High Precision Turbine Wheel Flow Meter for Liquids

Similar documents
Turbine Wheel Flow Meter

Compressed Air-Supply Meter

Model: TUR with transmitter. Output: pulses, 0-20 ma, 4-20 ma or 0-10 V, LED display, pointer indication, switching output

TUR. Turbine Wheel Flowmeter. plastic version for liquids. Measuring ranges: ,0 m 3 /h water. ± 1% of full scale

TWL-Exia. Resistance Thermometers according to DIN. Ignition Protection Exia. Pt 100-sensor class A respectively class B

Vortex Flow Meter Model DVH

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

Hygienic Installation Systems

Differential pressure gauges with Bourdon tube

Vortex Flowmeter Model DVE

Contact Device. for Pressure Gauges

Paddle Flow Monitor Model PSR/PSE

Flow. Oval Wheel Flowmeter Model DOE

NGS. Dual-Magnet Float Switch. Pressure: up to 25 bar. Density: > 0.7 kg/dm 3. High switch capacity. Material: stainless steel 1.

DOR. Insertion Paddle Wheel Flow Meter/Monitor. for Low Viscous Liquids. Flow range: l/s to l/s. Flow velocity range: 0.

TUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water)

DOR. Insertion Paddle Wheel Flowmeter/Monitor. for low viscous liquids. Flow range: ,300 l/s to ,000 l/s. Flow velocity range: 0.

PSR/PSE Paddle Flow Monitor for Liquids Switching ranges: L/min water p max : 250 bar, t max

MAN-P. Diaphragm Pressure Gauges. according to EN for Stringent Demands

Accessories for Pressure Gauges

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

KDM ARMORED FLOW METER & SWITCH

MMA. Insertion Resistance Thermometers. with, or without transmitter. OEconomically-priced O thermometers with optional plug-on display

PSF50 Paddle flow switch

Operating Instruction for Flowmonitor. Model: DF-WM

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

Flow. Oval Wheel Flowmeter Model DON

Mass Flow Meter Model: MAS. Design

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Operating Instructions for Viscosity Compensated Flow Meter / Monitor. Model: VKM

Magnetic-inductive flow meter for hazardous areas

DWU. Paddle Bellows Flow Monitor. for liquids. 1-5 l/min m 3 /h water OAccuracy: ±3... ±5% of full scale OConnection: O

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids

DTK. OEM Pelton Wheel Flow Sensor

TER. Thermostats for Industrial Applications. Switching range: C to C. Housing material: aluminium. Capillary tube: copper

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

NCP/NCB/NCS. Magnetic Float Switches. for Liquids

RCM. Direct Reading Flowmeter. for Liquids or Gases

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Turbotron // VTH15, VTM15, VTP15, VTI15

SITRANS F M flow sensors 711/A and 711/911E

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Design and application

HM...TC-R. Turbine Flow Meters for Solvents and Di-Water. Technical Datasheet

Capillary Thermometers according to DIN Nitrogen Filled Option: Contacts

Metal tube variable area flowmeter for gases, liquids and steam

2/2 Pressure operated valves

3/2-way Rocker Solenoid Valve for pneumatic systems

DRT. Ring Piston Flow Meter. for low/high Viscous Liquids

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

Type 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal

Volumeter. RMG Meßtechnik GmbH. Publication No E

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Flow switches Series AD/VH

Turbine flowmeters Series TM

STEEMCO Flowmeter for Steam

HM...TRI. Turbine Flow Meters (Tri-Clamp) for pharmaceutical Applications. Technical Datasheet

Operating Instructions for Torsion Paddle Flow Meter / Monitor. Model: DPT-...

ORIMAS Mass Flowmeter

C 200 Modern Construction. Flexible Modular Design. Highest Safety.

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Level measurement Guided microwave Product Information VEGAFLEX ma/hart. Level Switching Pressure

Absolute pressure gauge with diaphragm

Differential pressure gauge with diaphragm

STEEMCO-MAS Flowmeter for Steam

CombiTemp Temperature Measuring System

Turbine Flow Meters for Liquids

SM-08. Features. Miniature Turbine Flowmeter for Fluid Media. Description: Application:

TOP SMART intelligent position monitor:

Ball Valves with Pneumatic Actuator Screw Thread and Flange Connection, Welded Connection

Pressure Transmitter

Flow VA 500/ 520. Flow sensors for compressed air and gases incl. temperature measurement. Verbrauch.

