Synchronous motor with fluid coupling drive arrangement for a preheater ID Fan. presenter Nathan Schachter CIMENTEC Engineering Ltd

Similar documents
Synchronous motor control. 8/15/2007 Powerflow Technologies Inc 1

POWER FACTOR IMPROVEMENT CONCEPT FOR LARGE MOTORS

Motor Protection Fundamentals. Motor Protection - Agenda

CLIENT: PROJECT: PO#: ESTIMATOR:

Scheme - I. Sample Question Paper

team master medium voltage solid state starters

Starting of Induction Motors

CUSTOMER / ACCOUNT INFORMATION Electric Utility Customer Information (As shown on utility bill)

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

ELECTRIC MACHINES EUROLAB 0.3 kw

Model NA 2 L

Rating Definitions and Conditions

This webinar brought to you by the Relion product family Advanced protection and control IEDs from ABB

EXPERIMENT 2 THREE PHASE INDUCTION MOTOR, PART 1

Rating Definitions and Conditions

Model MP150 W W

LARSEN & TOUBRO LIMITED TYPICAL SCHEME FOR PROTECTION OF SYNCHRONOUS MOTORS

Rating Definitions and Conditions

Rating Definitions and Conditions


Rating Definitions and Conditions

DESIGN CONSIDERATIONS FOR APPLICATION OF SHUNT CAPACITORS IN HEAVY HATER PLANT (TUTICORIN)

PRIMELINE. Induction Generator. Now Introducing Single Bearing Designs. Simple, Reliable Power For Wind or Engine Driven Applications

EXPERIMENT 19. Starting and Synchronizing Synchronous Machines PURPOSE: BRIEFING: To discover the method of starting synchronous motors.

Annex A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 400V (750KVA) DIESEL

Electrical Machines -II

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

825-P Modular Protection System for motors Specification Guide

Pretest Module 21 Units 1-3 AC Generators & Three-Phase Motors

GENERATOR INTERCONNECTION APPLICATION

AF series contactors (9 2650)

ALTERNATOR STARTUP Turning gear to full operation. Procedure initiated by:. 7/03 Before starting procedure, remove all check marks.

CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR

PF Guard Power Factor Capacitor Bank Installation, Operation, and Maintenance Manual

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

Power Solutions Manager Generac Power Systems, Inc.

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors

CATEGORY 2 GENERATOR INTERCONNECTION APPLICATION

Form G5-1 PACIFIC GAS AND ELECTRIC COMPANY GENERATION PRE-PARALLEL INSPECTION

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

ELECTRIC MACHINES EUROLAB 0.3 kw

Electric Utility Contact Information Indiana Michigan Power

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT

Date: Name: ID: LABORATORY EXPERIMENT NO. 8 INDUCTION MOTOR/GENERATOR 8-1

CI-TI Contactors and motor starters Types CI 61 - CI 98

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR CLASSIFICATION. 2010, The McGraw-Hill Companies, Inc.

DG SYNCHRONIZING &AMF PANEL

STANDBY 200 ekw 250 kva

PAC TRAINING PUMP MOTORS

Decision-Makerr Paralleling System

AF series contactors (9 2650)

ROTATING MAGNETIC FIELD

Product Information Packet CP500808LR-4 800HP,897RPM,3PH,60HZ,G50,A95260M,TEFC,F

Introduction to Variable Speed Drives. Pekik Argo Dahono Electrical Energy Conversion Research Laboratory. Institute of Technology Bandung

ELG4125: Flexible AC Transmission Systems (FACTS)

Ceramic PTC Thermistor:

Product Information Packet ECP50504L-4 500HP,1789RPM,3PH,60HZ,5010,TEFC,F1

CWM_N NEMA Rated Contactors

Table of Contents. Equipment Summary...3. Performance and Value Vs. New Equipment...3. Reliability.. 3

MaxPak Plus Analog DC V S Drive

LOW-NOISE DIESEL-POWERED AC GENERATOR

GE Energy. Variable Frequency Transformers Grid Inter-tie

Synchronous Generators I. Spring 2013

SE2000BX Static Exciter

ABB n.v Power Quality in LV installations

The Wound-Rotor Induction Motor Part I

34 th Hands-On Relay School

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

Power Systems Trainer

Chapter 3.2: Electric Motors

ADS7 AC Contactor Starters

This webinar brought to you by the Relion product family Advanced protection and control IEDs from ABB

2014 ELECTRICAL TECHNOLOGY

R07 SET - 1

INDUSTRIAL GENERATOR SERVICE

UNIT-I ALTERNATORS PART-A

Principles of iers (intelligent

Welcome. Power Survey International

Synchronous Generators I. EE 340 Spring 2011

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

2 Unit Petrol Engine Spare parts kits for 4 WD Nissan Patrol

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz Data Center Continuous

XQC1600 Power Module POWER MODULE. 50/60Hz Switchable Rating FEATURES REDUCED ENVIRONMENTAL IMPACT SINGLE SOURCE SUPPLIER SOUND-ATTENUATED ENCLOSURE

Legal Name of the Customer (or, if an individual, individual's name): Name: Contact Person: Mailing Address: Physical Address: City: State: Zip Code:

Trouble Shooting Guide EWA, 3-phase (D2422)

