Steam Turbine Seal Rub

Similar documents
Artesis MCM Case Studies. March 2011

EnVibe, Inc. Houston, Texas. Carbon Seal Rub on a Steam Turbine

Balancing of aeroderivative turbine

Gearbox Misalignment on Combustion Gas Turbine Generator

CASE STUDY ON RESOLVING OIL WHIRL ISSUES ON GAS COMPRESSOR

PLACE FOR TITLE AUTHORS. Potassium Carbonate Pump Failure High Axial Movement due to Uncontrolled (unbalanced) forces.

Balancing with the presence of a rub

ISCORMA-3, Cleveland, Ohio, September 2005

GENERATOR SEAL OIL SYSTEM

Table of Contents. 4. Before a New Turbocharger is Installed

IDENTIFICATION OF ABNORMAL ROTOR DYNAMIC STIFFNESS USING MEASURED VIBRATION INFORMATION AND ANALYTICAL MODELING

IMPACT OF WIRELESS LASER BASED SHAFT ALIGNMENT ON VIBRATION AND STG COUPLING FAILURE. Ned M. Endres, Senior MDS Specialist

The table below provides information on the five vacuum pump-out units evaluated in this study.

Application Note. Case study Early fault detection of unique pump bearing faults at a major US refinery

Throwback Thursday :: Bently Nevada Dual Probe Versus Shaft Rider

Operation & Maintenance Manual for Northern Magnetic Drive Pumps. Operation Manual. Northern Magnetic Drive 4400 and 4600 Series

Reassess your Pump Startup (S/U) and Shutdown (S/D) Procedures By Heinz P. Bloch For TECÉM tecem.com.br Oct,05,2013

AERO AERODERIVATIVE AND INDUSTRIAL GAS TURBINES NON INTRUSIVE SENSOR SYSTEM

Identification and Elimination of High Vibration Caused by Misalignment Induced Oil Whirl without Stoppage of the Machine A case study

INVESTIGATION OF HIGH VIBRATION ON LOW PRESSURE STEAM TURBINES

Case History: Field Balancing of a Bowed Steam Turbine Rotor. My Background

Case Study - Fluidic Instability

ELIMINATION OF REPETITIVE THRUST BEARING FAILURES ON A PROCESS AIR COMPRESSOR

Dynamic characteristics of railway concrete sleepers using impact excitation techniques and model analysis

Appendix G Examples and Recommended Methods

Effect Of Main Steam Temperature At Inlet On Turbine Shaft Vibration

FTM-L SERIES SINGLE OR TWIN DIRECT STEAM MIXER KETTLE COMPLETE WITH HYDRAULIC POWER TILT BRIDGE PARTS AND SERVICE MANUAL

SHAFT ALIGNMENT FORWARD

Perform Vibration Analysis

Effects of shaft geometric unconformities on the rotor-dynamic behavior in hard coupled equipment

Routine Compressor Maintenance

FPS- 80. Manual. Reverso Pumps, Inc. Ph: (954)

Vibration studies and on-site balancing of GT-1 assembly

Abrupt Stoppage of Turbine Rotor, running on Barring after Major Overhauling

Delayed Coking. Process Overview

PLACE FOR TITLE. Analysis and on-stream countermeasures AUTHORS of subsynchronous vibration of a centrifugal compressor SANGJOO LEE

ENGINE TECH TIPS. Subject: OIL IN TURBOCHARGER AND AIR PIPING

EA Closing Report Page 1 of 9

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS

The original design of the machine was reviewed and some indications are provided

Fault Diagnosis of Lakvijaya Power Plant: A Case Study of an Anti-Rotational Pin Failure

TEST DATA REPORT TRGA Homogenizer on the Boiler Nr.5, Heat Station (Period of Tests: )

Table of Contents. Equipment Summary...3. Performance and Value Vs. New Equipment...3. Reliability.. 3

TURBOGENERATOR DYNAMIC ANALYSIS TO IDENTIFY CRITICAL SPEED AND VIBRATION SEVERITY

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE

Application Engineering

PNEUMATIC HIGH SPEED SPINDLE WITH AIR BEARINGS

Troubleshooting:Passenger Car

[ 1. Brakes ] Top 10 Visual IR Thermometer Automotive Applications. Application Note. See what you ve been missing.

