VORTEX IN-LINE FLOW METERS

Similar documents
Vortex In Line Flow Meter

Vortex In Line Flow Meter

Armstrong In-Line and Insertion Vortex Flow Meters

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Low Profile Insertion Vortex

Hot Tap Insertion Vortex

F-2500 SERIES VORTEX METER

F-2600 SERIES INLINE VORTEX FLOW METER

VIM20 Vortex Insertion Flowmeter

F-2700 SERIES INSERTION VORTEX FLOW METER

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

Model FVP General Specification. Flanged Vortex Plate. Product Features

Multivariable Vortex Flow Meter

F-2600 SERIES INLINE VORTEX FLOW METER

Vortex Plate. Model VP General Specification. Product Features

F-2700 SERIES INSERTION VORTEX FLOW METER

Multivariable Vortex Flow Meter

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Transmitting Transducer. Gas/Air Velocity Range:

The readings you need, right where you need them. AX Series Vortex Meters

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

F-1500 SERIES INSERTION TURBINE FLOW METER

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Vortex Eggs Delta Flowmeter

The readings you need, right where you need them. AX Series Vortex Meters

RCM - Direct Reading Flowmeters

SIGNET 7002 Vortex Flow Sensor ENGLISH

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

KDM ARMORED FLOW METER & SWITCH

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Product Data Sheet. VN2000 Flow Meters. Hot Tap Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION OPERATION SIZING SOFTWARE

Vortex Flow Meter Model DVH

DW PADDLE-BELLOWS FLOWMETER & SWITCH

Model 5000 Vortex Meter

THE ROSEMOUNT 8800C DELIVERS RELIABILITY Rosemount Reliability -The 8800C Vortex eliates impulse lines, ports, and gaskets to improve reliabil

DW PADDLE-BELLOWS FLOWMETER & SWITCH

Product Data Sheet. VN2000 Flow Meters. Compact Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION

Rosemount 8800D Series Vortex Flowmeter

Model 1000 Vortex Meter

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

Rosemount 8800D Series Vortex Flowmeter

DW PADDLE-BELLOWS FLOWMETER & SWITCH

Weather-Proof Thermal Mass Flow Meter for Pipe - Duct

Appendix. Clearance. Skewed profiles. Application Schematics

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Innova-Mass Model 240 & 241. Multivariable Mass Vortex Flow Meter. For information online...

Product Data Sheet. VN2000 Flow Meters. Hot Tap Insertion Meter DESCRIPTION BENEFITS APPLICATIONS INSTALLATION OPERATION SIZING SOFTWARE

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

RCM. Direct Reading Flowmeter. for Liquids or Gases

Rosemount 8800D Series Vortex Flowmeter

Universal Instruction Manual. I/A Series Vortex Flowmeters Models 83F, 83W, and 83S

InnovaMass 240 & 241. Multivariable Mass Vortex Flow Meter. FEATURES DESCRIPTION

Hydro-Flow Model 3100

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

STEEMCO Flowmeter for Steam

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Product Data Sheet. VN2000 Flow Meters. Wafer Plate Inline Meter DESCRIPTION BENEFITS OPERATION APPLICATIONS SIZING SOFTWARE

VersaFlow Vortex 100 Vortex Flow Meter Specifications

VLM20 In-line Vortex Flowmeter

VIM20 Vortex Insertion Flowmeter

ISTEC MAGNETIC METERS

Operating Instruction for Plastic Vortex Flow Transmitter. Model: UV

ORIMAS Mass Flowmeter

Vortex Flowmeter Model DVE

mass flowmeter for compressed air

Series Level-Trol Electronic Liquid Level Transmitters

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

DPT TARGET TYPE FLOWMETERS

Electromagnetic Flowmeters. Product Overview.

Signet 7000/7001 Vortex Flow Sensors * *

PMG MAGNETIC FLOWMETER

OPTISWIRL 4070 Technical Datasheet

SITRANS FX300 4/289. System Overview. Overview

HYGROMETERS HUMIDITY MEASUREMENT YOU CAN COUNT ON.

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

STEEMCO-MAS Flowmeter for Steam

Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

CANADA SENSORS TECHNOLOGY INC.

OPTISWIRL 4070 Technical Datasheet

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

VFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Fundamental Training. Flow Con t

BARTON 7400 Precision Gas Turbine Flow Meters

ProMinent EXtronic Solenoid Diaphragm Metering Pumps

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

DYNAMETERS SERIES DMTF ULTRASONIC FLOW METER

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

VIM20 Vortex Insertion Flowmeter

Hydro-Flow Model 2200 Installation and Operation Guide B

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 124

Accutrol, LLC Product Sheet. VTS Series. US Patents 6,991,177 & 7,543,759. Digital Airflow Measurement Station

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Transcription:

