T O K I S T A R L I G H T I N G I N S T R U C T I O N M A N U A L Advantage Series

Similar documents
High-Performance Servo-Worm Reducers Input and Output Couplings for Servo-Worm Reducers 18. Selection and Ratings for Servo-Worm Reducers 19 22

Pressure Relief Valve Overflow Valve Type DHV 715 Type DHV 716 Type DHV 725

Ø range <500 mm. Ø range >500 mm. Operating conditions. Surface quality. Surface roughness R a R max

O.C. 3 O.C. 12V 24V 4 O.C. 5 5 O.C. 6 6 O.C. Q T Y S L F - L C - M C SPACING MINI JUNCTION BOX CONNECTORS

Deep groove ball bearings

Pipe bracket spacing and support of pipelines

ASV sturdy and robust construction. DN 10 up to DN bar (PN 10) at 20 C. DMV 755: 1,0-9,0 bar DMV 765: 0,5-9,0 bar

Outdoor Installation Using an Electronic LED Power Supply (TE-60L-12)

OPTOTHYRISTOR MODULES OF SINGLE- AND THREE-PHASE RECTIFIER BRIDGES MO20(A), MO21(A), MO22(A), MO23(A), MO24(A) USER S MANUAL

COMPACT BEARING CR 2000

NSK Ball Screws for Standard Stock

OUTPUT CONNECTIONS Bring the wires of the light fixture through the other open knockout and connect them to the power supply output wires.

* * Data sheet NK10... H. Fill Level Limiter. for use in explosive areas Gas explosion protection Zone 1 and 2 Dust explosion zone 21 and 22

*内輪/B126-B128/E_*内輪/B126-B128/E 11/05/25 10:07 ページ 127 Inner Rings

Variable area flowmeter DFM 165 to 350

Unimaster Dust Collectors Series UMA

FP-4000 Series FLOAT LEVEL SWITCH OUTLINE MAIN APPLICATIONS STANDARD SPECIFICATION

Other materials are available on request. Operating conditions

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS

NSK Ball Screws for Standard Stock

E2EM-X4X1 2M * E2EM-X4X2 2M Shielded E2EM-X8X1 2M * E2EM-X8X2 2M. M30 15 mm E2EM-X15C1 2M E2EM-X15C2 2M. M18 16 mm E2EM-X16MX1 2M E2EM-X16MX2 2M

MONORAIL KITS INSTALLATION INSTRUCTIONS SPOTS

Data sheet NK10... U DB_EN_NK10_SIL ST4-C 04/17. Fill Level Limiter. Functional security in compliance with DIN EN * *

ONLITE central CPS. Installation instruction

Data sheet NK10. Fill Level Limiter DB_EN_NK10 ST4-C 04/17 * *

/00 RK 09/2017 EN RIVKLE. Blind rivet nuts and studs

High Performance Linear System Recessed

Industry. SNR : The Bearing Housings

10/2017. Product Catalogue BRONZE BARS AND BEARINGS. Your first choice in bronze

Capillary Thermometers according to DIN Nitrogen Filled Option: Contacts

Split pillow blocks

Tension / Compression tap chucks for tapping cycles that are not synchronized

PRODUCTS FOR THE HYDRAULICS INDUSTRY

Tapping attachments Tap chucks Cutting fluids

Cable protection systems

Tove. High Performance Linear System Perimeter

5 Bearing Preload and Rigidity

Shaft Diameter d 1 3 /16 01 B /4 01 B /16 01 B /2 01 B /16 01E B /4 01E B

E2ER/E2ERZ. Reduce Failures From Cutting Oil Ingress. Features. Applications. Patent Pending Heat-Sealing Method

60.08 Style 233S Restrained Flexible Coupling For Dynamic Joint Deflection

Shyam Enterprises 5 HEAT EXCHANGERS

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Operation Manual. Flathead 80 System

For vertical multi-meter installations 1-6 meter positions Designed to receive watthour meters that meet ANSI C12.10 Overhead or underground feed

QUALITY AND SERVICE DELIVERED WORLDWIDE

140P-2674 AND LATER 175P-4023 AND LATER 250P-2783 AND LATER

New Super Metric Ball Bushing * Bearings Technical Bulletin

Delaware Electric Cooperative Generator Interconnection Application Long Form (For Use with Generators Greater than 25 kw)

