Dual Port Manifold Water Filtration Systems Instruction Manual

Similar documents
Dual Flow Manifold Systems Instruction Manual

Scale Feeder Manifold Water Filtration System Instruction Manual

Dual/Triple Manifold Water Filtration Systems Instruction Manual

Full Flow Drinking Water System Model: 3MFF100

Installation and Operating Instructions

Intended Use: Explanation of Signal Word Consequences

Installation, Operation and Maintenance Manual

SAFETY INFORMATION & INSTRUCTION MANUAL

Installation, Operation and Maintenance Manual

MULTI-STAGE FILTRATION SYSTEM INSTALLATION INSTRUCTIONS

Owner s Manual WARNING

INSTALLATION INSTRUCTION & OWNER S MANUAL

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

ONLINE WARRANTY INFORMATION CrystalQuest.com/warranty.html

SUPERPLUS WATER FILTRATION SYSTEM

Door Edge Protection Film 36 inch

G E N E S I S R O C v AUTOMATIC REPLENISHMENT MODULE

BMK-30. Heavy-Duty By-Pass Filtration System Installation and Servicing Instructions

V400D VERIS Verabar (Double Rod) Installation and Maintenance Manual

Tri-Clover Manual and Air Actuated Fractional Valves

Operating Instructions and Parts Manual AHR-50 Auto Rewind Hose Reel

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

Operating Instructions & Parts Manual. Supa-Lite Lever Grease Gun. Model 48UJ77

V200D VERIS Verabar (Double Rod) Installation and Maintenance Manual

MEX (55) QRO (442) Web Controls

HALLMARK INDUSTRIES INC

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

Operating Instructions & Parts Manual. Air/Manual Hydraulic Bottle Jacks

Air Actuated Hydraulic Bottle Jacks

3M-MaticTM. Tape Edge Fold Kit. Instructions and Parts List. For Use On: AccuGlide TM STD Upper and lower Taping Heads. Purpose of Attachment

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT

V150 VERIS Verabar Installation and Maintenance Manual

GM Specification Annual Test Data

Nelsen Filtration Cartridge Systems

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

Buffer 8125 Owner s Manual

ESE Series Cast Iron Sewage Pumps

INSTRUCTIONS. Owner's Manual. Ionizing Air Nozzles Models AN-2 and AN-6

US Water ORP Booster Injection System

Sanitary Yard Hydrant Installation Instructions

GM Specification Annual Test Data

Owner s Manual Nitrate Series Salt Based Filter System

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

Heavy Duty Bottle Jacks

FASHION SKIRTED TOILET FOR P & S TRAPS DUAL FLUSH OWNER S MANUAL ITM. / ART # QTA023

Owner s Manual Pelican Whole House Iron and Manganese Filtration System

Transmission Guardian

3M TM Cubitron TM II Bonded Abrasive Grinding and Cut-Off Wheels. born to. grind. It s grinding reinvented. Featuring. cut & grind wheels

Customer Support

Reference Manual FM-200 Series

US Water ph Booster-Reducer Injection System

Installation, Maintenance, & Repair Series 995 Reduced Pressure Zone Backflow Preventers

3M Housings CH Series

Kit INSTALLATION GUIDE. For maximum effectiveness and safety, please read these instructions completely before proceeding with installation.

MODEL G300 BRAKE BLEEDER

INSTALLATION GUIDE. Rainier Coil Pull Down Kitchen Faucet PB-K01

V500 and V510 VERIS Verabar Installation and Maintenance Manual

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

Installation Manual DIAPHRAGM WELL TANK

75500MAX Series and 75500MAXM Series

Hydraulic Transmission Jack, Telescopic

Hydraulic Truck Jack

DAP-625S and DAP-875S

Manifold w/ Needle Valve Instruction Manual

2013 Mustang Chin Splitter

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

MR 5-30 Aviation Fuel Meter Owner s Manual

Benron Equipment & supply, Inc.