VORTEX IN-LINE FLOW METERS Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, degrees out of phase to each other, resulting in an oscillating pressure gradient. As flow increases the frequency of vortices increases in proportion to the increased flow thereby creating a linear relationship. Aalborg's unique dual signal processing technology independently measures each vortex on either side of the bluff body and filters out non-flow noise. This results in less noise and higher accuracy throughout the flow range. Dual signal processing technology independently measures each vortex providing increased accuracy and turndown. TABLE 29 - BENEFITS RELIABLE WIDE RANGEABILITY HIGH ACCURACY No moving parts to wear or fail. Electronics can be remote mounted up to 30.5 m (0 ft). No fluid to sensor contact. No holes to clog. High flow turndown ratio up to 0:. Dual signal processing technology improves accuracy at low flows. + 0.5% of rate. Increased noise cancellation as a result of dual signal processing technology. TABLE 30 - FUNCTIONAL SPECIFICATIONS Vortex In-line Flow Meter Shown with Wafer Mounting FLUID TYPES MAXIMUM PRESSURE FLUID TEMPERATURE LOW FLOW CUT-OFF HIGH FLOW CUT-OFF VOLTAGE FREQUENCY OUTPUTS Steam, Gas, Liquid. 3 bar (500 psig) with wafer mount See Table 0 for flange mount. -73 F to 232 F C std./to 36 F C opt. (-0 F to 50 F F std./to F F opt). Adjustable: Set @ min. per Tables 3 to 3. Adjustable: Set @ max. per Tables 3 to 3. 5 /230 VAC selectable or 2 VDC. 50 /60 Hz. Analog: -20 ma DC into ohm or less. LINEAR RANGE Reynolds number of >,000. Figure BULLETIN EM200 www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337

VORTEX IN-LINE FLOW METERS TABLE 3 - PERFORMANCE SPECIFICATIONS ACCURACY REPEATABILITY FLOW TURNDOWN RATIO RESPONSE TIME + 0.5% of rate. + 0.25% of rate. See Tables 3 to 3. 00 ms. DAMPING Adjustable: to sec. 000µ VELOCITY RANGE Liq.:.32 or to 30 ft/sec ñd 2 Steam & Gas: (/ñ)/3 to 250 ft/sec ñ= density (lb/ft3) d= pipe diameter (in) µ= viscosity (cp) AGENCY APPROVALS* FM and CSA Class Div 2 Groups B,C,D. * Designed to meet. Contact Aalborg for status of the agency approval. **The selection of materials of construction, is the responsibility of the customer. The company accepts no liability. TABLE 32 - PHYSICAL SPECIFICATION **MATERIALS OF CONSTRUCTION SHEDDER BAR ELECTRODES METERING TUBE FLANGES ELECTRONICS HOUSING 30 SS or 36 SS. 30 SS or 36 SS encapsulated ceramic. 30 SS or 36 SS. 30L SS or 36L SS. Epoxy coated aluminum. CONNECTIONS AND MOUNTINGS MOUNTING POSITION TYPICAL STRAIGHT PIPE REQUIREMENTS TEMPERATURE TAP (BY CUSTOMER) PRESSURE TAP (BY CUSTOMER) PROCESS CONNECTIONS ELECTRICAL CONNECT Vertical, horizontal, angle. Upstream: 20 x D. Downstream: 5 x D. Downstream: 3.5 x D. Upstream: 3.5 x D. ANSI Class 50 RF, RF, RF, Wafer. 3/" FNPT. TABLE 33 - ELECTRONIC SPECIFICATIONS AMBIENT TEMPERATURE -2 F to 65 F C (-5 F to 9 F F). 9 Vortex In-line Flow Meter Shown with Flange Mounting TRANSMITTER Microprocessor-based. DISPLAY Two lines, simultaneous rate and total, 6 alphanumeric characters each. FUNCTIONS OUTPUT SIGNAL ENCLOSURE PROTECTION ENCLOSURE APPROVALS POWER SUPPLY Zero, span, hi cutoff, low cutoff, response time, sample time, engineering units, totalizer, data logger, RS-232 interface. -20mA output into Ohm or less, 5V TTL Pulse Output. Use or 20 gauge twisted pair shielded cable. NEMA X. UL, CSA, FM Class I Groups B, C, D Class II Groups E, F, G KEMA/CENELEC EEx d IIB 5-30 VDC or 5 / 230 VAC (optional). www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 BULLETIN EM200