A Different Perspective of Synchronous Thermal Instability of Rotating Equipment (STIR) Yve Zhao Staff Machinery Engineer 3/15/2017

Expand your vibration program to new heights.

Disassembly and Assembly

XY Measurements for Radial Position and Dynamic Motion in Hydro Turbine Generators

AIRCRAFT ENGINE MECHANIC, 8602

Experiences in a Motor Protection Retrofit

Evaluation of a Gearbox s High-Temperature Trip

Schuyler McElrath Gas Turbine Consultant JASC: Jansen s Aircraft Systems Controls, Inc

Separation Seal Upgrade to overcome Repetitive Failures

A. Perform a vacuum gauge test to determine engine condition and performance.

SPECIFY THE RIGHT HOT OIL PUMP FOR YOUR APPLICATION

11 Problems 11 Solutions Case Histories of 11 Machinery Vibration Problems Part 1

9/28/2018. Refrigeration compressor operation, maintenance and safety

Troubleshooting. This section outlines procedures for troubleshooting problems with the operation of the system:

Installation Vertical Pump: Installation 'CM' and 'CDM' Style: Operation:

Storvik HAL Compactor

Maintenance Information

Copeland Screw Compressors Semi-Hermetic Compact Operating Instructions

TIGER Diagnostic Report

Prodigy HDLV System Troubleshooting - Generation III

TIGER Diagnostic Report

Operating Conditions that shorten Gas Engine Oil Life NNAMDI J. ACHEBE CLS, OMA I, MLT II, MLA III

Copeland Screw TM Compressors

Carbon Brush Performance on Slip Rings

Diagnostic Procedures

LEAK TEST PROCEDURE APPLICABLE TO DC3 INTELLI-GRIP LIFTERS MODELS MRT4-DC3, MRTA8-DC3, MRTALP8-DC3 AND PC/P1-DC3 SERIES

Subsynchronous Shaft Vibration in an Integrally Geared Expander-Compressor due to Vortex Flow in an Expander

GROUP 13C 13C-1 CONTENTS GENERAL DESCRIPTION... 13C-2 FUEL TANK... 13C-11 FUEL SUPPLY DIAGNOSIS... 13C-3 SPECIAL TOOLS... 13C-8

McNary Northshore Fishway Hydro Project. History & Lessons Learned

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

Hydraulic Brake System, Bosch 42.15

11 Problems 11 Solutions Case Histories of 11 Machinery Vibration Problems Part 2

TURBOCHARGER WARRANTY ANALYSIS GUIDELINES

Section 3 Technical Information

Maintenance Information

Failures of Rolling Bearings in Bar and Rod Mill

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

CONTENTS. EMERGENCY PUMP USE Electric Pump...H-3 Manual Pump...H-5

More Than Air. Answers. Online answers:

Technical Service Bulletin IOX/DCX Transmitter Maintenance Schedule

Grid Stability Analysis for High Penetration Solar Photovoltaics

SPEED PROBE INSTALLATION GUIDELINES PAGE 1 DOCUMENT REFERENCE: LCC /26/2000

LED TROUBLESHOOTING. Controller Version L610 Rev 7M or newer (manufactured after 1/21/15)

INVESTIGATION REPORT PREPARED FOR: UNIVERSITY OF NORTHERN IOWA CEDAR FALLS, IA

VACUUM PUMP-3A. Running Hour: 8646 Ref Speed: 660 RPM OBSERVATION. Peakvue reading was 0.3 at Vacuum Pump NDE bearing.

