ELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB

Similar documents
ELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB

ELIMINATOR Hermetic filter drier Types DML and DCL

ELIMINATOR Hermetic filter drier Types DCL and DML

ELIMINATOR Hermetic filter drier Types DML and DCL

Eliminator Liquid line filter driers, type DCL and DML

MAKING MODERN LIVING POSSIBLE. Eliminator Liquid line filter driers, DCL and DML. Flare connection. Solder connection (copper) Technical brochure

Crankcase pressure regulator Type KVL

Crankcase pressure regulator Type KVL

Technical brochure Eliminator filter drier DCR - with replaceable solid core

Replaceable solid cores filter driers type CSR

HANDBOOK REFRIGERATING SYSTEM PROTECTORS. Ed REFRIGERATING SYSTEM PROTECTORS DP-ED 01/ ENG 1

ADK Filter Drier. Alco Controls. Filter Drier. Features

FDB Filter Drier. Alco Controls. FDB Filter Drier. Features. Introduction. Moisture removal capability. Construction

FDB Filter Drier. FDB Filter Drier. Technical Data

Crankcase pressure regulator Type KVL

BFK Bi-flow Filter Drier

Uni-Flow Filter Driers

DCY. Anti-acid filter driers Refrigeration & Climate Components Solutions. n Applications

Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory)

REFRIGERANT RECOVERY PRODUCTS

HANDBOOK PIPING ACCESSORIES. Ed PIPING ACCESSORIES AT-ED 01/ ENG 1

FILTER DRIERS PART NUMBER SIGNIFICANCE LIQUID LINE FILTER DRIERS TOTALINE LIQUID LINE FILTER DRIER PHYSICAL DATA DIMENSIONS

June 2015 / BULLETIN Catch-All. Liquid & Suction Line Filter-Driers FILTER-DRIERS. It s the CORE that counts!

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1

Anti-acid filter driers DCY

FILTER DRIERS - SPORLAN

PRODUCT DATA DTG SERIES Unidirectional Filter Driers

Sight glass (High pressure) Type SGP X, SGP I, SGP N, SGP RX, SGP RI and SGP RN

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1

R-22 R-404A/R-502/R-507A R-12/

Parker TEV Model Visual

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1

HANDBOOK VALVES. Ed VALVES VR-ED 02/ ENG 1

Thermostatic Expansion Valve

Maneurop reciprocating compressors MT - MTZ - NTZ

Reliable season change

Electrical Control Valves Series EX4, EX5, EX6, EX7 & EX8

ON/OFF zone valves AMZ 112, AMZ 113

TAKE-A-PART SHELLS TOTALINE LIQUID & SUCTION LINE REPLACEABLE SHELLS P505-8 SERIES PART NUMBER SIGNIFICANCE

Crankcase Pressure Regulating Valves

Technical brochure Electrically operated expansion valves, type ETS 6

Refrigeration K-211. Replacement Parts. Chillers, Condensers. Compressors, Motors. Electrical. Components. Heating. Indoor Air Quality.

REFRIGERANTS AND LUBRICANTS

The precise step to take

Filter solutions for Danfoss PAH, APP and CLP pumps

Pressure operated water valve Type WVFX and WVS

Danfoss Saginomiya 4 - Way Reversing Valves

Performer scroll compressors. SM - SY - SZ R407C - R134a - R22-50 Hz QUICK REFERENCE MAKING MODERN LIVING POSSIBLE

AIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP STANDARD PRODUCT

MAKING MODERN LIVING POSSIBLE. Performer scroll compressors. SM - SY - SZ R407C - R134a - R22-50 Hz. Quick reference

Pressure Control Type KPU

Thermostatic expansion valves Type TGE 10, TGE 20 and TGE 40

Electric expansion valves Type ETS 6

Subcritical CO 2 Innovations

Solenoid valves Type EVU for fluorinated refrigerants

WEIGHT (lb) PART NO WITH ACCESS CONNECTION (ODS) BALL PORT DIAMETER WA WAS

Electrical Control Valves

The Danfoss Turbocor Portfolio of Oil Free Compressors

HANDBOOK VALVES. Ed VALVES VR-ED 02/ ENG 1

Reliable season change

A full line of field-tested CO 2 controls, stocked for your convenience

EMERSON CLIMATE TECHNOLOGIES

HANDBOOK EXPANSION VALVES. Ed EXPANSION VALVES VE-ED 01/ ENG 1

Flow-compensated temperature controller AVTQ DN 15

Capacity regulators (hot gas bypass) PMC and CVC

MAKING MODERN LIVING POSSIBLE. Solenoid valves Type EVU for fluorinated refrigerants REFRIGERATION AND AIR CONDITIONING.

