Product presentation SITRANS P310 Unrestricted / Siemens 2016. All Rights Reserved. usa.siemens.com/pressure
SITRANS P family Page 2
SITRANS P pressure transmitter Single range transmitters for general applications Food, pharmaceutical and biotechnology WirelessHART Paper industry Page 3
SITRANS P pressure transmitter Basic requirements Advanced requirements Premium requirements SITRANS P310 SITRANS P DS III SITRANS P410 SITRANS P500 Page 4
SITRANS P310 The highlights at a glance: Accuracy 0.075 % Long-term stability 0.25 % / 5 years or even 0.125 % / 5 years Wetted parts in stainless steel 1.4404/316L, Hastelloy C276 Measuring ranges from 60 mbar (0.4 inch H2O) to 700 bar (10153 psi) Diagnostics functions with PDM Page 5
SITRANS P310 versions MLFB Gauge pressure 7MF2033-*****-**** Differential pressure (Δp) 7MF2433-*****-**** Page 6
SITRANS P310 The perfect solution for your requirements: Various applications The SITRANS P310 offers you versions for gauge and differential pressure, flow, and level measurement. Degree of Protection IP66, IP68 Certification Configuration ATEX, NEPSI, FM/CSA SIL2/3, NACE The SITRANS P310 offers you the option of using 3 pushbuttons or PDM to configure the transmitter. Communication HART Page 7
SITRANS P310 7MF20* gauge pressure transmitter 7MF24* differential pressure transmitter Page 8
SITRANS P310 differential pressure measuring cell Page 9
SITRANS P310 overload Page 10
SITRANS P310 7MF20* gauge pressure 7MF20* Process connection Measuring cells Connection shank G½B to EN 837-1 Female thread ½-14 NPT Oval flange made of stainless steel Mounting thread 7/16-20 UNF to EN 61518 Wetted parts materials (seal diaphragm) Stainless steel, mat. No. 1.4404/316L Hastelloy Applications Gauge pressure measurement for pipes and vessels Process temperature up to 212 F 14.5 psi 58 psi 232 psi 914 psi 2320 psi 5802 psi 10153 psi 1 bar 4 bar 16 bar 63 bar 160 bar 400 bar 700 bar Page 11
SITRANS P310 7MF24* differential pressure (Δp) and flow 7MF24* Process connection Measuring cells Female thread ¼-18 NPT with flange connection Wetted parts materials (seal diaphragm) Mounting thread 7/16-20 UNF PN160 4.07 inh 2 O 100.4 inh 2 O 240.9 inh 2 O 642.4 inh 2 O 2008 inh 2 O 435 psi 60 mbar 250 mbar 600 mbar 1600 mbar 5000 mbar 30 bar Applications: Differential pressure measurement for pipes and vessels Level measurement for closed vessels High accuracy gauge measurement + side of the measuring cell to the process - side of the measuring cell open (to atmosphere) Page 12 Flow measurement (primary elements; e.g. SITRANS F O) Filter monitoring: Δp (before and behind filter)
SITRANS P310 Enclosure Die-cast aluminum Stainless Steel precision housing Page 13
Stainless steel process flanges for vertical differential pressure lines [H03] +H03 H03 with vent on side Page 14
Design remote seal systems Components Pressure transmitter One or two remote seals Filling liquid Connection between pressure transmitter and remote seal (direct mounting or by means of capillary) Diaphragm seals of flange design, directly fitted on a pressure transmitter for pressure Page 15
SITRANS P310 Overview Electrical connection / cable entry Screwed gland M20x1,5 Screwed gland ½-14 NPT Han 7D plug (plastic housing) Han 7D (metal, gray) [A31] Angled [A32] Han 8D (metal, gray) [A33] Electronics housing Die-cast aluminum Stainless steel precision casting Sealing screws ¼-18 NPT, with valve [A40] O-rings for process flanges Process flange Stainless steel (cast) Viton (standard) PTFE [A20] FEP with silicone core, approved for food applications [A21] FFPM (Kalrez compound 4079) [A22] Page 16
Functional safety SITRANS P SIL Class Order code Order No. P310 / HART SIL2 C20 7MF2033 7MF2433 P310 / HART SIL2/3 C23 7MF2033 7MF2433 Page 17
SITRANS P310 valve manifolds SITRANS P310 valve manifold versions: 7MF9011-4EA / 7MF9011-4FA 7MF9411-5BA / 7MF9411-5CA Page 18
SITRANS P310 Communication possibilities On-site operation via 3 push buttons even in ex areas! Adjustment of: Zero and span Damping Zero adjustment (position correction) Current transmitter Output current in case of fault Button lock / function lock Characteristic curve (Square root extracting) Measured value display Unit Page 19
SITRANS P310 Push buttons Mode Function 02 Set start of scale 03 Set full Scale 04 Adjust electrical damping 05 Blind adjusting: Start of scale 06 Blind adjusting: Full scale 07 Zero adjustment (position correction) 08 Current transmitter (Loop check function) 09 Failure current in case of fault 10 Key and/or function disable 11 Characteristic curve - linear or square root function 12 Application point of the curve with root extraction 13 Selection of the measured value display 14 Pressure Engineering units Page 20
Easy to us pushbuttons! Page 21
SITRANS P Industry SITRANS P P500 P410 P DS III P310 P300 Industry Chemical Best fit Selective fit Best fit Selective fit No Focus Energy Best fit Selective fit Best fit MAC Best fit Selective fit Best fit Selective fit Selective fit No Focus No Focus Oil & Gas Best fit Best fit Best fit Best fit No Focus Food & Beverage No Focus No Focus Selective fit No Focus Best fit Pharmaceuticals & Cosmetics Pulp & Paper Selective fit No Focus Best fit No Focus No Focus Best fit No Focus Selective fit Best fit Selective fit Water / Wastewater No Focus No Focus Best fit Selective fit Selective fit Factory automation No Focus No Focus No Focus No Focus No Focus Page 22
SITRANS P Industry SITRANS P P Compact P280 LH100 P250 P200 - P220 Industry Chemical No Focus No Focus No Focus No Focus No Focus Energy No Focus Selective fit No Focus No Focus Selective fit MAC No Focus Selective fit Selective fit No Focus Best fit Oil & Gas No Focus No Focus No Focus No Focus No Focus Food & Beverage Best fit No Focus No Focus No Focus No Focus Pharmaceuticals & Cosmetics Best fit No Focus No Focus No Focus No Focus Pulp & Paper No Focus Selective fit No Focus No Focus No Focus Water / Wastewater Best fit Best fit Best fit No Focus Best fit Factory automation No Focus No Focus No Focus Best fit Best fit Page 23
SITRANS P310 application gauge pressure measurement Pressure measurement at the coke oven Pressure measurement at the steam pipe 206 x SITRANS P310 Industry: coking plant / china Customer advantages: economic solution good price- /performance ratio Easy installation configuration via 3 pushbuttons Page 24
SITRANS P310 Operation via Software SIMATIC PDM V8.1 Page 25
Wizard Quick Start Guided adjustment Page 26
SIMATIC PDM V8.1 Diagnostics / Process Variables Trend View Page 27
SITRANS P310 FI01- catalog Page 28
SITRANS-P DS III--Sales-Presentation--2015-06-11-EN.pptx Thank you for your attention! For Process Instrumentation products contact: Siemens Process Instrumentation Phone: (800) 365-8766 Fax: (972) 522-4503 usa.siemens.com/pressure Page 29