FA1 Series Air Filtration System. Operations Manual

Similar documents
MODEL FA1 Mini Air Filtration System. Operations Manual

MODEL GS1-100 Air Filtration System. Operations Manual

MODEL FA5 Air Filtration System. Operations Manual

KenkoAir_Purifier manual ENG-FR_FDA 10/12_Air Filter manual 8/15/13 10:44 AM Page 1 OPERATING MANUAL

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

Miracle State Of The Art Air Filtration System!

AIR CLEANERS Model MC 3000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference.

AIR CLEANERS. Model MX 6000 OWNER S MANUAL CAUTION. Read complete instructions before operating. Please file for future reference.

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

MODEL MC1500 Installation and Operation Manual Important:

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BTX-208. Fume Extraction System _B

EXT DUCTLESS FUME HOOD

X-3400A, X-3500, X-3700 OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

Loctite Air Filtration System Part Number EQUIPMENT. Operation Manual

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

OmniAire Portable Air Cleaner OA1200PAC

SPH General Manual 400 Series

Portable Air Purifiers

Videojet Fume Extractor Preventive Maintenance Guide

MODEL SCA Installation and Operation Manual Important:

HEPA AIR FILTRATION SYSTEM

MC2500. Installation and Operation Manual

MODEL MA4210 Installation and Operation Manual Important:

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

Table of Contents. Safety Information Main Functions Set-Up Operation Maintenance Troubleshooting Specifications Customer Support Warranty Information

EXT HEPA/CARBON FUME HOOD

Portable HEPA System


User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

MODEL SAFETY & INSTRUCTION MANUAL

SPECIAL REVERSE HORIZONTAL FLOW ENCLOSURE OPERATING AND MAINTENANCE MANUAL. Issue No: 1

AMAIRCARE HEPA BYPASS AIR FILTRATION SYSTEM READ AND SAVE THESE INSTRUCTIONS! AIR CLEANERS/ FILTERS. Rules for Safe Installation and Operation

Quest H5. Quest Dry. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. Quest H5:

Omniaire 1000V Instruction Manual-8/05

Installation & Service Manual for Portable Fume Collector. Model PFC-800

User Manual. Model: FSL300 Dual Port Laser Fume Extractor

LABORATORY ZERO AIR GENERATOR MODEL N-GC1500 USER S MANUAL

AIR CLEANERS. Model MX 1800 OWNER S MANUAL CAUTION. Read complete instructions before operating. Please file for future reference.

I-6500 Series. Industrial Applications. Operations & Maintenance Manual. Air Purifiers for. Manufactured. Serial number.

X100P Load Bank. Read all instructions before using the load bank. Contents

Owner s Manual Phoenix GuardianR

Operating Manual PFB-2500

PLANNING THE INSTALLATION

XS500 Load Bank. Read all instructions before using the load bank. Contents

Operating Manual MAC-21 VFD

User s Manual and Operating Instructions

OWNER S MANUAL C O M M E R C I A L I N D O O R A I R Q U A L I T Y S O L U T I O N S. Total High Efficiency Particulate & Gaseous Filtration System

Operations and Service Manual. XE400D-SB Load Bank

Portable filtration unit / 650 CFM (305 L/s) Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration

XS400 Load Bank. Read all instructions before using the load bank. Contents

OWNER S MANUAL MODEL FSHEPA375 WHOLE-HOUSE TRUE HEPA AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

Model Numbers: MAC-36-BDF, MAC-42-BDF, MAC-48-BDF CONSUMER: READ AND SAVE THESE INSTRUCTIONS

Powerful. Efficient. RED. Look to Micro Air Dust Collectors for clean air and cost-effective operation.

