Installation Guide. Philips MP20/30/40/50 IntelliVue VHM Wall Mount Kit

Similar documents
Installation Guide VHM Wall Mount Kit for Philips MX600/700/800 and MP60/70 IntelliVue

Installation Guide VHM Arm Kit for Philips Heartstart MRx and Heartstart XL+

Installation Guide. Philips IntelliVue MP20/30/40/50/60/70, MX400/450/600/700/800 Low Profile Camlock Mount

Installation Guide Philips MP2 IntelliVue M-Series Arm (12'' or 8'') Rail Mount Kit

Installation Guide Stack Mount Kit for Philips G5 and MP5/20/30/40/50/60/70 Monitor

Installation Guide Roll Stand Kit for Philips MP20/30 Monitor

Installation Manual for Philips Intellivue MP5/20/30 VHM-25 Channel Mount Kit

GCX Mounting Assembly Installation Guide. Philips MP90 (M8010A) Mounting Kit for Drager Zeus

Installation Manual for Philips SureSigns VS3/VS4/VM4/VM6/VM8/VSV VHM-25 Countertop Mount

Installation Guide Philips MP90 VHM Wall Mount Kit

(Refer to qualified personnel)

VHM-P (Non-Locking) Variable Height Arm with VESA Mounting Plate for 75 x 75mm or 100 x 100mm applications

Installation Guide Roll Stand Kit 2''/5.1cm Diameter Post with Tilt/Swivel Mounting Plate, Handle, Utility Basket and 10lbs/4.

3875 Cypress Drive Petaluma, CA Fax

VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate

Installation Guide GE Healthcare Carescape Dual Display Roll Stand Kit

Installation Guide Philips MP90 Dual Display Mounting Kit for Dräger Apollo Anesthesia Machine

Installation Guide Philips MP90 Mounting Kit with 16'' M-Series Arm for Datex Ohmeda Avance Anesthesia Machine

Installation Guide GE Healthcare Carescape Single Display Roll Stand Kit

Installation Guide Folding L-Bracket with Display Mounting Extension and Keyboard Tray for M-Series or VHM Arm

Installation Manual for VHM-25 Series Arms Channel Mount

Installation Guide. Xprezzon Roll Stand

Installation Guide LiDCO Hemodynamic Monitor - Roll Stand Kit (US Version)

Installation Guide LiDCO Hemodynamic Monitor - Roll Stand Kit (EURO Version)

GCX Mounting Assembly Operation/Installation Manual

Installation Guide GE Mini Telemetry Receiver Rear Column Mount

GE CARESCAPE Monitor B650 on VHM- PL Variable Height Arm Channel Mount with Vertical Position Lock

Installation Guide Variable Height Roll Cart for Corometrics/GE 250 Series Fetal Monitor with Dual Displays and Keyboard Mounts

Installation Guide Corometrics/GE 250 Series Fetal Monitor Roll Cart with Laptop and Display Mounts

Installation Guide. Philips MP90 M-Series Wall Mount Kit (12'' Pivot Arm) Section 1.0: Mounting the M-Series Arm Parts Reference...

Condor Manual. Corporation

3875 Cypress Drive Petaluma, CA Fax

GCX Mounting Assembly Installation Guide Philips MP90 (with AGM) Mounting Kit for Datex Ohmeda Aestiva Anesthesia Machine

Installation Instructions. ARS (Amico Rail Systems)

RMK HANDLEBAR KIT P/N ; ; APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

SERVICE BULLETIN SB.DSL rev02

FireHawk M7XT Ultra Elite XT Facepiece

INSTALLATION MANUAL FOR PILOT WORKSTATION

GENUINE PARTS INSTALLATION INSTRUCTIONS

TOYOTA TUNDRA BUMPER STEP ASSIST Preparation

Maintenance Information

Universal Pitch Adjustable Wall Mount For Flat Panel Display UPM-2401

FOR SIT-STAND WORKSTATION

TOYOTA TUNDRA BUMPER STEP ASSIST Preparation

Installation Instructions BR20 Rear Bumper Replacement Part # 28178T Toyo ta Tundra 2/4WD

Ultra Elite Facepiece: AirHawk II Air Mask

Maintenance Information

Introduction. Pressed Shaft Flowmeter. Flowmeter Service Kits. Disassembly. Idler Shaft Removal

Chrysler 727, 904, 518 Floor Mount Automatic Transmission Shifter Installation Instructions

w w w. h d o n l i n e s h o p. d e CRUISE CONTROL KIT GENERAL INSTALLATION -J04064 REV Kit Number Models Additional Parts Required

