HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

Similar documents
HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key.

Door Interlock Switches

HS1E Series Full Size Solenoid Locking Switches

Door Interlock Switches

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality

HS6B Series Subminiature Interlock Switch

HS1E Series Full Size Interlock Switch with Locking Solenoid

HS6B Series Sub-Miniature Interlock Switch. Direct Opening

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

Door Interlock Switches

HS5E Series Miniature Solenoid Locking Switches

HS6E - L 4 4 B 01 - G

HS1C Interlock Switches with Solenoid

Solenoid Locking Safety Switches

HS1L Interlock Switches with Solenoid

HS6E Subminiature Interlock Switches with Solenoid. Double Installation. Part Number. Cable Length (+) ( ) A2 A1

HS5D Miniature Interlock Switches

HS1C-P Interlock Plug Unit with Door Lock

HS5D Miniature Interlock Switches

HS1E-K Interlock Switches with Solenoid (3-circuit)

Solenoid Locking Safety Switches

Door Interlock Switches

HS1L Interlock Switches with Solenoid

HS1L Interlock Switches with Solenoid

Interlock Switches. Safety. Selection Guide HS6B Subminiature HS5D Miniature HS2B Full Size...

Standard Interlock Safety Switches

HS1E Interlock Swithes with Solenoid

Head Removal Detection Function for Safer Performance

Section. Safety Products Selection Guide...B-2

Door Interlock Switches

Standard Interlock Safety Switches

HS5E Miniature Interlock Switches with Solenoid

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

SG-B1 SERIES / SG-A1 SERIES

HS5E Miniature Interlock Switches with Solenoid

HS5E Miniature Interlock Switches with Solenoid

HS6E Subminiture Interlock Switches with Solenoid

HS6B HS6E. Angled connection. cable. Compact with three poles of contacts. (HS6B) Small interlock switch with five poles and solenoid.

ct O en n Tr ve Solenoid Indicator (1) TÜV rating AC V, 3A 3 Mounting Examples

HS6B Subminiature Interlock Switches

NO NO NO. Standard Interlock Safety Switches HS6B. HS5E-K Key Locking Safety Interlock Switches

Safety device new products line up. Introducing a safety door switch with solenoid interlock that is among the world s thinnest*

Hinged Safety Door Switch

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

2 Specifications and Ratings. Applicable Standards. Operating Condition. Thermal Current Ith 10A Contact Ratings. Operating Speed

Interlock Switches Interlock Plugs

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Safety Limit Switch

Miniature Switches & Pilot Devices

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

HL (AZH) Limit Switches

HL (AZH) LIMIT SWITCHES

XW Series E-Stops. Safety. Selection Guide ø22mm XW E-Stops

PRODUCT SPECIFICATION. Stack Lights. Series.

Safety-door Switch. Ordering Information

Manual Reset Limit Switch

Door Handle Gate System

Think Automation and beyond... IDEC Safety Interlock Switches

Signaling Lights LD6A. LD6A LED SignaLight Towers Assembled Products. Unique Striped Design Improves Visibility

22mm XW E-Stops. UL File #E68961 CCC No Specifications

HS7A-DMC Non-contact Interlock Switches

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

DL (AZD1) Mini Limit Switches

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

Oiltight Switches & Pilot Devices

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K

HL (AZH) Limit Switches

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Switches & Pilot Devices

D4DL. Guard Lock Safety-door Switch. Model Number Structure

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

Enabling Switches. Safety. Selection Guide

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

Door Handle Gate System

D4BS CSM_D4BS_DS_E_8_4

22mm XW E-Stops. IEC , EN , JIS C , UL508, UL991, NFPA79, CSA C22.2 No. 14, GB

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

XW Series E-Stops. Safety. ø22mm XW E-Stops Phone: Fax: Web: -

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

Safety switches with separate actuator

D4GS-N CSM_D4GS-N_DS_E_7_2

LR-LX-LK-LW Safety Switches with separate actuator

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

D4JL/D4JL-SK40 CSM_D4JL_D4JL-SK40_DS_E_10_2

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening

SFS-UFS Single Foot Switches

Safety Control HR1S-AC. Safety Relay HR1S-AC

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

VL (AZ8) Limit Switches

XA Series Emergency Stop Switches (w/removable Contact Block)

VL (AZ8) Mini Limit Switches

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

PRODUCT SPECIFICATION. Foot Switches. Series.