VORTEX IN-LINE FLOW METERS Flow Ranges Minimum and maximum flow rates to achieve accuracy in Gal/min, L/min. Pipe ID based on schedule 0 steel. TABLE 3 - WATER FLOW RATES AT 60 F F SIZE (INCH) 3/" ".5" 2" 3" " min max min max min max min max min max min max Gal/min 2.6 0. 3. 67.2 7.3 6.9 2. 276.0 27.2 67.6 7.3 75.3 L/MIN 9.9 52.9 2. 25.3 27.5 62. 6.0.9 2.9 2337.9 79. 070. Minimum and maximum flow rates to achieve accuracy lb/hr. Pipe ID based on schedule 0 steel. TABLE 35 - SATURATED STEAM FLOW RATES AT SELECTED PROCESS PRESSURES (English) SIZE (INCH) 3/" ".5" 2" 3" " PRESSURE (psig) min max min max min max min max min max min max 25 50 75.7.7 6.0 9.6 3.6 29.9 20.9 27.5.5 9.5 26.5 32.6 203.5 36.0 9.6 677.7 35.7.0 65. 0.0 66..9 69.3 225. 59.7 0.3 9.0 33.9. 73.5 2760. 375.3 33.5 79.6 23.9 299.6 250.7 390.2 675.9 09.3 232.5 32.6 2.7 52.7 355.6 6792. 752. 60.7 0 25 50 200 22.9 25.9 2. 3. 35.3 23.5 92.7 639.2 3. 3. 7.9 56. 5. 30 99 555 93. 5.9 7.6 39. 233. 37. 00.0 560. 56. 77.2 96. 233.2 7.7 579.5 6695.5 636. 39.9 396.5 0. 52. 609.7 2797.7 9.6 932.6 609. 690.2 766.7 90.5 7.6 2220.9 2603. 336.2 250 350 00 39. 3.7.2 52.5 72.7 3.6 57 7 65.0 72. 0.2 7.3 90 250 2573 257 59.6 7.6 96. 2.3 6323.9 79.3 663. 9.2 267.0 29.9 329. 35.7 52.9 2533. 9.0 67.0 597.5 66. 737.0 02.6 23679.9 203.5 320.2 366.6 0.3 6.5 23.2 397.3 226.9 2.0 567.6 676.3 50 500 550 56.6 60.7 6.7 6.5 36 60 605 752 9.2.0 7.5.0 3202 3552 3905 262 23.3 27. 26.0 279. 36.0 220.0 356.0 6.2 37..7. 6.3 6.5 203.2 225.2 2573.6 66. 92.0 9.5 7. 32.3 532. 5035.9 59. 507.9 65.7 72.0 2.2 795.9 7979.5 7722.2 95729.0 BULLETIN EM200 www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 50

VORTEX IN-LINE FLOW METERS Minimum and maximum flow rates to achieve accuracy in (kg/hr) Pipe ID based on schedule 0 steel. TABLE 36 - SATURATED STEAM FLOW RATES AT SELECTED PROCESS PRESSURES (Metric) Size (mm) 20 25 0 50 0 0 Pressure (bara) min max min max min max min max min max min max 2 6 2.5 3.9 5.9 7.7 22. 3.5.0 23. 7.7.9 5.3 5.9 5 206.2 5.7 2.2 3.2.6 353.2 676.6 99.3 7.0 26.2 0. 52. 307.7 5.6 27.6 652.2 3. 5.7 90.5 6.7 69.9 39. 252.2 370.3 66.3 2.2 57.6 203.3 20.7 229. 03.6 652. 22.6 3. 5.5 7.6 200 276 353 26 2.2 26.3 30.9 35.2 9 673 62 37 3.2 53.5 62.9 7.7 609.6 2222.3 23.7 39.7 7.9 9.2.9 9.6 262.6 3703.9 72.5 579.5 6.3 200.0 235.2 26. 60.7 30. 592. 29. 20.9 3.3 09.6 66.9 76.3 6.5 50. 2253.5 26 2 30 32 9.7 20.7 2.6 22.6 505 53 569 607 39.3.3 3.3 5.2 229 29 369 6 0... 92.0 069.0 30.6 693.7 500.5 33.5.2 6. 53.3 67.6 7.9 722.9 37.5 299.3 3. 329.2 33.7 5205.0 6369. 7539. 75.9 52.2 57.5 573.3 59.7 263.9 252.0 30550.5 32599.0 3 36 3 0 23.5 2.5 25. 26.3 637 675 73 75 7..9 50. 52.6 530 622 7 6 95. 99.6 3.3 7.0 5325.0 563.3 5963.7 626.0 59.7 66.0 72.2 7. 7.9 905.5 9939.5 76.7 35.0 372.2 36. 399.9 99.5 2. 2225. 2390.0 623.6 6.3 672.6 696.6 365.9 3673.0 36.3 09.5 Minimum and maximum flow rates to achieve accuracy in CFPM (.7 psia 70 F F) CFM at actual process temperature = min. or max values below *520/ (Actual Temp. ( F F) + 60) Pipe ID based on schedule 0 steel. Flow Temp. 60 F F. TABLE 37 - AIR FLOW RATES AT SELECTED PROCESS PRESSURES (English) Size (inch) 3/" ".5" 2" 3" " Density (lb/ft3) Pressure (psig) min max min max min max min max min max min max 5 0.076 0.3 0.2 0. 0.232 0.2 0.336 0.3 0.0 0.93 0.55 0.596 0.69 0.700 0.752 0.0 0.56.6.636 0 5 20 30 0 50 60 70 0 90 0 20 30 50 200 2.2 2.7 3. 3.9.7 5.3 6.0 6.6 7. 7.7.2.7 9.2 9.7.2.7. 3.3 7. 22.2 29. 37. 52.6 67.7 2.9 9. 3.2 2. 3.6 5.7 73.9 9. 20.2 29. 23.6 29.7 325.6 77.2 3.7.5 5.2 6.6 7..9 9.9.9.9 2. 3.7.6 5. 6.2 7.0 7..5 22. 2.5 5.2 72.7 9.9 2 6 20 23 275 32 39 36 23 60 97 53 570 607 792 6 9..0 2. 6. 9. 2. 2. 26. 29.2 3. 33.6 35.7 37.7 39..7 3.6 5.5 5.2 70.0 3. 26.3 30. 33. 55. 63. 0. 933. 5. 3. 30. 33. 55. 63.. 933. 205. 263. 3933. 5.2.5 2.5 26.9 3.9 36.5 0..9. 52.6 56.2 59. 63.2 66.5 69. 73.0 76. 90. 7. 307.5 2. 56.7 725.9 935..2 353. 562.6 77. 9.0 290.2 2399.3 260.5 27.7 3026.9 3236. 35.3 9.2 653.0 3.0.3. 60.3 7..7 9.3 0.5 9.3 7.7 25. 33..3.9 56.2 63.3 70.2 203. 262. 6. 922. 56. 62.2 2092.2 2560.3 302. 396. 396.5 32.5 900.6 536.7 536.7 630. 6772. 720.9 7709.0 09.3 729.9 59.2 7.9 3.7.9 2.2 2.2 59.0 75.0 90.2 20.9 29.0 232.9 26. 259.2 27.9 2.2 296. 353.6 56.3 97.9 605.3 202. 227.7 362.6 57.5 5272. 607.3 6902.2 777. 532.0 936.9 6. 976.7 79.6 2606.5 32. 795.9 256. www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 BULLETIN EM200

