Eva400EE/Eva400EM. Functional inspection. Always read the manual. SystemRoMedic TM. Manual - English

Similar documents
Eva450EE. Functional inspection. Always read the manual. SystemRoMedic TM. Manual - English

adopts a holistic approach to patient transfers and is organized in four categories: transfer, positioning, support and lifting.

Visual inspection Inspect lift functions regularly. Check to ensure that material is free from damage.

RiseAtlas450M, with QuickTrolleySystem SystemRoMedic TM

Liko M220 / Liko M230

Instruction Guide. English. Uno 100/102 - EM, EE, ES 7EN

Viking M / Viking L / Viking XL

Viking L. Product Description. Instruction Guide

Uno 100/102. Product Description. Instruction Guide

FreeSpan UltraTwin. Product Description. Instruction Guide

Transfer Motor Likorall ES

Likorall 242/243/250. Product Description. Instruction Guide. Likorall 243 ES. Likorall 243, 250. Likorall 242 R2R

Overhead lift Roomer 5200

Multirall 200. Product Description. Instruction Guide

Multirall 200. Prod. No

Multirall 200. Product Description. Instruction Guide

Product Description. In this document, the person being lifted is referred to as the patient, and the person helping is referred to as the caregiver.

Golvo. Product Description. Instruction Guide

The complete mobile lift

SGA-440 by Prism Medical

Vanturn Service Manual

Prism A-205. Owner s Manual. Aluminium Mobile Hoist. Use and Care Trouble Shooting Warranty Information. Introduction Overview...

Molift Mover 300. EN - User manual. BM06101 Rev. F

Molift Mover 205. EN - User manual. BM05101 Rev. L

Molift Mover 180. EN - User manual. BM08101 Rev. D

Instruction manual. RP800 - HYDRAULIC actuator, load 150Kg. RP815 - LINAK actuator, load 150Kg

Molift Partner 255. EN - User manual. BM03101 Rev. L

Oxford. Manufacturer s Contact Details. Contents. Oxford Presence. English

Contents. Oxford Calibre. English

A205 Patient Lifter - Aluminium USER MANUAL

Instructions for use. digital. Bure Rise & Go Walker and Stand-aid with Power Rise Function. Bure Rise & Go

Pallas/150. Stand-aid lifter. User instruction. Important - information. This user instruction must be read before the Pallas 150 is used.

All-in-One Hoist User Manual , , ,

Bure Rise & Go Walker and Stand-aid with Power Rise Function

Likorall. LOAD TESTING 12 Mechanical lowering load test (242) Maximum load rail system... DOCUMENTATION 14 Instructions / Instruction guide...

The Future of Homecare Lifting is Here!

320 kg yoke diagnostic

User guide Operator chair Carl Carl Foot and Carl Heel

180 kg yoke or pivot diagnostic

PRISM MEDICAL UK SA160C STAND AID

Molift Quick Raiser 205

aks-goliath Operating manual (translation of the original operating manual)

R710. R710 Product Manual

Pneumatic Actuator. Operation & Service Manual. Models: Original Instructions UNIBLOC PUMP MANUAL NO.: REVISION: 08/2016

1.3. Unpacking the chair... 4

FieldView External Charger. User Guide

SONATA 150 ELS MOBILE PATIENT LIFTING HOIST USER MANUAL IMPORTANT:

Sequoia 2 Post System

User Instruction Manual Classic Lifts Mini Midi Major Maxi. To avoid injury, read user manual prior to use.

Instructions for use Shower stretcher Marina

Control Box CBJ1 / CBJ2. Data sheet LINAK.COM/MEDLINE-CARELINE

User Manual Operator chair Carl Mk2

WHEELED WALKER OWNER S HANDBOOK

Aluminium Mobile Hoists

atient lifters Assembly, Maintenance & Specifications Manual SUNRISE HML400 Hoyer Manual Patient Lift HPL400 Hoyer Power Patient Lift Sunrise Medical

FGSH-450 by Prism Medical

SERVICE MANUAL US. Permobil M300/M400. Power Wheelchair

Smart 110 with built-in flashlight for 6 240Ah lead-acid batteries

Free Standing Track. Owner s Manual. Use and Care Trouble Shooting

SurePower TM II Battery Pack Guide

WheelieSafe. WheelieSafe. User Manual. Motorized Trolley. Distributor:

IN & TM Series User Manual

Battery Charger. Series EASY Charger. User s manual

A200S Patient Stander - Aluminium USER MANUAL

OPERATOR. Molift Mover 180. Etac AS Etac Supply Gjøvik Hadelandveien 2 N Gjøvik

Instruction Manual. Made in Israel Distributed by:

