General Purpose US Fuses

Similar documents
Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...

For Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses

UL/CSA Listed Power Fuses P F THE MOST POPULAR UL/CSA LISTED POWER FUSES TO MEET THE MOST POPULAR PROTECTION PRIORITIES

North American Power Fuses

North American Power Fuses

Low-Peak 600V Class RK1

YOUR ELECTRICAL SYSTEM IS YOUR LIFELINE AMP-TRAP 2000 FUSES

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

Low Voltage Fuses For Motor Protection

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

UL248 North American Low Voltage Fuses

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

Application Information Need to know how? You ve turned to the right place...literally.

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

FUSES 8.1. Questions? Answers at Western US: CED-ELEV

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

N0N A 250V One-Time Class H Fuse

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

E-RATED/MEDIUM VOLTAGE FUSES

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

British BS 88 Fuses. High Speed Fuses. Introduction. General Information

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

Accessories. For product data sheets, visit

TELECOMMUNICATIONS SPECIAL PURPOSE FUSES

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

PROTECTION AND CONTROL

V217276J /2 ATDR4-1/2 Z217786J 10 5 ATDR5 K218302J 10 6/10 ATDR5-6/10 Z218821J 10 6 ATDR6

Special Purpose Fuses

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Low voltage, branch circuit fuses

Low Voltage, Branch Circuit Rated Fuses

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

Fuseology. Dual-Element, Time-Delay Fuse Operation

Fused Coordination Panelboard

Bussmann. Circuit Protection Solutions

Control Circuit Protection

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

Bulletin 1489 Circuit Breakers. Selection Guide

XT IEC Power Control Manual Motor Protectors

1492-CB 1492-GH 1492-GS

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

Medium Voltage Metal-Enclosed Switches

PD-Series Ground Fault Circuit Protection

PSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES

C E R T I F I C A T E O F C O M P L I A N C E

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

MAGNETIC MOTOR STARTERS

Miniature Circuit Breakers

Midget & Electronic Fuses

Ferrule fuses. High Speed Fuses

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Motor Protection. Presented By. Scott Peele PE

SECTION MOTOR CONTROL

Industrial Control Transformers

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Quik-Spec Coordination Panelboard Specifications

Secondaries. arc flash note Introduction. By Mike Lang, engineer and. Services Supervisor

Horizontal Circuit Switchers

DETAIL SPECIFICATION SHEET

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

OVERALL LENGTH (B) " ( mm) " ( mm) " ( mm) " ( mm)

ECET Distribution System Protection. Overcurrent Protection

209 Series. Magnetic Circuit Protectors

MOLDED CASE CIRCUIT BREAKER BASICS. David Castor, P.E.

High Speed Fuses. Section Contents Page

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

Design Standards NEMA

TMC 91H is now TMC 60 C Series

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Series L9 UL-489 Miniature Circuit Breakers

Selective Coordination

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Mica Element Support. Compacted Quartz Sand. Length B

Medium Voltage Metal-Enclosed Switches

Engineering Dependable Protection

Compact Circuit Protector (CCP) Application Note

www. ElectricalPartManuals. com Engineering Dependable Protection

A. Submit manufacturer's literature and technical data before starting work.

C E R T I F I C A T E O F C O M P L I A N C E

G-Series. Circuit Breaker.

JARD by MARS JARD by MARS

moog MSD Servo Drive UL-Certification MSD Servo Drive product range

Protistor size 70 gr 690VAC (IEC)

CUBEFuse. CUBEFuse catalog numbers (amps)

JOSLYN CLARK VACUUM CONTACTORS

Medium voltage fuses Medium voltage fuses

Transcription:

SMARTSPOT with Maximum circuit protection Amp-trap 2000 SmartSpot AJT fuses now provide a visual open fuse indicator. With advanced material technology added to the existing product line the AJT fuse provides IEC Type 2 (No Damage) protection to main, feeder, and branch circuits, for all types of loads yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT s time delay characteristics for handling typical in-rush currents, its current limiting ability. Features /Benefits Solid State SmartSpot Indicator Time delay for motor starting and transformer inrush 300kA interrupting rating - self-certified, UL witnessed tests Extremely current limiting for low peak let-thru current Most current limiting UL class fuse Small footprint requires less mounting space and allows smaller, more economical fuse blocks Easy 2-to-1 selectivity for prevention of nuisance shutdowns Unique Class J dimensions prevent replacement errors High-visibility orange label gives instant recognition Metal-embossed date and catalog number for traceability and lasting identification Fiberglass body provides dimensional stability in harsh industrial settings High-grade silica filler ensures fast arc quenching Optional EI Indicator/Switch mount for AJT70 to 600 open fuse indication Ratings AC: 1 to 600A 600VAC, 200kA I.R. (self certified for 600VAC, 300kA I.R.,UL witnessed) DC: 1 to 600A 500VDC, 100kA I.R. Highlights Smart Spot Indicator Time Delay Highly Current Limiting DC Ratings Optional Mechanical Indicator (70 to 600A fuses) Applications Motor Circuits Mains Feeders Branch Circuits Lighting, Heating and General Loads Transformers Control Panels Circuit Breaker Back-up Bus Duct Load Centers Approvals AJT (1-600): UL Listed to Standard 248-8 DC Listed to UL Standard 198L CSA Certified to Standard C22.2 No. 248.8 IEC 269-2-1 AJT (70-600) EI: UL Component Recognized DC Tested to UL Standard 198L GPUS1

