DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: VELUX AMERICA LLC POST OFFICE 5001 GREENWOOD, SOUTH CAROLINA 29648

Similar documents
DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: NATURAL LIGHT ENERGY SYSTEMS

DIVISION: METALS SECTION: COLD-FORMED METAL FRAMING REPORT HOLDER: WARE INDUSTRIES D/B/A MARINO\WARE

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued May 1, Legacy report on the 1997 Uniform Building Code

ESR ICC Evaluation Service, Inc. Issued December 1, 2006 This report is subject to re-examination in one year.

DIVISION: METALS SECTION: STEEL DECKING SECTION: STEEL FLOOR DECKING SECTION: STEEL ROOF DECKING REPORT HOLDER:

Trusted ICC ES. Conformity! Look. Evaluation. ICC-ES Evaluation

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: CONSOLIDATED SYSTEMS, INC. (CSi )

REPORT HOLDER: CLARKDIETRICH BUILDING SYSTEMS 9050 CENTRE POINTE DRIVE, SUITE 400 WEST CHESTER, OHIO EVALUATION SUBJECT:

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT. Skylight. VELUX America LLC

Originally Issued: 09/26/2012 Revised: 09/29/2017 Valid Through: 09/30/2018

continuous mounting flange intended for direct attachment to roofing substrate.

ICC-ES Evaluation Report

DIVISION: METALS SECTION: METAL FASTENINGS SECTION: STEEL DECKING REPORT HOLDER: ITW BUILDEX

Code Compliance Research Report CCRR-0258

ESR ICC Evaluation Service, Inc. Issued September 1, 2007 This report is subject to re-examination in one year.

EVALUATION SUBJECT: >B< MAXIPRO PRESS FITTINGS FOR AC AND REFRIGERATION APPLICATION

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: 2100 REXFORD ROAD CHARLOTTE, NORTH CAROLINA EVALUATION SUBJECT:

REPORT HOLDER: JAMES HARDIE BUILDING PRODUCTS INC ELM AVENUE FONTANA, CALIFORNIA EVALUATION SUBJECT:

Product Evaluation Report

Submittal Requirements for Product Evaluation - Doors

Equivalency Evaluation to 2010 FBC

EVALUATION SUBJECT: EPA WATERSENSE HUNTER INDUSTRIES WEATHER-BASED IRRIGATION CONTROLLERS

EVALUATION SUBJECT: CAST IRON SOIL PIPE AND FITTINGS

Equivalency Evaluation to 2010 FBC

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina

EVALUATION SUBJECT: GASTITE FLASHSHIELD METALLICALLY SHIELDED CORRUGATED STAINLESS STEEL TUBING

PRODUCT EVALUATION Effective Date: July 1, 2014 RC-20

Residential skylight sizes 2008 edition

Originally Issued: 09/09/2014 Revised: 09/13/2017 Valid Through: 09/30/2018

Not to be distributed outside of FM Approvals and its affiliates except by Customer

CITY OF LOS ANGELES CALIFORNIA

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT. Model A-FS-CM-SP Skylight Skyco Skylights

EVALUATION SUBJECT: KITCHEN AND VANITY CABINETS

EVALUATION SUBJECT: EPA WATERSENSE SHOWERHEADS

ESR-1414 Reissued October 1, 2011 This report is subject to renewal in one year.

CREEK Technical Services, LLC

EVALUATION SUBJECT: CERAMIC PLUMBING FIXTURES

CREEK Technical Services, LLC

SINGLE SLIDING WINDOW 1000 SERIES 4-1/2" FRAME SINGLE SLIDER LIFT OUT

National Evaluation Service, Inc.

AAMA/WDMA/CSA 101/I.S.2/A440-08

William R. Heiden III, P.E.

New Gateway 101/I.S.2/A440

%"!#!#%&'!# %##(%)"&#%$!!%'"%!'*%% SW 26 Street, Room 208,%! '#%# - '

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

ESR-1414 Reissued July 2014 This report is subject to renewal October 1, 2015.

FIXED SKYLIGHTS. A skylight in every shape and size. SERIES SI5006

CONSTRUCTION CONSULTING LABORATORY, INTERNATIONAL

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

SAVING ENERGY SEAMLESSLY FULLY ENCAPSULATED SKYLIGHT

DASMA DASMA

AAMA/WDMA/CSA 101/I.S.2/A440-08

western for products manufactured in White City, Oregon

ESR-2408 Reissued August 2014 This report is subject to renewal August 2015.