17. Remove the screws from the motor plate.

QA4 Surgery Trolley System Manual Function Operating Instructions

BATTERY OPERATED PATIENT LIFT MODEL:650HD OWNER S MANUAL

COBRA Indoor base with gas pressure spring and 45 tilt function user manual

Multirall 200. Service Manual. Prod. No English 3EN Copyright Liko AB

Yesterday s challenge Today s solution. User Manual. innova.uk.com

User manual Patient chair Malin

Re.Formance Line INSTRUCTION MANUAL 1703

PCBL 1610/ 1810 DE LUXE POWER WHEELCHAIR USER'S MANUAL Edition

CRD610 Automatic Fitting Inserter

Marlin Bath Lift BLM-8200 WARNING! Read ALL instructions before using this product!

POWER TILT ACCESSORY FUZE T50 STELLAR GL STELLAR LEAP OWNER S OPERATION AND MAINTENANCE MANUAL

User Manuel. Titan Hummer XL

3-Wheel Aluminium Rollator. User Manual.

IN120L / IN120LB / TM120L/TM120LB IN2400L

BRIANA: Bedside Lift MODEL:BSL220. ALTON: Bathtub Lift MODEL:BTL330. The Future of HomeCare Lifting is Here!

User Manual SONESTA S2 & S3

K-SERIES PUBLIC USE LIFT OPERATING INSTRUCTIONS

ERGO KIT TEK01 SERIES

SERVICE MANUAL. Koala

Instructions for Use. Amfibi Hygiene chair. Amfibi Double HighBack

BATTERY OPERATED PATIENT LIFT MODEL: 650HD OWNER'S MANUAL

Turner PRO. User manual. BM61099 Rev B

OPERATOR. Molift Mover 180. Etac AS Etac Supply Gjøvik Hadelandveien 2 N Gjøvik

Dealer Stamp. Rollator (R6 and R8) Assembly & Operating Instructions

CORDLESS TACKER MODEL NO: CCT48 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0414

Instructions for use. Bure. Walker. Bure Standard EL Bure S EL Form #2-246 Rev. 8/15/18

USER MANUAL. Item: #13246 Stand-Aid Lift. Drive Medical Design and Manufacturing Push Handle. Base Width Adjustment Handle.

Armon Edero. User manual

Roze Stand Up Patient Lift

Instruction manual. Liftkar HD Uni Liftkar HD Fold Liftkar HD Dolly Liftkar HD Fold Dolly. Issued: 10/2010 subject to updates.

USER MANUAL. Tides La Mer Treatment Table Rev A 3/28/19. *all tables shown with optional accessories and/or finishes

ACROBAT SWING STAND MODEL

M Series Mobile Lift. User Manual. 45 Progress Parkway, Maryland Heights, MO 63043, USA. M-Series User Manual Rev 10JAN2012 Page

Transcription:

DRAWN APPROVED BY STATUS: COMMENTS: NAME DATE TITLE SIZE MATERIAL: SCALE:1:10 DW Eva400EE/Eva400EM SystemRoMedic TM Manual - English 2 3 1 5 4 6 7 REVISION HISTO A REV. DESCRIPTION 3 4 5 6 7 2 B C D 13 11 12 1 9 Eva450EML 14 1. Boom 2. Mast 3. Handlebar 4. Battery pack 5. Emergency stop 6. Control box Eva450EEL Eva600EEL 7. Motor for base-width adjustment (model EE) 8. Rear castors with brakes 9. SlingBar with safety latch 10. Front castors 11. Emergency lowering 12. Motor/actuator for boom 13. Mast height adjustment 14. Base-width adjustment pedal (model EM) hc-jope Mobile lift Eva400EE/EM has been developed to meet most lifting needs in combination with the right accessories. It is a lift that can lift patients in a seated or supine position. Eva400EE/EM is made largely of aluminum, which makes it relatively light, considering the weight it can lift. Eva400 is available in two models: EE and EM. Model EE has electrical base-width adjustment and model EM has manual base-width adjustment. Handicare s SystemRoMedic product series includes a range of lifts, slings and other accessories. SystemRoMedic adopts a holistic approach to patient transfers and is organized in four categories: transfer, positioning, support and lifting. 8 Visual inspection Functional inspection E F Inspect lift functions regularly. Check to ensure that material is free from damage. 10 1 2 3 4 SWL: 180 kg / 400Ibs Released 2011-05-20 Unless otherwise stated, general tolerances according to ISO 2768-m EVA E This drawing and any information or descriptive matter set out hereon are th and must not be disclosed, loaned, copied or used for manufacturing, tend A3 9 Before use: Ensure that the product is correctly assembled. Check slingbar connection and safety latch function. Check lift and base-width movement. Check to ensure that the actuator is correctly installed. Always read the manual Always read the manuals for all assistive devices used during a transfer. Keep the manual where it is accessible to users of the product. The lift may only be used by persons who have received instruction in the operation of the lift. Manual nr: 790 En Ver. 3 130708