MAKING MODERN LIVING POSSIBLE. Residential and light commercial scroll compressors R407C - R22 - R410A 60 HZ QUICK REFERENCE

Control Card VLT FC Series

Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Alco Controls. Components for the Refrigeration Industry. Product Selection Catalogue

Installation Guide. VLT Real-time Clock MCB 117 VLT HVAC Drive FC 102, VLT Refrigeration Drive FC 103, VLT AQUA Drive FC 202, VLT AutomationDrive

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

Modulating liquid level regulators, direct-controlled SV 1 and SV 3

Electric expansion valve Type ETS ETS 400

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows

Electronic suction modulating valves type KVS

The new ICF 15-4 valve station: It s small, it s modular, it s flexible

APP pump instruction APP and APP 16-22

2/4/6.3, PAH 10/12.5, PAH 50/63/70/80/100 pumps

Valve bodies type RA-N with integrated presetting

Butterfly valve with electrical actuator VFY-WA

Butterfly valve with electrical actuator VFY-WA

Solenoid valves Type EVR 2 40 NC/ NO REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

ICV with flanges: Danfoss now makes retrofit easy

Danfoss VDHT Solenoid Valves WATER SOLUTIONS

SCY. Discharge line mufflers Refrigeration & Climate Components Solutions. n Applications

XV7.2KX Variable Speed Drive Compressor R600a V 50/60Hz

Semi-hermetic reciprocating compressors

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems

Cartridge pressure switch Type CB

Solenoid valve VDHT Standard BSP (British Standard Pipe)

PAHT pumps / PAHT G pumps / ATEX PAHT G pump

Electric expansion valve Type ETS ETS 400

PAHT pump PAHT X

Product Guide for HFO / HFO Blends. R448A/R449A R450A/R513A R1234ze. R134a R407A/F R404A/507 R12/502

X-tra Collection for designer radiators and bathroom towel rails

Pressure relief controller AVA (PN 25)

Transcription:

Data sheet ELIMINATOR Hermetic bi-flow filter drier s DMB and DCB Hermetic bi-flow filter driers, types DMB and DCB are for use in liquid lines on heat pumps. Hermetic bi-flow filter driers have built-in check valves which ensure that refrigerant liquid always flows through the filter driers from the outer side of the filter core towards the center. Thus all dirt particles are retained irrespective of flow direction. DMB and DCB filter driers ensure fast and effective adsorption of moisture as well as organic and inorganic acids. When building heat pump systems, the use of bi-flow filters can, depending on the type of system, save up to ten solder connections. This reduces production costs and the number of potential leakage points. Available with flare and solder (cu-plated steel) connections. For other connections please contact your Danfoss Sales Representative. Features The Core type DMB 00% 3Å Molecular Sieve core High drying capacity minimizing the risk of acid formation (hydrolysis) Recommended for use with HFO, HC, HFC and HCFC refrigerants Will not deplete oil additives The Core type DCB 80% 3Å Molecular Sieve with 20% activated alumina Perfect core blend for systems that operate at high condensing temperatures and require high drying capacity Recommended for use with HFO, HC, HFC and HCFC refrigerants The Shell PED approved for PS 46 bar Available with flare and solder (cu-plated steel) connections Optimum flow characteristics and dirt retention The check valves are not sensitive to dirt and give minimum restriction, irrespective of flow direction The Filter Effective dirt removal to 25 μm No dirt released by reversing the flow direction Available in sizes 8 30 cubic inches Danfoss DCS (za) 206.04 DKRCC.PD.ED0.D4.02 520H098