Structurlam Mass Timber Corporation Revised October 11, 2018

Meeting ENERGY STAR Version 6.0

International Codes. FREE with purchase of the IBC, IRC or IFC! TO ORDER PHONE(800) FAX (888)

American National Standard

TECHNICAL DATA SHEET Artisan Lap Siding

Quick Mount PV QBlock Mount System for use with SnapNrack Series 100 Roof Mount System SEI Project No.:

Commercial skylights. Dynamic Dome skylight. whyskylights.com

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings

EVCS Access California

SFI SPECIFICATION 27.1 EFFECTIVE: OCTOBER 11, 2006 *

TRUS JOIST BEAMS, HEADERS, AND COLUMNS

GENERATOR SHELTER IMPACT TEST REPORT (.08 Material)

SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 *

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

Evaluation Report CCMC R Ram Jack Helical Foundation Systems and Devices

Kolbe Teutonic Series Air-Water-Structural Test Reports Manual

SECTION DUCTWORK ACCESSORIES

Allowable Holes in VERSA-LAM Beams

LVL User s Guide. Technical Data for LVL Headers, Beams, Column Applications for Residential Floor and Roof Systems

SFI SPECIFICATION 35.1 EFFECTIVE: AUGUST 26, 2008 *

TEST REPORT. Report No.: G Rendered to: SKYCO SKYLIGHTS Costa Mesa, California

Eclipse C3 Aluminum Folding Door System. Dealer Brochure Exterior folding door systems


DEPARTMENT OF TRADE AND INDUSTRY NO APRIL 2016

A. This Section includes the following types of sectional overhead doors:

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

American National Standard for Lighting Equipment Voltage Surge Requirements

WA67 Folding System - Aluminum Clad Over Wood

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PVC Guardrail System Utilizing New Nylon/PVC Rail Mounting Bracket

BIRDVIEW SKYLIGHTS The Clear Choice

SFI SPECIFICATION 15.4 EFFECTIVE: JULY 20, 2010 * PRODUCT: Top Fuel and Funny Car Drag Race Drive Beadlock Wheels

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Maximum Span Tables. for Joists and Rafters. MSR Lumber. for Performance. Figure provided courtesy of the American Forest & Paper Association

TECH BULLETIN. SIP No. Subject: Fiber Cement Siding from James Hardie. Date: February 2010 (Revised November 2015)

SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 *

ENLIGHTENED LIVING RESIDENTIAL SKYLIGHTS E-CLASS CURB-MOUNT ARCHITECTURAL SERIES

Regulation of Commercial Waste Originators, Pumpers, Transporters, Processors, and Disposal Facilities

Residential Skylights. Supplemental Brochure

SKN_N0106AnnexJ_R2. Annex J - Specific requirements for PVT collector Certification. 1. Introduction and definition

3.0 RAIL-FREE RACKING. Utilizes EcoFasten Solar s patented technology

Net Metering Program

ARTICLE SAFETY CODES FOR ELEVATORS, ESCALATORS, MANLIFTS AND HOISTS. Elevator Safety

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

Artisan Siding with Lock Joint System

Transcription:

0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-4108 Issued 12/2017 This report is subject to renewal 12/2018. DIVISION: 08 00 00 OPENINGS SECTION: 08 62 00 UNIT SKYLIGHTS REPORT HOLDER: VELUX AMERICA LLC POST OFFICE 5001 GREENWOOD, SOUTH CAROLINA 29648 EVALUATION SUBJECT: VELUX DYNAMIC DOME SKYLIGHTS Look for the trusted marks of Conformity! 2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved.

