EVpack-fuse MEV55 BATTERY PACK FUSES FEATURES & BENEFITS APPLICATIONS

Similar documents
EVpack-fuse MEV100 BATTERY PACK FUSES FEATURES & BENEFITS APPLICATIONS

EVpack-fuse MEV100 BATTERY PACK FUSES FEATURES & BENEFITS APPLICATIONS

EVpack-fuse MEV100 BATTERY PACK FUSES FEATURES & BENEFITS APPLICATIONS

EVpack-fuse MEV70 BATTERY PACK FUSES FEATURES & BENEFITS APPLICATIONS

Special Purpose S P A WORLD OF CIRCUIT PROTECTION UNDER ONE ROOF

HelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC

6.3 mm reverse quick connect

Protistor size 120 gr 750VDC (IEC)

Class T 300 & 600 Volt Fuse Blocks F B 300 & 600V CLASS T FUSE BLOCKS RATINGS: FEATURES/BENEFITS: RECOMMENDED FUSE USAGE: CLIP & CONNECTOR TYPES

Electric vehicle auxiliary fuses 500 Vdc, A

HelioProtection HP15NH3L Photovoltaic fuse-links gpv 1500VDC

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

Open-Style Power Distribution Blocks

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A

Protistor size 70 gr 690VAC (IEC)

Bussmann series NH photovoltaic fuse links

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

Cylindrical fuse-link

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017

INDUSTRIAL CYLINDRICAL FUSE LINKS

fuse-links & fuse holders PHOTOVOLTAIC

NH Solid Blades 690 VAC sizes 000 to 3

FUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS

AF40... AF96 3-pole contactors Technical data

Limitor -G General Purpose Fuses

BUSSMANN. Pre-production and sample electric vehicle power fuses 500 Vdc, A SERIES. Technical Data Effective December 2018.

NH photovoltaic fuse links

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

3 - Protection components Motor circuit-breakers

max pole for t=15 ms

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Modulostar. Motor Branch 400V AC - 690V AC up to 11 kw

Spring Reinforced. 30A & 60A Box. Spring. 30A Screw (R) Spring. 30A Screw. Spring Reinforced. 30A Pressure Plate

Open-Style Power Distribution Blocks

Protistor size 31 ar 690VAC (IEC) / 700VAC (UL)

Cylindrical fuse-link

Electronic Circuit Breaker ESS20-0..

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Low voltage NH knife-blade fuse-links

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Power Distribution Blocks

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

High-voltage high-breaking capacity VV fuse-links

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Surface Mount Fuses 0603Size> Slow Blow> S0603-S-5.0A

HIGH SPEED FUSES AND SYSTEM PROTECTION For Automotive/ Electric Vehicles and EVSE/ Charging Equipment

Motor Protection Circuit Breakers 3VU13 and 3VU16

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

MS General Information Extended Product Type: MS

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

Positive Temperature Coefficient (PTC) Data Sheet

Industrial Contactors CTX 3 3P 185A - 800A

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

Complete and reliable solar circuit protection

XL Photovoltaic fuse links

D509E. Manual Motor - Starters

Semiconductor Fuses European Fuses

onlinecomponents.com

A powerful way to manage your power distribution challenges. I Power Distribution Blocks

User Manual. Solar Charge Controller 3KW

TAE pole Contactors

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

DMX 3 -I 2500 switch disconnectors

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Surface Mount Fuses 0603Size> Slow Blow> S0603-S Series

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Mini contactors B6, BC6 with 3 pole

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

RAPIDPLUS. high speed fuse links for semiconductors

Gears & Fuse Gears. American General Purpose Fuses Cylindrical & Blade Fuse Blocks Class H, K & R CLASS H, K AND R FUSE BLOCKS. Ratings.