Approvals UL US, file no. SA 6398 PED 97/23/EC - a3p3 Compliant with ATEX hazard zone 2 Note: Only solder versions (cu-plated / pure copper) and connection sizes below 25 mm are approved for flammable refrigerants now. Technical data Surface and volume Filter Solid core surface Solid core volume Filter drier volume (shell volume) Filter drier volume (net volume) [cm 2 ] [cm 3 ] [l] [l] DMB/DCB 08 73 80 0.0 0.088 DMB/DCB 6 00 45 0.30 0.234 DMB/DCB 30 250 365 0.49 0.322 Acid capacity Filter Acid capacity ) [g] DCB 08 0.96 DCB 6.29 DCB 30 3.6 ) Adsorption capacity of oleic acid at 0.05 TAN (Total Acid Number). Solder connection (cu-plated steel) Temperature range: -40 70 C Dirt retention Particles > 25 μm Technical data and capacities Drying and liquid capacity, type DMB Drying capacity [kg] refrigerant ) Liquid capacity [kw] 2 ) Max. R34a R404A R507 R22 R407C R40A Working Pressure [ C] R34a R404A R507 R22 R407C R40A PS 24 52 24 52 24 52 24 52 24 52 24 52 [bar] DMB 082/082s 9. 8.6 9.7 9.2 9.9 9.2 9.2 8.5 9. 8.4 8.3 7.6 3.9 2.8 2.8 4.3 4.3 4.3 46 DMB 083/083s 9. 8.6 9.7 9.2 9.9 9.2 9.2 8.5 9. 8.4 8.3 7.6 7.4 5.3 5.3 8.2 8.2 8.2 46 DMB 084/084s 9. 8.6 9.7 9.2 9.9 9.2 9.2 8.5 9. 8.4 8.3 7.6 8.3 6.0 6.0 9.2 9.2 9.2 46 DMB 62 7. 6.2 8.4 7.4 8.7 7.3 7.3 6.0 7. 5.8 5.6 4.4 7.6 5.3 5.3 8.8 8.8 8.8 46 DMB 63/63s 7. 6.2 8.4 7.4 8.7 7.3 7.3 6.0 7. 5.8 5.6 4.4 8.0 3.0 3.0 20.0 20.0 20.0 46 DMB 64/64s 7. 6.2 8.4 7.4 8.7 7.3 7.3 6.0 7. 5.8 5.6 4.4 28.0 20.0 20.0 32.0 32.0 32.0 46 DMB 65/65s 7. 6.2 8.4 7.4 8.7 7.3 7.3 6.0 7. 5.8 5.6 4.4 37.0 29.0 29.0 40.0 40.0 40.0 46 DMB 303 42.0 39.7 45.2 42.8 46.0 42.5 42.5 39.3 42. 38.9 38.3 35.3 9.0 5.0 5.0 2.0 2.0 2.0 46 DMB 304/304s 42.0 39.7 45.2 42.8 46.0 42.5 42.5 39.3 42. 38.9 38.3 35.3 28.0 20.0 20.0 3.0 3.0 3.0 46 DMB 305/305s 42.0 39.7 45.2 42.8 46.0 42.5 42.5 39.3 42. 38.9 38.3 35.3 38.0 28.0 28.0 42.0 42.0 42.0 46 DMB 307s 42.0 39.7 45.2 42.8 46.0 42.5 42.5 39.3 42. 38.9 38.3 35.3 43.0 32.0 32.0 47.0 47.0 47.0 46 ) Drying capacity is based on following moisture content test standards before and after drying: R34a: 050 50 ppm W R404A, R507: 020 50 ppm W R407C: 020 50 ppm W R40A: 050 50 ppm W R22: 050 60 ppm W In accordance with ARI 70-2004 2) Given in accordance with ARI 70-2004 for t e= -5 C t c= 30 C Δp = 0.07 bar For technical data on other refrigerants, please contact your Danfoss Sales Representative Danfoss DCS (za) 206.04 DKRCC.PD.ED0.D4.02 520H098 2