Medium and high pressure pumps

ELECTROMECHANICAL OPTIMIZATION AGAINST TORSIONAL VIBRATIONS IN O&G ELECTRIFIED TRAINS MICHELE GUIDI [GE O&G] ALESSANDRO PESCIONI [GE O&G]

Steam Turbine Generator Core Isolation Issues at the Redhawk Combined Cycle Plant

MAINTENANCE INSTRUCTIONS

P.O. Box 435 Saratoga Springs, NY 12866

PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS

Transcription:

Steam Turbine Seal Rub Date : November 19, 2014 Steam Turbine Seal Rub Vibration data helps to identify a steam turbine seal rub. Sotirios Christofi Deputy Manager, Head of Mechanical Maintenance, Thessaloniki Refinery s.c.christofi@helpe.gr Executive Summary This case history describes how the vibration data provided by System 1* software helped to identify an appropriate course of action following severe vibration events experienced by a Steam Turbine driver of a recycled gas compressor in an oil refinery owned by Hellenic Petroleum SA in Thessaloniki, Greece. A few months after its commissioning, the turbine instrumentation began to indicate brief periods of elevated vibration. These spikes in high vibration gradually appeared with increasing frequency and

increased observed amplitudes. In August 2012, the observed vibration closely approached turbine trip limits. Based on the measurements shown by System 1, the operations and maintenance staff decided to wait until the next plant shut down for troubleshooting. The turbine was in operation for another six months, with occasional periods of high vibration noted. In February 2013, the turbine was disassembled and inspected. The findings indicated that the reason for the peaks was oil in the vacuum chamber, which touched the turbine shaft from time to time. The oil had leaked through the oil labyrinths, which had worn unevenly because of misalignment. Steam Turbine Nameplate Data & Construction Power at shaft, rated / normal : 1485 / 1150 kw Shaft speed, rated/normal : 9250 / 9466 rpm Steam flow, rated/normal : 24020 / 18660 kg/h Steam inlet pressure / temperature : 40 barg @ 380 o C Steam exhaust pressure / temperature : 10 barg @ 250 o C The drawing in figure 1 shows a cross section of the non-drive end (NDE) of the turbine. The bearing lubrication oil is contained by the oil labyrinth. Any oil leaking past the lip seals of the oil labyrinth normally flows to the drain. Any evaporated oil fumes are evacuated from the space between the oil and steam labyrinth by the vacuum separation system.

Figure 1: Turbine cross-section drawing Non-Drive End The vacuum chamber therefore collects flow suctions from two directions: the steam leaking from the steam labyrinth seal and the evaporation, if any, of the oil leaking from the oil labyrinth seal. A similar arrangement exists on the drive end (DE) of the turbine. Vibration Instrumentation Figure 2 shows a System 1 view of the steam turbine monitoring instrumentation. In addition to temperature and Keyphasor* (speed and phase reference) monitoring, there are proximity probes VE-14375X/Y and VE-14376X/Y that measure the horizontal and vertical distance between the inner surface of DE and NDE bearings and the shaft. These non-contacting proximity transducers measure the vibration of the turbine rotor within the clearance of its oil-film bearings.

Figure 2: Steam turbine vibration instrumentation communicating with System 1 software Sequence of Events The steam turbine was commissioned in January 2011 and started normal operation in September 2011. From initial startup to February 2012 turbine operation was smooth. Vibration levels were consistently low and no high-amplitude spikes were observed. Levels were measured in the five to 15 micron range, which was well within the normal operating parameters of the machine. The alert alarm was set at 63 microns and the danger alarm was set at 85 microns. Intermittent High Vibration Observed From February 2012 to the end of August 2012 brief periods of high vibration were observed, with peaks levels reaching as high as 40 microns. On August 30 and 31, and again on September 2, the observed peaks climbed as high as 83 microns, almost reaching the trip setpoint of 85 microns (Figure 3). A review of vibration data revealed that 90% of the observed high vibration could be attributed to 1X (synchronous) vibration.

