101162-ELE-MOS-E-2006 Electrical Engineer Holds a B. Sc. in Electrical Power & Machines Engineering and has over 7 years hands-on experience, mainly in operation, maintenance, commissioning and start-up. PERSONAL DATA Nationality : Egyptian Birth Date : 06/04/1983 Gender : Male Marital Status : Married Residence : El-Behira EDUCATION : B. Sc. in Electrical Power & Machines Engineering, Tanta University, 2006 LANGUAGES Arabic English : Native Language : Very Good COMPUTER SKILLS : Windows, MS Office (Word, Excel, Access, Power Point), Internet TRAINING COURSES AND CERTIFICATIONS : On-shore training of Combined Cycle (Gas turbine, HRSG and steam turbine) by simulator system, Nubaria. : On-shore training of gas turbine Siemens v94.3a each one produces 250MW, Nubaria. : On-shore training of steam turbine operation and maintenance by Mitsubishi Heavy Industries Company, Nubaria. : On-shore training of ALSTOM HRSG, Nubaria. : On-shore training of GE gas turbine (250MW) operation, Nubaria. : On-shore training of ALSTOM steam turbine, Nubaria. : On-shore training of high and medium voltage (500KV/220KV/6.3KV), Nubaria. : Operation on-shore training of Alspa p320 Distributed Control System (DCS) by ALSTOM Company, Nubaria. : Training on fire fighting, civil safety and rescue course, Ministry of Interior Affairs, Damanhour. www.egyptrol.com Page 1 of 5 Updated: May 2014
CHRONOLOGICAL EXPERIENCE RECORD Dates Employer Project Job title Job Description : From Feb. 2008 till now : Middle Delta Electricity Production Company (MDEPC) : Nubaria Combined Cycle Power Station (2x750MW): Two modules, each module consists of: - Two Gas Turbines SIEMENS types V94.3A / 250MW site rating, with GT Auxiliaries (Fuel gas and Fuel oil supply systems, Lube oil system, Hydraulic System, Compressed air system, Cooling system, Purge /NOX water system) - Two HRSG Alstom horizontal type - One Mitsubishi Steam Turbine Switchyard ABB 220KV 500KV switchyard JAPAN AG Four Tie transformer ZTR type 500/220KV Switchgear 6.3 / 400KV Pump House By INITEC COMPANY (CP 118) for (circulation & Service pump & Fire pump & Raw pump) and Closed Cooling &High / Low Feed Water Pump : Senior Shift Charge Engineer : Operation & Maintenance Engineer of switchyard 500KV & 220KV: - Operation and maintenance of Conventional Air Insulated Switchyard (AIS) Sumitomo Corporation CONISYS (Tokyo & Cairo) 500KV, ABB Corporation (Cairo) 220KV. - Operation and maintenance for switchyard equipments such as transformers, isolators, circuit breaker, insulators, surge arrestors. - Operation and maintenance for switchyard control room. - Energizing of transformers while commissioning. - Isolating and connecting switchyard equipments such as transformers, bus bars and over head transmission lines (OHTL). - Operation and maintenance for switchyard (LLIW) system. - Follow and deal with protective alarms in control room. - Follow the status of all equipments with the national electricity control center. Operation Engineer: - Basic operation of Mitsubishi Steam Turbine (2x250MW). - Basic operation of Siemens Gas Turbine (4x250MW) type V94.3A. - Basic operation of ALSTOM horizontal type heat recovery steam generator. Training Engineer: - Give training courses to Engineers and Technicians about the components of power plant and how to construct and operate the combined cycles (gas turbine HRSG steam turbine) and how to test the electrical equipments. Operation & Shift Charge Engineer at Nubaria Combined Cycle Module ӀӀӏ (750MW) Power Station: - Basic Operation of ALSTOM Steam Turbine 250MW. - Basic Operation of G.E. Gas Turbine (2x250MW) Type 9FA. - Basic Operation of STF horizontal type heat recovery steam generator. www.egyptrol.com Page 2 of 5 Updated: May 2014