Table of contents Assembly... 3 - Final inspection... 4 Using the product... 5 - Important information... 5 - Safe working load... 5 - Charging batteries... 6 - Handset... 6 - Base-width adjustmentt... 6 - Emergency stop... 7 - Emergency lowering... 7 - Brakes... 7 - Trouble shooting... 8 Accessories... 9 Maintenance...10 Technical information...11 - Dimensions Eva400EE/EM...12-13 2 MANUAL SystemRoMedic TM

Assembly Check to ensure that all components are included: Mast with boom, lift motor, carry bar, control box and battery pack. Base with motor and locking handle. Handset and cord. Instructions, charger with cable and adapter for wall socket. Place the mast in the base. There are three alternatives for adjusting the height of the mast. Secure the mast with the locking handle. Mount handlebar with two wrenches. Handset 1 2 cover for the cables Connect the cables to the kontrollbox. Cable to actuator (motor on mast) to outlet 1, and cable for base-width adjustment motor to outlet 2 (model EE). Mount the cover for the cables using the two screws. Release the emergency-stop mechanism and perform a final inspection (see final inspection). SystemRoMedic TM MANUAL 3

Final inspection Check to ensure that no parts have been left in the packaging. Inspect the lift for signs of wear and damage. Check all four castor wheels and castor wheel locks. Check all connections and fixtures including screws and bolts. Check the emergency stop function by depressing the emergency stop, and then pressing either the up or down button. If nothing happens when the up or down buttons are pressed, the emergency stop is functioning properly. Grasp the handset, press the up button and run the lift arm all the way up. Then, press the down button and run the lift arm all the way down. Test base-width adjustment function. Model EE: Press the button for base-width adjustment to widen the base fully, and then press the other button to narrow the base again. Model EM: Test base-width adjustment function on model EM by pushing down on the respective pedals for widening and narrowing the base. Test lift function by lifting a person (not a patient) using an approved sling. At the same time, check the emergency lowering function with someone on the lift. See section on Emergency lowering. If the lift is functioning correctly, connect the charger and check to ensure that the charging lamp on the control box lights up. NOTE! Before the lift is used for the first time, it must be charged for at least 4 hours. See section on charging batteries. Keep the manual where it is accessible to users of the product. 4 MANUAL SystemRoMedic TM

Using the product Important Information The lift must be assembled according to the assembly instructions provided with the lift. The lift may only be used indoors and on a level floor. When lifting from the floor the rear wheels must always be locked to prevent the lift from rolling and colliding with the patient s head. Otherwise, the wheels should not be locked, so that the lift can align itself with the patient s centre of gravity. Lifting accessories must be properly trial fitted and tested in relation to the patient s needs and functional ability. Do not leave the patient unattended during a transfer situation. Under no circumstances may max. load be exceeded. See section on Safe working load. Never move the lift by pulling on the actuator! Do not push The lift must not come in direct contact with water. The lift must not be charged in a wet room. To ensure optimal function, the lift must be inspected regularly. See section on Maintenance. Warranty applies only if repairs or alterations are done by an authorized technician. Safe working load Different products on the same lift system (lift unit, slingbar, sling, scales and other lifting accessories) may have different allowable safe working loads. The lowest allowable safe working load always determines the safe working load of the assembled system. Always check the safe working loads for the lift and accessories before use. Contact your dealer if you have any questions. SystemRoMedic TM MANUAL 5

