Molded Case Selection Guide Replacement s for Eaton Panelboards
Molded Case Selection Guide Product Range in Stock and Ready to Go Range KAIC @ 240Vac KAIC @ 277Vac KAIC @ 347Vac KAIC @ 600Vac Terminals 15A to 225A ED 2-P 200A 65 Load side ED 3-P A to 225A 65 Load side EHD 1-P 15A to 60A 14 Load side EHD 2-P 15A to A 18 Load side EHD 3-P 15A to A 18 Load side FD 1-P 15A to 40A 35 Load side FD 2-P 15A to A FD 3-P 15A to 225A Therm/Mag Non-Interchangeable Trip 65 65 18 18 Load side Load side FDB 1-P 15A to 40A 14 Load side FDB 2-P 15A to A 18 14 Load side FDB 3-P 15A to 225A 18 14 Load side HFD 1-P 15A and 20A 65 25 Load side HFD 2-P 15A to 30A 25 Load side HFD 3-P 15A to 225A 25 Load side 70A to 250A JD 2-P 250A 65 18 Load side JD 3-P 200A to 250A 65 18 Load side HJD 3-P 250A 25 Terminals extra 300A to 600A KD 3-P 200A to 400A 65 25 Load side HKD 3-P 300A and 400A 35 Terminals extra KDC 3-P 400A Therm/Mag Interchangeable Trip 200 65 Terminals extra LD 3-P 500A and 600A 65 25 Load side HLD 3-P 600A 35 Load side LGE 3-P 400A and 600A 65 18 Both Line/Load LGH 3-P 400A and 600A 25 Both Line/Load LGU 3-P 400A and 600A 200 35 Both Line/Load Eaton Molded Case s in Assemblies Amperage Range Panelboards Switchboards Motor Control Centres 1A 2A 3A 3E 4 5P PRL-C IFS Freedom FlashGard Enclosed Control FD/ED 15-225 JD 70-250 KD 70-400 LD 400-600 LG -600 Bus Plugs Enclosed
FDC 3 L EHD FDB FD HFD FDC of Poles 1 = 1 poles Trip Amperes 010 015 020 025 030 035 040 045 050 060 070 080 090 110 175 (FD, HFD, FDC, two-, three-, four-pole only) 200 (FD, HFD, FDC, two-, three-, four-pole only) 225 (FD, HFD, FDC, two-, three-, four-pole only) E = % protected (four-pole only) neutral pole EH = 50% protected (four-pole only) K = High magnetic molded case switch L = Line and load terminals S = Stainless steel terminals V = 50 C calibration Y = Line terminals only Z = Aluminum terminals ( amperes) EHD 1 14 2, 3 18 14 FDB 2, 3, 4 18 14 14 14 FD 1 35 2, 3, 4 65 35 35 18 HFD 1 65 2, 3, 4 65 65 25 EDC 3 200 L FDC 2, 3, 4 200 35 EHD EDS ED EDH EDC of Poles Trip Amperes 175 200 225 L = Line and load terminals Y = Line terminals only Z = Aluminum terminals ( amperes) EDB 2, 3 22 EDS 2, 3 42 ED 2, 3 65 EDH 2, 3 EDC 2, 3 200 JD 3 250 F / JDB JD HJD JDC of Poles / Ampere Rating 070 090 175 200 225 250 C = Non-aluminum terminals F = only K = High magnetic molded case switch V = 50 C calibration X = Load side terminals only Y = Line side terminals only The highlighted items identify which breakers are In stock and ready to go. 240 380 415 600 JD 2, 3, 4 65 35 35 HJD 2, 3, 4 65 65 JDC 2, 3, 4 200
KD 3 400 F DK KD KDB HKD KDC / Ampere Rating 175 200 225 250 300 350 400 C = Copper terminals E = 50% protected neutral pole (four-pole electronic trip unit circuit breaker only) F = only K = High-magnetic moldedcase switch V = 50 calibration (thermalmagnetic trip units only) X = Load terminals only Y = Line side terminals only Blank = Standard load and line side terminals KDB 2, 3, 4 65 35 25 KD 2, 3, 4 65 35 25 HKD 2, 3, 4 65 35 KGC 2, 3, 4 200 65 LD 3 600 F LDB LD HLD LDC CLD CHLD CLDC / Ampere Rating 300 350 400 450 500 600 C = Copper terminals F = only K = High-magnetic molded-case switch V = 50 calibration (thermalmagnetic trip units only) X = Load terminals only Y = Line side terminals only LDB 2, 3, 4 65 35 25 LD 2, 3, 4 65 35 25 CLD 2, 3, 4 65 35 25 HLD 2, 3, 4 