Dates : From Oct. 2006 till Feb. 2008 Employer : North Bharia Petroleum Company Job title : Operation, Maintenance & Quality Engineer Job Description : Operation and maintenance of diesel generator (cat-type), distribution transformers. Operation and maintenance of fire fighting system for oil tanks. Construction of earthling system in the field. Operation and maintenance of all electrical equipment in separator station (heaters, separators and pumps). Field of experience : Corrective & preventive maintenance for the following: - 16.5/500KV main transformers for Siemens gas turbines. - 15/500KV main transformers for Mitsubishi steam turbines. - 500 MVA Tie transformers (500/220/11KV). - 500KV Conventional Air Insulated Switchyard: 6 Incoming feeders from main transformers to 500KV Bus bar. 4 Outgoing feeders from Bus-bar to (500/220/11KV) Tie transformer. 2 Outgoing feeders from 500KV Bus-bar to Cairo and Sidi Krir 500KV. - 220KV Conventional Air Insulated Switchyard: 4 Incoming feeders to bus bar 220KV. 8 Outgoing feeders from bus bar 220KV. 220KV Bus-Coupler. - Live Line Insulator Washing System (LLIWS). Witness for all tests in switchyard 500KV/220KV, switchgears 16.5/6.3KV (C.B, C.T, P.T, etc.) some tests (Polarity, Megger, Turns ratio). Witness for all tests on Power Transformers (D.C resistance, insulation Test, turns ratio, Tan δ). Witness for some tests on some Relays Low Voltage switchgear (6.3KV/400V). Switchyard 500KV consists of: - 9 Power transformers (ZTR & Hyundai). - 4 TFRs ZTR of CTG Turbines 16.5KV/500KV & 2TFRs ZTR of STG Turbine 15KV/500KV. - 2 TFRs Hyundai of CTG Turbines 15.75KV/500KV & TFR Hyundai of STG Turbine 19KV/500KV. - 2 Busbars 500KV, 3000 A (Double Busbar Double Breaker). - 4 ZTR Tie Transformers (each 3 single phase Auto TFR) 500/220/11KV. - 2 OHTL 500KV. - 12 Bays of "Sumitomo Japan" Dead Tank C.Bs. - 3 Bays of "Areva" live tank C.Bs. - CONISYS Live Line Insulator Washing (LLIW) System. - Capacitive & Inductive V.Ts. - Wave traps. Switchyard 220KV consists of: - 2 Bus bars 220KV, 3000 A (Double Busbar Single Breaker). - 220KV Bus Coupler. - 4 OHTL 220KV (Double Circuit). www.egyptrol.com Page 3 of 5 Updated: May 2014
- 12 Bays of "ABB" Live Tank C.Bs. - CONISYS Live Line Insulator Washing (LLIW) System. - Capacitive & Inductive V.Ts. - Wave traps. Control Room: - To control the system using: Areva Protection, Automation and Control Integrated System (PACIS). MICOM Bay Control Unit by Areva (BCU) Ver. C264 for control. MICOM by ALSTOM for protection as follows: P742, P741 for Busbar protection. P437, P442 for Distance protection. P143 for Breaker Fail. P126 for Backup protection. P632 for differential protection. ABB Protection relays as follows: REB 500 for busbar protection. Rel 316, Rel 531 for distance protection. Auto recloser system. CONISYS live line scada control unit. CONISYS & ABB Chargers, Rectifiers, Batteries and Inverters 400V AC>> 220, 48V DC room (UPS system). I have good experience in desalination of sea water such as multi-stag flashing (M.S.F.) and reverse osmosis (R.O.). Construction and testing to high and low voltage electrical equipments. How to train Engineers and Technicians everything about power plants. Commissioning, start-up and operation for SIEMENS gas turbine. Commissioning, steam blow, start-up, operation for 4 HRSG (ALSTOM 800 T/H, HORIZONTAL, NATURAL CIRCULATION) (STF 10049-9- CP-105). Commissioning, start-up and operation for steam turbine (MITSUBISHI & ALSTOM 250MW). Commissioning, start-up and operation for GE Gas Turbine, having 4 hot gas path inspection maintenance & 4 minor inspection of gas turbine (Siemens V94.3A). Operation, maintenance, qualifications of low voltage transformers, Distributors and transmission lines. Estimate starting time for the idle generation units and follows prescribed start-up procedures to bring units on line at specified time. Change the loading of turbine/generator as required from the board or through the electrical control system. Read meters and records data at specified intervals in appropriate logs and computers. Immediately report malfunctioning equipment of abnormal meter readings / equipment performance to supervisor and complete the appropriate records. Perform troubleshooting and documentation and assist in the resolution of problems discovered during the shift. Ensure safety compliance of self and others. Perform all work in compliance with safety handbook. Issue equipment clearance and work permits. Develop and implement plant operating procedures. www.egyptrol.com Page 4 of 5 Updated: May 2014
Maintain working knowledge of electric control system and computers this knowledge is required to assess information and make changes to ensure safe, reliable operation. Ensure the maintenance of the plant operating history through timely completion of plant logs and required documentation. www.egyptrol.com Page 5 of 5 Updated: May 2014