ICC-ES Evaluation Report ESR-4108 Issued December 2017 This report is subject to renewal December 2018. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION: 08 00 00 OPENINGS Section: 08 62 00 Unit Skylights REPORT HOLDER: VELUX AMERICA LLC POST OFFICE BOX 5001 GREENWOOD, SOUTH CAROLINA 29648 (864) 941-5360 www.veluxusa.com vcustomer.service@velux.com commercialteam@velux.com EVALUATION SUBJECT: VELUX DYNAMIC DOME SKYLIGHTS 1.0 EVALUATION SCOPE Compliance with the following codes: 2015 and 2012 International Building Code (IBC) 2015 and 2012 International Residential Code (IRC) Properties evaluated: Structural Air infiltration Water penetration resistance Durability 2.0 USES The VELUX Dynamic Dome Skylights are non-operable plastic-glazed unit skylights complying with IBC Sections 2405 and 2610 and IRC Section R308.6. 3.0 DESCRIPTION 3.1 Single Dynamic Domes: The VELUX CDS Single Dynamic Domes consist of a single geometric-shaped plastic dome factory-attached to an aluminum extruded frame with an aluminum extruded retainer cap. The frame and retainer cap is manufactured from 0.06-inch-thick (1.52 mm) 6063-T5 aluminum. See Figure 1. The plastic dome is manufactured from a translucentwhite polycarbonate panel with a uniform thickness of 0.118 inch (3.00 mm). The panel is recognized as Covestro s Makrolon SK1 under ESR-2728. 3.2 Double Dynamic Domes: The VELUX CD2 and CE2 Double Dynamic Domes consist of double geometric-shaped plastic domes factoryattached to an aluminum extruded frame with an aluminum dome clamp and spring clips. The frame and dome clamp is manufactured from 0.06-inch-thick (1.52 mm) 6063-T6 aluminum. See Figure 2. The spring clip is manufactured from 301 stainless steel. The outer plastic dome is manufactured from a translucent-white or clear polycarbonate panel with a uniform thickness of 0.118 inch (3.00 mm). The inner plastic dome is manufactured from a translucent-white or clear polycarbonate panel with one side prismatic with a thinnest thickness of 0.053 inch (overall thickness of 0.118-inch). The prismatic side faces the exterior. The panels are recognized as Covestro s Makrolon SK1 (outer) and SK (inner) under ESR-2728. 4.0 DESIGN AND INSTALLATION 4.1 Design: 4.1.1 Performance Grade: The performance grade (PG) ratings are provided in Tables 1 and 2. 4.1.2 Air Infiltration: When tested at an air pressure differential of 1.57 psf (75 Pa), the skylights have an air leakage rate of less than 0.30 cfm/ft 2 (1.5 L/s*m 2 ). 4.2 Installation: The skylight must be attached with minimum No. 8 corrosion-resistant wood screws in each mounting hole provided in the skylight frame, with the screw length being sufficient to penetrate a wood curb a minimum of 1 inch (25 mm). See Tables 1 and 2 for the required number of fasteners. Additional installation details are provided in Figures 1 through 3. The skylights are curb-mounted and must be installed on a minimum 2-by lumber with a minimum specific gravity of 0.42, sized to the inside dimension noted in Table 1, and of a height sufficient so that the plastic glazing is a minimum of 4 inches (102 mm) above the plane of the roof. The wood curb and its attachment to the roof structure must be designed to resist wind uplift and gravity loads. Flashing must comply with, and be installed in accordance with, IBC Section 1507 or IRC Section R905, as applicable. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 7

ESR-4108 Most Widely Accepted and Trusted Page 2 of 7 5.0 CONDITIONS OF USE The VELUX Dynamic Dome Skylights described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The skylights must be installed in accordance with this report, Sections 2405.4 and 2610 of the IBC or Section R308.6 of the IRC, as applicable, and the manufacturer s published installation instructions. In the event of a conflict between this report and the manufacturer s published installation instructions, this report governs. 5.2 The design pressure (performance grades) for the skylights are as set forth in Table 1 and Table 2, and must be used with the load combinations of the applicable code. 5.3 The manufacturer s installation instructions must be available at the jobsite during installation. 5.4 The use of the skylights as components of fireresistance-rated assemblies is outside the scope of this report. 5.5 The attachment of the curbs to the supporting structure is outside the scope of this report. 5.6 The use of skylights in wind-borne debris regions is outside the scope of this report. 5.7 The skylights are manufactured in Greenwood, South Carolina under a quality control program with inspections by ICC-ES. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Plastic-Glazed Skylights (AC16), dated April 2017. 7.0 IDENTIFICATION The skylights are labeled with the VELUX name and address; the Single Dynamic Dome or Double Dynamic Dome series; the model number and the product designation (SKP-PG30); the evaluation report number (ESR4108); and a safety label complying with Class I, ANSI Z 35.1-1972 (warning of risk of falling). MODEL NO. 1,2,3 TABLE 1 SINGLE DYNAMIC DOME SKYLIGHTS DOME RISE (inches) NUMBER OF RETAINER FASTENERS 4 NUMBER OF MOUNTING FASTENERS 5 CDS 4896 3P200 24 24 15 CDS 4848 3P200 16 16 For SI: 1 inch = 25.4 mm, 1 psf = 47.88 Pa 1. 2. 3. 4. 5. 6. PERFORMANCE GRADE (PG) 6 (psf) PG pos (inward forces) PG neg (outward forces) 30 30 CDS = mill-finished frame The numbers in the middle are the nominal inside curb dimensions in inches, width by length. 3P200 = white polycarbonate dome The retainer fasteners must be #10 by 5 "-long pan head screws. The screws must not be spaced greater than 7 1 / 2" from the corners nor 12" o.c. The mounting fasteners must be #8 by 1 3 / 4"-long pan head screws. The screws must not be spaced greater than 8 1 / 2" from the corners nor 12" o.c. Production designation = SKP-PG30 (SK1) (SK1) CDS 4896 3P200 6 CDS 4848 3P200 2 FIGURE 1A SINGLE DYNAMIC DOME FIGURE 1B SINGLE DYNAMIC DOME SIDE AND TOP VIEWS FOR 48-INCH-WIDE SKYLIGHTS

