FTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE

Similar documents
300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

COMPRESSED AIR LOADER MODEL: AL-1

Models & Options Lubrication. 1/2 Through 10 Hp Models 1Ø 3Ø 1/2 Through 10 Hp Models 1Ø and 3Ø

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

Installation & Service Manual for Horizontal Cartridge Filtration Systems

Dome-Loaded Pressure Reducing BD-Series

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

Operating Instructions for the. In Line Conveyor System West Cabot Boulevard Langhorne, PA w w w.empire-airblast.

VT Oil-Free Range Operators Handbook

VERSA-CUT 60 PLASMA CUTTER

SPC-PANEL Simplex, Single Phase Pump Control Panel

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS AIR-COOLED AFTERCOOLER FOR COMPRESSED AIR SYSTEMS MODELS AC-140 thru AC-220 (ALL VOLTAGES)

CIRCLE SEAL CONTROLS

TECHNICAL INFORMATION

HIGH PRESSURE AIR COMPRESSOR SYSTEM MODEL #: 091-9HP-220 INPUT:

High Performance Vacuum Pump Model 15120A/15121A Operating Manual...

VWR Zero Air Generator

Automotive Air Conditioning Manifold Gauge Sets

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER PROBE MOUNTED LIQUID ELIMINATOR

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

36-1 DP PLEASE READ BEFORE USING THIS EQUIPMENT

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

CIRCLE SEAL CONTROLS

General Installation Instructions for Valves and Gates

TABLE 1. * SPECIFY S Stainless Steel Knob Part No S or Part No ST (for tips) for pressure exceeding 700 PSI.

Operation & Maintenance Manual. Sludge Vac. Visit our Website for more information on this product.

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

EXT DUCTLESS FUME HOOD

Installation and Service Manual for RV33, RV332, RV75, RV752, RV100, RV1002

DEMA MODEL 692T FOAM STATION I INSTALLATION INSTRUCTION

STC E-Series Electrically Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way

Positive Displacement Pump

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

Installation and Service Manual for SRC25, SRC252, SRC50, SRC502, SRC75, SRC752

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

EXT HEPA/CARBON FUME HOOD

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

Transfer Switch GPTS 30

Junior Sandblaster. Model #51 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL & WEAR EYE PROTECTION

Tuffy Liquid Level Controls with Pneumatic Switch

HPZA-3500, HPZA-7000, HPZA-18000, HPZA-30000

F200 Series. Compressed Air and Gas Filters. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades

Item no Smart AC 200 USB. User s Manual

OXYGEN GENERATING SYSTEMS INTL. Oxygen System Start-up, Overview and Maintenance Guide

FADE Series Wall Axial Fans

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

T1-Titanium Non-HVLP Spray Gun

AUTO PUMP 12V MODEL #: V 12 VOLT DC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. INPUT: Volts DC, 11 Amps OUTPUT: 100 PSI Max

Dual Flow Manifold Systems Instruction Manual

Electronic Timer Drain and Filter Ball Valves. Operating Instructions Manual

MRC 150/300 USER MANUAL. 1 Laird Technologies

6L Oil-less Air Compressor 53103

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BTX-208. Fume Extraction System _B

DEMA MODEL 693T FOAM STATION II INSTALLATION INSTRUCTION

DFA Series. Rainwater/Graywater Filtration Systems. Installation, Operation and Maintenance Manual DFM-2F-180 DFM-3F-180 DFM-3F-350

Installation and Operating Manual

Operation & Service Manual

STC 2L Series Solenoid Valves

Installation & Service Manual for Portable Fume Collector. Model PFC-800

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

F200 Series. Compressed Air and Gas Filters FEATURES. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

User s Manual for Tennessee Chill Box System P/N CB8000

User s Manual D-Series Blowers and Exhausters

Series K Pneumatic Switch Mechanism

Type D0800. Bantam Cartridge Holder OPERATION MANUAL AND PARTS LIST SERIES 494. Mo de l # Vo ltag e D D /12/08

Dual/Triple Manifold Water Filtration Systems Instruction Manual

Standard Service / Installation / Operation Manual Type W & P Water / Glycol Heat Transfer Coils

Eaton Filtration, LLC

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

LABORATORY ZERO AIR GENERATOR MODEL N-GC1500 USER S MANUAL

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

Medi-Flow. Model M101 & M101D Medicator Instructions GETTING TECHNICAL ASSISTANCE