Bionic Perimeter Standard C o v e & P e r i m e t e r

Stem Thermometers according to DIN Nitrogen Filled / Optional: Contacts

Triple row axial angular contact ball bearings

Installation Manual. CS9300 Professional Series Landscape Lighting System

Angular contact ball bearings

Assembly Instructions-C70 Amphenol MMCX

1/5. 47-inch Tough LED Display TH-47LFX60W

Information. Plate Cylinder Type C(L)KU32. HIGH type. (Magnetic field resistant auto switch) New. New. New Newly added guide pins

Technical features. Cam followers

COMPANY PROFILE. Our products have been supplied to local and foreign customers for the following industries:

Track Accessories. Single Circuit Track. L Connector T Connector X Connector. Mini Connector Floating Canopy End Feed Kit.

Attachment Chain ATTACHMENT SPACING GUIDE

ISO 9001:2008 LOCKING ASSEMBLIES SHRINK DISCS KEYLESS RIGID COUPLINGS

Micro-Grinder AMERICAN ROTARY TOOLS CO. (ARTCO TOOLS) 250 WEST DUARTE ROAD, #E MONROVIA, CA USA

KUNSTSTOFF-METALL-FORMTEILE CROSSED-ROLLER-SLIM-SPLIT-BEARING. Crossed roller bearing PSX-08. Crossed roller bearing PSX-08 83

Reliable Solutions for Continuous Casters

UCM -04A/06A RoHS compliance

STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

LED FLEXIBLE LINEAR DL-FLEX-UP STATIC SERIES DL-FLEX-UP

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

On the market there are various types of V-belts, among which, the most 'widespread are: by SIT and shown in this catalogue are suitable to be used

Fixed Head Emergency Lights

OUTDOOR TRACK. LABELS Assembled in America

SIT timing pulleys - TOP DRIVE HTD

QUICKSTART GUIDE CHECKED BY

Operation Manual Image

MODULE PROFILES 1 1 2" OC. 5. Mounting - Multiple 2 mounting variations including; 1 2" 1 1 2" REQUIRED POWER SUPPLY 3 8" 3 8"

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

High Pressure Valve Series for Hydrogen Stations

60.07 Style 233 Restrained Flexible Coupling For Dynamic Joint Deflection

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

HKK CURVED JAW COUPLINGS HITEX COUPLINGS

Low Voltage Lighting Power Supplies

ball bearing numbering structure

ROLLER CHAIN SPROCKETS

Specifications LINEAR LED MINI. Series CONTINUOUS LINEAR SUSPENDED SYSTEM. GlowSTX GSA. GSA Ordering Example: GSA-05L-9030-LN-048-BB.

FP-4000 Series FLOAT LEVEL SWITCH OUTLINE MAIN APPLICATIONS STANDARD SPECIFICATION

K12 High Performance Key Switches

CATALOG

Lantern Era Bollard - LE Installation Instructions


Verge Door Frame, 24VDC Plaster-In LED system VGDF-_-_-_

FOR EVERYTHING ENCLOSURE

TNS. Stem Thermometers according to DIN EN nitrogen filled option: contacts. Environmentally-friendly measuring system with non-toxic nitrogen

Mineral Insulated RTD Sensors PTOP

FULL COMPLEMENT NEEDLE BEARINGS

Section 3: Introduction. Dipped Radial Capacitors. Foreword SOLID TANTALUM RESIN DIPPED SERIES TAP/TEP

Tungsten Carbide Burrs

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

INSTRUCTIONS. Power Panel. Installation Instructions

Source: 209.2LM per foot, 2.7W per foot

Transcription:

T O K I S T A R L I G H T I N G I N S T R U C T I O N M A N U A L Avantage Series General escription Tokistar s Avantage Series is a 24 VAC lighting system using LE moules or rigi-loop xenon lamps. LEs are 0.72 watts. Xenon lamps are available at watt, watt, or watt. Xenon lamps have the voltage an rating stampe on the glass at one en. Each Avantage fixture is labele with wattage an operating voltage. The voltage an lamp rating are stampe on one en of the xenon lamps. 24/ Socket Sie View LE Moule Socket Sie View Xenon Lamp escription Light Source Watt Xenon Watt Xenon Watt Xenon 0.72 Watt LE 0.72 Watt LE Watt Cool White Xenon Watt Cool White Xenon Part No. XB-F XB-F XB-8F AVLE-WW AVLE-IW XB-FB XB-8FB Seconary Circuit Limitation The maximum loa of each fixture must not excee 480 Watts (20 amps @ 24 Volts). In aition to this limitation, consieration must be given to the effects of voltage rop. Fixtures with lower wattage lamps (such as LEs) an more istant socket spacing have recommene maximum lengths less than 480 Watts. T Seconary Circuit Limitation Each seconary circuit MUST NOT excee 20 amps (480 watts @ 24VAC) This chart gives recommene maximum lengths which take into account these two limitations. Conforming to these lengths will ensure no fixture excees 480 Watts, an will not be subjecte to excessive voltage rop. Watt/X Watt/X Watt/X8 0.72 Watt/LWW 0.72 Watt/LIW Maximum Lamps/Circuit 160 Lamps 96 Lamps 6 Lamps 400 LEs 400 LEs Lamp Spacing 2.4 O.C. (60 mm) O.C. (7 mm) 4 O.C. (100 mm) 6 O.C. (10 mm) 2 (9.6 M) 40 (12 M) 48 (14.4 M) 60 (18 M) 19 (.76 M) 24 (7.2 M) 2 (9.6 M) 48 (14.4 M) Maximum Run Lengths 11 (.6 M) 14 (4.2 M) 18 (.6 M) 28 (8.4 M) 80 (24 M) 100 (0 M) 1 (40 M) 200 (60 M) 80 (24 M) 100 (0 M) 1 (40 M) 200 (60 M) 1. Rea all instructions completely before beginning installation. 2. Turn off electricity before beginning installation.. All wiring is to be performe by a qualifie electrician. 4. Installation must comply with the National Electrical Coe, an all applicable coes.. Turn main supply to transformer on only after all connections are mae an teste. 6. Use only transformers provie by Tokistar with the system. TOKISTAR LIGHTING 101 E. iscovery Lane Anaheim, CA 92801 TEL: 714 772 700 FAX: 714 772 7014 email: info@tokistar.com Website: tokistar.com

Avantage Instructions Page 2 Step 1: Mounting Fixtures Option 1 - irect Screw Mounting (Part# AV-MS) Each LE or lamp socket, has four mounting holes esigne to accept screws. For secure mounting, use two screws in opposing holes. Sockets must be firmly attache to support the weight of the fixture., 4 an 6 socket spacing Seamless Light Avantage fixtures are flexible enough to turn corners without the use of special harware, eliminating ark spots at corner locations. 2.4 socket spacing Option 2 - Mounting Channel (Part# AV-MC) An optional mounting channel may have been provie with your materials. Screw the channel securely in place, then snap each socket into the channel. Attach screws every 8. Option 2A - Channel Clamps (Part# AV-CL) These clamps are for use with our AV-MC Mounting Channel. Screw the clamps securely in place, then snap in the channel. Attach clamps every 8. Attach screws every 8 Mounting Channel conforms to a 24 insie or outsie raius. Channel Clamp En Caps - Part# EC-WH (White) / Part# EC-BK (Black) Ens caps are attache to the en of each Avantage lighting fixture. If the fixture nees to be trimme, a new en cap nees to be attache to the en of the fixture after trimming. En Cap / Heat Consieration Xenon lamps prouce heat an will cause amage if they come in irect contact with persons or combustible materials. In accorance with NEC/NFPA 70 Article 410.11, combustible materials next to fixtures must not be subjecte to temperatures in excess of 90º C (194º F). In orer to conform to this stanar, fixtures nee to be installe accoring to the minimum space requirements shown below. 1 1 2 2 With Reflector 2.4 O.C. Watts Watts 4 Watts 1 2 1 2.. Watts 1 2 1.2 2