Assembly Instructions

INSTALLATION INSTRUCTIONS ELEVATION FRONT BUMPER 2018 FORD F150

Installation Instructions

INSTALLATION INSTRUCTIONS South Highway 11 Westminster, SC Toll Free (888) (864) FAX (864)

INSTALLATION INSTRUCTIONS GRILLE GUARD SILVERADO 1500 PART #

E Series Enclosures Installation Instructions (UL /UL2416 E Series Equipment Cabinet/Rack)

CorkSport ort Mazda 3 Adjustable Shifter Mazdaspeed 3, Mazda 3 6-speed and Mazda3 SkyActiv 6-speed

Instruction Sheet. Kit Numbers: , , & CRANK PULLEY KIT DISASSEMBLY. Package Contents

Motion System Components Diagram. Note: #2 Mirror Cover and X-Axis Motor Cover have been removed for visibility. Maintenance.

N/S= Not Shown Bold = Part available for purchase. Italic = Part not available for purchase, listed and shown for reference only.

Maintenance Information

INSTALLATION INSTRUCTIONS

GM 6-Cylinder Cam Tool Set 3.0L and 3.2L Operating Instructions

INSTALLATION INSTRUCTIONS

TABLE OF CONTENTS I. SERVICE & MAINTENANCE PROCEDURES. 1) Opening and closing of door latch. 2) Latch assembly and adjustment

Discount-Equipment.com

INSTALLATION INSTRUCTIONS

FOR FUTURE REFERENCE SERIES 93HPS

E-200 O-rings Service Kit

INSTALLATION INSTRUCTIONS BULL BAR DODGE RAM 1500 PART # B-D1091;B-D2091

Avoid damage to the motorcycle. Protect painted surfaces with a soft cloth or blanket.

INSTALLATION INSTRUCTIONS GRILLE GUARD GMC SIERRA 1500 EXCLUDES DENALI PART # 4084/

160S Rewind Option Kit Installation Instructions

Ultra Elite Facepiece

INSTALLATION INSTRUCTIONS RATTLER STEEL RUNNING BOARDS FORD TRANSIT VAN (FULL SIZE)

Product Description. Product Numbers. Warning/Caution Notations. Required Tools. Wiring. Prerequisites

PARTS LIST: HEAVY DUTY FRONT BUMPER FORD SUPERDUTY F

9-I DUETTE SHADES POWERVIEW MOTORISATION

Installation Manual TWM Performance Short Shifter Cobalt SS/SC, SS/TC, HHR SS, Ion Redline and Saab 9-3

Rollstar Shade Installation Instructions

Plasma Dual Swing-Out (PDS Series) Wall Mount

INSTALLATION INSTRUCTIONS South Highway 11 Westminster, SC Toll Free (888) (864) FAX (864)

STEERING COLUMN - TILT

AIM LED LIGHT (wall mount)

Installation Instructions Series

401B/1KDB CoolRite/FreezeRite Installation Manual I003

Lights TURN SIGNAL/SIDE MARKER LIGHT/ PARKING LIGHT HIGH BEAM HEADLIGHT LOW BEAM HEADLIGHT CONTINUED FOG LIGHT. Maintenance 257

3PC TONNEAU COVER INSTALLATION INSTRUCTIONS. Ford Ranger/Mazda BT-50 (without bedliner)

INSTALLATION INSTRUCTIONS

Installation Instructions. QuickSilver Shifter. Fits: GM, Ford, Chrysler Transmissions See Application Guide for Specific Applications Part # 80683

M Damper Mount Linkage Kit Installation. Item Description Quantity Item Description Quantity Nuts 2

FRONT STABILIZER BAR KIT

INSTALLATION INSTRUCTIONS

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION

Introduction. The words WARNING, CAUTION and NOTE carry special meanings and should be carefully reviewed.