D4BL. Guard Lock Safety-door Switch

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

Transcription:

HSB Series HSB Series Full Size Interlock Switch HSB features: Body Rugged aluminum die-cast housing Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded or stuck Available with or without an indicator (red or green) Flexible Installation: Two actuator entries and three conduit ports are provided Select from two circuit confi gurations (NO-NC or NC). Degree of Contact Protection: IP67 Model HSB (alum. die-cast housing) EN088 EN6097-5- IEC6097-5- Contact Configuration NC-NO NC Pilot Light GS-ET-5 BG standard in Germany Part Numbers Part Number WithoutHSB-R With red LED With green LED HSB-R-R HSB-R-G WithoutHSB-0R With red LED With green LED. The special key wrench (HS9Z-T) for removing the cover and manual unlocking is included with the switch.. Order the actuators separately (not supplied with the switch). Keys and Accessories Appearance Part Number Description HS9Z-A HS9Z-A HS9Z-A3 HS9Z-T HS9Z-P *Torx is a registered trademark of Camcar Textron. Straight (Mainly for sliding doors) Right-angle (Mainly for rotating doors) Adjustable Key Wrench (included with switch) Conduit Opening Plug HSB-0R-R HSB-0R-G Direct Opening Action Part Number Key HSB - 0 R - R Housing Color R (Red) Indicator Color R (Red), G (Green) Indicator Rated Voltage (V DC) Blank (without indicator) Configuration : NO-NC 0: NC Not necessary to specify color if indicator option not chosen. Overview X Series E-Stops Enabling Switches Barriers AS-Interface Safety at Work USA: 800-6-IDEC Canada: 888-37-IDEC 36

HSB Series Enabling Switches X Series E-Stops Overview Specifications Conforming to Standards IEC6097-5-, EN6097-5-, GS-ET-5, UL508 Operating Temperature 5 to +70 C (no freezing) Storage Temperature to +80 C Operating Humidity 85% RH maximum (no condensation) Altitude,000m maximum Rated Insulation Voltage (Ui) 300V (between LED and ground: 60V) Impulse Withstand Voltage (Uimp) kv (between LED and ground:.5 kv) Insulation Resistance Electric Shock Protection Class Pollution Degree Degree of Protection Between live and dead metal parts: 00 MΩ minimum Between live metal part and ground: 00 MΩ minimum Between live metal parts: 00 MΩ minimum Between terminals of the same pole: 00 MΩ minimum Class I (IEC6) 3 (IEC6097-5-) IP67 (IEC6059) Vibration Operating Extremes 0 to 55 Hz, amplitude 0.5mm p-p Resistance Damage Limits 60 m/sec (approx. 6G) Shock Resistance,000 m/sec (approx. 00G) Operating Speed m/sec maximum Positive Opening Travel mm minimum Positive Opening Force 0N minimum Thermal Current (Ith) 0A Rated Operating Current (Ie) Operating Voltage (Ue) 30V 5V 50V AC DC Resistive load (AC) Inductive load (AC5) Resistive load (DC) Inductive load (DC3) 0A 0A 8A A 0A 5A.A.A Operating Frequency 900 operations/hour Mechanical Life,000,000 operations Electrical Life 00,000 operations (rated load) Conditional Short-circuit Current 00A (IEC6097-5-) Recommended Short Protection 50V, 0A fuse (Type D0 based on IEC6069-, 6069-) Indicator Weight Operating Voltage Current Light Source Lens Color V DC 0 ma LED lamp Red or Green ( mm dia. Lens) Approx. 80g 6A 3A.A 0.6A AS-Interface Safety at Work Barriers 36 www.idec.com

HSB Series HSB Door/ Switch Status Door Application Examples and Diagrams HSB- (NO-NC) Diagram Main Aux. HSB-0 (NC) Diagram Main Aux. Status Status Door Closed Machine ready to operate + - 3 Main Auxiliary Door opened Machine cannot be started 3-: Closed 3-: Open -: Open -: Closed + - 3 Main Auxiliary 3-: Closed 3-: Open -: Closed -: Open. Main : used to enable the machine to start only when the main circuit is closed. Auxiliary : used to indicate whether the main circuit or door is open or closed.. Terminals + and - are used for the LED indicator, and are isolated from door status. Wire the terminals only when needed. + - + - 3 3 Main Auxiliary Main Auxiliary Overview X Series E-Stops Enabling Switches Barriers AS-Interface Safety at Work USA: 800-6-IDEC Canada: 888-37-IDEC 363