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

3M Collision Repair Solutions. 3M Abrasives and Power Tools. Cutting & Grinding. for Body Techs

Value Super Filter Max Installation Manual

SUBMERSIBLE SUMP PUMPS

NSF MODELS: CTP200, CTP100. This System does not require the services of a plumber. Read and Save these Instructions. Important

3MTM CubitronTM II Bonded Abrasive Grinding and Cut-Off Wheels. BORN TO GRIND. IT S GRINDING REINVENTED.

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

1-BUTTON DISPENSER INSTALLATION INSTRUCTIONS

BMK-27. Dual Remote Filtration System Mounting Kit. Installation and Servicing Instructions (DURAMAX) C. Oil Supply

ATTENTION: PLEASE READ AND UNDERSTAND ALL INSTRUCTIONS AND WARNINGS BEFORE ASSEMBLING, INSTALLING OR USING THIS PRODUCT.

DeZURIK 2 20" BOS BUTTERFLY VALVES

Installation Instructions / Warranty. Citterio 39115XX1

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

ProFlo FatBoy

Operating and Installation Instructions

GA-160 Gas Amplifier

AQUA2000 ADVANCED WATER TREATMENT SYSTEMS OWNER S MANUAL INCLUDES: Restrictions. Installation. Operation. Maintenance. Changing the Filter

ROMAN TUB 3 VALVE LONG STEM AND TRIM INSTALLATION INSTRUCTIONS Valve Body No Trim Kit for Model No s: 1047, 1707, 1727

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

Users Manual Certified Series Direct Drive Pump 1-7 LPM

5874SS/5874PB/5874PBF/VRK5874/PBA6/ PBA6HPB/PBA7 Valve/Push Button

US Water Systems Magna Pre-Filter

Instructions and Parts List 3M-Matic P/N Infeed/Exit Conveyor Attachment, 1.2 Meter

Gauge Adapter Instruction Manual

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Installation Instructions

Installation manual. 1.5 front leveling kit. Nissan Titan. Part # Part # Important customer information: Nissan Titan

Installation and Maintenance Instructions

3M Ladder Kit 3M710/MS 2 -TMK-LK

PURE WATER. Installation, Operation and Maintenance Manual. 3-Stage Under Counter Filtration with UV Model PWSYS-UV-3STG. Important.

Transcription:

M TM Water Filtration Products Dual Port Manifold Water Filtration Systems Instruction Manual For DP1XX, DP2XX and DPXX High Flow Series Water Filtration Systems Installer: Please leave this manual with owner/operator.

M Water Filtration Products Table of Contents Safety Information...2 Warning Statements...2 Caution/Important Notes... Dual Port Manifolds and Systems... Product Dimensions...4 Inlet and Outlet Connections...5 How to Use Push-in Connectors...5 How to Use Inlet/Outlet Fitting Retention Clips...5 Equipment Installation...5 Equipment Start-up Procedure...6 Cartridge Change-out Procedure...7 Troubleshooting...7 Parts Listing...8 Limited Warranty...11 SAFETY INFORMATION Read, understand, and follow all safety information contained in these instructions prior to installation. Retain these instructions for future reference. Intended Use: The M High Flow series dual port manifold water filtration systems are intended for use in filtering potable water in the foodservice industry and have not been evaluated for other uses. These systems are installed at the point of use and must be installed as specified in the installation instructions. WARNING CAUTION EXPLANATION OF SIGNAL WORD CONSEQUENCES Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury and/or property damage. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury and/or property damage. CAUTION Indicates a potentially hazardous situation, which, if not avoided, may result in property damage. WARNING To reduce the risk associated with choking: Do not allow children under years of age to have access to small parts during the installation of this product. To reduce the risk associated with the ingestion of contaminants: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. To reduce the risk associated with hazardous voltage due to an installer drilling through existing electric wiring or water pipes in the area of installation: Do not install near electric wiring or piping which may be in path of a drilling tool when selecting the position to mount the filter bracket. To reduce the risk of physical injury: Depressurize system as shown in manual prior to cartridge removal. To reduce the risk associated with back strain: Follow safe lifting procedures. 2