Standard Fuse Ampere Ratings, Catalog Numbers and Ref Numbers Ampere Catalog Reference Ampere Catalog Reference Rating Number Number Rating Number Number 1 AJT1 X214748 1-1/4 AJT1-1/4 C215765 1-1/2 AJT1-1/2 B215258 1-6/10 AJT1-6/10 G216275 1-8/10 AJT1-8/10 H216782 2 AJT2 P219364 2-1/4 AJT2-1/4 A200882 2-1/2 AJT2-1/2 T223094 2-8/10 AJT2-8/10 M201422 3 AJT3 Q211683 3-2/10 AJT3-2/10 L212714 3-1/2 AJT3-1/2 W212194 4 AJT4 W214241 4-1/2 AJT4-1/2 Y214749 5 AJT5 H216276 5-6/10 AJT5-6/10 J216783 6 AJT6 D217813 6-1/4 AJT6-1/4 P218329 7 AJT7 Q219365 8 AJT8 M219891 9 AJT9 D222574 10 AJT10 Y217302 12 AJT12 C217812 15 AJT15 N218328 17-1/2 AJT17-1/2 A218845 20 AJT20 Z201939 *For optional indicator/switch mount add EI. For Example: AJT100EI.See table below Note: Indicator not available for rating 1A to 7A. 25 AJT25 X211160 30 AJT30 W213229 35 AJT35 M213727 40 AJT40 C215259 45 AJT45 D215766 50 AJT50 Z217303 60 AJT60 B218846 70 AJT70* L201421* 80 AJT80* W211159* 90 AJT90* V212193* 100 AJT100* B215764* 110 AJT110* F216780* 125 AJT125* A217810* 150 AJT150* Y218843* 175 AJT175* K219889* 200 AJT200* Y200880* 225 AJT225* V211158* 250 AJT250* K212713* 300 AJT300* L213726* 350 AJT350* W214747* 400 AJT400* G216781* 450 AJT450* M218327* 500 AJT500* N219363* 600 AJT600* C222573* Recommended Fuse Blocks With Box Connectors for Amp-trap Class J Fuses Fuse 600V OR LESS Ampere 1 Pole 3 pole Rating Catalog Number Reference Number Catalog Number Reference Number 0-30 US3J1I M212922 US3J3I K214967 31-60 US6J1I F222047 US6J3I M211381 61-100 61036J Z201640 61038J G212917 101-200 62001J D214455 62003J E214962 201-400 64031J X218543 64033J S219068 401-600 6631J P201125 6633J A201641 A variety of pole configurations and termination provisions is available. GPUS2

Dimensions AMPERE A B C D E F G H RATING In. mm In. mm In. mm In. mm In. mm In. mm In. mm In. mm 1-30 2-1/4 57 13/16 21 - - - - - - - - - - - - 31-60 2-3/8 60 1-1/16 27 - - - - - - - - - - - - 61-100 4-5/8 117 1-1/8 29 1/8 3.2 3/4 19 1 25 3-5/8 92 3/8 10 9/32 7 101-200 5-3/4 146 1-5/8 41 3/16 4.8 1-1/8 29 1-3/8 35 4-3/8 111 3/8 10 9/32 7 201-400 7-1/8 181 2-1/8 54 1/4 6.3 1-5/8 41 1-7/8 48 5-1/4 133 17/32 14 13/32 10 401-600 8 203 2-1/2 64 3/8 9.5 2 51 2-1/8 54 6 152 11/16 18 17/32 13 1-60A 70-600A Optional Indicator/Microswitch Mount (EI) dimensions: Note: Fuses with the EI option will receive the AOS-S or AOS-Q Add-On-Switch whiech is ordered reparately. Catalog Reference A Number Number AJT70EI Y201938 AJT80EI P211682 2.80 AJT90EI V214240 (71.0) AJT100EI F216274 AJT110EI W217300 AJT125EI L218326 3.22 AJT150EI M219362 (81.8) AJT175EI R223092 AJT200EI K201420 AJT225EI N211681 AJT250EI V213228 3.24 AJT300EI T214239 (82.2) AJT350EI A215257 AJT400EI X217301 AJT450EI Z218844 3.61 AJT500EI L219890 (91.8) AJT600EI S223093 GPUS3