SPH-400 i Series General Manual

COMPACT BAGHOUSE COLLECTOR

D-Series Blowers and Exhausters

QPV1 Electronic Pressure Regulator INSTALLATION AND MAINTENANCE INSTRUCTIONS

1600 PSI ELECTRIC PRESSURE WASHER

GLOBE FLOWCELL. Operating Manual. Rola-Chem Flowcell PN /01/2013 page: 1 of 8

Adjustable Purge Valve

HP190SL Series Slimline Radon Fans

Easytork Solenoid Valve IOM

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Product Recovery Canister

Product Information ROSS CONTROLS

Self Cleaning Hood System Installation, Operation, and Maintenance Manual

Scale Feeder Manifold Water Filtration System Instruction Manual

USER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i)

Dual Port Manifold Water Filtration Systems Instruction Manual

NECO Pumping Systems

PROVEX Installation Guide. Version 1.0

Raydot LLC 24 Actuator (115 VOLT)

Transcription:

FTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE TABLE OF CONTENTS SECTION 1 General Information: Model Description Pg 2 Serial Numbers Description of Operation SECTION 2 Safety Instructions: Pg 3 Installation Safety Operation Safety SECTION 3 Specifications: Pg 3 Flows, Connections, Dimensions, and Weights SECTION 4 Installation Pg 4 Parts Included Location Install Filters Mounting Electrical Connections Piping and Connections SECTION 5 Start-Up Pg 5 SECTION 6 Maintenance Pg 5 SECTION 7 Replacement Parts Pg 6 SECTION 8 Troubleshooting Guide Pg 7 SECTION 9 Wiring Diagram Pg 8 SECTION 10 Warranty / Claims Pg 8 PRINTED IN THE USA

SECTION 1 GENERAL INFORMATION 1.1 MODEL DESCRIPTION The FTIR-PG28 Purge Gas Generator is designed to remove water and CO 2 from a compressed air stream. This is done by passing the air through beds of adsorbent media (13X molecular sieve) which adsorbs both H 2 O and CO 2. 1.2 SERIAL NUMBER CODING MONTH/YEAR OF MANUFACTURE SERIAL # 1.3 DESCRIPTION OF OPERATION The FTIR-PG28 Purge Gas Generator uses the pressure swing adsorption method of gas separation. This requires two identical towers containing beds of adsorbent desiccant media. Incoming wet, CO 2 rich air enters the adsorber/dryer through the inlet port, where energized SOLENOID VALVE A directs the pressurized air stream to the bottom of DESICCANT TOWER A containing active adsorbent. This adsorbent media bed removes water vapor and CO 2 gas from the air to better than -100 F dew point and less than 1 PPM CO 2 when operated at catalog conditions. The dry and CO 2 free air leaving the top of DESICCANT TOWER A is directed to the outlet through open CHECK VALVE A. PURGE ORIFICE B and closed CHECK VALVE B allow a metered portion of the processed air to flow into DESICCANT TOWER B being regenerated. The open purge port on deenergized SOLENOID VALVE B and the purge orifice reduce the pressurized dry air down close to atmospheric pressure and regenerate the adsorbent media by removing the accumulated water vapor and CO 2 and carrying it out the open purge port. FIG 1 SOLENOID VALVE TIMING CYCLE 30 seconds per side continuous 1 minute total cycle time The two solenoid valves are controlled by a solid state timer. After 30 seconds, the media in DESICCANT TOWER B is regenerated, and the solid state cycle timer causes the process to instantly reverse, with TOWER B adsorbing and TOWER A regenerating. The following flow schematic (FIG 1) demonstrates the adsorber/dryer operation. Page 2