Avantage Instructions Page Step 2: Installing Reflectors/LEs/Lamps Installing Reflectors - Part # AVWH-REF-S (White) / Part #: AVBK-REF-S (Black) Part# AVWH-REF-A (White) / Part# AVBK-REF-A (Black) Your fixture may have been provie with optional reflectors. Symmetrical reflectors (#AVWH/BK-REF-S) must be attache before lamps are installe. Push the plastic reflector base irectly over the socket until it is firmly seate in place. Asymmetrical reflectors (#AVWH/BK-REF-A) may be attache after lamps or LEs have been installe. Silver Reflector Plastic Reflector Base Avantage Socket Installing LEs or Lamps 24/ LAMP 24/ LAMP SOCKET SOCKET 1. Push LE or Lamp into one sie of socket at an angle. 2. Push other sie of LE or Lamp straight own. o Not Twist. Lamp Replacement 1. Remove lamps from socket by pulling irectly out (o Not Twist). 2. Replace lamps only with the same or lower wattage lamp. Installing Clear Lens - Part# AV-LNS Your fixture may have been provie with clear lens covers. Push the lens irectly over the top of the socket. When properly seate between the two catches on the sie of the socket, the lens will be securely fastene an not move from sie to sie. Clear Lens En View EN VIEW FOR SHIEL Catches secure Clear Lens in place. SIE VIEW o not use the Watt lamp (part# XB-8F), or cool white xenon lamps (part# s XB-FB & XB-8FB) with the Lens Cover.

Avantage Instructions Page 4 Step : Seconary Wiring Mini Junction Box Connectors - Part# AV-JBOX If installation involves running wire through a builing structure, conuit may be require to fee the fixture. A miniature junction box is available with a 1/Ø knockout for use with conuit fittings. The terminal block insie the junction box accepts 14-8 AWG wire. All seconary circuit wiring must conform to the National Electrical Coe an all applicable coes. Remove AV-JBOX Cover Screw AV-JBOX firmly in place Install Strain-Relief Maximum 480 Watts (20 Amps) per connection AV-CONN insie AV-JBOX Terminal Block Connectors - Part# AV-CONN Avantage Series fixtures may have been provie with terminal block connectors. One en of this connector screws irectly to the Avantage fixture, an the other en accepts 14-8 AWG wire. A screw hole is provie in the center of the connector for secure mounting. AV-CONN Terminal Block T-Connection System - Part# AV-TCON Our T-Connection system can fee multiple fixtures from a single wiring harness. Female connectors are attache to the main harness at any interval an the mating male connectors attach to each en of the fixture. T-Connector When attaching wire to terminals, make certain the insulation is strippe an the connection is mae so no live conuctors are expose. Live conuctor must be within connector housing

Avantage Instructions Page Step 4: Instructions Location The maximum recommene istance between the fixture an the transformer varies, base upon the loa of each fixture an the size of seconary wire feeing the fixture. It is impossible to give a efinitive istance without consiering all the variables. Electrical engineers an contractors can calculate these istances. Shoul you nee guiance, consult the factory. Larger capacity transformers with multiple outputs can be centrally locate an fee fixtures in either irection. Input Voltage o not excee maximum fixture length o not excee transformer output rating Seconary Circuit Protection s are provie with circuit breakers to protect seconary circuits. The maximum size circuit breaker on a transformer is 2 amps, but the circuit wire to the breaker MUST NOT EXCEE 20 AMPS. There are several transformer sizes available, an ifferent size breakers installe in them. Below is a selection of transformers with their respective circuit limitations. 1000 Watt 960 Watts Max. 00 Watt 1 A Max. Loa 12. Amps 00 Watts @ 24 VAC 70 Watt 70 Watts Max. 20 Watt 1 A Max. Loa 10.4 Amps 20 Watts @ 24 VAC 00 Watt 480 Watts Max. 100 Watt 7 A Max. Loa 4.1 Amps 100 Watts @ 24 VAC s shoul be installe in an accessible location. Magnetic transformers generate heat an must be installe in locations where there is free-air circulation. Electronic transformers require less space to issipate heat, but they too shoul be installe in accessible locations with free-air circulation. For aitional information, please refer to the instruction manual provie with your transformer. Version 1.0