VORTEX IN-LINE FLOW METERS Minimum and maximum flow rates to achieve accuracy in M 3 /min ( F C,.03 bar). M 3 /min at actual process temperature = minimum or maximum values below x 273 (actual temp ( F C) + 273). Pipe ID based on schedule 0 steel. Flow Temp 0 F C. TABLE 3 - AIR FLOW RATES AT SELECTED PROCESS PRESSURES (Metric) Size (mm) 20 25 0 50 0 0 Density (kg/m3) Pressure (barg) min max min max min max min max min max min max.293.93 2.56 3. 5.2 6.39 7.67.95.22.5 2.77.05 0 0.5 2 3 5 6 7 9 0.05 0.07 0.09 0. 0. 0.6 0. 0.20 0.2 0.23 0.25 0.27 0.63 0.9.26.9 2.52 3.5 3.7. 5.05 5.6 6.3 6.9 0.09 0.2 0. 0. 0.22 0.26 0.29 0.32 0.35 0.3 0. 0..53 2.30 3.07.60 6. 7.6 9.2.75 2.29 3.2 5.36 6.9 0.22 0.29 0.35 0.6 0.55 0.6 0.73 0.0 0. 0.95.02.09 5.2 7.7.35 5.9 20.6 25.7 30.92 36.06.20 6.3 5. 56.62 0.37 0. 0.5 0.76 0.92.07.2.3.6.5.70..69 2.97 7.26 25.2 3.39 2.96 5.53 60. 6.67 77.2 5.0 9.37 0.3.0.3.7 2.07 2.0 2.7 3.00 3.2 3.55 3..06 9. 29.0 3.69 57.90 77. 96.32 5.5 3.75 53.96 73.7 92.3 2.59.. 2.2 2.9 3.6.9.72 5.23 5.72 6.9 6.6 7.07 33.92 50.66 67.39 0.5 3.3 67.77 20.2 23.70 26.6 30.63 335.09 36.55 5.32 6.6 7. 9.5 2 3 0.2 0.30 0.3 0.33 7.57.20.3 9.7 0.6 0.9 0.5 0.5.3 9.97 2.50 23.0.5.2.2.3 6.76 66.9 72.05 77.9.92 2.02 2.3 2.23 2.9.5 20.0 2.65.30.5.77.99 230. 250.02 269.23 2. 7.9 7.90.30.69 02.0 35. 6.9 502.0 22.9 26. 7 20 0.37 0..36 3.25 0.6 0.67 27.65 32.26.5.67 92.6.0 2.5 2.7 5.35.06 5.63 6.2 36.0 03.7 9.. 602.79 703. ANSI Flange Pressure - Temperature Ratings. Maximum Pressure in psig. Ambient Temperature Range for Electronics TABLE 39 - FLOW METER PRESSURE RATING BULLETIN EM200 TEMP. F F MATERIAL -0 to 0 200 00 500 30L SS/36L SS 50# RF 230 95 75 60 5 30L SS/36L SS # RF 505 55 5 30 360 30L SS/36L SS # RF 200 5 9 25 765 720 30L SS/36L SS 900# RF 500 500 360 20 5 0 30L SS/36L SS 500# RF 500 500 500 500 500 500 www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 52