R.C.B.O. SP / 1 module

Technical data for manual motor starters Type MS325

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

Semiconductor (AC) fuses

High voltage high-breaking capacity VV fuse-links

TMC 91H is now TMC 60 C Series

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

C E R T I F I C A T E O F C O M P L I A N C E

LINOCUR Size D02 63A 230VAC/440VAC

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Compact NS. Installation recommendations

Metal Alloy Low-Resistance Resistor Specifications

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

MULTIVERT 1000A Main Incomer, 690VAC

Transcription:

EVpack-fuse MEV55 BATTERY FUSES BATTERY PACK FUSES FEATURES & BENEFITS Design for applications Low watt losses High cycling performance Full coverage of battery module and current Ultra compact size Current Ratings (In): 5 to 50A Interrupting Rating (IR): 20kA @ 550V, L/R < 1ms EVpack-fuse line-up belongs to the new Over-Current protection (O.C.P.) range developed by MERSEN to address specific needs in EV/ HEV and Battery Electrical Storage System. EVpack-fuse provides the ultimate protection of the battery pack offering reliable clearing of fault currents. It has been specifically engineered and tested to provide applications best-in-class protection performance: Up to 550V, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA, L/R 1ms, Minimum Breaking Capacity (MBC) < 3kA for a perfect matching with contactor. APPLICATIONS EV/HEV Electrical Energy Storage Battery pack protection Battery Disconnect Unit (BDU) Battery Junction Box for auxiliaries Battery charger Supercapacitor pack protection Backup protection for relay / disconnector / switch Maintenance Safety Disconnect (MSD) STANDARDS Power Cycling & Vibration: JASO D622 IATF - ISO/TS 16949 Quality management undergoing certification EP.MERSEN.COM 1

PRODUCT RANGE MEV55C Ferrule Fuse MEV55C30 current In Power dissipation at 0.5 In Min. breaking capacity (MBC) Max. time to clear MBC MEV55C5 550 V 5 A 0.25 W 10 A 10 s 7.5 g MEV55C6 550 V 6 A 0.29 W 12 A 10 s 7.5 g MEV55C7 550 V 7 A 0.31 W 14 A 10 s 7.5 g MEV55C8 550 V 8 A 0.4 W 16 A 10 s 7.5 g MEV55C10 550 V 10 A 0.45 W 20 A 10 s 7.5 g MEV55C12 550 V 12 A 0.47 W 24 A 10 s 7.5 g MEV55C15 550 V 15 A 0.49 W 30 A 100 s 7.5 g MEV55C20 550 V 20 A 0.56 W 40 A 100 s 7.5 g MEV55C25 550 V 25 A 0.63 W 50 A 100 s 7.5 g MEV55C30 550 V 30 A 0.68 W 60 A 100 s 7.5 g MEV55C30/50 550 V 50 A 1 W 180 A 10 s 7.5 g Weight MEV55C -S Surface Mount Fuse MEV55C15-S MEV55C30-P MEV55C -P PC Board Mount current In current In Power dissipation at 0.5 In Power dissipation at 0.5 In Min. breaking capacity (MBC) Min. breaking capacity (MBC) Max. time to clear MBC MEV55C5-S 550 V 5 A 0.25 W 10 A 10 s 9.9 g MEV55C6-S 550 V 6 A 0.29 W 12 A 10 s 9.9 g MEV55C7-S 550 V 7 A 0.31 W 14 A 10 s 9.9 g MEV55C8-S 550 V 8 A 0.4 W 16 A 10 s 9.9 g MEV55C10-S 550 V 10 A 0.45 W 20 A 10 s 9.9 g MEV55C12-S 550 V 12 A 0.47 W 24 A 10 s 9.9 g MEV55C15-S 550 V 15 A 0.49 W 30 A 100 s 9.9 g MEV55C20-S 550 V 20 A 0.56 W 40 A 100 s 9.9 g MEV55C25-S 550 V 25 A 0.63 W 50 A 100 s 9.9 g MEV55C30-S 550 V 30 A 0.68 W 60 A 100 s 9.9 g MEV55C30/50-S 550 V 50 A 1 W 180 A 10 s 9.9 g Max. time to clear MBC Weight MEV55C5-P 550 V 5 A 0.25 W 10 A 10 s 9.9 g MEV55C6-P 550 V 6 A 0.29 W 12 A 10 s 9.9 g MEV55C7-P 550 V 7 A 0.31 W 14 A 10 s 9.9 g MEV55C8-P 550 V 8 A 0.4 W 16 A 10 s 9.9 g MEV55C10-P 550 V 10 A 0.45 W 20 A 10 s 9.9 g MEV55C12-P 550 V 12 A 0.5 W 24 A 10 s 9.9 g MEV55C15-P 550 V 15 A 0.45 W 30 A 100 s 9.9 g MEV55C20-P 550 V 20 A 0.54 W 40 A 100 s 9.9 g MEV55C25-P 550 V 25 A 0.59 W 50 A 100 s 9.9 g MEV55C30-P 550 V 30 A 0.65 W 60 A 100 s 9.9 g MEV55C30/50-P 550 V 50 A 1.1 W 180 A 10 s 9.9 g Weight EP.MERSEN.COM 2