ESR-4108 Most Widely Accepted and Trusted Page 3 of 7 TABLE 2 DOUBLE DYNAMIC DOME SKYLIGHTS MODEL NO. 1,2,3 DOME RISE (inches) INNER OUTER NUMBER OF RETAINER FASTENERS 4 NUMBER OF MOUNTING FASTENERS 5 NUMBER OF SPRING CLIPS 6 CD2 4896 3P1C1 or CE2 4896 3P1C1 6 24 24 CD2 4872 3P1C1 or CE2 4872 3P1C1 6 20 20 14 15 CD2 4860 3P1C1 or CE2 4860 3P1C1 4 18 18 CD2 4848 3P1C1 or CE2 4848 3P1C1 4 16 16 CD2 3696 3P1C1 or CE2 3696 3P1C1 6 22 22 CD2 3672 3P1C1 or CE2 3672 3P1C1 10 3 11 3 6 18 18 CD2 3660 3P1C1 or CE2 3660 3P1C1 4 16 16 CD2 3636 3P1C1 or CE2 3636 3P1C1 4 12 12 CD2 2496 3P1C1 or CE2 2496 3P1C1 6 5 7 5 6 20 20 CD2 2448 3P1C1 or CE2 2448 3P1C1 4 12 12 CD2 4896 3P1C2 or CE2 4896 3P1C2 6 24 24 CD2 4872 3P1C2 or CE2 4872 3P1C2 6 20 20 14 15 CD2 4860 3P1C2 or CE2 4860 3P1C2 4 18 18 CD2 4848 3P1C2 or CE2 4848 3P1C2 4 16 16 CD2 3696 3P1C2 or CE2 3696 3P1C2 6 22 22 CD2 3672 3P1C2 or CE2 3672 3P1C2 10 3 11 3 6 18 18 CD2 3660 3P1C2 or CE2 3660 3P1C2 4 16 16 CD2 3636 3P1C2 or CE2 3636 3P1C2 4 12 12 CD2 2496 3P1C2 or CE2 2496 3P1C2 6 5 7 5 6 20 20 CD2 2448 3P1C2 or CE2 2448 3P1C2 4 12 12 PERFORMANCE GRADE (PG) 7 (psf) PG pos (inward forces) PG neg (outward forces) 30 30 30 30 CD2 4896 3P2C1 or CE2 4896 3P2C1 6 24 24 CD2 4872 3P2C1 or CE2 4872 3P2C1 6 20 20 14 15 CD2 4860 3P2C1 or CE2 4860 3P2C1 4 18 18 CD2 4848 3P2C1 or CE2 4848 3P2C1 4 16 16 CD2 3696 3P2C1 or CE2 3696 3P2C1 6 22 22 CD2 3672 3P2C1 or CE2 3672 3P2C1 10 3 11 3 6 18 18 CD2 3660 3P2C1 or CE2 3660 3P2C1 4 16 16 CD2 3636 3P2C1 or CE2 3636 3P2C1 4 12 12 CD2 2496 3P2C1 or CE2 2496 3P2C1 6 5 7 5 6 20 20 CD2 2448 3P2C1 or CE2 2448 3P2C1 4 12 12 For SI: 1 inch = 25.4 mm, 1 psf = 47.88 Pa 1. 2. 3. 4. 5. 6. 7. 30 30 CD2 = mill-finished frame; CE2 = powder-coated frame The numbers in the middle are the inside curb dimensions in inches, width by length. 3P1C1 = clear outer dome / clear inner dome with a prismatic side; 3P1C2 = clear outer dome / white inner dome with a prismatic side; 3P2C1 = white outer dome / clear inner dome with a prismatic side The retainer fasteners must be #10 by 5 "-long pan head screws. The screws must be used in all pre-drilled holes in the dome clamp. The mounting fasteners must be #8 by 1 3 / 4"-long pan head screws. The screws must not be spaced greater than 8 1 / 2" from the corners nor 12" o.c. Spring clips must not be spaced greater than 4 7 " from the corners nor 12" o.c. Production designation = SKP-PG30