AJT 1 to 600 MAXIMUM INSTANTANEOUS PEAK LET-THRU AMPERES MELTING TIME CURRENT DATA, 600V FUSES CURRENT IN AMPERES TIME IN SECONDS Peak Let-Thru Current Data AJT 30 to 600, 600 Volts AC AVAILABLE CURRENT IN RMS SYMMETRICAL AMPERES 230 Volt Three Phase Class J AJT Fuses at 230V 2 sec. 5 sec. Over 5 sec. 1/2 2.2 3 3-1/2 4 3/4 3.2 4 5 6 1 4.2 5 6-1/4 8 1-1/2 6 8 9 10 2 6.8 8 10 12 3 9.6 12 15 17-1/2 5 15.2 20 25 30 7-1/2 22 30 35 40 10 28 35 40 50 15 42 50 60 80 20 54 70 80 100 25 68 80 100 125 30 80 100 125 150 40 104 125 150 200 50 130 175 200 250 60 154 200 225 300 75 192 250 300 350 100 248 300 350 450 125 312 400 450 600 150 360 450 500 600 200 480 600 - - GPUS4

380 Volt Three Phase Class J AJT Fuses at 380V 2 sec. 5 sec. Over 5 sec. 1/2 1.3 1-6/10 2 2-1/4 3/4 1.9 2-1/2 2-8/10 3-1/2 1 2.5 3-2/10 4 4-1/2 1-1/2 3.6 4-1/2 5-6/10 6 2 4.1 5 6 7 3 5.8 8 8 10 5 9.2 12 15 17-1/2 7-1/2 13.3 17-1/2 20 25 10 17 20 25 30 15 25 30 40 45 20 33 40 50 60 25 41 50 60 70 30 48 60 80 90 40 68 80 100 125 50 79 90 125 150 60 93 110 150 175 75 116 150 175 200 100 150 175 225 250 125 189 250 300 350 150 218 300 350 400 200 291 350 450 500 460 Volt Three Phase Class J AJT Fuses at 460V 2 sec. 5 sec. Over 5 sec. 1/2 1.1 1-1/2 1-6/10 2 3/4 1.6 2 2-1/4 3 1 2.1 2-1/2 3-2/10 4 1-1/2 3 3-1/2 4-1/2 5-6/10 2 3.4 4 5 6 3 4.8 6 8 9 5 7.6 10 12 15 7-1/2 11 15 15 20 10 14 17-1/2 20 25 15 21 25 30 40 20 27 35 40 50 25 34 40 50 60 30 40 50 60 70 40 52 70 80 90 50 65 80 100 125 60 77 100 125 150 75 96 125 150 175 100 124 175 200 250 125 156 200 225 300 150 180 225 250 350 200 240 300 350 450 250 302 400 450 600 300 361 450 600-575 Volt Three Phase Class J AJT Fuses at 575V 2 sec. 5 sec. Over 5 sec. 1/2.9 1-1/4 1-1/2 1-6/10 3/4 1.3 1-6/10 2 1-1/2 1 1.7 2-1/4 2-1/2 3 1-1/2 2.4 3 3-1/2 4-1/2 2 2.7 3-2/10 4 5 3 3.9 5 6 7 5 6.1 8 9 12 7-1/2 9 12 15 17-1/2 10 11 15 17-1/2 20 15 17 20 25 30 20 22 30 35 35 25 27 35 40 50 30 32 40 50 60 40 41 50 60 70 50 52 70 80 90 60 62 80 90 110 75 77 100 125 150 100 99 125 150 175 125 125 150 200 225 150 144 175 225 250 200 192 250 300 350 250 240 300 350 400 300 289 350 450 500 Minimum - Minimum sizing may not be heavy enough for motors with code letter G or higher. Typical - Suggested for most applications. Will coordinate with NEMA Class 20 overload relays. Suitable for motor acceleration times up to 5 seconds. Heavy Load - In accordance with Table 430-152. If this fuse is not sufficient to start the load, it may be increased to a maximum of 225% of fullload amperes (430-52 Exc. 2b). Use this column for Design E Motors. GPUS5