Performance Analysis of Transient Stability on a Power System Network

Similar documents
Anupam *1, Prof. S.U Kulkarni 2 1 ABSTRACT I. INTRODUCTION II. MODELLING OF WIND SPEED

Journal of American Science 2015;11(11) Integration of wind Power Plant on Electrical grid based on PSS/E

GTG MW GTG MW STG 2 36 MW CB11 CB9 GEN TRAFO-4. GEN TRAFO-5 50 MVA 11/34.5 kv %Z. GEN TRAFO-2 50 MVA 11/34.5 kv 15.

Computer Aided Transient Stability Analysis

The Effect Of Distributed Generation On Voltage Profile and Electrical Power Losses Muhammad Waqas 1, Zmarrak Wali Khan 2

Grid Stability Analysis for High Penetration Solar Photovoltaics

Enhancement of Transient Stability Using Fault Current Limiter and Thyristor Controlled Braking Resistor

Power System Stability Analysis on System Connected to Wind Power Generation with Solid State Fault Current Limiter

FAULT ANALYSIS OF AN ISLANDED MICRO-GRID WITH DOUBLY FED INDUCTION GENERATOR BASED WIND TURBINE

CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM

Transient stability enhancement of 30 bus multi- machine systems by using PSS & increasing inertia

Voltage Sag Mitigation in IEEE 6 Bus System by using STATCOM and UPFC

Analysis of Grid Connected Solar Farm in ETAP Software

Power Flow Simulation of a 6-Bus Wind Connected System and Voltage Stability Analysis by Using STATCOM

Implementation of FC-TCR for Reactive Power Control

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators

Review paper on Fault analysis and its Limiting Techniques.

Co-Ordination Control and Analysis of Wind/Fuel Cell based Hybrid Micro-Grid using MATLAB/Simulink in Grid Connected Mode

Enhancement of Power Quality in Transmission Line Using Flexible Ac Transmission System

Electric Power System Under-Voltage Load Shedding Protection Can Become a Trap

CHAPER 5 POWER FLOW STUDY IN THE INTEGRATED GRID NETWORK

Simulation of real and reactive power flow Assessment with UPFC connected to a Single/double transmission line

Development of Electrical Power System Simulator.

APPLICATION OF STATCOM FOR STABILITY ENHANCEMENT OF FSIG BASED GRID CONNECTED WIND FARM

Evaluation of the Performance of Back-to-Back HVDC Converter and Variable Frequency Transformer for Power Flow Control in a Weak Interconnection

Dynamic Behaviour of Asynchronous Generator In Stand-Alone Mode Under Load Perturbation Using MATLAB/SIMULINK

Transient Stability Analysis of IEEE 9 Bus System Using Power World Simulator

Performance of DC Motor Supplied From Single Phase AC-DC Rectifier

Enhancement of Power System Stability Using Thyristor Controlled Series Compensator (TCSC)

Load Frequency Control of a Two Area Power System with Electric Vehicle and PI Controller

Statcom Operation for Wind Power Generator with Improved Transient Stability

Simulation of Voltage Stability Analysis in Induction Machine

COMPARISON OF DIFFERENT SOFTWARE PACKAGES IN POWER FLOW AND SHORT-CIRCUIT SIMULATION STUDIES. A Project

Computation of Sensitive Node for IEEE- 14 Bus system Subjected to Load Variation

Generator Interconnection Facilities Study For SCE&G Two Combustion Turbine Generators at Hagood

Behaviour of battery energy storage system with PV

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz Fall 2011

Request for Payment Instructions Wholesale Distribution Access Tariff (WDAT) Attachment I - GIP

Comparative Analysis of Integrating WECS with PMSG and DFIG Models connected to Power Grid Pertaining to Different Faults

Georgia Transmission Corporation Georgia Systems Operations Corporation

Fault Rid Through Protection of DFIG Based Wind Generation System

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

PSAT Model- Based Voltage Stability Analysis for the Kano 330KV Transmission Line

An Alternative to Reduce Medium-Voltage Transient Recovery Voltage Peaks

Implementation SVC and TCSC to Improvement the Efficacy of Diyala Electric Network (132 kv).