65 35 CHLD 2, 3, 4 65 35 LDC 2, 3, 4 200 50 CLDC 2, 3, 4 200 50 L G S 3 600 FA G C L Standard Application G = IEC/CE/UL/CSA Performance 600 480 415 240 E 18 35 35 65 S 25 50 50 85 H 35 65 70 C 50 200 U 65 200 X 65 200 200 200 K Molded case switch 3 = Three 4 = Four Neutral 0% protected 6 = Four Neutral 60% protected 7 = Four Neutral % protected 8 = Four Neutral 0-60% protected 9 = Four Neutral 0-% protected Amperes 250 300 350 400 500 600 630 Trip Unit AA = Adj. adj. FA = Fixed adj. KS = Molded case switch 33 = 310+ electronic LS 32 = 310+ electronic LSI 35 = 310+ electronic LSG 36 = 310+ electronic LSIG 38 = 310+ electronic ALSI 39 = 310+ electronic ALSIG NN = only (no trip) Rating Blank = IEC/CE/UL/CSA C = % rated Terminals M = Metric end caps E = Imperial end caps G = Line/load standard Terminations/Hardware Mounting Hardware Metric Imperial Metric 240-240 Icu Icu 380-415 Icu Icu 480 600 LGE630 3, 4 65 65 35 35 35 18 LGS630 3, 4 85 85 50 50 50 25 LGH630 3, 4 70 70 65 35 LGC630 3, 4 200 200 50 LGU630 3, 4 200 200 65 LGX630 3, 4 200 200 200 200 200 65 The highlighted items identify which breakers are In stock and ready to go.
What You Need To Know 1. How many poles do you require? 2. What amperage do you need? 3. What is the interrupting rating of your panelboard? 4. What series is your panelboard? Purchase from an Authorized Eaton Distributor Panelboard Connector Kits (1990 to Present) Application Note CAUTION: Only use a breaker for which a connector exists for that panelboard. Any applications that cannot be satisfied by the listed connector kits should be referred to Eaton. USE OF A BREAKER IN A PANELBOARD FOR WHICH THEY ARE NOT INTENDED COULD RESULT IN SERIOUS DAMAGE AND/OR PERSONAL INJURY. POW-R-LINE 3 / Commander CHB2 (1991 to July 1994)/NFB/NFD Catalogue No,. CK3A CK3C POW-R-LINE 3a (July 1994 to Present ) KPRL3ABA06 KPRL3ABA12 KPRL3ABA18 KPRL3ABA24 KPRL3AGB06 KPRL3AGB12 KPRL3AGB18 KPRL3AGB24 KPRL3AFD3 KPRL3AFDS ALUMINUM - Superceded-Use CK3C for Al or Cu COPPER F-FRAME 3 POLE A MAX. For 6 circuits of BAB / QBHW / GFCBB BREAKERS (3X) For 12 circuits of BAB / QBHW / GFCBB BREAKERS (5X) For 18 circuits of BAB / QBHW / GFCBB BREAKERS (8X) For 24 circuits of BAB / QBHW / GFCBB BREAKERS (10X). For 6 circuits of GB / GBH BREAKERS (3X) For 12 circuits of GB/ GBH BREAKERS (5X) For 18 circuits of GB/ GBH BREAKERS (8X) For 24 circuits of GB / GBH BREAKERS (10X) FOR 2 SERIES C F-FRAME 1, 2, 3 POLE (3X) MAX SUM BREAKER 400A Select the appropriate breaker: F FRAME 3 POLE SINGLE MOUNT - OVER A 1) Confirm your breaker frame is listed in the assemblies chart on page two. If it is not consult Eaton. 2) Find your circuit breaker type from the selection pages. 3) Match the interrupting capacity, breaker type, number of poles and amperage required. 4) Select connector kit from this page, only required if you are adding additional circuits. Example: Require 3-Pole, 15A replacement FD feeder for 14kA Eaton PRL3A panelboard. Part# FD3015 3-P, 15A, 18kA 600V, thermal/magnetic non-interchangeable trip circuit breaker Part# KPRL3AFD3 Connector kit for 2 series C F-frame 1,2,3 pole POW-R-LINE 4 / Commander CDP2- Copper or Aluminum (Late 1990 to Present) KPRL4CA KPRL4FD2 KPRL4FD3 KPRL4LFD3 KPRL4FD3W KPRL4FBP KPRL4JDS KPRL4JDT KPRL4KDS KPRL4KDCT KPRL4CKDS KPRL4LCL KPRL4LAP KPRL4LD KPRL4LG KPRL4MA KPRL4MDL KPRL4NBP KPRL4ND KPRL4CND FOR 2 