Metal Seated Ball Valve. Operation and Maintenance Manual. Job Name: Contractor: Date: Document #: MSBVOM Revision Date: 07/06/09

Similar documents
Henry Pratt MDT Actuators. Operation and Maintenance Manual. Job Name: Contractor: Date: Document #MDTOM Revision Date: 1/12/11

24-48 HP250II Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date: Document #: 2448HP250OOOM Revision Date: 1/10/11

3-20 2FII & Groundhog Bonded Seat Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date:

3-20 2FII & Groundhog Bonded Seat Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date:

2" - 24" OS Series Butterfly Valves. Operation and Maintenance Manual. Job Name: Contractor: Date:

Rectangular Butterfly Valve

INSTRUCTION MANUAL RECTANGULAR BUTTERFLY VALVE 3-SIDED SEAT

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

DeZURIK KUL KNIFE GATE VALVES

24 and Larger Butterfly Valves

DeZURIK 2 20" BOS BUTTERFLY VALVES

APCO CVS-6000 CONVERTIBLE SWING CHECK VALVES

740G Double Disc Check. Valve. Operation / Maintenance Manual. General Information 2. Installation/Operation 3

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

DeZURIK 2-24 (50-600mm) KGC ES or HD KNIFE GATE VALVES

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT

DeZURIK KSV CL150 & CL300 BONNETLESS KNIFE GATE VALVES

VSI, LLC SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES INSTALLATION, OPERATION AND MAINTENANCE MANUAL

VSI INDUSTRIAL BALL VALVES SERIES 7100 SERIES 8100 SERIES 7200 SERIES 8300 SERIES 7400 SERIES 8400 SERIES 8000 SERIES 8500

3" 20" Bonded Seat Butterfly Valves

DeZURIK 24" THRU 36" RESILIENT BUTTERFLY VALVES

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

740G Double Disc Check Valve

DeZURIK KGC-MD KNIFE GATE VALVES

APCO CSV-1600 SURGE CHECK VALVE

DeZURIK VPB V-PORT BALL VALVES

Recommended spare parts are listed on the assembly drawing. These parts should be stocked to minimize downtime.

DeZURIK DR 125 ROTARY DIAPHRAGM ACTUATOR

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

DeZURIK DR 40B ROTARY DIAPHRAGM ACTUATOR

720A Wafer & 821A Globe Style

CSA products for waste water. Anti water hammer combination air valve. Mod. SCF-RFP

582 Series. Instruction Manual. Two-Door Wafer Check Valve N-582 (R-08/2016)

720G Wafer and 821G Globe Style Silent Check Valves

DeZURIK PEC ECCENTRIC VALVES

INSTALLATION, OPERATION AND MAINTENANCE FOR SERIES 500 K-FLO BUTTERFLY VALVES

CSA products for treated water. Water Combination air valve. Mod. FOX 3F RFP and Lynx 3F RFP

DeZURIK 2-16" PTW & PFW TAPERED PLUG VALVES

DeZURIK G-SERIES MANUAL ACTUATOR USED ON BOS BUTTERFLY VALVES

DeZURIK M-SERIES MANUAL ACTUATOR

DeZURIK MANUAL G-SERIES ACTUATOR USED ON PEF 100% PORT PLUG VALVES

DeZURIK LA-SERIES MANUAL & ELECTRIC ACTUATORS

Val-Matic Extended Bonnet Assembly Instructions

Spring-Engaged/Hydraulically-Released BD Caliper Brake. (i) MTY (81) QRO (442) MEX (55)

DeZURIK MANUAL G-SERIES ACTUATORS USED ON PEC ECCENTRIC VALVES

CSA products for waste water. Combination air valve. Mod. SCF 2

MANUAL ACTUATOR FOR KNIFE GATE VALVES

APCO CVS-250/250A SWING CHECK VALVES

PO Box 411 Berwick PA VALV

DeZURIK MODELS P41, P41D AND P42 PMV POSITIONERS

Nor East. Instructions. Safety Messages. Inspection. Parts Nor East Controls. Service. Type 05 Air-O-Motor Actuator Used With Globe Valves

DeZURIK SPRING RETURN CYLINDER OPERATOR FOR G-SERIES ACTUATORS USED ON PEF 100% PORT ECCENTRIC VALVES

APCO SRG-6500 SURGE RELIEF GLOBE VALVES

DeZURIK TEN-POSITION LEVER MANUAL ACTUATOR

Installation, Operation and Maintenance of Airflex Quick Release Valve

DeZURIK BHP HIGH PERFORMANCE BUTTERFLY VALVE

AWWA C504. Double Eccentric AWWA C504

PMV P36C AND P41C POSITIONERS ACTUATORS

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

CAST STEEL FLANGED GATE, GLOBE, & CHECK VALVES

DeZURIK " PEC ECCENTRIC VALVES

INTRODUCTION INSTALLATION

Airflex DPA Caliper Brake CA Installation, operation and maintenance manual

Val-Matic QuadroSphere Trunnion Mounted Ball Valve

Flow Control. Before installation or maintenance, these instructions must be fully read and understood.

