Load in door to Ballroom 12 wide 9 4 high. Vehicle Access from Loading Dock to Mile High 1 Load In Door: The Mile High 1 Load-In Door @ Mile High Ballroom 1D is 240 from the end of the docking bay. The route is up the ramp and along the top of the dock through the roll door at the north end of the dock. Then, through the Mile High 1 load in door. A path must be cleared by Centerplate Catering for ease of move in and move out of the vehicle. This space was designed to bring in a Ford Expedition or other vehicle basically under the following parameters: 19 long, 7 wide. 8

MILE HIGH BALLROOM INFORMATION (continued) Mile High 1, 2, 3 & 4 Utilities: Floor Ports: Four, flush-floor receptacles with 1 each, 60 amp, 120/208 volt, 3-phase electrical service receptacle; 1 each, telephone jack; 1 each, lighting control jack; 3 each, microphone-level audio input; 1 each, line-level audio input. Floor Outlets: Dedicated 20 amp, 120-volt duplex receptacles on 30' centers. Major Electrical: Ballroom 2-3 location on north wall and Ballroom 1 west wall wall-cam lock style female connectors. 1-100 amp 3 phase, 120/208v 5 wire isolated service. 2-200-amp 3-phase 120/208v 5-wire service. 1-400 amp 3-phase 120/208v 5-wire service. East wall: 1-100 amp 3 phase, 120/208v 5 wire isolated service. 2-200-amp 3-phase 120/208v 5-wire service. 1-400 amp 3-phase, 120/208v 5-wire service. Both are fed from the same 800-amp service. Telephone: Ballroom Lighting: Ballroom Wall Audio: Ballroom Floor Load: Voice/data jacks along walls. General: Fluorescent 65 foot-candles, dimmable incandescent 25 foot-candles. Presentational: 1k par cans locate on light pipes over normal stage and head table set-up locations. White light, operational from house dimmers and house nondim circuits. The lighting control is Lutron based; there is not any DMX access for control. Atmospheric: Starlights are available with programmable movement and color choice via house control or through DMX protocol in any conventional lighting console. 6 microphones and 1 line-level in each of the three rooms. Multi-mode located throughout All Ballrooms floor load 100 psf. 9

FOUR SEASONS BALLROOM INFORMATION Four Seasons 1-4 Square Footage: All: Ballroom 1 (1/3): Ballroom 2-3 (1/3): Ballroom 4 (1/3): Ballroom 1-2 (1/2): Ballroom 3-4 (1/2): Ballroom Prefunction Space: 146' x 235'; 34,456 square feet 73' x 146'; 10,658 square feet 90' x 146'; 13,140 square feet 73' x 146'; 10,658 square feet 118' x 146'; 17,228 square feet 118' x 146'; 17,228 square feet 74' x 176'; 12,580 square feet Ballroom to Prefunction door width clearance: 73 Entrance doors to ballroom: 59 ½ x 90 ½ Service Corridor to Prefunction: 67 Four Seasons Digital Display Monitors: Built-in 32 monitors outside each ballroom. Content for the monitors is provided by the client in a tailor designed Excel spreadsheet. The meeting name has a maximum of 22 characters. The description of the event has a maximum of 17 lines, with approximately 44 characters per line with an approximate 450 characters total. There is an additional 75 monitor outside Four Seasons Ballrooms 2-3 that will display the content as shown on the other 32 monitors outside the rooms. In absence of specific usage content, the 75 monitor will play a video of CCC pictures. Four Seasons Prefunction: Columns: Height from the floor to silver rings 24 7, silver ring 16, and distance from silver ring to cone 9. Total height from floor to cone 26 8. Four Seasons 1,2,3 & 4 Load In: 2 dock spaces are available (17 & 18) at Exhibit Hall level with a freight elevator to access the Ballroom level. Freight elevator is 12 wide, 20 deep and 10 high 20,000 lb load capacity. Load in door to ballroom four is 9 X 9. 1 dock (F) is available at the Lower level. Ramp is 81 wide and the dock is 11 2 wide. 10

FOUR SEASONS BALLROOM INFORMATION (continued) Four Seasons 1,2,3, & 4 Utilities: Floor Ports: Four, flush-floor receptacles with 1 each, 60 amp, 120/208 volt, 3-phase electrical service receptacle; 1 each, telephone jack; 1 each, lighting control jack; 3 each, microphone-level audio input; 1 each, line-level audio input. Floor Outlets: Dedicated 20 amp, 120-volt duplex receptacles on 30' centers. Major Electrical: Telephone: Ballroom Lighting: Ballroom Wall Audio: Ballroom Floor Load: Ballrooms 2-3 location on north wall wall-cam lock style female connectors. 1-100 amp 3 phase, 120/208v 5 wire isolated service. 2-200-amp 3-phase 120/208v 5-wire service. 1-400 amp 3-phase 120/208v 5-wire service. East wall: 1-100 amp 3 phase, 120/208v 5 wire isolated service. 2-200-amp 3-phase 120/208v 5-wire service. 1-400 amp 3-phase, 120/208v 5-wire service. Both are fed from the same 800-amp service. Voice/data jacks along walls. General: Fluorescent 65 foot-candles, dimmable incandescent 25 foot-candles. Presentational: 1k par cans locate on light pipes over normal stage and head table set-up locations. White light, operational from house dimmers and house nondim circuits. The lighting control is Lutron based; there is not any DMX access for control. 6 microphone and 1 line-level in each of the three rooms. Multi-mode located throughout the ballroom. All Ballrooms floor load 100 psf. 11

MEETING ROOM INFORMATION Meeting Room Corridor Square Footage: 100: 21' x 231': 4,851 square feet 200: 21' x 214': 4,494 square feet 300: 18 x 140 : 2,520 square feet 400: 18 x 240 : 4,320 square feet 500: 18 x 226: 4,068 square feet 600: 21' x 203': 4,263 square feet 700: 21' x 203': 4,263 square feet Meeting Room Window Panels with Blackout Curtains (300/400/500 rooms only): Each meeting room has a total of 6 panels: Top 4 panels are 32-1/2 x 46 and the bottom 2 panels are 32-1/2 x 36-3/4. Meeting Room Door Dimensions: Meeting Room doors are 93 tall or 7 9, when the door closer is removed for additional clearance. 100/200/600/700 meeting room doors: 59 ½ x 90 ½. 300/400/500 meeting room doors: 61 ½ x 90 ½. Meeting Room Utilities: Electrical: Audio: Video: Telephone: 1, 60 amp, 208/120-volt receptacle per room and standard 120-volt wall receptacles. 3 each, mic-level inputs, 1 each, line-level input. Coax cable service outlets located next to audio input. Multi-mode throughout meeting rooms and registration areas. Voice/data jacks along walls. Meeting Room Lighting: At each meeting room wall panel, there is a four-scene, preset lighting inclusive of track lighting for head table location (with the exception of the 200 and 600 even-numbered meeting rooms). Meeting Room Digital Display Monitors: Built-in 32 monitors outside each meeting room. The meeting name has a maximum of 22 characters. The description of the event has a maximum of 17 lines, with approximately 44 characters per line with an approximate 450 characters total. Revised: 10/11/17-dcw 12