VORTEX IN-LINE FLOW METERS TABLE 0 Flange Mounting Meter Size Flange Rating Bolt diameter Bolts I.D. O.D. W H in. psi in. no. in. in. in. in. 3/ 50 900 500 50 900 500.5 50 900 500 2 50 900 500 3 50 900 500 50 900 500 /2 7/ 7/ /2 /2 3/ 3/7 -/ -/ 3/ 3/ -/ 3/ 7/ -/ -3/ 0.72 3.75.625.625 5.25 5.25 0.957.25.75.75 5.75 5.75.50 5.00 6.25 6.25 7.00.937 6.00 6.50 6.50.50 2.900 7.50.25.25 9.50.50 3.26 9.00.00.75.50 2.25 5. 6.25 6.25 7.25 7.25 6.3 6.63 6.63 7.5 7.5 6.63 7.3 7.25.25.25 6.75 7.25 7.50 9.75 9.75 7.25.00.25 9.75.00.25 9.00.25.25 2.00 9.75.25.25.375 9.95.27.27.76.76.35.9.9.35.35.75.25.25 2.25 2.25.60.9.9 2.60 3. 2.37 2.7 3.25 3.62 3.93 Wafer Mounting TABLE Meter Size Flange Rating Bolt diameter Bolts I.D. O.D. W H in. psi in. no. in. in. in. in. 53 3/ 50 50.5 50 2 50 3 50 50 /2 /2 /2 3/ 3/ 3/ 3/ 3/ 7/ 0.72 2.370 2 9.00 0.957 2.70 2 9.20.500 3.500 2 9.60.937.250 2.00 2.900 5.97 2.60 3.26 6.997 2.5.37 www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 BULLETIN EM200

VORTEX INSERTION FLOW METERS TABLE 2 - BENEFITS RELIABLE WIDE RANGEABILITY HIGH ACCURACY No moving parts to wear or fail. Electronics can be remote mounted up to 0 ft. (30.5 m) No fluid to sensor contact. No holes to clog. High flow turndown ratio up to 0:. Dual signal processing technology improves accuracy at low flows. + 0.5% of rate. Increased noise cancellation as a result of dual signal processing technology. Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, degrees out of phase to each other, resulting in an oscillating pressure gradient. As flow increases the frequency of vortices increases in proportion to the increased flow thereby creating a linear relationship. Aalborg's unique dual signal processing technology independently measures each vortex on either side of the bluff body and filters out non-flow noise. This results in less noise and higher accuracy throughout the flow range. Vortex Insertion Flow Meter Shown with Retractable Mounting Vortex Insertion Flow Meter Shown with Fixed Mounting TABLE 3 - FUNCTIONAL SPECIFICATIONS FLUID TYPES MAXIMUM PRESSURE FLUID TEMPERATURE LOW FLOW CUT-OFF HIGH FLOW CUT-OFF VOLTAGE FREQUENCY Steam, Gas, Liquid. 500 psig (3 bar) see Table 7 for flange ratings. -0 F to 50 F F std. to F F opt. (-73 F to 232 F C std., to 36 F C opt.) Adjustable: Set @ min. per Tables to 50. Adjustable: Set @ max. per Tables to 50. 5 30 VDC or 5/230 VAC (optional). 50/60 Hz. OUTPUTS Analog: -20 ma DC into ohm or less. LINEAR RANGE Reynolds number of >,000. Figure BULLETIN EM200 Dual signal processing technology independently measures each vortex providing increased accuracy and turndown. www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 5

VORTEX INSERTION FLOW METERS TABLE - PERFORMANCE SPECIFICATIONS ACCURACY REPEATABILITY FLOW TURNDOWN RATIO RESPONSE TIME DAMPING VELOCITY RANGE AGENCY APPROVALS* + 0.5% of rate. + 0.25% of rate. See Tables to 50. 00 ms. Adjustable: to sec. Liq.:.32 or 000µ to 30 ft/sec ñd 2 Steam & Gas: (/r) /3 to 250 ft/sec ρ= density (lb/ft3) d= pipe diameter (in) µ= viscosity (cp) FM and CSA Class Div 2 Groups B,C,D. *Designed to meet. Contact Aalborg for status of the agency approval. **The selection of materials of construction, is the responsibility of the customer. The company accepts no liability. TABLE 5 - PHYSICAL SPECIFICATIONS **MATERIALS OF CONSTRUCTION SHEDDER BAR ELECTRODES METERING TUBE FLANGES ELECTRONICS HOUSING 30 SS or 36 SS. 30 SS or 36 SS encapsulated ceramic. 30 SS or 36 SS. 30L SS or 36L SS. Epoxy coated aluminum. CONNECTIONS AND MOUNTINGS MOUNTING POSITION TYPICAL STRAIGHT PIPE REQUIREMENTS PROCESS CONNECTIONS ELECTRICAL CONNECT Vertical, horizontal, angle. Upstream: 20 x D. Downstream: 5 x D. MNPT, ANSI Class 50 RF, RF, RF, Welded Flange. 3/" FNPT. TABLE 6 - ELECTRONIC SPECIFICATIONS AMBIENT TEMPERATURE -5 F to 9 F F (-2 F to 65 F C). 55 Ambient Temperature Range for Electronics Figure 2 TRANSMITTER Microprocessor-based. DISPLAY Two lines, simultaneous rate and total, 6 alphanumeric characters each. FUNCTIONS OUTPUT SIGNAL ENCLOSURE PROTECTION ENCLOSURE APPROVALS* Zero, span, hi cutoff, low cutoff, flow rate units, response time, sample time, and engineering units, data logger, RS-232 interface. -20mA into Ohm or less. 5V TTL pulse output. Use or 20 gauge twisted pair shielded cable. NEMA X/IP 66. UL, CSA, FM Class I Groups B, C, D Class II Groups E, F, G KEMA/CENELEC EEx d IIB *Designed to meet. Contact Aalborg for status of the agency approval. www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 BULLETIN EM200