Pump kits. We deliver values.

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

Magnetic-Inductive Flow Meter FMQ

Flow meter Type Recordall (RCDL)

Product. Information. A.u.K. Müller. Flow meter turbine, with shut-off device. Series Characteristics. Applications.

Operating Instructions for Paddle Flow Monitor. Model: PSR-..., PSE-...

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam

Direct-acting 3/2 way plunger valve

MODEL 106F TEFLON LIQUID FLOW SENSOR

Ar-Mite TM Low Flow Armored Flowmeter

TORRIX Magnetostrictive level sensor

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-..

Magnetic Inductive Flowmeter EP / UMF2 (B)

Flap-Type Flow Meter Prall

DPT TARGET TYPE FLOWMETERS

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines

PMG MAGNETIC FLOWMETER

Operating Instructions for Plastic Flow Meter. Model: KSK

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Transcription:

High Precision Turbine Wheel Flow Meter for Liquids measuring monitoring analysing Measuring ranges: 0.006-0.1 to 10-500 L/min water Measuring accuracy: ± 1.25% f. s. pmax: 345 bar; tmax: 135 C Viscosity range: low viscosity, max. 10 mm 2 /s Connection: R 1 4, R 1 2, hose connector 8 mm/11 mm intermediate flange DN 40 to DN 50 Material: Nylon, stainless steel, PVC, Titanium Output: pulses, 4-20 ma, contacts Display on site Model: PEL-L... Model: LMX KOBOLD offices exist in the following countries: ARGENTINA, AUSTRIA, BELGIUM, BRAZIL, CANADA, CHINA, FRANCE, GERMANY, GREAT BRITAIN, ITALY, MEXICO, NETHER- LANDS, PERU, POLAND, SWITZERLAND, USA, VENEZUELA KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. +49(0)6192 299-0 Fax +49(0)6192 23398 E-Mail: info.de@kobold.com Internet: www.kobold.com Model: PEL 69

Areas of application The sensor principle based on a Pelton water wheel is remarkable for its high reliability proven over more than ten years of service. This flow meter is to be found in applications in a variety of plants, where not only negligible volumetric flow rates of media such as fuels, highly distilled water, or hot greases are measured, but also high flow rates normally found in power stations. The sensors satisfy almost all industrial requirements with temperature limits of 135 C and nominal pressures up to 345 bar (higher pressures upon request). Only V4A Supra St.St. (material no. 1.4571) or titanium is used for metallic parts. Swiss precision bearings ensure long service life and reliability. Sensors with solid sapphire bearings and no metal parts have been developed to measure aggressive liquids such as sulphuric acid and hydrochloric acid. Other critical media such as toluene and vinyl chloride can be measured in hazardous environments. Sensors made of less expensive materials are used for less sophisticated conditions. Function Principle The model PEL flow meter works on the turbine wheel principle. The heart of this device is a Pelton turbine supported by tungsten/sapphire bearings. The Pelton turbine is an impeller with ferrite inserts embedded in the blade tips. When this turbine is brought into rotary motion, the motion is recorded by a coil mounted nearby; the resulting electrical impulses are passed to a control unit for further processing. Model PEL-L... for low flow rates Linerarity: 1% f.s. Repeatabilty: < ±0.25% at 90% of range Accuracy: ±1.25% f. s. at 10-100% of measuring range Measuring range: 100:1 to 280:1 Model PEL-M... for higher flow rates Linerarity: 1% f.s. Repeatabilty: < ±0.25% at 90% of range Accuracy: ±1.25% f. s. at 10-100% of measuring range Measuring range: at least 50:1 Sensor-Coil Ferrite Inserts Ferrite Inserts Sensor-Coil Outlet Inlet Outlet Inlet Model PEL-L flow meters measure the entire volumetric flow that passes through the instrument. A nozzle guides the flow to the impeller. The resulting turbine rotation is proportional to the flow rate. A small sensing coil signals the approach of the ferrite inserts contained in the impeller. An output signal with constant current is then produced by the electronics. The PEL-M devices comprise a Pelton turbine and screen. A small part of the total volumetric flow is forced through the Pelton turbine by the differential pressure at the screen. The total flow can be determined from the partial flow, as the relationship between partial flow and total flow is always constant. This method is especially suited for high flow rates and is used in lines up to DN 300. 70 www.kobold.com