Fume Extraction Planning Guide

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing

Model G14SD Vapor Management System

INSTRUCTION MANUAL. Abatement Technologies, Inc./Remediation Products Division. Abatement Technologies, Inc. Georgia, USA

Multistage Air Filtration Systems Instruction Manual

Airistar 100GT Owner s Manual Airistar 100GT Air Purifier

OmniAire Omnitec Design, Manufacturing Air Purification Equipment Since 1988

MICRO-AIR AIR CLEANER INSTALLATION AND OPERATION MANUAL. MX3510 Includes Installation, Operation, and Service Instructions CAUTION

Model 6275RC 50% Duty Cycle Compressor

Quick-Start Operating Guide Document No Universal Hood Copyright 2010 Terra Universal Inc. All rights reserved. Revised September 2010

GSL Electronics Modified Sine Wave Power Inverters

SUPERIOR PERFORMANCE

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

HEPA-AIRE PORTABLE AIR SCRUBBER-PAS1800 INSTRUCTION MANUAL

MOBILE FILTRATION FUME CABINET

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BVX-100. Fume Extraction System _B

Source Capture Air Purification System

Air Bear Supreme and Air Bear Cub. Media Air Cleaners READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

CA111 (Series 1,2,3) In Ceiling Media Air Cleaner

Ceiling Mount Source Capture Air Purification System

6300 Series Owner/Operator Manual

Owner's Manual. Model RP Series Power-Vac

Air Boss M-Series Media & Adsorption Air Cleaner

Operations and Service Manual. X30208 Load Bank

Operating Instructions. International English. CCS Dust Extractor

Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual

Air Bear Right Angle. Media Air Cleaner READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

After installing the HEPA filters the discharge air should be monitored to ensure proper filtering efficiency. HEPA Filters

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

PHOENIX GUARDIAN H. E. P. A. SYSTEM

SPH-400 i Series General Manual

DUST COLLECTORS. Stronger. Better. CLEANER.

Comply with the above specifications? Yes No

Owner s Manual Phoenix Guardian HEPA System

OWNER S MANUAL. Installation and Service Manual

Powered Air Purifying Respirator (PAPR) For Departments that Store, Supply and Maintain PAPR Units

PS1201A00, PS1202A00 and PS2401A00 Replacement Power Supplies for Electronic Air Cleaners

Quest DRY 150. Quest PowerHEPA 500. quest. Read and Save These Instructions. Quest PowerHEPA 500:

OL100 VENTILATED DUMP STATION REFERENCE MANUAL. TM Coolidge Hwy. Oak Park, Michigan

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

OmniAire 600N Operations and Maintenance Manual

INSTRUCTION MANUAL D ABATEMENT TECHNOLOGIES, INC. U.S. PATENT D CANADIAN PATENT Abatement Technologies, Inc.

Transcription:

FA1 Series Air Filtration System Operations Manual READ AND SAVE THESE INSTRUCTIONS WARNING: Disconnect from power supply before performing maintenance procedures such as cabinet cleaning, changing filters or servicing of electric motor or other electric components WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device. WARNING: For general ventilating use only. Do not use to exhaust hazardous or explosive materials or vapors. CAUTION: Do not operate without having all filters in place. Do not operate any fan with a damaged cord or plug. Discard fan or return to an authorized service facility for examination and/or repair. Do not run cord under carpeting. Do not cover cord with throw rugs, runners or similar coverings. Arrange cord away from traffic area and where it will not be tripped over.

GETTING STARTED I n i t i a l s e t - up 1. Open all cartons & locate inlet, hose, hose clamps and wheels. 2. Remove ALL filters & packing materials from cartons and the FA1 cabinet 3. Place the FA1 on its side & install wheels in bottom plate 4. Install the inlet to the top of the lid. 5. Remove plastic wrap from gas/odor filter (Part # FA101D or FA201D). 6. Carefully remove perforated cardboard from top and bottom of filter to expose Green filter media. 7. Place gas/odor filter into bottom of cabinet note direction of airflow arrow 8. Place HEPA filter (Part # FA100 or FA100-2) on top of gas/odor filter note airflow arrow 9. Place the pre-filter (Part # FA102B) on top of the HEPA filter. 10. Close and latch the lid. 11. Attach power cord rear of cabinet. L o c a t i n g t h e a i r c l e a n e r : Placing the FA1 as close as possible to the pollution source reduces the amount of hose or duct needed, reduces back-pressure, lowers power consumption and improves overall performance. I n l e t h o s e a t t a c h m e n t : The FA1 ships standard with a 1 x 2, 2 x 2 or 1 x 3 inlet. Attach flex hose over the metal air inlet tube and tighten securely with the stainless steel clamp. Connect the hose to a Fumex suction hood or place as close as possible to the pollution source. E l e c t r i c p o w e r FA1 Series is manufactured with a universal blower/motor assembly (90-250/1/50-60). Default power cord/plug is US (120v). Contact Fumex for additional information or options. Confirm that correct power supply is available. 2