HSB Series Overview HSB - using the straight actuator (HS9Z-A) (Horizontal Mounting) 30 9 RP 68.8 36.5 3.8 0 R.7 ø5. Conduit Port G/ Dimensions (mm) HSB - using the Right-angle actuator (HS9Z-A) (Horizontal Mounting) RP 30 6 36.5 6 0 R.7 ø5. Conduit Port G/ 5 6 Cover 9.5 5 ±.0 3 Cover ±.0 X Series E-Stops Slot Plug (Note) (Vertical Mounting) RP 5.3 30 3.8 9 6.5.5 5 9.5 36.5 0 R.7 ø5. 5 35 Conduit Port G/ Conduit Port G/ 3 5 6 5 6 9.5 5 7.5 3 Slot Plug (Note) (Vertical Mounting) 6.5 6 RP 30.5 9.5 R.7 5 36.5 0 ø5. 3 5 5 6 35 Cover -M5 Screws.5 8.5 ±.0 5 35 Cover -M5 Screws.5 9.5 ±.0 5 35 Plug the unused actuator insertion slot using the slot plug supplied with the interlock switch. Enabling Switches Straight HS9Z-A -M6 Screws R3. 9 9.3 9.3 Dimensions Right-angle HS9Z-A -M6 Screws 0.5 7..5 Angle-adjustable HS9Z-A3 (Note) Stop Film (attached) 8 9. 3 Barriers 9. 3 9. Mounting Holes 7. Cover (red). Mounting Holes R3. 90 Cover (red). 5 0 R3. Door hinge 33 max. () 58 7 58 Angle Adjustment Screw (M3 hexagon socket head screw) -M6 Screws Mounting Holes 30 0 AS-Interface Safety at Work Adjustable The actuator angle is adjustable (0 to 0 ) for hinged doors. The minimum radius of the door opening can be as small as 00mm. Angle Adjustment Using the screw (M3 hex socket head screw), the actuator angle can be adjusted (refer to the dimensional drawing). Adjustable angle: (0 ) to 0 The larger the adjusted angle of the actuator, the smaller the applicable radius of the door opening. After installing the actuator, open the door. Then adjust the actuator so that its edge can be inserted properly into the entry slot of the safety switch. Recommended tightening torque: 0.8 N-m (approx. 8.0 kgf-cm) After adjusting the actuator angle, apply loctite or the like to the adjustment screw to prevent it from loosening. 36 www.idec.com

Precautions Safety Precautions In order to avoid electric shock or a fi re, turn the power off before installation, removal, wire connection, maintenance, or inspection of the switch. If relays are used in the circuit between the safety switch and the load, consider degrees of the danger and use safety relays, since welded or sticking contacts of standard relays may invalidate the functions of the safety switch. Regardless of door types, do not use the safety switch as a door stop. Install a mechanical door stop at the end of the door to protect the safety switch against excessive force. Do not apply excessive shock to the switch when opening or closing the door. A shock to the door exceeding,000 m/sec (approx. 00G) may cause the contacts of the switch to chatter, and a malfunction of the switch may occur. For connection of wires, unscrew the cover. Unnecessary loosening of other screws may cause a malfunction of the switch. For Rotating Head Directions The heads of the HS5E/HS5B can be rotated in 90 increments after removing the screws on the corners of the head. Prevent entry of foreign objects into the switch during removal of the head. Tighten these screws with torque designated in the instruction sheet. Improper torque may cause errors. Factory Setting Head can be rotated. of Hinged Doors When using the interlock switch on hinged doors, refer to the minimum radius of doors shown below. When using on doors with small minimum radius, use the angle adjustable actuator (HS9Z-A55). Wire Connection The HSB has 3 conduit ports, which are closed as a part of the molded switch housing. Make an opening for wire connection by breaking one of the conduit-port knockouts on the switch housing using a screwdriver. When breaking the conduit port, take care not to damage the contact block or other parts inside the switch. Operation Precautions - for all series HS5E/HS5B Precautions Do not place a PLC in the circuit between the safety switch and the load. The safety security can be endangered in the event of a malfunction of the PLC. Do not disassemble or modify the switch. It may cause a breakdown or an accident. Prevent foreign objects such as dust and liquids from entering the switch while connecting conduit or wiring. If the operating atmosphere is contaminated, use a protective cover to prevent the entry of foreign objects into the switch through the actuator entry slots. Entry of a considerable amount of foreign objects into the switch may affect the mechanism of the switch and cause a breakdown. Do not store the switches in a dusty, humid, or organic-gas atmosphere. Note: Because deviation or dislocation of hinged doors may occur in actual applications, make sure of the correct operation before installation. When using the HS9Z-A5 When the door hinge is on the extension line of the interlock switch surface: 70 mm 90 mm When door hinge is on the extension line of the actuator mounting surface: 30 mm HSB Precautions 60 mm Cracks or burrs on the conduit entry may deteriorate the housing protection against water. When changing to another conduit port, close the unused opening with an optional plug (Part No. HS9Z-P). Overview X Series E-Stops Enabling Switches Barriers AS-Interface Safety at Work USA: 800-6-IDEC Canada: 888-37-IDEC 397