Model PEL-L000.. PEL-L001.. PEL-L005.. PEL-L024.. PEL-L045.. PEL-L090.. PEL-L220.. Process connection Meas. range [L/min] 0.006-0.1 0.01-0.25 0.02-1.3 0.03-4.3 0.04-6.3 0.08-15 0.1-28 Housing Electronic housing Turbine ring Rotating vane Rotating vane bearings Rotating vane axle O ring pmax Hose conn. ø 8mm/11 mm incl. mounting R 1/2 AG Version..GN1....LMX....S03....S20....S34....Ti1.. R 1/4 AG R 1/4 AG R 1/4 AG glass/nylon* VA VA VA VA R 1/4 AG VA Alu Alu (shaft in VA) VA VA VA VA VA VA glass/nylon PFA PFA PFA PFA PFA VA/sapphire sapphire (mounting VA) VA R 1/4 AG VA/sapphire VA/sapphire VA/sapphire VA/sapphire VA/sapphire VA/sapphire FPM (optional: EPDM, Kalrez, PTFE covered FPM) 5 bar 100 bar 40 bar 30 bar 100 bar 200 bar 345 bar tmax 75 C 100 C 70 C 135 C 135 C 135 C 135 C Version electronic housing rubber cap rubber cap rubber cap housing IP 65 housing IP 65 housing IP 65 housing IP 65 VA VA PFA R 1/4 AG Ti Ti PFA Ti 50 bar 135 C housing IP 65 Model Meas. range [L/min] PEL-M012.. 1-65 PEL-M020.. 2-130 PEL-M025.. 3-160 PEL-M030.. 5-220 (pmax 66 bar) PEL-M037.. 7-350 (pmax 54 bar) PEL-M050.. 10-500 (pmax 40 bar) Connection size R 1/2 R 3/4 R 1 R 1 1/4 DN 40 DN 50 Version..LMX..**..Ti1..***..PVC.. Connection Housing Electronic housing Turbine ring Rotating vane Rotating vane bearings Rotating vane axle O ring pmax Male thread Female thread R 1/2...R 1 1/4 or intermediate flange DN 40/DN 50 www.kobold.com Female thread R 1/2...R 1 1/4 or intermediate flange DN 40/DN 50 Female thread R 1/2...R 1 1/4 Glue-in pipe VA VA VA Ti PVC Alu PVC VA VA VA Ti PVC PFA PFA PFA PFA glass/nylon* VA/sapphire VA/sapphire VA/sapphire VA/sapphire Ti FPM FPM Alu (shaft in VA) sapphire (mounting VA) FPM FPM FPM 100 bar 40 bar 100 bar 50 bar 5 bar tmax 100 C 70 C 135 C 135 C 60 C Version electronic housing rubber cap housing IP 65 housing IP 65 housing IP 65 rubber cap * Glass-fibre reinforced Nylon ** Version for PEL-M012 only *** not for PEL-M037 and PEL-M050 71