VORTEX INSERTION FLOW METERS Flow Meter Pressure Rating ANSI Flange Pressure - Temperature Ratings. Maximum Pressure in psig. TABLE 7 - FLOW METER PRESSURE RATING MATERIAL TEMP. F F -0 to 0 200 00 500 30L SS/36L SS 50# RF 230 95 75 60 5 30L SS/36L SS # RF 505 55 5 30 360 30L SS/36L SS # RF 200 5 9 25 765 720 30L SS/36L SS 900# RF 500 500 360 20 5 0 30L SS/36L SS 500# RF 500 500 500 500 500 500 Flow Ranges Minimum and maximum flow rates to achieve accuracy. Pipe ID based on schedule 0 steel. TABLE - WATER FLOW RATES AT 60 F F " 5" 6" " " 2" " min max min max min max min max min max min max min max Gal/min 52. 90.3 2. 7.6. 270. 205.7 675.0 32. 7372.0 60.5 66.3 556.6 26.9 L/MIN 9.2 505.6 3.7 70.7 9.9 22.3 77.6 7696. 227. 27905. 73.2 396. 26.7 70. 6" " 20" 2" 30" 36" min max min max min max min max min max min max Gal/min 727. 652. 920.3 2095. 3.7 2599.0 65.2 37595. 262.5 596.2 35.6 596.2 L/MIN 2752.2 6259.0 33.5 7969.9 329. 9395.3 626.6 23. 993.6 22576.9 556.7 33033.6 BULLETIN EM200 www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 56

VORTEX INSERTION FLOW METERS Minimum and maximum flow rates to achieve accuracy in (lb/hr). Pipe ID based on schedule 0 steel. TABLE 9 - SATURATED STEAM FLOW RATES AT SELECTED PROCESS PRESSURES (English) Pressure (psig) 25 50 75 0 25 50 200 250 350 00 50 500 550 " 6" " " 2" " 6" " 20" min max min max min max min max min max min max min max min max min max 257.3 36. 70. 577.5 67.3 76.0.7 05.6 5.5 29.0 20. 56.7 669.2 7. 905.0 209.2 2.3 75. 902.2 6206. 206.9 2663.6 272.3 3722.0 5635.6 505. 625.2 739. 79639.6 327.5 973.0 5966.0 0.7 5.2 739. 90.0 60.2 20. 33. 5.2.7 2026. 2233.5 232. 262.6 22.2 2995.5 375. 75. 22.0 75.0 252.9 3250.7 37.0 539. 5559.3 7757. 90. 9303.6 70. 25225. 36.0 526.6 66620.7 5.0 75.3 66.7 3. 530. 733. 925. 222.0 263. 2925.0 3223.3 3509.9 377.7 05. 322.9 52. 90.7 706.0 2700. 36776.0 639. 55967. 655.0 5. 3557.7 2260. 6.3 620.2 720.5 20035.5 22039. 206.2. 360.0 7.3 2269. 269. 2.6 3335. 3952.0 525. 5065.6 552. 607. 6559.6 702. 76.5 7935. 97.2 2956. 6773.9 636. 0353.6 9692.6 36.3 6356. 793. 2239.9 256.2 2797. 32972.7 375. 360.5 63.9 593.9 23. 29. 3576.6 76.0 732.0 5256. 622.3 732.0 793.3 797.3 9579.5 337. 76.6 79.7 2506. 2960.7 656.9 7375. 0373.2 26636. 52752.5 79.0 230656.3 226. 33725. 37203.0 39976.5 9322. 5705. 60. 656293.7 2262.9 303.0 33.3 5077. 592. 67.2 762.3 2. 25.5 33. 29.7 3.3 676.9 5725. 6750.9 7755.2 2393.9 669. 655.7 2502. 7979.5 2666.7 2537.0 3276.7 0273. 7527.9 59722. 6266. 700269.6 776662.6 5325.2 93757.3 273. 3677.6 995.3 636.7 765.2 9.2 90. 66. 2237. 3697.7 509. 636.5 7737.7 9005.3 202. 25.0 523.9 7996.0 260. 72220.2 2723.2 262092.6 3067. 395759. 955.9 5732.0 66362.5 759.2 6305.5 93629.7 33.9 2606.2 3572.6 0.3 6525.7 06. 9360. 606.7 7. 3960. 596.2 79.2 97. 272. 237.9 227.9 266.2 203.9 6693.5 373. 65230.2 2292.6 235. 323. 005. 57007. 633529.7 750273.3 67900. 9690.2 55.5 22693.7 307. 756.9 522.0.9 259.7 7.0 7.7 325.2 92.0 7670.0 2023. 2269.2 295.6 2777. 29329.3 325.3 3373.7 350. 77.0 32.2 20936.3 2766.5 35927.3 33370.7 507323.3 6539. 075.6 996.0 952. 227. 39936.0 552026.3 706222. 6956.2 Minimum and maximum flow rates to achieve accuracy in (kg/hr). Pipe ID based on schedule 0 steel. TABLE 50 - SATURATED STEAM FLOW RATES AT SELECTED PROCESS PRESSURES (Metric) Line Size (mm) 0 50 200 250 350 00 50 500 Pressure (bara) min max min max min max min max min max min max min max min max min max 2 6 22 26 2 30 32 3 36 3 0 73. 3. 7. 225.0 3. 35. 53.2 56.6 576.7 605. 63. 662. 690.0 77.3 7.2 770. 329.7 253.6 72.5 739. 59.7.6 20. 2. 29303.6 357.7 3303.2 36069. 339.0 06.7 299. 5270.6 5. 77. 27.2 353..7 606.0 72.7 2. 906.9 952.6 997.5.6 5. 27.9 70.2 22.0 2090.9 3999.7 766.9 226.0 227.6 2566. 32.7 39066.7 6079. 9607.9 535.6 567. 60302. 6390.0 67536.2 76. 66.6 256.7 396.0 5. 705.6 7.9 29. 73.0 309. 375.5.3 50.0 566.7 62.5 69.6 79.9 30.9 577.9 62.5 620.6 2637. 36336. 639.7 5606. 6653.0 7625.9 7676.9 93.0 7067.6 92273.0 975.6 272. 2.. 65.5.3 22.6 5.7 7.5 2030.7 2266.9 23.3 293. 2603.7 272.2 29.3 2925.0 3029.5 5226. 9997.6 95.7 2060.7 556.9 62907. 02.7 9765.6 5.0 2000.5 3266.0 775.0 50733.5 5975.2 6. 77939.3 5.5 700. 0. 393.7 925.3 237.3 207. 3200.5 3572.9 3753.0 3929.9 3.6 27.7 3. 6. 77.7 237.2 5757.0 30.5 225. 79. 996.5 2667. 53906. 532.6 953.2 20907. 223.3 237567.6 25770.7 26606. 206. 65.3 99.5 533.9 97.7 2733.5 339. 396.5 5.0 5072.7 532.5 5579.5 526.2 6069.2 630.7 655.3 6779. 695.0 2237.5 255. 62790. 953. 766.2 79555.5 253. 257736.3 27773.6 2973.9 3727. 337293.7 3575.9 377752.9 397.6 779.9 20.9 53. 239. 3303.6 096.3 7.9 59.7 630.7 639. 673.2 70.3 733.9 762. 79.3 92.9 3. 27037.3 5793.3 756. 2326.3 702.2 27003.3 2605.9 39.3 33533.0 3593. 332.0 07639.2 320.0 56536. 23.7.9 570. 22.7 32. 35. 535.3 6293.9 77.2 00.9 2.7 09. 99.6 952. 9960.3 333. 703.0 6. 35320.7 6766.2 9935. 60966.2 22225.3 236. 399.2 06920.6 302. 6903.7 5007.3 53252.0 56365.3 59605.9 6263.6 29.6 97.3 3065.3 395.2 562.6 6773.2 7966. 900.6 37. 6.3 9.9 62.9 22. 2607. 3079. 357.0 23370.9 706. 560. 2579. 203739.6 2302.3 357.5 36669.2 5505.3 5593.7 593. 633976.3 67036.3 7333.7 75.5 795692.6 57 www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 BULLETIN EM200