CAUTION To reduce the risk associated with property damage due to water leakage: Read and follow Use Instructions before installation and use of this system. Installation and Use MUST comply with all state and local plumbing codes. Protect from freezing, remove filter cartridge when temperatures are expected to drop below 40 F (4.4 C); Do not install on hot water supply lines. The maximum operating water temperature of this filter system is 100 F (7.8 C). Do not install if water pressure exceeds 125 psi (862 kpa). If your water pressure exceeds 80 psi (552 kpa), you must install a pressure limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure. Do not install where water hammer conditions may occur. If water hammer conditions exist, you must install a water hammer arrester. Contact a plumbing professional if you are uncertain how to check for this condition. Where a backflow prevention device is installed on a water system, a device for controlling pressure due to thermal expansion must be installed. Do not use a torch or other high temperature sources near filter system, cartridges, plastic fittings or plastic plumbing. On plastic fittings, never use pipe sealant or pipe dope. Use PTFE thread tape only, pipe dope properties may deteriorate plastic. Take care when using pliers or pipe wrenches to tighten plastic fittings, as damage may occur if overtightening occurs. Do not install in direct sunlight or outdoors. Do not install near water pipes which will be in path of a drilling tool when selecting the position to mount the bracket. Mount filter in such a position as to prevent it from being struck by other items used in the area of installation. Ensure that the location and fasteners will support the weight of the system when installed. Ensure all tubing and fittings are secure and free of leaks. The disposable filter cartridge MUST be replaced every 12 months, at the rated capacity or if a noticeable reduction in flow rate occurs. Any non-metallic fittings used in the installations must be of adequate rating for the line pressure. IMPORTANT NOTES Failure to follow instructions will void warranty. Allow a minimum of (7.6 cm) clear space under filter to facilitate cartridge change. Install with the inlet and outlet ports as labeled. Make sure not to reverse connections. Some local codes may require the use of a licensed plumber or certified installer when disrupting a potable water line. High Flow Series Dual Port Manifold Water Filtration Systems The High Flow series dual port (DP) manifold water filtration system cartridges help provide consistent high quality water for multiple applications of cold beverages, ice, and coffee. The inlet water enters the manifolds on the left rear side and flows through 1, 2, or cartridge filters in parallel (depending upon which manifold is installed). Two separate streams exit the manifold. One stream (on the right front side) has scale-inhibition media added from a dedicated cartridge to reduce the ability of calcium and magnesium to precipitate as hard scale in ice machines and coffee brewers. The other stream exits on the left side front. It supplies cold beverage dispensers and includes no scale inhibitor. The capacity of the system is equal to the total combined flow rate and capacity ratings for the number of cartridge filters used, regardless of the percentage of total outlet flow directed to a specific application.

Product Dimensions DP1XX Water Filtration System 19 1/16" (48.4 cm) 5 7/16" (1.8 cm) 24 9/16" (62.4 cm) " (7.6 cm) MIN DISTANCE REQUIRED TO REMOVE CARTRIDGE DP2XX Water Filtration System 22 7/8" (58.1 cm) 5 7/16" (1.8 cm) 24 9/16" (62.4 cm) DPXX Water Filtration System 1 1/16" (78.9 cm) " (7.6 cm) MIN DISTANCE REQUIRED TO REMOVE CARTRIDGE 5 7/16" (1.8 cm) 24 9/16" (62.4 cm) " (7.6 cm) MIN DISTANCE REQUIRED TO REMOVE CARTRIDGE 4