CONTROLS On/Off Switch Simple one touch controls The green light indicating blower speed will confirm power to the unit. Blower/Fan The FA1 utilizes a variable speed blower with three speed settings. Press the fan button to increase/decrease blower speed. Green light will indicate current speed setting. A flashing green light indicates a blower failure. To reset thermal protection disconnect unit from power source and restart. If light continues to flash contact Fumex Inc. for replacement information. Filter monitoring The FA1 utilizes a pressure differential switch to monitor the status of the particulate filters (3). The system monitors across all filters simultaneously and the Orange Change Filter light will flash when a filter(s) needs to be replaced. The recommended procedure is to first replace the pre-filter (Part# FA102B) - if light continues to flash then replace the HEPA filter. (NOTE: For heavy dust applications the polyester prefilter (part# FA103 located inside the FA102B) can be changed individually or use the FA102B-4 large capacity pre-filter)) The FA1 contains a VOC indicator to detect odors/gases in the exhaust stream. When the gas/odor filter becomes saturated (breakthrough occurs) the Change Gas Filter warning light will flash. (At initial startup or when power is disconnected the Change Gas Filter light will blink for a short period of time as the voc sensor calibrates.) GENERAL FILTER CARE Fumex FA1 air purifiers feature a multi-stage filtration system designed to remove a wide range of pollutants from the process plume in an extremely efficient, cost-effective manner. The sytem utilizes a pressure differential switch to indicate a blocked / clogged filter. Once the warning light flashes, filters should be checked and clogged filters replaced. S T A N D A R D F I L T E R S : Part # FA102B Pre-filter Assembly The pre-filter assembly is the first stage in the filtration process. The assembly is composed of high capacity merv 11 rated filter media protected by polyester pre-filter. Unique design minimizes operator/maintenance personnel exposure to contaminants. Replacement: The unique design of the pre-filter allows the filter to be changed as a complete unit or in heavy dust applications the polyester pre-filter can be removed independently. Contact Fumex Inc. regarding any questions/assistance. Part # FA100 or FA100-2 HEPA Filter The HEPA filter is 99.97% efficient in removing particles as small as 0.3 from an airstream. Particles of this size are respirable and can cause significant respiratory problems. 3

Replacement: A HEPA s service life is determined by the volume of sub-micron particles remaining in the airstream after passing through the pre-filters. When properly protected, and depending on loading, HEPA filters often provide months of service. Average service life is 2-4 months. Part # FA101D or FA201D Gas/Odor Filter Most process plumes contain several gases, some odorous some not, some toxic at elevated concentrations some completely harmless regardless of concentration. To ensure employee safety the type and concentration of pollutants must be determined. Please contact Fumex Engineering for selection assistance. For high odor applications contact Fumex for additional options. The FA1 utilizes a blended activated carbon and activated alumina impregnated with KMnO4 filter to capture and treat gases/odors. This combination of materials provides protection across a broad range of gases commonly found in industrial manufacturing processes. G E N E R A L M A I N T E N A N C E 1) The blower motor is a sealed unit, 24,000 hr. MTBF rated. It is permanently lubricated and does not require oiling keep it free of dust accumulations to prevent overheating. 2) Remove any loose accumulations of dust/debris from the air filter chamber periodically. This product employs overload protection (fuse). A blown fuse indicates an overload or short-circuit situation. If the fuse blows, unplug the product from the outlet. Replace the fuse as per the user servicing instructions (follow product marking for proper fuse rating) and check the product. If the replacement fuse blows, a short circuit may be present and the product should be discarded or returned to an authorized service facility for examination and/or repair Remote Start/Stop The FA1 can be supplied with an optional remote start feature Part # FA228. If this option is factory installed on your unit, simply provide 24v to the red wire and the black wire is common. The unit will start when the signal is applied and turn-off when signal is removed. WARNING Connect Remote Starter Cable to 24v, Class 2 Power Supply Only WARNING Disconnect From All Power Supplies before Servicing 4