DeZURIK CYLINDER OPERATED T-SERIES ACTUATOR

HR-20P Pneumatically Controlled Pressure Regulator

Val-Matic 3-Way Tapered Plug Valve

Operation and Maintenance Manual for Joyce Dayton. Integrated Actuator- Acme Screw. Maximum capacity: 2000-pounds

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS

MERIDIAN, 2 or 3 PIECE, TRUNNION MOUNTED BALL VALVES

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

APCO ACS-1200/1700 COMBINATION SLOW CLOSING AIR/VACUUM VALVE

V400D VERIS Verabar (Double Rod) Installation and Maintenance Manual

INSTALLATION AND OPERATING MANUAL

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com W D0446-A 4/1/05 1

PATRIOT LIFT CO. ON-Lift Installation Guidelines

Nor East /9500 Series Double Seated Cage Valves. Instructions. Safety Messages. Inspection. Parts. Nor East Controls Service

Hand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 )

ORIGINAL INSTRUCTIONS G715A. Pneumatic-hydraulic Riveter E. Warner Ave Santa Ana, CA

Val-Matic 3"-24" Butterfly Valve With LSA Actuator and External Stops

Val-Matic 1/2-3 Well Service Air Valve With Dual Port Throttling Device

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

Ballcentric Plug Valve

TECHNICAL SERVICE MANUAL

PRODUCT OBSOLETED 4Q16

Operating and Maintenance Instructions

Swing-Flex Check Valve

DeZURIK PNEUMATIC CYLINDER OPERATOR FOR G-SERIES ACTUATORS

Model GX Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

RESILIENT SEATED CARTRIDGE STYLE BFV S

IOM Manual. IOM Manual. Series 76/77.

Installation and Operating Instructions

RolsplicerTM. Maintenance Manual And Illustrated Parts List

SPECIFICATIONS CONTENTS:

Owner s Manual. Powered Dandy Lifts PLM-100, PLM100W, PLM150, PLM-150W. (See separate manual for PLM-250) Model # Serial #

SPECIFICATIONS CONTENTS:

I & M Mark 708ME. Ideal Installation. Start-Up Procedure. Installation & Maintenance Instructions for Mark 708 & Motor Actuator

Transcription:

Metal Seated Ball Valve Operation and Maintenance Manual Job Name: Contractor: Date:

SAFETY MESSAGES All safety messages in the instructions are fl agged with an exclamation symbol and the word Warning. These messages indicate procedures that must be followed exactly to avoid equipment damage, physical injury, or death. Safety labels on the product indicate hazards that can cause equipment damage, physical injury, or death. Personnel involved in the installation or maintenance of valves should be constantly alert to potential emission of pipeline material and take appropriate safety precautions. Always wear suitable protection when dealing with hazardous pipeline materials. PARTS Order parts from your local Henry Pratt sales representative or directly from Henry Pratt Company. When ordering parts, please include the serial number located on the valve tag. WARRANTY ISSUE Seller warrants that, at its option, it will repair, replace, or refund the unit purchase price of any products which are non-conforming due to Seller s material or workmanship during the warranty period. The warranty period shall be twelve (12) months for parts and eighteen (18) months for all other goods after date of shipment. This shall be Buyer s sole remedy. In order to maintain this product warranty, Buyer must give written notice to Seller s Field Service Supervisor prior to any work being performed. IN CONSIDERATION OF THE FOREGOING, SELLER EXCLUDES ALL OTHER EXPRESS OR IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Seller does not warrant water operated metallic cylinders against damage caused by corrosion, electrolysis or mineral deposits. In no event shall warranty include valve removal or reinstallation. Read all applicable directions and instructions prior to any maintenance, troubleshooting or installation 2

Table of Contents FUNCTIONAL DESCRIPTION 4 INSTALLATION 5 OPERATION 5 MAINTENANCE 6 TROUBLESHOOTING 7 CONTACTING PRATT 8 PRODUCT DRAWINGS 9 3