Technical data and capacities Drying and liquid capacity, type DCB Drying capacity [kg] refrigerant ) Liquid capacity [kw] 2 ) Max. R34a R404A R507 R22 R407C R40A Working Pressure [ C] R34a R404A R507 R22 R407C R40A PS 24 52 24 52 24 52 24 52 24 52 24 52 [bar] DCB 082 / 082s 7. 6.7 7.6 7.2 7.7 7. 7. 6.6 7. 6.5 6.4 5.9 3.9 2.8 2.8 4.3 4.3 4.3 46 DCB 083 / 083s 7. 6.7 7.6 7.2 7.7 7. 7. 6.6 7. 6.5 6.4 5.9 7.4 5.3 5.3 8.2 8.2 8.2 46 DCB 084 / 084s 7. 6.7 7.6 7.2 7.7 7. 7. 6.6 7. 6.5 6.4 5.9 8.3 6.0 6.0 9.2 9.2 9.2 46 DCB 62 3.3 2.6 4.3 3.6 4.6 3.5 4.6 2.5 3.4.6 2.2.2 7.6 5.3 5.3 8.8 8.8 8.8 46 DCB 63 / 63s 3.3 2.6 4.3 3.6 4.6 3.5 4.6 2.5 3.4.6 2.2.2 8.0 3.0 3.0 20.0 20.0 20.0 46 DCB 64 / 64s 3.3 2.6 4.3 3.6 4.6 3.5 4.6 2.5 3.4.6 2.2.2 28.0 20.0 20.0 32.0 32.0 32.0 46 DCB 65 / 65s 3.3 2.6 4.3 3.6 4.6 3.5 4.6 2.5 3.4.6 2.2.2 37.0 29.0 29.0 40.0 40.0 40.0 46 DCB 303 32.8 3.0 35.8 33.4 35.8 33. 33.2 30.7 32.8 30.3 29.9 27.5 9.0 5.0 5.0 2.0 2.0 2.0 46 DCB 304 / 304s 32.8 3.0 35.8 33.4 35.8 33. 33.2 30.7 32.8 30.3 29.9 27.5 28.0 20.0 20.0 3.0 3.0 3.0 46 DCB 305 / 305s 32.8 3.0 35.8 33.4 35.8 33. 33.2 30.7 32.8 30.3 29.9 27.5 38.0 28.0 28.0 42.0 42.0 42.0 46 DCB 307s 32.8 3.0 35.8 33.4 35.8 33. 33.2 30.7 32.8 30.3 29.9 27.5 43.0 32.0 32.0 47.0 47.0 47.0 46 ) Drying capacity is based on following moisture content test standards before and after drying: R34a: 050 50 ppm W R404A, R507: 020 50 ppm W R407C: 020 50 ppm W R40A: 050 50 ppm W R22: 050 60 ppm W In accordance with ARI 70-2004 2 ) Given in accordance with ARI 70-2004 for t e= -5 C t c= 30 C Δp = 0.07 bar For technical data on other refrigerants, please contact your Danfoss Sales Representative Ordering DMB flare Conn. Multi pack [in.] [mm] Qty. Code no. DMB 082 4 6 24 023Z42 DMB 083 3 8 0 24 023Z4 DMB 084 2 2 24 023Z40 DMB 62 4 6 2 023Z46 DMB 63 3 8 0 2 023Z45 DMB 64 2 2 2 023Z44 DMB 65 5 8 6 2 023Z43 DMB 303 3 8 0 8 023Z49 DMB 304 2 2 8 023Z48 DMB 305 5 8 6 8 023Z47 Danfoss 23Z8403 DCB flare Conn. Multi pack [in.] [mm] Qty. Code no. DCB 082 4 6 24 023Z402 DCB 083 3 8 0 24 023Z40 DCB 084 2 2 24 023Z400 DCB 62 4 6 2 023Z406 DCB 63 3 8 0 2 023Z405 DCB 64 2 2 2 023Z404 DCB 65 5 8 6 2 023Z403 DCB 303 3 8 0 8 023Z409 DCB 304 2 2 8 023Z408 DCB 305 5 8 6 8 023Z407 Danfoss DCS (za) 206.04 DKRCC.PD.ED0.D4.02 520H098 3