TIME CURRENT CHARACTERISTIC CURVES MEV55C, -S, -P 100 70 50 30 Prearcing time (s) 20 10 7 5 3 2 1.7.5.3.2 5A 6A 7A 8A 10A 12A 15A 20A 25A 30A 30/50A.1.07.05.03.02.01.007.005.003.002.001 5 7 10 20 30 50 70 100 200 300 500 700 1000 Available Current 1ms Time Constant (A) 2000 3000 5000 7000 10000 EP.MERSEN.COM 3

POWER DISSIPATION MEV55C, -S, -P 6 Correction Factor for Power Dissipation 5 4 3 2 1 0 30 40 50 60 70 80 90 100 % of Current EP.MERSEN.COM 4

TEMPERATURE DERATING MEV55C, -S, -P 1.2 1.1 Derating Coefficient 1.0 0.9 0.8 0.7-30 -20-10 0 10 20 30 40 50 60 70 80 Ambient Temperature C DIMENSIONS MEV55C Ferrule Fuse (5-50A) 38 10.1 10.1 Dimensions in mm 10.3 EP.MERSEN.COM 5

DIMENSIONS MEV55C -S Surface Mount Fuse (5-50A) Dimensions in mm MEV55C -P PC Board Mount (5-50A) Dimensions in mm EP.MERSEN.COM 6

ACCESSORIES Fuse blocks Item Application Fuses Number of poles/ phases Contact Materials Wire Range Tightening torque (recommended) Open-style fuse blocks 30311 30312 Screw w/ double quick connects at both ends 30310 30310 600 V MEV55C fuses up to 30A Adder Tin-plated Copper Cu #10-14 2.3 N-m 30311 30311 600 V MEV55C fuses up to 30A 1 Tin-plated Copper Cu #10-14 2.3 N-m 30312 30312 600 V MEV55C fuses up to 30A 2 Tin-plated Copper Cu #10-14 2.3 N-m 30313 30313 600 V MEV55C fuses up to 30A 3 Tin-plated Copper Cu #10-14 2.3 N-m Pressure plate (sems) w/ double quick connects at both ends 30320 30320 600 V MEV55C fuses up to 30A Adder Tin-plated Copper Cu #10-14 2.3 N-m 30321 30321 600 V MEV55C fuses up to 30A 1 Tin-plated Copper Cu #10-14 2.3 N-m 30322 30322 600 V MEV55C fuses up to 30A 2 Tin-plated Copper Cu #10-14 2.3 N-m 30323 30323 600 V MEV55C fuses up to 30A 3 Tin-plated Copper Cu #10-14 2.3 N-m Copper box 30350 30350 600 V MEV55C fuses up to 30A Adder Tin-plated Copper Cu #6-14 3.9 N-m 30351 30351 600 V MEV55C fuses up to 30A 1 Tin-plated Copper Cu #6-14 3.9 N-m 30352 30352 600 V MEV55C fuses up to 30A 2 Tin-plated Copper Cu #6-14 3.9 N-m 30353 30353 600 V MEV55C fuses up to 30A 3 Tin-plated Copper Cu #6-14 3.9 N-m 30313 30321 30322 30323 EP.MERSEN.COM 7