SECTION 2 SAFETY INSTRUCTIONS 2.1 INSTALLATION SAFETY Before starting or installing the FTIR-PG28 Purge Gas Generator, be sure that all power to the unit is off, valves are shut, and the air circuit is at atmospheric pressure. DO NOT remove, repair, or replace any component, control filter, or part, while the unit is energized or the air circuit is under pressure. Unplug unit and de-pressurize the unit before starting installation or maintenance procedures. The FTIR-PG28 is rated NEMA 1. 2.2 OPERATION SAFETY DO NOT OPERATE THE FTIR-PG28 PURGE GAS GENERATOR AT COMPRESSED AIR PRESSURES ABOVE 150 PSIG. UNIT FAILURE, INJURY AND EQUIPMENT DAMAGE COULD RESULT CAUTION: EXCEPT as otherwise specified by the manufacturer, this product is specifically designed for compressed air service and use with any other gas or liquid is a misapplication. Manufacturer s warranties are void in the event of a misapplication and manufacturer assumes NO RESPONSIBILITY for any resulting loss. Before using equipment with fluids or gases other than air, consult Matheson Tri-Gas for written approval. SECTION 3 SPECIFICATIONS 3.1 FLOWS, CONNECTIONS, DIMENSIONS, AND WEIGHT MODEL NO. FTIR-PG28 Max Flow Capacities at 125 PSIG (L/M) Inlet Flow 48 Purge Flow 16 Outlet Flow 32 Connections (NPT) Inlet 1/4 Outlet 1/4 Dimensions (Inches) Height 27.7 Width 17.2 Depth 6.2 TABLE 1 OUTLET FLOW CAPACITIES AT VARIOUS INLET PRESSURES WITH PURGE ORIFICE REQ D PSIG lit/min orifice no. 150 37.8 18 140 35.5 18 130 33.2 18 120 30.5 18 110 25.5 20 100 23.1 20 90 19.5 20 80 16.6 22 70 13.3 24 60 9.8 26 50 5.7 26 Weight (Pounds) 25 Note: Outlet flows shown above are maximum capacities and should not be exceeded for best performance. No outlet flow metering valve or flow meter is installed on the adsorber/dryer and must be provided by the user. Purge flow is metered by integral fixed purge orifices. Capacities are based on inlet conditions of 70 F, 100%RH, normal ambient CO 2 levels of approx 350-375 ppm. Outlet concentration of CO 2 will be less than 1 ppm and outlet dew point better than -100 F. If your flow, temperature or pressure are different from above, consult factory for performance. Unless otherwise specified, a #18 orifice set has been installed as standard. Page 3

INLET BULKHEAD FITTING OUTLET BULKHEAD FITTING POWER ON/OFF SWITCH OUTLET FILTER REGULATOR WALL MOUNTING HOLES INLET COALESCING FILTER ADSORBER/DRYER PURGE MUFFLERS FIG 2 SECTION 4 INSTALLATION 4.1 PARTS INCLUDED (1) FTIR-PG28 Purge Gas Generator (1) Inlet Coalescing Filter Assy. (1) Outlet Filter Regulator Assy. (6) Cover Screws, 6-32 x 3/8, PH, SS (1) Operations & Maintenance Manual 4.2 LOCATION DO NOT INSTALL THE UNIT IN AN ENVIRONMENT OF CORROSIVE CHEMICALS, EXPLOSIVE GASES, OR AREAS OF HIGH OR LOW AMBIENT TEMPERATURE (ABOVE 125 F OR BELOW 33 F). Install the unit indoors. Unit may be wall mounted or placed on a table top. 4.3 INSTALL FILTERS A coalescing filter is provided to be installed on the inlet to the adsorber/dryer to remove entrained particulates, liquid moisture and oil which can cause damage to the desiccant beds. A particulate afterfilter is provided to be installed on the outlet of the adsorber/dryer to remove any adsorbent media dust that may migrate from the desiccant beds. Using a wrench to keep inlet bulkhead fitting from turning, install Inlet Filter Assy to left side of unit as shown in FIG 2 above. Similarly, install Outlet Filter Regulator Assy to Right Side of unit. 4.4 MOUNTING 1. Table top a. The unit comes with rubber feet installed on bottom of cabinet for use on table top. 2. Wall mounting a. Remove (6) cover screws and remove cover. While a helper holds the unit at the mounting location, mark the position of the (4) mounting holes at the back of the cabinet. Mount the cabinet using these mounting holes. Be sure to use proper wall mounting anchors if mounting in drywall. b. Reinstall cover. 4.5 ELECTRICAL CONNECTIONS Before plugging in unit, check the unit nameplate for electrical characteristics. Standard electrical characteristics are 115 volt, 1 phase, 50/60 Hz. Models operating on 230 volts are available. IMPORTANT!: No overload protection is provided in the adsorber/dryer and unit should be plugged/wired into a protected circuit. 4.6 PIPING AND CONNECTIONS Inlet and outlet tubing should be appropriate for pressure and temperature of operation. See specification chart for inlet/outlet NPT thread size. Teflon tape should be used in the makeup of joints to ensure a good, airtight fit of piping components. Check all connections for leakage using soap solution prior to putting unit into service. Page 4