O

Figure 3: System 1 vibration trend, showing occasional spikes of high vibration that occurred over a period of two weeks. Note: The alert alarm set point (57 microns) is indicated with a dashed line. A closer evaluation showed that the brief recurring periods of high vibration started at normal levels of 10 to 15 microns, climbed quickly to a peak value as high as 50 to 80 microns, and then rapidly dropped back down to normal levels. Each event lasted from about five to 15 minutes (Figure 4). The peaks appeared at intervals ranging from eight hours to three days. During some of the high vibration occurrences, operators who were near the turbine reported that they could feel and hear significant increases in machine vibration.

O

Figure 4a: This System 1 plot show the phase and amplitude (both unfiltered and 1X-filtered) trends. The orbit plot shows the behavior of a typical brief period of high vibration. In this example, vibration amplitude rose from normal levels (eight microns) to a peak value of 74 microns in about four minutes and then back down to normal again in about the same amount of time. Figure 4b: The orbit plot on the left shows the overall broadband amplitude, while the orbit on the right indicates its 1X-filtered constituent, which more than 90% of the overall vibration. Initial Investigation and Actions Defects such as misalignment, imbalance and looseness can often produce low-frequency vibration corresponding to running speed of the rotor (1X). However, these defects were ruled out because they would have caused constant vibration rather than the observed intermittent periods of high vibration. The orbit plots were then reviewed (Figure 5). The shape of the orbits indicated the presence of a light intermittent rub, which can sometimes occur with the buildup of carbonized oil on rotor shaft seals.

O

O

Figure 5: The orbit plots during the intermittent vibration peaks show changing phase angles, a classic indication of rub caused by thermal bow with a wandering hot spot. The next plant shutdown was not planned for another six months, when an outage was scheduled to occur. In order to minimize the potential for damage caused by continued operation with an intermittent seal rub, we decided on the following steps: 1. Evaluate lubricating oil for possible replacement: The oil was analyzed and found to be in good usable condition. No replacement was needed. 2. Perform maintenance and cleaning of the oil clarifier: This routine maintenance was performed with no major findings. 3. Check oil pressure upstream of flow-control orifices: Oil pressure was checked and verified to be normal. 4. It had been noted that pressure in the vacuum chamber was slightly higher than specified. The pressure was reduced to match the specification. No noteworthy change in the vibration was noted after these actions were completed. After consulting with GE specialists, it was agreed that it would be acceptable to operate the turbine with an intermittent light rub until the planned outage, provided that vibration indications remained within the previously observed ranges. Turbine Maintenance & Findings In February, 2013 the steam turbine was disassembled for general inspection during the scheduled outage. Inspection Results Unusually high misalignment was found among the turbine bearing supports (offsets of up to 1 mm). Carbonized lubricating oil had built up in the seal vacuum chamber and was coming in contact with the turbine rotor (Figure 6). One-sided wear of the oil labyrinth rings was discovered (Figure 7). No significant damage had occurred to the rotor shaft, steam labyrinths or bearings.

Figure 6: Carbonized oil is visible in the vacuum chamber. Figure 7: This photo shows uneven (one-sided) wear of oil labyrinth rings Conclusions and Further Actions Based on the inspection results, the original diagnosis of an intermittent light rub was verified. The most probable failure scenario was summarized: Misalignment caused uneven wear on one side of the oil labyrinth rings. Excess oil leaked into the space between the oil rings and the vacuum chamber.

Powered by TCPDF (www.tcpdf.org) O The oil vapor mixed with high temperature steam in the vacuum chamber. The oil heated until it formed hard, carbonized coke, which built up until a rub occurred. Within a few minutes, the carbon deposits were abraded away through the rubbing action until the rub disappeared. But the leaking oil would form more coke and the cycle would eventually repeat itself.