DRAWN APPROVED BY STATUS: COMMENTS: NAME DATE TITLE SIZE MATERIAL: SCALE:1:10 DWG. NO. WEIGHT: DRAWN APPROVED BY STATUS: COMMENTS: SHEET 1 OF 1 NAME REV. DATE TITLE SIZE DWG. NO. REV. Charging batteries A tone when using the lift indicating that the batteries need recharging. Lock the castors when charging the battery. Make sure the emergency stop button is not pressed in. Charging procedure: Charger LED indication of charging LED indication of handset activation Button for electrical emergency lowering 1. Connect the charger to the charger cable leading from the underside of the control box. 2. Connect the charger to a power outlet (100-240 V AC). 3. When the charger is connected, the control box lamp indicates a yellow light. NOTE! Before the lift is used for the first time, it must be charged for at least 4 hours. Charge batteries regularly for maximum longevity. We recommend daily charging when the lift is in daily use. The emergency stop button must be pulled out during charging. Handset Raising/lowering the lift arm 3 5 4 6 7 8 REVISION HISTORY Symbol indicate direction of travel. REV. DESCRIPTION DATE APPROVED Motion stops as soon as the button is released. A Widening/narrowing the base (model EE) Markings on the buttons indicate function. 2 3 1 5 4 6 7 8 Motion stops as soon as the buttons are released. B REVISION HISTORY REV. DESCRIPTION DATE APPROVED A Eva450EEL Eva600EEL Base-width adjustment C Modell EE Eva450EML Manual base-width adjustment (model EE) Markings on the buttons of the handset indicate function. Motion stops as soon as the buttons are released. Eva450EEL Eva600EEL Manual base-width adjustment (model EM) Push down on the respective pedals at the back of the lift to widen and narrow the base. D B C Modell EM D hc-jope 2011-05-20 Released Unless otherwise stated, general tolerances according to ISO 2768-m EVA EEL 450 base A3 90001288 02 g 3 4 This drawing and any information or descriptive matter set out hereon are the confidential and copyright property of Handicare and must not be disclosed, loaned, copied or used for manufacturing, tendering or any other purpose without their written permission. hc-jope 2011-05-20 6 MANUAL SystemRoMedic TM Released Unless otherwise stated, general EVA EEL 450 base

Emergency stop To activate emergency stop: Depress the red emergency stop button on the control box. Resetting: Turn the button in the direction of the arrows until the button pops out. To prevent battery discharge, we recommend that the emergency-stop button is pressed in when the lift is not in use. Emergency lowering Manual emergency lowering: For manual emergency lowering, turn the round plastic knob on the actuator clockwise. Electrical emergency lowering: For electrical emergency lowering, use the down button on the control box. Brakes Locking the wheels Lock the rear wheels by pressing down on the brake pedals on both rear wheels with your foot. Wheels should not be locked during lifting, so that the lift can align itself with the patient s centre of gravity. The only time the wheels should be locked is during lifting from the floor; otherwise, there is a risk of the lift rolling and colliding with the patient s head. Locked wheels during lifting increase the risk of the lift tipping. Unlocking the wheels To release the wheel brakes, lift the brake pedals upwards with your foot. SystemRoMedic TM MANUAL 7

Trouble shooting If the lift or base-width adjustment cannot be activated, check the following: - That the emergency stop button is not pressed in. - That all cables are properly and securely connected. Pull out the contact and plug it in again firmly. - That battery charging is not in progress. - That the battery is charged. If the lift is not working properly, contact your dealer. If the lift makes unusual noises: - Try to determine the source of the sound. Take the lift out of operation and contact your dealer. 8 MANUAL SystemRoMedic TM

Accessories SystemRoMedic Slings SystemRoMedic offers a wide variety of functional and comfortable high quality lifting slings adapted to meet the different requirements of all kinds of lifting situations and users. The lifting slings are available in four different materials and in sizes ranging from XXS to XXL. All models are safe and very easy to use. Sling bars SlingBar is SystemRoMedic s aluminium sling bar. It s available in three different widths and is therefore suitable in most lifting situations and for users of all sizes. SlingBar S article no.: 70200001 SlingBar M article no.: 70200002 SlingBar L article no.: 70200003 SlingBarSpreader M article no.: 70200042 SwiftHook for sling bar article no.: 70200008 StretcherBar, article no.: 70200006, and StretcherSling, article no.: 46502007, for lifting in a supine position. Scale SystemRoMedic s scales Charder MHS2500 are used together with stationary or mobile lifts for weighing of users. Article no.: 70100002 Article no.: 70100003 AmbulationArm AmbulationArm mounted on the mast and provides support during gait training. Article no.: 80100010 Assistive devices for positioning SystemRoMedic includes a wide range of functional, comfortable, high-quality assistive devices for positioning that can be adapted for different types of lifting and for patients with different needs. Ready for life Sling bar The Ready for life four-point slingbar, Sling bar RFL X4, is designed to provide more space in the sling, for example, for obese and/or pain-sensitive users. Article no.: 70200017 SystemRoMedic TM MANUAL 9