SECTION 5 START UP BEFORE UNIT START UP, FOLLOW THE INSTALLATION INSTRUCTIONS AND PROCEDURES COMPLETELY. DO NOT REMOVE, REPAIR OR REPLACE ANY ITEM ON THE ADSORBER/DRYER WHILE THE ADSORBER/DRYER IS UNDER PRESSURE. 5.1 INITIAL START UPS 1. Confirm that all piping and electrical connections are proper. 2. Turn on the electrical power. Adsorber/dryer should start cycling with a small purge noise heard every 30 seconds. SECTION 6 MAINTENANCE DO NOT REMOVE, REPAIR, OR REPLACE ANY ITEM ON THE ADSORBER/DRYER WHILE THE ADSORBER/DRYER IS UNDER PRESSURE. BEFORE BEGINNING ANY REPAIRS, MAINTENANCE, OR INSTALLATION WORK, VERIFY THAT THE POWER IS OFF AND THE ADSORBER/DRYER IS DEPRESSURIZED. BEFORE WORKING ON THE ADSORBER/DRYER OR RELATED EQUIPMENT, ENSURE THAT ALL PERSONNEL HAVE READ AND UNDERSTAND THE SAFETY AND OPERATION INSTRUCTIONS IN THIS MANUAL. 6.1 PREVENTIVE MAINTENANCE Below is a suggested schedule based on average operating conditions. As conditions such as dirty environment, humidity conditions, ambient temperature, etc. change, the frequency of the inspections may need to be increased. Daily 1. Inspect the adsorber/dryer for proper cycling. 2. Inspect inlet filter for proper drain operation. 3. Verify proper inlet pressure and ambient air temperature conditions. Semi-Annually 1. Inspect entire assembly for loose connections, screws, etc. Annually 1. Replace inlet filter elements, outlet filter elements, and purge mufflers: Inlet Filter Element # M18-02-CG00 # MTP-96-646 Outlet Filter/Regulator Element # B03-02-G000 #PS403 Purge Mufflers #ASN-6 (qty 2) Page 5

SECTION 7 REPLACEMENT PARTS Part Number Description (refer to FIG 3) 51448 POWER ON/OFF SWITCH F14E11B13F OUTLET FILTER/REGULATOR WITH GAUGE PS403 - OUTLET FILTER ELEMENT ONLY P77413 - GAUGE ONLY F11F16E INLET FILTER WITH AUTO DRAIN PS724 - INLET FILTER ELEMENT ONLY 20020 POWER CORD (NOT SHOWN) ASN-6 MUFFLER, PURGE, 1/8 NPT, (ORDER QTY 2) 51330-0XX ADSORBER/DRYER INSERT ORIFICE NUMBER FOR XX (SEE TABLE 1 ON PAGE 3 FOR ORIFICES/FLOWS) POWER ON/OFF SWITCH OUTLET FILTER REGULATOR WITH GAUGE INLET COALESCING FILTER ADSORBER/DRYER PURGE MUFFLERS FIG 3 Ref. No. Part Number Adsorber/Dryer Part Description (refer to FIG 4) Qty / Unit Incl. in Kit (#15) FIG 4 1 51254 TOWER, 20", 51330 CO 2 ADSORBER/DRYER 2 2 - O-RING, TOWER 2 x 3 - O-RING, PURGE ORIFICE, INNER 2 x 51315-27 PURGE ORIFICE, #27 FOR 140-150 PSIG OPER. 4 51315-29 PURGE ORIFICE, #29 FOR 120-130 PSIG OPER. 51315-32 PURGE ORIFICE, #32 FOR 80-110 PSIG OPER. 2 51315-40 PURGE ORIFICE, #40 FOR 50-70 PSIG OPER. (SEE TABLE 1 ON PAGE 3 FOR ORIFICES/FLOWS) 5 - O-RING, PURGE ORIFICE, OUTER 2 x 6 51308 MOISTURE INDICATOR WITH O-RING (NOT SHOWN) 1 7 - O-RING, MOISTURE INDICATOR 1 8 51316 BALL, CHECK VALVE 2 x 9 51317 SPRING, CHECK VALVE 2 x 10 51302 MANIFOLD 1 11 51319 PLUG, MANIFOLD 2 12 - O-RING, SOLENOID VALVE 2 x 13 51321 SOLENOID VALVE ASSY, 53 VDC, FOR 115 VAC UNIT 2 13A - CORE, SOLENOID VALVE 2 x 13B - BASE, SOLENOID VALVE 2 x 13C - FRAME, SOLENOID VALVE 2 x 14 - COIL (ORDER COMPLETE SOLENOID VALVE ASSY) 2 15 51325 KIT, MAINT., ADSORBER/DRYER 1 16 51310 ADSORBER TIMER, CYCLE, FOR 115 VAC UNIT (NOT SHOWN) 1 17 51313 ADSORBER BOTTOM COVER (NOT SHOWN) 1 18 51318 ADSORBER BRACKET, MOUNTING (NOT SHOWN) 1 Page 6