Master of Engineering

Cost Benefit Analysis of Faster Transmission System Protection Systems

A Cost Benefit Analysis of Faster Transmission System Protection Schemes and Ground Grid Design

REDUCING VULNERABILITY OF AN ELECTRICITY INTENSIVE PROCESS THROUGH AN ASYNCHRONOUS INTERCONNECTION

Wind Farm Evaluation and Control

Effect of prime mover speed on power factor of Grid Connected low capacity Induction Generator (GCIG)

Modelling and Simulation of DFIG with Fault Rid Through Protection

Investigation of Transient Recovery Voltage Across a Circuit Breaker with Presence of Braking Resistor

Network Reconfiguration for Loss Reduction and Voltage Profile Improvement of 110-Bus Radial Distribution System Using Exhaustive Search Techniques

International Journal of Emerging Technology and Innovative Engineering Volume 2, Issue 4, April 2016 (ISSN: )

VOLTAGE STABILITY IMPROVEMENT IN POWER SYSTEM BY USING STATCOM

TRANSMISSION LOSS MINIMIZATION USING ADVANCED UNIFIED POWER FLOW CONTROLLER (UPFC)

Integration of Large Wind Farms into Electric Grids

New York Science Journal 2017;10(3)

Performance Analysis of 3-Ø Self-Excited Induction Generator with Rectifier Load

CONNECTION OF NEW GENERATORS IN THE ELECTRICAL POWER SYSTEM OF KOSOVO. Rexhep Shaqiri 1, Bogdanov Dimitar 2.

EL PASO ELECTRIC COMPANY SHORT CIRCUIT ANALYSIS FOR XXX S PROPOSED GENERATION INTERCONNECTION

6545(Print), ISSN (Online) Volume 4, Issue 2, March April (2013), IAEME & TECHNOLOGY (IJEET)

Simulated Switching Transients in the External Grid of Walney Offshore Wind Farm

Impact of Islanding and Resynchroniza?on on Distribu?on Systems

Transient Stability Assessment and Enhancement in Power System

Dynamic Reactive Power Control for Wind Power Plants

Power Quality and Power Interruption Enhancement by Universal Power Quality Conditioning System with Storage Device

/12/$ IEEE. M. Bashir M.Sc student, Student Member, IEEE Ferdowsi University of Mashhad Mashhad, Iran

DISTRIBUTED GENERATION FROM SMALL HYDRO PLANTS. A CASE STUDY OF THE IMPACTS ON THE POWER DISTRIBUTION NETWORK.

CONTROL AND PERFORMANCE OF A DOUBLY-FED INDUCTION MACHINE FOR WIND TURBINE SYSTEMS

Transient Stability Analysis of Power System with Wind Generators

Control Application of PV Solar Farm as PV- STATCOM for Reactive Power Compensation during Day and Night in a Transmission Network

COMPARISON OF DIFFERENT METHODS FOR EXCITATION OF SYNCHRONOUS MACHINES

Use of STATCOM for Improving Dynamic Performance of Wind Farms Connected in Power Grid

Study of Fault Clearing by A Circuit Breaker In Presence of A Shunt Capacitor Bank

Okelola, M. O. Department of Electronic & Electrical Engineering, Ladoke Akintola University of Technology, P.M.B. 4000, Ogbomoso, Nigeria

Research on Transient Stability of Large Scale Onshore Wind Power Transmission via LCC HVDC

Modelling and Simulation of DFIG based wind energy system

(by authors Jouko Niiranen, Slavomir Seman, Jari-Pekka Matsinen, Reijo Virtanen, and Antti Vilhunen)

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering. (An ISO 3297: 2007 Certified Organization)

Islanding of 24-bus IEEE Reliability Test System

DC Voltage Droop Control Implementation in the AC/DC Power Flow Algorithm: Combinational Approach

APPLICATION OF VARIABLE FREQUENCY TRANSFORMER (VFT) FOR INTEGRATION OF WIND ENERGY SYSTEM

Renewable and Distributed Energy Resource Technologies

Reactive Power Compensation using 12 MVA Capacitor Bank in 132/33 KV Distribution Substation