SECTION MOTOR CONTROL

TECHNICAL SPECIFICATIONS FOR DIESEL GENERATORS kva (CANOPY TYPE) +15 GENERAL ATS PANELS

Single Phase Induction Motors

Pretest Module 21 Unit 4 Single-Phase Motors

Delomatic 400 GAS CHP controller TCP/IP Modbus communication

HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL

Question Number: 1. (a)

Unit III-Three Phase Induction Motor:

CI-TI Contactors and Motor Starters Type CI 6-50

Alternator as a voltage Generating source and its response to the leading power factor loads

Summary of Revision, IEEE C , Guide for Breaker Failure Protection of Power Circuit Breakers

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

KD LV Motor Protection Relay

PQC - STATCON The ultra fast Power Quality Compensator

Transcription:

Synchronous motor with fluid coupling drive arrangement for a preheater ID Fan presenter Nathan Schachter

SLC PLC Lubrication units Cooling Water DCS SUB BD Breaker SR469 GE STAT-XTOR PLC Field Application Dampers Kiln System Fan Hydraulic Unit REACTOR Shorting Breaker Instrumentation 5000 hp synch motor VOITH FLUID COUPLING Auxiliary Drive Field RTD Windings Differential Protection RTD oil Temp RTD Bearings Surge Protection Pressure TX Vibration Monitors Speed Measurement Leak Detector Internal Air Temperature ROBINSON FAN RTD Bearings Vibration Monitors

SYNCHRONOUS MOTOR VS INDUCTION MOTOR

POWER FACTOR CORRECTION USING SYNCHRONOUS MOTORS G S W Q M P UTILITY Generator SYNCHRONOUS Motor Typical Power Flow in Motor Circuit S: Apparent power kva W: Active power kw Q: Reactive kvar P: Mechanical power kw Efficiency 3-4% Better than induction motors Power Factor compensation with leading power factor

POWER FACTOR IMPROVEMENT USING SYNCHRONOUS MOTOR WITH UNITY or LEADING POWER FACTOR B C Q O S W Φ =0º Φ = 30º D A S = W, Φ=0º, COS Φ = 1 Vector Diagram OA: OB: OC: OF: CD: Φ : OD: AE: S = S Active power W (kw) Capacitive reactive power Q (kvar) Apparent power S (kva) Inductive reactive power Q (kvar) Reactive power compensation Q : (kvar) for unity PF Phase angle compensated New apparent power from utility S at unity PF Equivalent leading PF capacitor bank replaced = 25% of nameplate kva of motor to compensate the balance of plant. Machine kva S = S. F E S =S, Φ=-30º, COS Φ =.8

TWO TYPES OF SYNCHRONOUS MOTORS EXCITERS Slip Ring Brushless Exciters

REACTOR START

BASIC OPERATION FOR ALL EXCITERS Close Breaker - Start Incomplete Sequence Timer Motor Accelerates At 98% Speed Apply Field 5 seconds after Applying Field, Arm Slip Guard Relay. 2 seconds after arming the Slip Guard Relay, energize MSC (Motor Synchronized, Ready to load), to give permission to load motor. This also resets the Incomplete Sequence Timer.

BASIC SLIP RING EXCITER

REVIEW OF SPECIAL OPERATION FUNCTIONS This motor is accelerated with a reactor in series with it. At 98% Motor Speed, the Starting Reactor is switched out. (The Reactor Breaker closed to short out the Reactor). The closing of the Reactor Breaker is controlled by the Stat-x-ator. Wait 2 seconds after the Starting Reactor is out before Field Application. On Normal Stop, open the reactor-shorting breaker when the Start/Run Breaker opens. The opening of the Reactor Breaker is controlled by the Stat-x-ator.

BASIC STAT-X-ATOR PROTECTION ROTOR PROTECTION Field Proving Fault Main Field Thermal Overload (Trip) Hot Start Attempt (Trip) Squirrel Cage Overload (Trip) Slip Guard (Trip) Field Loss (Trip) Incomplete Sequence (Trip) Stall (Trip) Math OK (Trip) Fan Fail (Trip) Not always used High Field Resistance Fault (Trip) Low Field Resistance (Trip) Field Over Current (Trip)

REVIEW OF SPECIAL STAT-X-ATOR PROTECTION Shorting Breaker Failed to Close (Trip) Shorting Breaker Failed to Open (Trip) Shorting Breaker opened while synchronized (Trip) BLOCK START SPECIALS Fault on the Stat-x-ator ( Green No Fault Lamp is off) Shorting Switch is still Closed Hot Rotor (Block Start) System Permissive via PLC

STATOR PROTECTION MULTILIN SR469 microprocessor relay Short circuit Phase differential Overload Temperature stator winding RTDs Over/under voltage Ground fault

REVIEW OF MOTOR MOUNTED COMPONENTS Slip Rings Leak Detector Water Cooling Bearing RTD Inlet Air RTD Stator RTD Surge Arrestors Surge Capacitors Differential CT Vibration Detector

REVIEW OF OIU FUNCTIONS Operator interface unit Key Pad Use Event Log Setting time

REVIEW OF THE EXCITER CONTROL CUBICLE (FIELD VISIT) VIEW OF COMPONENTS Power Bridge Control Card Crow Bar Assembly Watts/Var Transducer DCCT Voltage Transducer Shunt Meter Relay Ground Fault Detector 90/30 PLC OIU

END