VORTEX INSERTION FLOW METERS Minimum and Maximum Flow Rates to achieve Accuracy in CFPM (77 PSIA and 70 F F). PipeID Based on Schedule 0 Steel. TABLE 5 - AIR FLOW RATES AT 60 F F CONDITIONS DENSITY (lb/ft3) 0.076 0.3 0.2 0. 0.232 0.2 0.336 0.3 0.0 0.93 0.55 0.596 0.69 0.700 0.752 0.0 0.56.6.636 PRESSURE (PSIG) 0 5 20 30 0 50 60 70 0 90 0 20 30 50 200 " 6" " " 2" " min max min max min max min max min max min max 59.2 7.9 3.7.9 2.2 2.2 59.0 75.0 90.2 20.9 29.0 232.9 26. 259.2 27.9 2.2 296. 353.6 56.3 97.9 605.3 202. 227.7 362.6 57.5 5272. 6037.3 6902.2 777. 532.0 936.9 6. 976.7 79.6 2606.5 32. 795.9 256. 3. 63.0 9.6 237. 2.6 322.2 360.3 396.5 3.2 6.3 96. 527. 557.7 57. 66.2 6.2 67.7 0.5 3.2 275 363 562 609 256 3 950 3797 56 790 9337 2 2303 27 26725 2572 309 3965 523 257. 32.9 363. 56. 50.3 6.2 69. 760.9 27. 9.3 952.9 2.7 70. 27.3 2. 236.3 29.0 53.2 9.9 52 693 756 230 56 939 22936 26 26 3357 376 066 206 775 5296 5 536 76 560 05 93 573 79 52 97 9 99 30 5 502 596 6 777 6 99 2032 225 329 2 07 302 939 2977 3056 3652 70 732 5295 550 609 69979 75266 05 62 92030 996 756 576 700 2 209 33 57 702 5 99 232 2265 2396 2522 265 2766 2 32 659 5625 959 27523 355 336 537 5929 67 753 30 90976 9907 639 77 22703 3063 70293 29609 696 6 9 23 6 672 70 205 223 2 2577 2739 296 309 39 333 36 60 536 93 7 236 3326 255 523 62030 76 205 90792 0379 9967 955 292 3729 37 5790 20 307 BULLETIN EM200 DENSITY (lb/ft3) 0.076 0.3 0.2 0. 0.232 0.2 0.336 0.3 0.0 0.93 0.55 0.596 0.69 0.700 0.752 0.0 0.56.6.636 PRESSURE (PSIG) 0 5 20 30 0 50 60 70 0 90 0 20 30 50 200 6" " 20" 2" 30" 36" min max min max min max min max min max min max 909 5 25 62 90 2 22 26 2923 3 3366 3577 372 392 77 367 553 53 70 7 2669 30930 352 5597 697 9 935 6063 56 3 3630 5652 6675 97 9379 20622 2653 39076 5 399 627 200 26 276 309 302 3699 395 26 52 7 500 527 552 5763 67 75 23 3225 3950 55000 705 670 2552 2 3253 503 65953 9765 23505 229355 25205 2656 30307 92 30 73 202 2536 2 33 3 227 597 952 5295 5627 599 6263 6569 669 762 56 2 2953 300 6 63 039 7735 273 727 6622 65 2062 225909 25605 26530 2996 30692 3237 2266 6923 206 25 292 3667 32 967 5555 6 669 762 765 3 60 905 9502 993 35 236 5950 75 56 70362 9 27335 552 30 2279 22 269767 2925 3267 355227 3373 2200 067 6973 6606 967 35 203 7 630 7257 303 927 220 3 972 200 3603 33 52 52 6606 73 2066 2666 69995 9303 76 65227 223 26059 30075 35569 03307 50923 9539 5655 59377 637 69003 73669 7235 2235 97 57 6799 52 096 55 299 2 56 6655 709 92 20009 265 22095 232 207 27 37090 97377 309 63620 22963 2966 3623 259 93 5677 627320 693503 75906 260 9229 9553 2777 920 2223 20663 www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 5