R e p l a c e m e n t P a r t s P a r t # I t e m P a r t # I t e m C a b i n e t r y E l e c t r i c a l FA108 Wheels, standard FAAU500 Universal blower motor / assembly 90-250/1/50-60 FA109 Vibration Isolators FA117 Cabinet latch FA003 Control board assembly FA118 Cabinet hinge FA114 Fuse, 10 amp FA106A Flanged air inlet 3 FA115 Cordset (120vac) FA106B Flanged air inlet 2 x 2 FA115B Cordset (230vac) FA106C Flanged air inlet 1 x 2 FA113 Fuseholder F i l t e r s G a s / O d o r F i l t e r s FA102B Pre-Filter FA101D Blended carbon media 2 FA103 Polyester pre-filter ( optional) FA201D Blended carbon media 6 FA100-2 HEPA Filter FA100 HEPA Filter W a r r a n t y a n d L i a b i l i t y l i m i t a t i o n s : Fumex FA1 air cleaners are guaranteed for 24 months from date of invoice to be electrically and mechanically sound. This warranty covers the material and workmanship only. Any defective item will be repaired or replaced, at our option, free of charge provided it has not been misused, abused, or otherwise damaged and is returned PREPAID to: Fumex, Inc. 1150 Cobb International Pl., Kennesaw, GA 30152 There are no warranties which extend beyond the descriptions set forth in this warranty, notwithstanding any knowledge of Fumex, Inc. regarding the use or uses intended to be made of goods, proposed changes or additions to goods, or any assistance or suggestions that may have been made by Fumex personnel. Customer is responsible for determining the suitability of Fumex products for customer s use or resale, or for incorporating them into objects or applications which customer designs, assembles, constructs or manufactures. Fumex reserves the right to discontinue any item and to make changes in the specifications, terms and conditions or prices at any time without prior notice. Information furnished in the specifications is believed to be accurate and reliable at time of printing, however Fumex accepts no responsibility for product use, or the effect of future design or specification changes. For Assistance or Technical Support please Contact Fumex Inc. phone 770-514-7907 fax 770-514-1547 USA toll-free 800-432-7550 www.fumexinc.com Fumex, Inc. 1150 Cobb International Place Kennesaw, GA USA 30152 5 Fumex, Inc., 2017, all rights reserved. Specifications subject to change without notice

FA1 UNIT 90-250/1/50-60 W MOTOR W F W U S E PLUG CONN #3 CONN #2 CONTROL PANEL CONN #1 POS NEG LEGEND W WHITE 1 REMOTE START CONECTOR 2 THREE PIN CONNECTOR 3 FIVE PIN CONNECTOR 6

RELAY ACTIVATION PROCEDURES FOR FA1 UNITS 1. Remove all power sources from FA1 unit 2. Locate eight screws securing cabinet bottom panel 3. Remove all and gently pry bottom panel loose CAUTION Do not work on panel with power applied Relay activation jumper 24 volt start connector 4. Locate relay activation Jumper on rear of control panel. (Small plastic rectangle) 5. Gently remove jumper by pulling cap off pins. Shorting cap should be installed over a single pin for storage and to prevent loss of cap. Once the jumper has been removed the unit will only start by applying the proper voltage to the start stop relay. When the unit is running the on and off switch can be used as long as start relay has power. 6. Reinstall bottom panel and screws 7. Apply power to start relay (see wiring diagram for your unit) 7

RELAY DE-ACTIVATION 1. Disconnect all power sources to FA1 unit. 2. Locate and remove eight screws securing the bottom panel 3. Remove all eight screws and gently pry bottom panel loose CAUTION Do not work on panel with power applied Relay activation jumper 24 volt start connector 4. Locate relay activation Jumper on rear of control panel. (Small plastic rectangle) 5. Gently install jumper by pushing cap over pins. Once the jumper has been installed the unit will can only be started by using the control panel. All relays will become non-functional. 6. Reinstall control panel and screws 7. Apply power to unit 8. Start Unit 8