Maintenance The lift must undergo thorough inspection at least once per year. Inspection must be performed by authorized personnel and in accordance with Handicare s service manual. Repairs and maintenance may only be done by authorized personnel using original spare parts. Spent batteries are to be left at the nearest recycling station. Spent batteries can also be returned to Handicare or a Handicare dealer for recycling. Cleaning/disinfection Clean the lift with warm water or rubbing alcohol and ensure that the castor wheels are free of dirt and hair. Do not use cleaning agents containing phenol or chlorine, as this may damage the material. Storage If the lift is not to be used for some time or e.g., during transport, we recommend that the emergency stop button be pressed in. Store the lift at a temperature above freezing point and not exceeding normal relative humidity (about 60%). Service agreements Handicare offers the possibility of service agreements for maintenance and regular testing of your mobile lift. Contact your local Handicare representative. 10 MANUAL SystemRoMedic TM

Technical information Lifting speed: Batteries: Charger: Motor (mast): Motor (base): Sound level: Material: Emergency lowering: Castors: Weight: IP class: Expected lifetime: Operating forces buttons on handset: 37 mm/s without load. Two 12V, 2,9 Ah valve-regulated, sealed, lead accumulator (gel-type batteries) Max. 400mA DC 24V, 4.5 A. IP X4. Operationtime: 10% at maximum continous running of 2 minutes, maximum 5 switching cycles per minute. Push: 6000N. 24V, 1.5 A, IP X4. Operationtime: 10% at maximum continous operation of 2 minutes, maximum 5 cycles per minute. Push: 1500N. With load: upwards: 43 db(a) downwards: 44 db(a). Aluminum Mechanical and electrical Front 4, 100 mm, back 4, 100 mm 75 lbs, 34 kg IP X4 10 years 4 N The lift complies with the requirements of Council Directive 93/42/EEC of 14. June 1993 concerning medical devices. The device is intended for indoor use. Type B, according to the degree of protection against electric shock. SystemRoMedic TM MANUAL 11

Dimensions Eva400EE/EM A B A1 58-186 22.85-73.28 A2 63-191 24.82-75.25 A3 68-196 26.79-77.22 B1 50-169 19.70-66.59 B2 54-174 21.28-68.56 G H B A B3 59-179 23.25-70.53 C1 130 51,22 C2 121 47,67 D 88 34,67 E 11,5 4,53 F 6 2,36 G1 133-192 52.4-75.65 G2 138-197 54.37-77.62 F C1 C2 D E G3 143-202 56.34-79.59 H 55 21.67 Column A measurement is in cm and weight is in kg. Column B measurement is in inches and weight is in lbs. 12 MANUAL SystemRoMedic TM

Dimensions Eva400EE/EM P I J A B I 44 17.34 J 45 17.73 K 58,5-88 23.05-34.67 L 68.5-98 26.99-38.61 M 134 54 N 34 74.9 O 14,5 31.9 Q 27 10.64 S 41 16,1 T 22 8,7 U 45 17,7 Q R K L Column A measurement is in cm and weight is in kg. Column B measurement is in inches and weight is in lbs. M is turning diameter N is total weight of lift O is the weight of the heaviest component P is movement in forward direction R is referencemeasure 70 cm with max legspreading S is minimum distance from wall to slingbar at maximum height (legs spread). T is minimum distance from wall to slingbar at maximum reach (legs spread). U is minimum distance from wall to slingbar at minimum height (legs spread). SystemRoMedic TM MANUAL 13

SystemRoMedic TM For 25 years we have applied ourselves wholeheartedly to developing smart and easy-to-use assistive devices for easy transfers and to making life and work easier for both patients and personnel in the care sector. Experience, innovation and training are the basis for SystemRoMedic, a total solution for every imaginable transfer situation. Transfer: products for moving patients between locations. Positioning: products for repositioning in the same location. Support: products that provide mobility support. Lifting: products adapted for lifting. The philosophy behind SystemRoMedic is to prevent occupational injuries while improving the patient s sense of independence and dignity. Through a combination of training and a complete range of transfer-assistive devices, SystemRoMedic offers the means to improving both the work environment and the quality of care while enabling significant cost savings. Our mission, to help people, has always been, and will continue to be, the driving force of innovation. We love easy transfers. Contact your local distributor if you have any questions about the product and its use. See www.handicare.com for a complete list of distributors. Always make sure that you have the right version of the manual. The most recent editions of manuals are available for downloading from our website, www.handicare.com Handicare AB Veddestav. 15, Box 640 SE-175 27 Järfälla SWEDEN Tel: +46 (0)8-557 62 200 Fax:+46 (0)8-557 62 299 E-mail: info@handicare.se Internet: www.handicare.com