VORTEX INSERTION FLOW METERS Flanged Insertion Meter -/2" MNPT Insertion Meter Note Note -/2" Insertion Meter Assembly with Insertion Tool and Ball Valve -/2" Welded Insertion Meter Note Note : Length dependent on pipe diameter, thickness, and mounting. 59 www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 BULLETIN EM200

ORDERING INFORMATION VORTEX FLOW METERS MODEL STYLE W F I Wafer Flange Insertion SIZE: WAFER or FLANGE 07 3/" (20mm).0" (25mm) 5.5" (0mm) 20 2.0" (50mm) 30 3.0" (0mm) 0.0" (0mm) SIZE: INSERTION 0"-36" PIPE DIAMETER FLUID TYPE G Gas L Liquid S Steam MAX TEMP. 50 F F 6 F F MATERIAL S 30 SS S6 36 SS To allow us to confirm selection please return completed application data sheet found on Aalborg's web site at www.aalborg.com.. Select style (wafer, flange or insertion). 2. Select meter size to match internal pipe diameter (for insertion style select pipe diameter). 3. Confirm minimum and maximum flow ranges to maintain stated accuracy from liquid, steam, or air from Tables 3 to 3 are within your requirements.. For other gas applications consult factory. 5. Select fluid type. 6. Select maximum temperature capability. 7. Select desired **Material of Construction.. Select mounting connection. 9. Confirm maximum pressure capability of flange/meter rating with process conditions and select flange rating from Table 39.. Confirm suitability of standard local mounted electronics.. Select desired transmitter power. 2. Provide: Fluid, Fluid Viscosity, Minimum & Maximum Operating Pressure, Minimum & Maximum Operating Temperature, Density/Specific Gravity or Specific Volume. 3. Provide minimum and maximum flow range. Options: Remote mount electronics up to 0 ft. (30.5 m). = Flange and Insertion Style. Wafer Style for Alignment Ring Selection. ** = The selection of materials of construction, is the responsibility of the customer. The company accepts no liability. MOUNTING CONNECTION A Wafer. Using Customer Flanges. B Flange Mounting. C Insertion with Flange. D Insertion. With.5 MNPT Thread. E Insertion, Welded. F Other. FLANGE RATING A 50# ANSI RF (Alignment Rings Not Required for Wafer Style) B # ANSI RF (Wafer Style Includes Alignment Rings) C # ANSI RF (Wafer Style Includes Alignment Rings) D OTHER N NONE DISPLAY L Local R Remote POWER 0 2VDC 2 20VAC 22 220VAC BULLETIN EM200 W L S A B L 22 EXAMPLE: W-L-SAB-L22 SPECIFY: FLUID NAME OR MEASURING DENSITY, FLOW RATE, and PRESSURE (STEAM, GASES). Vortex meter, Wafer style, " diameter size, Liquid at maximum 50 F, 30 stainless steel, Customer flanges, Flange # ANSI RF, Local display, 220V power. www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 60