Precautions HSE Precautions Overview Wire Connection Make an opening for wire connection by breaking one of the conduit-port knockouts on the switch housing using a screwdriver. Before breaking the knockout, temporarily remove the connector-fi xing lock nut from the switch.. This unlocking method is intended for an escape from a machine when a person is locked in. For access to the unlocking entry, an access hole should be opened on the mounting panel. When opening the hole, apply proper protection against water or other foreign objects.. Caution: After the unlocking operation, put the screw back into the unlocking entry for safety. When breaking the knockout, take care not to damage the contact block or other parts inside the switch. Cracks or burrs on the conduit entry may deteriorate the housing protection. X Series E-Stops When changing to the other conduit port, close the unused opening with an optional plug (accessory). Plug Type No. HS9Z-P Screwdriver Unlock Normal Position Unlock Manual Unlocking Position Manual Unlocking Remove the screw located on the unlocking entry at the side of the switch using the key wrench included with the switch. Then insert a small screwdriver into the switch to push the lever inside of the switch toward the indicator until the actuator is unlocked (refer to the diagram on the right). Insert a small screwdriver into the elliptical hole on the back of the switch, then push the lever inside of the switch toward the indicator until the actuator is unlocked (refer to the diagram on the right). M5 3.5 6 89 Enabling Switches Regardless of door type, do not use the safety switch as a locking device. Install a locking device independently, for example, using a metal latch (also applicable to HSE). The safety switch cover can be only removed with the special key wrench supplied with the switch or with the optional screwdriver (also applicable to HSB and HSE). Barriers AS-Interface Safety at Work HSC Precautions Remove the screw located on the unlocking entry at the side of the switch using the key wrench included with the switch. Then insert a small screwdriver into the switch to push the lever inside of the switch toward the indicator until the actuator is unlocked (refer to the diagram on the right). Caution: After the unlocking operation, put the screw back into the unlocking entry for safety. Screwdriver 398 www.idec.com

Precautions Operation Precautions Applicable Crimping Terminals Applicable Connectors (As shown below) (Refer to the Crimping Terminal or shown in the drawing below.) HSC Terminals No. to 6: Use solid or stranded wires only (crimping terminals not applicable). Terminals No. 7 and 8: Crimping Terminal Ground Terminal: Crimping Terminal HSB Ground Terminal: Crimping Terminal Other Terminals: Crimping Terminal HSB, HS5B, and HSE Crimping Terminal 3.6 min. 3.5 max. ø3.6 min. 6.9 max. Crimping Terminal Use an insulation tube on the crimping terminal. Wire Approx. mm Insulation Tube 3.5 min. 3.8 max. ø. min. 7.6 max. Crimping Terminal Crimping Terminal Installation Examples (see the diagrams below) Mounting on Sliding Doors Door HS9Z-A Door Stop Mounting on Hinged Doors HS9Z-A Latch HS9Z-A Use connectors which maintain the IP67 protection. Applicable Connector Dimensions Flex Conduit: VF03 (Japan Flex) www.nipolex.co.jp Steel Connector (G/): ALC-03 (PF3.5): RBC-03PG3.5 9 mm max. G/ Recommended Screw Tightening Torque HSC: 5.0±0.5 N-m (approx. 50±5 kgf-cm) ( or 6 pcs of M5 hex socket head cap screws) HSB: 5.0±0.5 N-m (approx. 50±5 kgf-cm) ( or pcs. of M5 hex socket head cap screws) HSB: 5.0±0.5 N-m (approx. 50±5 kgf-cm) ( pcs of M5 hex socket head cap screws) HS5B:.0±0. N-m (approx. ± kgf-cm) ( pcs of M hex socket head cap screws) HSE: 5.0±0.5 N-m (approx. 50±5 kgf-cm) ( or 6 pcs of M5 hex socket head cap screws) (HS9Z-A/A) 5.0±0.5 N-m (approx. 50±5 kgf cm) ( pcs. of M6 hex socket head cap screws) (HS9Z-A5/A5).0±0. N-m (approx. 0± kgf cm) ( pcs of M hex socket head cap screws).0±0. N-m (approx. 0± kgf cm) ( pcs of M Phillips screws) The screws are supplied by the user. Applicable Wire Size 30 mm max. HSC: 0.5 to 0.75 mm (Terminals No.,, 5 to 8).0 to.5 mm (Terminals No.3,, and grounding terminal) HS5B: 0.5 to.5 mm HSE: 0.5 to.5 mm Overview X Series E-Stops Enabling Switches Barriers AS-Interface Safety at Work USA: 800-6-IDEC Canada: 888-37-IDEC 399