Inlet and Outlet Connections The water inlet is on the left side rear and the outlets are on both sides and are identified with labels. The fitting size is /4 NPT (Male). Built-in check valves (non-return) are incorporated into both outlets. How to Use Push-in Connectors CAUTION To reduce the risk associated with property damage due to water leakage: Do not install unit if collet is missing. Contact your Sales Representative if collets are missing The DP2XX & DPXX manifolds are outfitted with a user friendly Push In connector at the vent valve. Proper use of the connectors is shown in the figure below. It is most important that the tubing selected for use with these connectors be of high quality, exact size and roundness, and with no surface nicks or scratches. If it is necessary to cut the tubing, use a plastic tubing cutter or sharp razor knife. Make a clean square cut. Should a leak occur at a "Push-In" connector, the cause may be a problem with the tubing and new tubing may be required. To Attach Tubing To Release Tubing Push tubing straight in as far as it will go Tubing is secured in. Push in collet to release tubing. Pull tubing straight out. How to Use the Inlet/Outlet Fitting Retention Clips This product is outfitted with inlet/outlet fittings. The fittings can be attached or removed from the system without tools. Retention clips are semi-circular in shape with three internal tabs, bottom, center and top. Tab interlaces with windows in the manifold head near each connection port. Clip is flexible and easily assembled following these instruction and illustrations. 1. Insert fitting into manifold. 2. With fitting inserted into manifold port, snap clip into place beginning at the bottom window. Push center tab into center window. 4. Finally push top tab into top window. Step 1 Step 2 Step Step 4 Equipment Installation CAUTION To reduce the risk associated with property damage due to water leakage: Do not use a torch or other high temperature sources near filter system, cartridges, plastic fittings or plastic plumbing. On plastic fittings, never use pipe sealant or pipe dope. Use PTFE thread tape only, pipe dope properties may deteriorate plastic. Take care when using pliers or pipe wrenches to tighten plastic fittings, as damage may occur if overtightening occurs. Do not install near water pipes which will be in path of a drilling tool when selecting the position to mount the system. Mount filter in such a position as to prevent it from being struck by other items used in the area of installation. Ensure that the location and fasteners will support the weight of the system when installed. Ensure all tubing and fittings are secure and free of leaks. 5

IMPORTANT NOTES Failure to follow instructions will void warranty. Allow a minimum of in. (7.6 cm) clear space under filter to facilitate cartridge change. Install with the inlet and outlet ports as labeled. Make sure not to reverse connections. Some local codes may require the use of a licensed plumber or certified installer when disrupting a potable water line. CAUTION To reduce the risk associated with property damage due to water leakage: Any non-metallic fittings used in the installations must be of adequate rating for the line pressure. Manifolds may be used with metal or non-metallic piping systems. 1. Shut off incoming cold water supply. 2. Select the installation location. IMPORTANT NOTE: Allow a minimum of in (7.6 cm) of space below the cartridges for change-outs.. Select fasteners (not included) and tools appropriate for the installation location (wall, support structure mounted to wall studs, concrete, etc.) CAUTION To reduce the risk associated with property damage due to water leakage: Ensure that the location and fasteners will support the weight of the system when installed and full of water. 4. Mount the manifold/filter system to a wall using the mounting holes provided on the back plate of the metal bracket. It is recommended to first draw a level line on the mounting surface at the height of the fasteners. Mark the location of the fasteners using the bracket as a template or by measuring the distance between the mounting holes. Install the fasteners and allow 1/4 - /8 (6-10 mm) of each fastener to protrude from the surface. Install the manifold onto the fasteners. Tighten the fasteners. 5. Install inlet (left rear) and outlet fittings (right front to ice/coffee and left front to beverage) to the manifold. All connections terminate with a /4 NPT (male) fitting. The inlet kit includes a fitting and a ball valve. The left front outlet is a fitting only. The kit for the right side outlet to ice includes the fitting, a stainless-steel filter head, two (2) nipples and a check valve. The instructions for the installation clips are on page 5 (PTFE tape is not included). IMPORTANT NOTES: Be sure to install the stainless steel fitting head with the flow arrow. 6. Remove the sanitary caps from the water filter cartridges, and apply a light coat of water or water-grade lubricant to the o-rings on each of the cartridges. 7. Align the tabs of the cartridge with the slots in the retaining plate and insert the cartridge into the manifold. 8. Turn the cartridge to the right until a clicking sound is heard. Repeat for the remaining cartridges; the clicking sound indicates the cartridge is properly engaged. 9. Install the smaller scale inhibitor cartridge by engaging the threads in the stainless steel tee and rotating to the right (clockwise) until snug, regardless of final label orientation. Equipment Start-up Procedure 1. Turn on incoming water to system. 2. Pressurize system by rotating the inlet ball valve handle on the manifold to the left (counterclockwise) to the ON position.. Check for leaks. 4. Flush system in accordance with performance data sheet supplied with the water filtration cartridges. 6