Identification of Best Load Flow Calculation Method for IEEE-30 BUS System Using MATLAB

POWER FLOW SIMULATION AND ANALYSIS

A Transient Free Novel Control Technique for Reactive Power Compensation using Thyristor Switched Capacitor

Improving Power System Transient Stability by using Facts Devices

Intensification of Transient Stability in Grid Connected Squirrel Cage Induction Generator Using Plugging Mode Operation

DYNAMIC BEHAVIOUR OF SINGLE-PHASE INDUCTION GENERATORS DURING DISCONNECTION AND RECONNECTION TO THE GRID

TRANSMISSION PLANNING CRITERIA

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz

2013 Grid of the Future Symposium. Utilizing Single Phase Operation Scheme on Untransposed 765kV lines for a Stability-Limited Plant

INVESTIGATION OF THE IMPACT OF SWITCHING A HEAVILY LOADED TRANSMISSION LINE ON OPERATION OF A POWER PLANT WITH TURBINE-GENERATOR UNITS

PID 274 Feasibility Study Report 13.7 MW Distribution Inter-Connection Buras Substation

Possibilities of Distributed Generation Simulations Using by MATLAB

Power System Analysis for a Utility with Localized Wind Generation: Southern Negros Oriental Case

Transcription:

Performance Analysis of Transient Stability on a Power System Network Ramesh B Epili 1, Dr.K.Vadirajacharya 2 Department of Electrical Engineering Dr. Babasaheb Ambedkar Technological University, Lonere (MS) ramesh.epili@rediffmail.com 1,kvadirajacharya@dbatu.ac.in 2 Abstract Three phase fault on a power system network is most severe and uncommon. In order to maintain stability of power system, it is required to adjust the excitation system. A prior study of the effect of disturbance is required for proper designing of power system equipment s. This paper analyses the effect of a three phase fault on a power system 33kV/11kV/3.3kV/0.415kV system. Power flow analysis, transient stability study is presented using ETAP simulations. Keywords-Transient stability analysis, critical clearing time, three phase fault, ETAP. 1, INTRODUCTION For the last few years electrical engineers have been focusing on the power system studies using software tools. Recent advances in engineering sciences have brought a revolution in the field of electrical engineering after the development of powerful computer based software. This research work high- lights the effective use of Electrical Transient Analyzer Program (ETAP) software for Transient stability analysis.transmission networks of present power systems are becoming progressively more stressed because of increasing demand and limitations on building new lines. One of the consequences of such a stressed system is the risk of losing stability following a disturbance. Transients occur due to various disturbances like sudden change in the load, switching of the power electronics devices and capacitor banks, loss of the synchronous generators. Period of duration for the occurrence of this events is very short, even the generators AVR s response time is too large to respond to such an event. If these events are not monitored properly this will result in severe stability problem that may get effect on the system performance and system stability[1-6]. This analysis can be used to determine other things such as nature of the relaying system, critical clearing time of circuit breakers, voltage level and transfer capability between systems [7]. The literature shows an increasing interest in this subject for the last two decades, where the study of transient stability of a power system network carried out to determine the characteristic behaviour of system network subjected to the faults and other disturbances [5-10]. The main objective of this paper is to identify the problems in the power system network due to transient events thataffects the performance and stability of various equipment s which are being used. Refer of these Analysis would help in improving the Power system design and control by adopting differenttechniques. This paper shows the study of 33kV/11kV/3.3kV/0.415kV utility system. The system of 33kV main bus is fed by power grid source of short circuit 1200MVA.The 33kV main bus is step down to the Page 37