Ordering (continued) DMB Solder (cu-plated steel connectors) Conn. Multi pack Industrial pack Conn. Multi pack [in.] Qty. Code no. Qty. Code no. [mm] Qty. Code no. DMB 082s 4 24 023Z473 6 24 023Z46 DMB 083s 3 8 24 023Z472 6 023Z672 0 24 023Z459 DMB 084s 2 24 023Z47 6 023Z67 2 24 023Z457 DMB 63s 3 8 2 023Z476 2 023Z676 0 2 023Z455 DMB 64s 2 2 023Z475 2 023Z675 2 2 023Z453 DMB 65s 5 8 2 023Z474 2 023Z674 DMB 303s 3 8 8 023Z48 DMB 304s 2 8 023Z479 2 8 023Z45 DMB 305s 5 8 8 023Z478 8 023Z487 DMB 307s 7 8 8 023Z477 8 023Z498 DMB 309s 8 8 023Z493 DCB Solder (cu-plated steel connectors) Conn. Multi pack Industrial pack Conn. Multi pack [in.] Qty. Code no. Qty. Code no. [mm] Qty. Code no. DCB 082s 4 24 023Z464 DCB 083s 3 8 24 023Z463 0 24 023Z458 DCB 084s 2 24 023Z462 DCB 63s 3 8 2 023Z467 DCB 64s 2 2 023Z466 2 023Z666 2 2 023Z452 DCB 65s 5 8 2 023Z465 2 023Z665 DCB 304s 2 8 023Z470 DCB 305s 5 8 8 023Z469 DCB 307s 7 8 8 023Z468 Danfoss DCS (za) 206.04 DKRCC.PD.ED0.D4.02 520H098 4

Identification codes Codes Description Filter drier D Drier Solid core Application B Bi-flow Filter housing volume (approx.) Connection (filter connection in 8 of an inch increments) Connection type C M 08 8 in. 3 6 6 in. 3 30 30 in. 3 80% Molecular Sieve / 20% activated alumina 00% Molecular Sieve core 2 4 in. / 6 mm 3 3 8 in. / 0 mm 4 2 in. / 2 mm 5 5 8 in. / 6 mm 7 7 8 in. / 22 mm 9 8 in. (blank) s Solder connection (cu-plated steel connector) Example for type codes D M B 6 4 s Filter drier Solid core Application Size (volume) Connection (filter connection in 8 of an inch increments) Connection type Construction / flow direction Danfoss DCS (za) 206.04 DKRCC.PD.ED0.D4.02 520H098 5