Cartridge Change-out Procedure CAUTION To reduce the risk associated with property damage due to water leakage: Read and follow Use Instructions before installation and use of this system. The disposable filter cartridge MUST be replaced every 12 months, at the rated capacity or if a noticeable reduction in flow rate occurs. The water filter cartridges will need to be changed every 6-12 months, at the rated capacity, or when low pressure in indicated on the manifolds pressure gauge, whichever occurs first. Depending on local water quality, you may need to change the cartridges prior to the recommended change-out. The loss of flow to carbonators or improper fill at the ice maker are also indicators that the cartridges will need to be replaced 1. Shut off the inlet water by rotating inlet ball valve 1/4 turn to the left (clockwise) on manifold to the OFF position. 2. Depressurize system. Use plastic tubing and vent valve for DP2XX and DPXX manifolds. There is no vent valve on DP1XX manifold.. Push tab to release cartridge locking mechanism while simultaneously rotating cartridge slightly to the left. To reduce the risk associated with back strain: Follow safe lifting procedures. WARNING 4. Using both hands and holding cartridge from the bottom, rotate the cartridge a quarter turn to the left and gently pull down. IMPORTANT NOTE: A small amount of water will drain from manifold as cartridge is removed. 5. Remove the sanitary caps from the water filter cartridges, and apply a light coat of water or water-grade lubricant to the o-rings on each of the cartridges. Align the tabs of the cartridge with the slots in the retaining plate and insert the cartridge into the manifold. Turn the cartridge to the right until a clicking sound is heard. Repeat for the remaining cartridges; the clicking sound indicates the cartridge is properly engaged. 6. Slowly turn the inlet water ball valve on the manifold to the left (counterclockwise) to the ON position, and check for leaks. 7. Install the smaller scale inhibitor cartridge by engaging the threads in the stainless steel tee and rotating to the right (clockwise) until snug, regardless of final label orientation. 8. Flush system in accordance with performance data sheet supplied with the water filtration cartridges. Troubleshooting No water flow through system Inlet valve closed Filters clogged Check shut-off valve position Replace filter cartridge(s) Not enough water to downstream application Low incoming water pressure Filters clogged Check source Replace filter cartridge(s) Short filter life Temporarily dirty water Change cartridges or install an additional upstream pre-filter 7

DP1XX Replacement Parts Listing Item Part no. Description Qty* Function 1 622860 DP1XX Single Manifold 1 Assembly, complete 2 See catalog Replacement Cartridge 1 Water filtration 8500556 Pressure gauge 1 Monitor outlet water pressure 4 85-8528 Clip 1 Retain inlet/outlet fittings 5 659720 o-ring 1 Seal inlet/outlet fittings 6 6225008 Inlet fitting kit left rear 1 Inlet fitting with ball valve 7 6225006 Outlet fitting kit left front 1 Beverage outlet fitting 8 6225007 Outlet fitting kit right front 1 Ice/Coffee outlet fitting 9 60-25280 ¾ Female NPT ball valve 1 Inlet water shut-off 10 5617501 Retainer kit 1 Secure cartridges 11 5582106 HF8-S Replacement Cartridge 1 Scale inhibitor *Per part number, not per system or assembly. 6 Rear 4 8 Front 5 5 Inlet Outlet 9 1 10 7 Front Outlet 2 11 8

DP2XX Replacement Parts Listing Item Part no. Description Qty* Function 1 622850 DP2XX Twin Manifold 1 Assembly, complete 2 60-2700 Vent Valve 1 Release trapped air See catalog Replacement Cartridges 1 Water filtration 4 8500556 Pressure gauge 1 Monitor outlet water pressure 5 85-8528 Clip 1 Retain inlet/outlet fittings 6 659720 o-ring 1 Seal inlet/outlet fittings 7 6225005 Inlet fitting kit left rear 1 Inlet fitting with ball valve 8 6225006 Outlet fitting kit left front 1 Beverage outlet fitting 9 6225007 Outlet fitting kit right front 1 Ice/Coffee outlet fitting 10 60-25280 ¾ Female NPT ball valve 1 Inlet water shut-off 11 5617501 Retainer kit 1 Secure cartridges 12 5582106 HF8-S Replacement Cartridge 1 Scale inhibitor *Per part number, not per system or assembly. 7 Rear 5 4 6 9 Front Inlet Outlet 10 1 6 11 8 Front Outlet 2 12 9