11kV,3.3kV,415Vrespective bus comprising of step down transformer of rating 10MVA and three winding transformer of rating 15/10/5MVA respective. Moreover, the conductors/cables, circuit breakers, and rest of power system elements are modelled according to their actual ratings in ETAP. This paper represents a novel approach to analyse the power system network by using ETAP with the help of one line diagram. The paper is organised as follows: Section I gives the introduction of transient stability in power system network.section II is the complete single line diagram of the system under consideration; this diagram is implemented based upon practical data in ETAP for simulation purpose system. Section III briefly describes the Load flow analysis. Section IV explains the system modelling. Section V and VI shows the creation of fault event and results of system network, generator behaviour when subjected to fault and cleared. Section VII gives conclusion. 2, SYSTEM STRUCTURE Fig.1. Single line diagram of 33kV/11kV/3.3kV/0.415kV Single line diagram of the 33kV/11kV/3.3kV/0.415kV utility system is under study. The 11kV bus Sub2A and Sub2B is interconnected which is fed to 1250 HP synchronous motor (Syn ABB) and 2500 HP (IND).Generator (Gen 1) of 10MW supplies at bus Sub2B. Three winding transformer T1 is connected to Sub2B of 11kV and Sub 3 at 3.3kV.Sub 3 supplies to 0.415kV through transformer T4, Capacitor (CAP1) of 450KVAR and Sub 3 Net. Main Bus of 33kV supplies to 11kV bus Sub 2A and 3.3kV bus Sub3. This diagram is implemented in ETAP to perform load flow study and Transients stability analysis.the system is analyse under steady state by using load flow analyses and 3-phase fault at Sub 3 for Transients analysis. Page 38

4, LOAD FLOW ANALYSIS Load flow studies have been performed at various monitoring points using ETAP, in which Newton Raphson (NR) method is used. Here number of iterations used is 99. Fig.2. Load Flow Analysis of 33kV/11kV/3.3kV/0.415kV of Power System Network Equipment Loading Size Generator 100 10MW Transformer T1 100 15/10/5MVA Transformer T2 100 10MVA Transformer T4 100 1.5MVA Synchronous 100 1250HP Motor Induction 100 2500HP Motor Capacitor 3x150 450KVAR Table 1. Loading of Equipment s Fig.2 describes percentage of the bus loading as the number transmission stages goes on increasing with the drop across the line increases. Table 1.describes the loading of equipment s. Three winding transformer used with 15/10/5MVA with the Base MVA of 15 MVA and the generator of 10MW is loaded with 7MW as a design criteria and 6MW with normal operation.table-2 provides the power flow report for the various monitoring points. From To Active Power Reactive Power Bus Loading Page 39

(MW) (KVAR) (Percent) Utility Main 1250MVA 33KVBus 1081 636 100 Main Bus Sub2A 3234 2062 98.5 Gen 1 Sub2B 6000 3024 101 Sub2A Sub2B Sub Tie 2754 1882 101 T1 Sub3 1790 542 99.73 Table 2. Power flow report. With Cap 450Kvar Sub3-282 99.73 5, SYSTEM Without MODELLING Cap Sub3 1790 823 99.59 The 450Kvar 33kV/11kV/3.3kV/0.415kV utility system consists of generator, exciter, governor, load and other equipment s. In this study we would like to establish the mathematical models of these components first. We will now illustrate the equivalent models of the important components for this system below. a. Excitation System: The response of the excitation also depends upon its parameters like maximum ceiling voltage, current and insulation factor for rotor to withstand the required temperature. The Fig 3 shows fixed excitation of a generator at excitation voltage 1.36 per unit.the Excitation system used in Fig 3.0 is Fixed Excitation purely because system has only one generator with less load requirement and also short-circuit level of this system is very high so better is the voltage regulation and hence very less amount of voltage will be require to drive the current in order to meet the load requirement. Fig.3. Fixed Excitation of a Generator(Excitation voltage vs Time) b. GovernorModel: The primary objective of a governor is to control the speed of the turbine so as to match the change in the electrical power output by adjusting the gate valve position in case of the hydro turbines Page 40

and reheat in case of steam turbine. This is achieved by the load frequency control of the system.isochronous governor work satisfactorily when the generator is supplying to an isolated load or when only one generator in a multi generator system is required to respond to changes in load but they cannot be used when two or more units are connected to same system. Governoroperation is in isochronous mode. Fig.4. Block diagram of Single Reheat Steam Turbine (ST1) 6, TRANSIENT STABILITY ANALYSIS The 33kV Main Bus which is considered to be a swing bus feeding to 11kV, 3.3kV and 0.415kV bus. Creating an Event in ETAP at fault t=0.5sec and fault cleared at t=0.7 sec using Newton- Raphson method with 99 iterations. The study of generator characteristics prior with response to the fault occurs and clears at Sub 3 also to study the impact on the bus voltage magnitude and angle at Sub 3 when the capacitor bank is on when subjected to these disturbances. Fault applied is a 3-phase fault at Sub 3. 7, SIMULATION RESULTS OF SYSTEM IN ETAP Page 41