ESR-4108 Most Widely Accepted and Trusted Page 4 of 7 (SK) (SK1) FIGURE 2A DOUBLE DYNAMIC DOME FIGURE 2B RETAINER SPRING CLIP 4848 2 3636 0 FIGURE 2C DOUBLE DYNAMIC DOMES SIDE AND TOP VIEWS FOR SQUARE SKYLIGHTS 4896 6 4872 4 4860 3 FIGURE 2D DOUBLE DYNAMIC DOMES SIDE AND TOP VIEWS FOR 48-INCH-WIDE RECTANGULAR SKYLIGHTS

ESR-4108 Most Widely Accepted and Trusted Page 5 of 7 3696 5 3672 3 3660 2 FIGURE 2E DOUBLE DYNAMIC DOMES SIDE AND TOP VIEWS FOR 36-INCH-WIDE RECTANGULAR SKYLIGHTS 2496 6 2448 2 FIGURE 2F DOUBLE DYNAMIC DOMES SIDE AND TOP VIEW FOR 24-INCH-WIDE RECTANGULAR SKYLIGHTS

ICC-ES Evaluation Report ESR-4108 CBC and CRC Supplement Issued December 2017 This report is subject to renewal December 2018. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION: 08 00 00 OPENINGS Section: 08 62 00 Unit Skylights REPORT HOLDER: VELUX AMERICA LLC POST OFFICE BOX 5001 GREENWOOD, SOUTH CAROLINA 29648 (864) 941-5360 www.veluxusa.com vcustomer.service@velux.com commercialteam@velux.com EVALUATION SUBJECT: VELUX DYNAMIC DOME SKYLIGHTS 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that VELUX Dynamic Dome Skylights, recognized in ICC-ES master evaluation report ESR-4108, have also been evaluated for compliance with the codes noted below. Applicable code editions: 2016 California Building Code (CBC) 2016 California Residential Code (CRC) 2.0 CONCLUSIONS 2.1 CBC: The VELUX Dynamic Dome Skylights described in Sections 2.0 through 7.0 of the master evaluation report ESR-4108, comply with CBC Sections 2405 and 2610, provided the design and installation are in accordance with the 2015 International Building Code (IBC) provisions noted in the master report and the additional requirements of CBC Chapters 24 and 26, as applicable. The VELUX Dynamic Dome Skylights have not been evaluated under CBC Chapter 7A for use in the exterior design and construction of new buildings located in any Fire Hazard Severity Zone within a State Responsibility Areas or any Wildland Urban Interface Fire Area. 2.2 CRC: The VELUX Dynamic Dome Skylights, described in Sections 2.0 through 7.0 of the master evaluation report ESR-4108, comply with CRC Section R308.6, provided the design and installation are in accordance with the 2015 International Residential Code (IRC) provisions noted in the master report. The VELUX Dynamic Dome Skylights have not been evaluated under CRC Section R337 for use in the exterior design and construction of new buildings located in any Fire Hazard Severity Zone within a State Responsibility Areas or any Wildland Urban Interface Fire Area. The products recognized in this supplement have not been evaluated for compliance with the International Wildland Urban Interface Code. This supplement expires concurrently with the master report, issued December 2017. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved. Page 6 of 7

ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-4108 FBC Supplement Issued December 2017 This report is subject to renewal December 2018. A Subsidiary of the International Code Council DIVISION: 08 00 00 OPENINGS Section: 08 62 00 Unit Skylights REPORT HOLDER: VELUX AMERICA LLC POST OFFICE BOX 5001 GREENWOOD, SOUTH CAROLINA 29648 (864) 941-5360 www.veluxusa.com vcustomer.service@velux.com commercialteam@velux.com EVALUATION SUBJECT: VELUX DYNAMIC DOME SKYLIGHTS 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that VELUX Dynamic Dome Skylights, recognized in ICC-ES master evaluation report ESR-4108, has also been evaluated for compliance with the codes noted below. Applicable code editions: 2017 Florida Building Code Building 2017 Florida Building Code Residential 2.0 CONCLUSIONS The VELUX Dynamic Dome Skylights, described in Sections 2.0 through 7.0 of the master evaluation report ESR-4108, comply with the Florida Building Code Building and Florida Building Code Residential, provided the design and installation are in accordance with the 2015 International Building Code provisions noted in the master report subject to the following condition: Use of VELUX Dynamic Dome Skylights in wind-borne debris regions is outside the scope of this supplement. Use of the VELUX Dynamic Dome Skylights for compliance with the High-Velocity Hurricane Zone provisions of the Florida Building Code Building and Florida Building Code Residential has not been evaluated and is outside the scope of this supplemental report. For products falling under Florida Rule 9N-3, verification that the report holder s quality assurance program is audited by a quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, issued December 2017. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved. Page 7 of 7