Item Part no. Description Qty* Function 1 622840 DPXX Triple Manifold 1 Assembly, complete 2 60-2700 Vent Valve 1 Release trapped air See catalog Replacement Cartridges 1 Water filtration 4 8500556 Pressure gauge 1 Monitor outlet water pressure 5 85-8528 Clip 1 Retain inlet/outlet fittings 6 659720 o-ring 1 Seal inlet/outlet fittings 7 6225005 Inlet fitting kit left rear 1 Inlet fitting with ball valve 8 6225006 Outlet fitting kit left front 1 Beverage outlet fitting 9 6225007 Outlet fitting kit right front 1 Ice/Coffee outlet fitting 10 60-25280 ¾ Female NPT ball valve 1 Inlet water shut-off 11 5617501 Retainer kit 1 Secure cartridges 12 5582106 HF8-S Replacement Cartridge 1 Scale inhibitor *Per part number, not per system or assembly. 7 Rear 5 4 9 Front 6 Inlet Outlet 10 6 1a 11 7 Front Outlet 2 12 10

Limited Warranty M Purification Inc. warrants DP1XX, DP2XX, DPXX High Flow series water filtration systems only to be free from defects in material and workmanship for five (5) years from the date of purchase. The disposable filter cartridge is warranted from defects in material and workmanship for a period of one (1) year from the date of purchase. This warranty does not cover failures resulting from abuse, misuse, alterations or damage not caused by M Purification Inc. or failure to follow installation and use instructions. No warranty is given as to the service life of any filter cartridge or membrane as it will vary with local water conditions and consumption. M PU- RIFICATION INC. MAKES NO OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED WARRANTY OR CONDITION ARISING OUT OF A COURSE OF DEALING, CUSTOMER OR USAGE OF TRADE. If the Product fails to satisfy this Limited Warranty during the warranty period, M Purification Inc., at it s option, will replace the Product or refund your Product purchase price. This warranty does not cover labor. The remedy stated in this paragraph is Customer s sole remedy and M Purification Inc. s exclusive obligation. This warranty gives you specific legal rights, and you may have other rights which may vary from state to state, or country to country. For any warranty questions, please call 866.990.9785 or mail your request to: Warranty Claims, M Purification Inc., 400 Research Parkway, Meriden, CT 06450. Proof of purchase (original sales receipt) must accompany the warranty claim, along with a complete description of the Product, model number and alleged defect. Limitation of Liability: M Purification Inc. will not be liable for any loss or damage arising from this M Purification Inc. product, whether direct, indirect, special, incidental, or consequential, regardless of the legal theory asserted, including warranty, contract, negligence or strict liability. Some states and countries do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. 11

Important Notice The information described in this literature is accurate to the best of our knowledge. A variety of factors, however, can affect the performance of the Product(s) in a particular application, some of which are uniquely within your knowledge and control. INFORMATION IS SUPPLIED UPON THE CONDITION THAT THE PERSONS RECEIVING THE SAME WILL MAKE THEIR OWN DETERMINATION AS TO ITS SUITABILITY FOR THEIR USE. IN NO EVENT WILL M PURIFICATION INC. BE RESPONSIBLE FOR DAMAGES OF ANY NATURE WHATSOEVER RESULTING FROM THE USE OF OR RELIANCE UPON INFORMATION. It is your responsibility to determine if additional testing or information is required and if this product is fit for a particular purpose and suitable in your specific application. M is a trademark of M Company. 2012 M Company. All rights reserved. INSTR425 0912B Please Recycle. Printed in U.S.A. 12 M Purification Inc. 400 Research Parkway Meriden, CT 06450 U.S.A. Tel: 866.990.9785 20.27.5541 Fax: 20.28.8701 www.mfoodservice.com www.mpurification.com