INSTALLATION INSTRUCTIONS WHEEL-TO- WHEEL

INSTALLATION INSTRUCTIONS

TOYOTA PRIUS XM SATELLITE RADIO Preparation

Tooling Assistance Center

IV STANDS. Assembly, Usage and Maintenance INSTRUCTION MANUAL

Transcription:

Installation Guide Philips MP20/30/40/50 IntelliVue VHM Wall Mount Kit The purpose of this guide is to: 1. Describe attachment of Table Top Mount to Mounting Adapter. 2. Describe attachment of Mounting Adapter to VHM Arm. 3. Describe mounting of VHM Arm in the Wall Channel. 4. Describe mounting the monitor on the Arm. 5. Describe Operation and Adjustment of VHM Arm. Parts Reference The following parts and hardware are included with this installation kit (hardware not shown): Item # Description Qty 1 VHM Arm with Mounting Adapter 1 2 Locking Lever, Height Adjustment 1 3 Cable Clip, VHM Arm 2 4 M6 x 8mm FHMS 2 5 M6 x 12mm FHMS 1 6 1/8'' Hex Wrench 7 5/32'' [4mm] Hex Wrench 1 8 Wall Channel Cover, 16'' 1 9 1/2'' Socket Wrench 1 *10 Spacer, MP20/30 1 *11 M6 x 16mm Pan Head Machine Screw (PHMS) 2 1 10 3 2 *See "MP20/30 with non-table Top Mount" (page 3) for use of these parts. Tools Required Phillips screwdriver (not provided), 1/8'' and 5/32'' [4mm] hex wrenches (provided), 1/2'' socket wrench (provided). WARNING! The VHM Arm contains a strong spring which is used to counterbalance the weight of the mounted device. The Arm housing should never be disassembled by non-gcx personnel. Additionally, the mounted device should only be removed with the Arm in its highest vertical position, with the Height Locking Lever in the fully locked position. Failure to follow these guidelines could result in serious injury. Before mounting the Arm: 1. Note that this arm has a wide range of motion both up/down and side to side. Please consider carefully the device being mounted and the proximity of the assembly to other equipment, hospital personnel, and the patient. GCX recommends that the hospital s risk management personnel verify the appropriateness of the application prior to installation and use. 2. If assistance is needed regarding an application, please contact a GCX product specialist at (800) 228-2555. DU-AG-0021-25 Rev B 7/17/06 GCX Corp Page 1 of 6

Attaching the Philips-supplied Table Top Mount to the Mounting Adapter Installation Note: Do not attach the Table Top Mount to the Arm/Mounting Adapter if you will be mounting an MP20/30 monitor with the mounting interface shown in photo (right). See "Mounting the Monitor" (page 3) for instructions specific to this type of mounting interface. Do Not Attach Table Top Mount if MP20/30 Monitor Has This Mounting Interface 1. Fasten Philips-supplied Table Top Mount to Mounting Adapter with one (1) M6 x 12mm FHMS and two (2) M6 x 8mm FHMS (see below). Mounting Adapter M6 X 12mm FHMS (1) M6 X 8mm FHMS (2) Table Top Mount Mounting VHM Arm in Wall Channel 1. Thread the Height Locking Lever into the mounting hole in the right side of the Arm. The Lever operates by turning clockwise to tighten or counterclockwise to loosen. Ensure that the Locking Lever is in the locked position before mounting the Arm in the channel. Height Locking Lever DU-AG-0021-25 Rev B 7/17/06 GCX Corp Page 2 of 6

2. While supporting the bottom of the Arm, guide the Slide into the top of the wall channel (below left) and move Arm to required mounting position. 3. Using the 1/8'' hex wrench provided, tighten four (4) set screws in Slide to secure position of Arm (below right). Set Screws (2 upper) Insert Slide Set Screws (2 lower) Mounting the Monitor 1. Mount the monitor in accordance with Philips Table Top Mount instructions, or follow procedure below for non-table top mount. Proceed to "Counterbalance Adjustment" on page 4. MP20/30 with non-table Top Mount 1. Fit Spacer into recessed area on top of Mounting Adapter (below). Ensure Spacer remains between Mounting Adapter and monitor. 2. Insert two (2) M6 x 16mm PHMS through bottom of Mounting Adapter and thread into mounting holes in bottom of monitor (right). Spacer Mounting Adapter DU-AG-0021-25 Rev B 7/17/06 GCX Corp Page 3 of 6