CA/CAH s - OBSOLETE SERIES C F-FR. 4 x 1 POLE OR 2 x 2 POLE-450A max. total (2X) FOR 2 SERIES C F-FRAME 3 POLE - 450A max. total (3X) FD+LFD BREAKER 3 POLE A max. FOR SERIES C-F-FRAME 3 POLE, WIDER CUTOUT (3X) FB TRIPAC BREAKER 3 POLE A max. JD SINGLE - 250A max. - (3X) JD TWIN - 250A max. - (3X) KD / HKD / KDC SINGLE - 400A max. - (4X) HKD/KDC TWIN - 400A max. - (4X) (Use with NEW KDC 65kA @ 600V - Replaced KPRL4KDT CKD SINGLE - 400A max. - (4X) LCL BREAKER 3 POLE 400A max. LA TRIPAC BREAKER 3 POLE 400A max. LA/HLA/LC/HLC/LD/HLD/LDC/CLD BREAKER 3 POLE 600A max. FOR SERIES G-L-FRAME 3 POLE MA/HMA/MC/HMC BREAKER 3 POLE 800A max. MDL/HMDL BREAKER 3 POLE 800A max. NB TRIPAC BREAKER 3 POLE 800A max. NB/HNB/ND/HND/NDC/NG BREAKER 3 POLE 1200A max. CND/NG BREAKER 3 POLE 1200A max. Application Notes for Powerline 3, 3a and 4 1990 to present: 1) JD and KD single connector kits fit in 24 and 30 wide panels. 2) JD and KD twin connector kits fit in 38, 44 and 48 wide panels. Note: Twin mounted KDC s for use at 65kA @ 600V must use KPRL4KDCT twin connector kits. Do not use KPRL4KDT. CDP Copper Panel (1976 to Late 1990) 1916B93G04 5106A10G98 5106A10G99 8985A09G02 CDP Panaflex Aluminum (Up to Late 1990) 1A00759G05* 8985A09G06* FOR 2 EB / FB / HFB BREAKERS - A max breaker. Line insulation kit REQUIRED for 2 pole HFD / FDC at 600V Line insulation kit REQUIRED for 3 pole HFD / FDC at 600V FOR 2 SERIES C K-FRAME BREAKERS 1,2,3 POLE SERIES C F-FRAME BREAKER A MAX.* 2,3 POLE SERIES C K-FRAME* Application Notes: 1) CDP Panaflex Aluminum panelboards that have not been retrofitted are not built to handle the means of interrupting of Series C breakers. Failure to follow the above application table could result in serious damage and personal injury. 2) Connector kits for Series C 600A LD and higher do not exist for CDP Panaflex. * CAUTION: Use these kits ONLY on retrofitted panels identified by a light blue label next to the panel rating label. IF NO BLUE LABEL, DO NOT USE!
I didn t know it was counterfeit. Identifying counterfeit products is extremely difficult. Counterfeiting costs global companies $500 billion annually. Counterfeit products look exactly like the real products but are made with inferior materials, inaccurate manufacturing processes and without functional or safety testing. Counterfeit electrical components create a dangerous environment for your customers or employees. Don t depend on your ability to spot a fake. Eaton is the only manufacturer of authentic replacements for Challenger, Powerware, Moeller Cutler-Hammer and Westinghouse electrical distribution and control products. Eliminate your risk of buying counterfeit products by purchasing through an Eaton authorized distributor. Always buy authentic; buy Eaton. To find an authorized distributor visit us at http://www.eatoncanada.ca/ eaton.com/counterfeit, EatonCA/ProductsSolutions/ under How Buy. Electrical/HowtoBuy For additional product support contact 1-877-BRK-SRVC. Eaton 0 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Electrical Sector Canadian Operations 5050 Mainway Burlington, ON L7L 5Z1 Canada EatonCanada.ca 2015 Eaton All Rights Reserved Printed in USA Publication No. SA012010EN April 2015 Eaton is a registered trademark. All other trademarks are property of their respective owners. Follow us on social media to get the latest product and support information.