Flow rate pressure loss diagram mbar 1000 001 005 024 045 090 012 020 025 030 037 050 (Measuring range code) 100 10 1 0,1 0,02 0,01 0,02 0,1 1 10 100 1000 10000 L/min Technical Details Standard pulse output (Code F) Power supply: 11-17 V DC, max. 8-15 ma Signal: +2 V upto max. VS Pulse input intrinsically safe (Code E) Connection with Zener barriers or Isolation Switching Amplifier Protection: EEx ia IIC T5 (BASEEFA) Zener barriers: 1 x PEL-MTL 722+ 1 x PEL-MTL 764+ Isolation Switching Amplifier: PEL-MTL 5032 Compact Dislay on site (Code K) Power supply: 12-30 V DC, typ. 50 ma Display: 2-segment LC display, actual amount 5-position, counter 7-position, changeable Linearisation: 9 points Output signal: 1 x pulse output, passive max. 12-30 V DC, max. 50 ma, 1 x analogue output 4-20 ma (passive), max. 12-30 V DC Temperature: -30...+80 C Materials Housing: ABS Display window: Polycarbonate Gasket: PE Dimensions: 130 x 114 x 58 mm Compact Dislay on site Ex (Code X) Technical data as Compact Display on site (Code K) Certificate: II 1GD EEx ia IIB T4 (CENELEC) Electrical connection Standard pulse output Voltage level - pulse output With 12 VDC power supply Pulse-calibration input Pulse output Voltage supply 11-17 VDC (15 ma) 72 www.kobold.com When using 24 VDC supply: use 10 K Ω 12 V 2 V 4k7 CAL MTR +VS

Order Details (example: PEL-L000 GN1 F) Measuring range* L/min Model Version/ material Evaluating electronics 0.006-0.1 PEL-L000 0.01-0.25 PEL-L001 0.02-1.3 PEL-L005 0.03-4.3 PEL-L024 0.04-6.3 PEL-L045 0.08-15 0.1-28 PEL-L090 PEL-L220 1-65 PEL-M012 2-130 PEL-M020 3-160 PEL-M025 5-220 PEL-M030 7-350 PEL-M037 10-500 PEL-M050 * Higher measuring ranges upon request Pulse output intrinsically safe with Zener Barriers..GN1....LMX....S03....S20....S34....Ti1....LMX....Ti1....PVC....Ti1....PVC....PVC....F = standard pulse output 11-17 V DC, 8-15 ma..e = pulse output intrinsically safe EEx ia IIC T5 (not for material GN1 and LMX) connection via Zener barriers or Isolation Switching Amplifier (not included in delivery)..k = Compact display on site, LC display, 24 V DC, outputs:pulse, 4-20 ma, 2 relays..x = Compact display on site EX 2-lines LC display, actual amount, counter pulse output, 4-20 ma passive, incl. linealisation, 24 V DC EEx ia stainless steel housing IP 68 / 2 x relay Pulse output intrinsically safe with Isolation Switching Amplifier Ex-Zone Electrical Connection Transmitter Ex Zone Electrical Connection Transmitter No Ex-Zone No Ex Zone MTL-722+ MTL-764+ MTR CAL +15 V +9 V Test Evaluation instruments in None Ex-Zone Blue clamps Installation with MTL barriers Alternative: Company Stahl Zener barriers Supply MTL 5032 Output +V (-) (+) Evaluation instrument in None Ex-zone Blue clamps www.kobold.com 73

Dimensions PEL-L...GN1 PEL-L...SPF PEL-L...S03 /...Ti1 PEL-L...S10 /...S20 /...S34 min. 20 mm 80 Square Mounting 75 with 200 or 300 bar PEL-L..000 upto..090..220 A 14 mm 17 mm B 8 mm 11 mm PEL-...LMX 180 77,5 83 1/2" Ø 57 1/2" 135 Rubber cap PEL-M...PVC PEL-M....012PVC..020PVC..025PVC..030PVC A B DN 65 mm 45 mm 12.5 mm 65 mm 50 mm 20 mm 85 mm 95 mm 60 mm 65 mm 25 mm 30 mm PEL-M037PVC; PEL-M050PVC PEL-M....037PVC..050PVC A 89 mm 106 mm B 36 mm 44 mm DN 40 50 min. 20 mm PEL-M037SPF; PEL-M050SPF; PEL-M037S10; PEL-M050S10 PEL-M....037..050 A 89 mm 106 mm B 300 mm 308 mm DN 40 50 PEL-M...SPF;...S10;...Ti1 PEL-M....012..020 A 75 mm 75 mm B 60 mm 60 mm DN R 1/2 R 3/4..025..030 95 mm 95 mm 75 mm 75 mm R 1 R 1 1/4 Diameter A 74 www.kobold.com