Counterbalance Adjustment The VHM Arm must be adjusted to counterbalance the mounted instrument throughout the Arm s vertical range of motion. When properly counterbalanced, the VHM Arm will maintain its height when the Locking Lever is disengaged. Because instrument weights vary, some adjustment is required to achieve optimal performance. Use Caution while performing this procedure. Do not attempt counterbalance adjustment unless the instrument and accessories are mounted on the Arm. 1. Grasp the Arm behind the mounted instrument(s) to prevent sudden upward motion. Carefully unlock the Arm and move it to a horizontal position that allows access to the Adjuster Cover (below left). Lock Arm in horizontal position. 2. Open the Adjuster Cover by inserting a flat blade screwdriver in the slot at the rear of the Cover and prying upward. If necessary unlock and readjust the Arm until the Counterbalance Adjuster bolt is accessible through the Adjuster Cover (below center). Lock Arm when Counterbalance Adjuster is accessible. 3. With the 1/2" [13mm] socket wrench on the Adjuster, carefully unlock the arm. Turn the Adjuster counterclockwise (CCW) to increase counterbalance force, or clockwise (CW) to decrease counterbalance force. Counterbalance is correctly adjusted when the mounted instrument can be moved up or down with minimal force and does not rise or fall after releasing the Arm. Close Adjuster Cover. 1/2'' [13 mm] Socket Wrench Counterbalance Adjuster Bolt Adjuster Cover CW Decreases Force CCW Increases Force 4. Check the pivot, tilt, and swivel functions for proper tension. If adjustments are required, refer to the "VHM Arm Operation & Adjustment" on pages 5-6. DU-AG-0021-25 Rev B 7/17/06 GCX Corp Page 4 of 6

Cable Management Two (2) Molded Cable Guides are provided to facilitate routing of cables along the underside of the arm. Squeeze the Cable Guide until its edges snap into the grooves in the bottom surface of the arm. Leave extra cable loose at the front and rear of the arm to prevent cable binding or damage to connectors. Cable Guides (2) Installing the 16'' Wall Channel Cover Install the Wall Channel Cover in accordance with the Channel Cover Installation Guide (DU-UT-0001-20). VHM Arm Operation & Adjustment Swiveling the Mounted Instrument and Adjusting Swivel Tension 1. To swivel the mounted instrument simply push or pull the corners of the instrument. 2. To adjust swivel tension, remove bolt cap or existing Down Post from Swivel Cup (bottom of front end of Arm). Tighten or loosen the Swivel Tension Bolt using a 1/2'' [13 mm] socket wrench. Swivel Tension Tilting the Mounted Instrument and Adjusting Tilt Tension 1. To tilt the instrument, grasp the top and bottom of the instrument and tilt it to the desired angle. 2. To adjust tilt tension, equally tighten or loosen the two (2) Tilt Tension screws using the 5/32'' hex wrench provided. Tilt Tension Screws (2) Pivoting the Arm and Adjusting Pivot Tension 1. To pivot Arm at Channel, simply push on side of Arm. 2. To adjust pivot tension, remove top and bottom plastic bolt caps from Pivot Bolt. Using the 1/2" [13mm] socket wrench provided and a 1/2'' [13mm] box or open-end wrench, tighten or loosen Pivot Bolt and Hex Nut to desired tension. Reinstall bolt caps back over each end of Pivot Bolt. 1/2" [13 mm] Box-end Wrench 1/2" [13 mm] Socket Wrench DU-AG-0021-25 Rev B 7/17/06 GCX Corp Page 5 of 6

Height Adjustment Caution: Do not attempt to adjust height without instrument being mounted. 1. Loosen the Height Locking Lever by rotating it counterclockwise. 2. Grasp the mounted instrument (or handle) and push up or pull down to the desired height. 3. Tighten the Height Locking Lever to lock the Arm in the desired position. Positioning VHM Arm in Channel 1. Lock the Arm position using the Height Locking Lever. 2. Using the 1/8'' hex wrench provided, loosen four (4) set screws in Slide. 3. Relieve the weight of the mounted instrument by lifting against the underside of the Arm, near the instrument. Simultaneously, push up or pull down the opposite end of the Arm immediately in front of the Slide. 4. Tighten four (4) set screws. Cleaning the Mounting Assembly 1. The mounting assembly may be cleaned with most mild, non-abrasive solutions commonly used in the hospital environment (e.g. diluted bleach, ammonia, or alcohol solutions). 2. The surface finish will be permanently damaged by strong chemicals and solvents such as acetone and trichloroethylene. 3. Do not use steel wool or other abrasive material to clean the mounting assembly. 4. Damage caused by the use of unapproved substances or processes will not be covered by warranty. We recommended that you test any cleaning solution on a small area of the arm that is not visible to verify compatibility. 5. Do not submerge or allow liquids to enter the arm. Wipe any cleaning agents off of the arm immediately, using a waterdampened cloth. Dry the arm thoroughly after cleaning. CAUTION: GCX makes no claims regarding the efficacy of the listed chemicals or processes as a means for controlling infection. Consult your hospital s infection control officer or epidemiologist. To clean or sterilize mounted instruments or accessory equipment, refer to the specific instructions delivered with those products. DU-AG-0021-25 Rev B 7/17/06 GCX Corp Page 6 of 6