Precautions Overview Angle Adjustment Using the screw (M3 hex socket head screw), the actuator angle can be adjusted (refer to the dimensional drawing). Adjustable angle: (0 ) to 0 The larger the adjusted angle of the actuator, the smaller the applicable radius of the door opening. After installing the actuator, open the door. Then adjust the actuator so that its edge can be inserted properly into the entry slot of the safety switch. Recommended tightening torque: 0.8 N-m (approx. 8.0 kgf-cm) After adjusting the actuator angle, apply loctite or the like to the adjustment screw so as to prevent its loosening. X Series E-Stops of Hinged Door When using the interlock switch on hinged doors, refer to the minimum radius of doors shown below. When using on doors with small minimum radius, use the angle adjustable actuator (HS9Z-A55). Note: Because deviation or dislocation of hinged doors may occur in actual applications, make sure of the correct operation before installation. When using the HS9Z-A5 When the door hinge is on the extension line of the interlock switch surface: Horizontal Swing 50 mm Vertical Swing 70 mm 90 mm Enabling Switches 70 mm When door hinge is on the extension line of the actuator mounting surface: 30 mm 60 mm When using the HS9Z-A55 Angle Adjustable When door hinge is on the extension line of the interlock switch surface: 50 mm When door hinge is on the extension line of the actuator mounting surface: 70 mm 50 mm 70 mm Angle Adjustment for the HS9Z-A55 Using the angle adjustment screw, the actuator angle can be adjusted (see fi gures on page 370. Adjustable angle: 0 to 0 The larger the adjusted angle of the actuator, the smaller the applicable radius of the door opening. After installing the actuator, open the door. Then adjust the actuator so that its edge can be inserted properly into the actuator entry slot of the interlock switch. After adjusting the actuator angle, apply Loctite to the adjustment screw so that the screw will not loosen. Barriers AS-Interface Safety at Work Use a cable gland with a degree of protection IP67 G/, PG3.5, M0 9 max. When Using Flexible Conduits (Example) Flexible conduit example: VF-03 (Nihon Flex) 30 max. Applicable Cable Glands When Using Multi-core Cables (Example) all dimensions in mm Conduit Port Size Plastic Cable Gland Metal Cable Gland G/ RLC-03 (Nihon Flex) PG3.5 RBC-03PG3.5 (Nihon Flex) M0 RLC-03EC0 (Nihon Flex) Conduit Port Size Plastic Cable Gland Metal Cable Gland G/ SCS-0* (Seiwa Electric) PG3.5 ST3.5 (K-MECS) M0 ST-M0X.5 (K-MECS) ALS-6** (Nihon Flex) ABS-**PG3.5 (Nihon Flex) ALS-**EC0 (Nihon Flex) Different cable glands are used depending on the cable sheath outside diameter. When purchasing a cable gland, confirm that the cable gland is applicable to the cable sheath outside diameter. When using a /-NPT cable gland, use the HS5B interlock switch with M0 conduit port (Part No.: HS5B-***BM) together with an adapter (Part No.: MA-M/NPT 0X.5 5-00, K-MECS) and a gasket (Part No.: GP M0, K-MECS). Install a gasket between the interlock switch and the adapter. Apply sealing tape between the cable gland and the adapter to make sure of IP67 protection for the enclosure. 0 www.idec.com