Selection selection is made considering the application Refrigerant and oil types DCB DMB HFO Recommended Recommended Refrigerant HC ) Recommended Recommended HFC Recommended Recommended HCFC Recommended Recommended Mineral or AB Recommended Recommended Oil POE or PAG, pure Recommended Recommended POE or PAG, with additives Not recommended 2 ) Recommended ) Only solder versions (cu-plated / pure copper) and connection sizes below 25 mm are approved for flammable refrigerants now 2 ) DCB Hermetic filter driers contain activated alumina, which is a polar material used for acid adsorption. Many oil additives are also polar substances and can be adsorbed by the activated alumina, rendering them useless, and reducing the drier s acid capacity, though this is not harmful to the system Selection example Select the appropriate type (DMB or DCB) based on refrigerant and oil type. Then select the drier size based on the adsorption and liquid capacity required. a. Amount of charge: 5 kg R34a at tl = 24 C To dry 5 kg R34a at 24 C from 050 to 60 ppm moisture, a DMB 6 is necessary b. Cooling capacity: Qe = 25 kw To obtain a mass flow corresponding to 25 kw cooling capacity with a DMB 6 filter drier, a 2 inch connection must be chosen. Larger connections can be chosen in accordance with the liquid line dimension c. Result DMB 64 or DMB 65 can be used If the initial moisture content is very small or a planned change of the filter drier is considered, a smaller filter drier size can be chosen. Drying capacity [kg] refrigerant ) Liquid capacity [kw] 2 ) Max. R34a R404A R507 R22 R407C R40A Working Pressure [ C] R34a R404A R507 R22 R407C R40A PS 24 52 24 52 24 52 24 52 24 52 24 52 [bar] DMB 082/082s 9. 8.6 9.7 9.2 9.9 9.2 9.2 8.5 9. 8.4 8.3 7.6 3.9 2.8 2.8 4.3 4.3 4.3 46 DMB 083/083s 9. 8.6 9.7 9.2 9.9 9.2 9.2 8.5 9. 8.4 8.3 7.6 7.4 5.3 5.3 8.2 8.2 8.2 46 DMB 084/084s 9. 8.6 9.7 9.2 9.9 9.2 9.2 8.5 9. 8.4 8.3 7.6 8.3 6.0 6.0 9.2 9.2 9.2 46 DMB 62 7. 6.2 8.4 7.4 8.7 7.3 7.3 6.0 7. 5.8 5.6 4.4 7.6 5.3 5.3 8.8 8.8 8.8 46 DMB 63/63s 7. 6.2 8.4 7.4 8.7 7.3 7.3 6.0 7. 5.8 5.6 4.4 8.0 3.0 3.0 20.0 20.0 20.0 46 DMB 64/64s 7. 6.2 8.4 7.4 8.7 7.3 7.3 6.0 7. 5.8 5.6 4.4 28.0 20.0 20.0 32.0 32.0 32.0 46 DMB 65/65s 7. 6.2 8.4 7.4 8.7 7.3 7.3 6.0 7. 5.8 5.6 4.4 37.0 29.0 29.0 40.0 40.0 40.0 46 DMB 303 42.0 39.7 45.2 42.8 46.0 42.5 42.5 39.3 42. 38.9 38.3 35.3 9.0 5.0 5.0 2.0 2.0 2.0 46 DMB 304/304s 42.0 39.7 45.2 42.8 46.0 42.5 42.5 39.3 42. 38.9 38.3 35.3 28.0 20.0 20.0 3.0 3.0 3.0 46 DMB 305/305s 42.0 39.7 45.2 42.8 46.0 42.5 42.5 39.3 42. 38.9 38.3 35.3 38.0 28.0 28.0 42.0 42.0 42.0 46 DMB 307s 42.0 39.7 45.2 42.8 46.0 42.5 42.5 39.3 42. 38.9 38.3 35.3 43.0 32.0 32.0 47.0 47.0 47.0 46 Danfoss DCS (za) 206.04 DKRCC.PD.ED0.D4.02 520H098 6

Dimensions and weights s A L D D 2 Net weight [mm] [mm] [mm] [mm] [Kg] DMB/DCB 082 03 47 58 54 0.50 DMB/DCB 083 03 60 58 54 0.50 DMB/DCB 084 03 68 58 54 0.60 DMB/DCB 62 2 56 80 76 0.80 DMB/DCB 63 2 69 80 76 0.80 DMB/DCB 64 2 77 80 76 0.90 DMB/DCB 65 2 86 80 76 0.90 DMB/DCB 303 88 245 80 76.0 DMB/DCB 304 88 253 80 76.2 DMB/DCB 305 88 262 80 76.2 Solder connection (cu-plated steel connectors) A B L D D 2 Net weight [mm] [mm] [mm] [mm] [mm] [Kg] DMB/DCB 082s 03 9 35 58 54 0.50 DMB/DCB 083s 03 22 4 58 54 0.50 DMB/DCB 084s 03 24 45 58 54 0.60 DMB/DCB 63s 2 3 50 80 76 0.80 DMB/DCB 64s 2 33 54 80 76 0.80 DMB/DCB 65s 2 36 60 80 76 0.90 DMB/DCB 304s 88 209 230 80 76.00 DMB/DCB 305s 88 22 236 80 76.0 DMB/DCB 307s 88 24 250 80 76.0 DMB 309s 88 98 252 80 76.44 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary eady agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Danfoss DCS (za) 206.04 DKRCC.PD.ED0.D4.02 520H098 7