Fig.5.Simulated diagram for 3-phase fault applied at Sub3 Fig.5.describes 3-phase fault at Sub 3 resulting in drop in bus voltage and bus frequency to zero at=0.5sec Fig.6. Simulated diagram after 3-phase fault cleared at Sub 3 Fig.6. describes 3-phase fault cleared at Sub 3 resulting in regaining normal voltage and frequency at t=0.7sec.the different plot for generator Gen 1 when fault on Sub 3 at0.5sec and cleared at 0.7sec are shown below in Fig.7,Fig.8,Fig.9,Fig.10,Fig.11,Fig.12,Fig.13. Fig.7.Generator Terminal Current Fig.10. Generator Electrical Power (MW vs Time) Page 42

Fig.8. Bus voltage at Sub 3Fig.11.Generator Terminal Current (Current vs Time) Fig.9.Generator Absolute Angle (Degree vs Time)Fig.12.Generator Speed Variation (RPM vs Time) 8, CONCLUSION AND FUTURE WORK Dynamic performance of a power system is significant in the design and operation of the system. The transient stability study determines the machine power angles and speed deviations, system electrical frequency, real and reactive power flows of the machines, power flows of lines and transformers, as well as the voltage levels of the buses in the system. These system conditions provide indications for system stability assessment. This paper mainly investigates the power system transient stability of the system 33kV/11kV/3.3Kv/0.415Kv which will be helpful in the power system operation and design of equipment s and also further analysis could be carried out for transient stability enhancement. Transient stability analysis will also be an important factor to be considered in the smart grid for the performance evaluation of equipment s in the power system design, operation, control and protection. This paper also covers an important aspect of maintaining generatorstability by the control of excitation voltage which helps in maintaining the reactive power control. 9, REFERENCES [1]Kavitha R, Transient Stability of IEEE-30 Bus System Using E-TAP Software International Journal for Scientific and Engineering Reasearch volume 3,ISSN 2229-5518. Page 43

Powered by TCPDF (www.tcpdf.org) International Journal of Advanced Research in [2] Hung-Cheng, Chen,Shang-Yi, Chen,Shun-Chung Shih, Transient Stability Analysis of an Industrial Cogeneration System National Chi-Yi University of Technology. [3]Rana A. Jabbar Khan, Muhammad Junaid, Muhammad Mansoor Asgher, Analysis and Monitoring of 132 grid using ETAP software. [4] Dr.Trilochan kaur, Sandeep kakran, Transient stability improvement of long transmission line using SVC International Journal of Advance Research in Electrical,Electronics and Instrumentation Engineering volume 1,ISSN 2278-8875. [5] Rohit Kapahi, Load Flow Analysis of 132kv Substation Using ETAP software [6] Jignesh S Patel, Manish N. Sinha, Power System Transient Stability Analysis using ETAP software. [7] P.K. Iyambo, R. Tzonova, Transient Stability Analysis of the IEEE 14- Bus Electrical Power System, IEEE Conf. 2007. [8]SwaroopKumarNallagavla,Mukeshkumarkirar,Dr.GangaAgnihotri, Transient Stability Analysis of IEEE-9 bus Electric Power System,International Journal for Scientific Engineering and Technology volume 1, ISSN 2277-1581. [9] P. M. Anderson and A. A. Fouad, Power System Control and Stability. New York: IEEE Press, 1994. [10] P. Kundar, Power System Stability and Control. New York: McGraw-Hill, 1994. [11] ETAP Operations Technology, Inc., Available: http://www.etap.com. Page 44