SECTION 7 TROUBLESHOOTING GUIDE A PROBLEM: UNIT DELIVERS WET AIR OR HIGH CO 2 LEVELS POSSIBLE CAUSE CHECK CORRECTIVE ACTION A1 High inlet air temperature. For standard units, inlet air temperature should be 70-80 F. Reduce inlet air temperature to proper level. An aftercooler may need to be installed after compressor. A2 Air flow through dryer in excess of rated capacity. Make sure outlet flow does not exceed rated flow. See capacity chart in SPECIFICATIONS. Reduce air usage downstream. A3 Low inlet pressure. See capacity chart in SPECIFICATIONS. Increase inlet pressure. A4 Dirty or obstructed inlet air filter. Check inlet airline filter elements. Replace elements. A5 Purge orifice plugged. Check purge air flow with flowmeter. Clean or replace purge orifices. A6 Solenoid coil burned out. Check coil leads with ohmmeter. Open (burned out) coil will have no reading. A7 Oil contamination of desiccant beds. Verify particle/coalescing inlet filtration is adequate and functioning properly. A8 Timing cycle improper. Verify correct timing cycle by listening to purge or by using voltmeter across coil connections on timer. A9 Purge flow restricted. Check mufflers for excessive backpressure. Replace valves. Towers must be replaced if contamination is suspected. Replace timer if defective. Replace mufflers. B PROBLEM: RESTRICTED FLOW THROUGH UNIT POSSIBLE CAUSE CHECK CORRECTIVE ACTION B1 No power to unit. On-Off switch and power supply. Correct power problem. B2 Improper operating See A2, A3 above. conditions. B3 Dirty or obstructed inlet air See A4 above. filter. B4 Plugged air passages. Check inlet and outlet air passages and piping for blockages. B5 Inlet and outlet ports reversed. Check inlet and outlet ports for proper connections. Clear restrictions. Reconnect properly. C PROBLEM: EXCESSIVE PURGE POSSIBLE CAUSE CHECK CORRECTIVE ACTION C1 Check valve not closing. Check for damage or contamination of Clean or replace as necessary. check valves. C2 Purge orifice(s) incorrect. Measure purge flow with flow meter. Install correct purge orifice(s). Page 7

SECTION 9 WIRING SECTION 10 WARRANTY SS TIMER L 1 L 2 53 VDC SIGNALS OUT S 1 S 2 115 VAC IN Matheson Tri-Gas warrants the FTIR-PG28 Purge Gas Generator to be free of defects in materials and workmanship under proper use, installation and application. This limited warranty shall cover parts or replacement unit only, for a period of 18 months from date of shipment or 12 months from date of installation, whichever comes first. ALL FREIGHT DAMAGE CLAIMS ARE NOT THE RESPONSIBILITY OF THE MANUFACTURER AND ARE NOT COVERED UNDER WARRANTY AS ALL PRODUCTS ARE SHIPPED F.O.B. SHIPPER. PLEASE DIRECT ALL FREIGHT CLAIMS TO THE FREIGHT CARRIER IN QUESTION. S1 S2 SOLENOID VALVES FIG 5 FTIR-PG28 WIRING DIAGRAM This warranty does not apply to any unit damaged by accident, modification, misuse, negligence, or misapplication. Any covered FTIR-PG28 Purge Gas Generator part or material found defective will be repaired, replaced or refunded, at Matheson Tri-Gas s option, free of charge, provided that Matheson Tri-Gas is notified within the above stated warranty period. All returns of defective parts/equipment must have prior written Returned Material Authorization (RMA). RMA may be obtained from our service department. All defective parts/equipment must be returned freight prepaid to the Matheson Tri-Gas factory within 30 days of RMA issue date. Any shipment returned to the factory collect will be refused. If an item is found to be warrantable, the repaired item or replacement will be shipped via standard ground freight prepaid within the continental US and Canada. Any replacement part or material is warranted only to the extent of the remaining warranty period of the adsorber/dryer or to the extent as provided by the supplier, whichever is longer. All freight damage claims should be filed within 15 working days and should be directed to the freight carrier. Matheson Tri-Gas 166 Keystone Drive Montgomeryville, PA 18936 Phone: 800-416-2505 Fax: 215-619-0458 Email: info@matheson-trigas.com Page 8