FUNCTIONAL DESCRIPTION Ball valve rotors rotate 1/4 turns to provide tight shutoff in air or water pipelines. The valves can be used to regulate fl ow rate or pressure by positioning the rotor between 15 and 90 degrees open. Manually operated ball valves are powered with gear actuators, which convert multiple handwheel, chainwheel or nut input turns into 1/4 turn valve operation. The travel of the valve disc is limited by physical stops in the actuator housing. Forcing the handwheel, chainwheel or nut against the stops will not provide tighter shutoff of the valve and may damage the actuator. Only actuator adjustments will affect valve shutoff. Motor operated ball valves are powered with gear actuators, which convert multiple motor input turns into 1/4 turn valve operation. The travel of the valve rotor is limited by limit switches in the motor housing and physical stops in the actuator housing. Valve shutoff is affected by limit switch and physical stop settings. Improperly set limit switches and/or physical stops may damage the motor and/or actuator. Hydraulically operated ball valves are powered with a gear box and double acting cylinder. The linear stroke of the cylinder is converted to 1/4 turn operation by the gear box. Auxiliary controls are provided to direct hydraulic power to the cylinder and to control the operating speed of the cylinder. 4

INSTALLATION The metal seated ball valve is factory tested for leakage and the seat is set to the correct position during this testing procedure. Then it is opened against an unbalanced working pressure to check that no wedging or galling of the seat is taking place. As this leakage test is performed without the valve being subjected to any extraneous pipeline stresses, it is important to remember that when installing the valve in the line that the same conditions are applied, as bad installation practices may alter the seat setting. The valve is designed to rest on top of a base plate which would allow free lateral movement with the pipeline, and it should not be bolted down as this can also cause misalignment of the seats. The base plate is typically tied into either a concrete or grout pad. Valve shall be supported on the four support legs having lifting lug taps in them. The valve should never be used for pipeline support, in fact care should be taken to see that this is not the case. It is advisable to make sure that the bolt holes at the connections between the valve flange face and the pipe flange face have enough clearance to enable the pipe and valve to be bolted together without any distortion. Installation of your Ball Valve should be accomplished by personnel well versed in piping installations and who are familiar with the end confi guration used to join the components. The use of standard, good joining procedures are all that are normally required. The only notable precaution would be in regard to the direction of fl uid fl ow. The seat side of the valve must be oriented so that pressure pushes the rotor or ball toward the seat end of the valve. On pump discharge applications, the seat is located on the pump side of the valve. OPERATION Flow control is achieved by rotating the rotor inside of the pipeline about its diametrical axis, hence changing the total free fl ow area of the valve. Positioning of the rotor is achieved by the valve actuator which has been mounted, adjusted, and tested at our Plant. Your valve may be motor, cylinder, or manually operated. 5

MAINTENANCE Although the actuator may or may not require periodic maintenance (depending upon which actuator is used), the valve itself requires no periodic maintenance. Pratt Ball Valves are supplied with selflubricating type sleeve bearings. No maintenance attention to them is necessary. However, after many years of continued service, the stem packing may show signs of wear. If repair becomes apparent (by leaking) contact Henry Pratt s Field Service Department immediately for repair options. The metal seat located on the valve rotor provides a tight seal by fl exing toward the body seat when under pressure. There is a factory set gap of.005 to.010 between the seat and rotor to provide a tight seal at the operating pressure and minimize wear during valve travel. To provide a seal at low pressure applications (less than 50 psig) it may be necessary to adjust the seat. Contact Henry Pratt s Field Service Department immediately for information regarding seat adjustments.options. 6

TROUBLESHOOTING PROBLEM CAUSES REMEDIES Leakage between valve and actuator Packing leak Clean packing bore and replace packing Bottom trunnion leaks Nut Seal leak Replace nut seal Valve leaks when closed Rotor not full closed or past fully closed Rotor edge wear or damage Flexible seat wear or damage Loose debris in valve Adjust actuator closed position stop Clean and/or repair edge Adjust or replace seat Cycle valve fi ve times to fl ush out debris Valve hard to operate Foreign material in valve Corroded actuator parts Loose actuator Insuffi cient seat gap Remove obstructions Clean and grease actuator Apply Loctite and tighten bolts Contact Pratt Field Service for seat adjustment information 7

HOW TO CONTACT PRATT HOW TO ORDER PARTS: To order parts, contact our Parts Department: Write: - Henry Pratt Company 401 South Highland Avenue Aurora, IL 60506-5563 Attn: Parts Manager Call - (630) 844-4000 Fax - (630) 844-4191 Please include valve serial number and description of part requested. HOW TO OBTAIN SERVICE: To obtain further information or secure fi eld service, contact our Field Service Department: Write: - Henry Pratt Company 401 South Highland Avenue Aurora, IL 60506-5563 Attn: Field Service Manager Call - (630) 844-4163 Fax - (630) 844-4160 Please include the following with your inquiry for service: Henry Pratt Order Number: Henry Pratt Item Number: Valve Serial Number: Type of Service Requested 8

Pratt Metal Seated Ball Valve Parts Drawing 9