G2.1 RETROFIT LED LIGHTING

Similar documents
Installation Instructions: ACCENT SYSTEM

Installation Instructions: HYPERION R-Lite SYSTEM

Installation Instructions: ACCENT HIGH OUTPUT SYSTEM

INSTALLATION INSTRUCTIONS FOR PROPRIETARY VALANCE JDE#

PDX and PX Retrofit Series

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

WARNING. Tools: 1. Wire Strippers 2. Screw Driver or Rivet Gun 3. Tape Measure 4. Drill. Components: AWG (0.82mm) Wire-UL Approved

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation

OFFICE PARTITIONS. Data Port Openings. Use cable tie bracket to dress data cables under panels. STEP 1

Self-Testing Industrial Series

LAD6 6 LED Architectural Downlight

Luminaire PROFILE-SPOKE Ind. Up Dn Control (PS3-B) Type. Project. Notes. Performance Summary OPTIONS 4S D 76 W 3S D 57 W

LAD8 8 LED Architectural Downlight

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

LAD4 4 LED Architectural Downlight

RC-52 LED Conversion Kit

Outdoor Installation Using an Electronic LED Power Supply (TE-60L-12)

MODEL DESCRIPTION WATTS RATED LUMENS COLOR TEMP

Spectron Industrial Series

Assembly Instructions Retrofitting

Mizer Single Pump and Starter Box

2011 Cadillac CTS Coupe EGX Exhaust Tip & Rear Valance Mesh Accent Kit Part #: Complete E

3000 Watt Pneumatic Light Tower - Extends to 18 Feet - Three 1000W Metal Halide Lamps

D3 INSTALLATION GUIDE

Sky FactoryTM toll free

WARNING. Important Notice

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style (fluorescent replacement)

ASI Model 8374 Automatic Roll Towel Mechanism Owner s Manual

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

professional hardscape lighting solutions

Installation Instruction

Anthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

MOUNTING SYSTEMS SPECIFICATIONS

ChargePoint Gateway Installation Instructions

Luminaire PROFILE-SPOKE 15 UP 85 DN LED (PS1-D) Type. Notes. Performance Summary D OPTIONS 3S A 28 W B 34 W C 44 W D 57 W

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

Idaho Profile System - Trimless

SPACESAVER EC-300 A ELECTRICS

LED LINEAR AMBER 20L INSTALLATION GUIDE /01/16 VER. 1.0 CERTIFIED SAFETY US CA

Installation Instructions for Lingenfelter GM 2500 Suburban & Yukon XL Auxiliary Fan System (with ECM controlled fan output)

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

poollux Power plx-pw60 & plx-pw100

Control Panel Interface Upgrade Installation Guide For Model 200i and 250i Motorcycle Dynamometers Serial Number 202xxxx.

LED 2/3/4ft T8 Tube 120V

LED Recessed Troffer Retrofit Kit

DeSoto NEMA 4X EMERGENCY LIGHTING UNIT. U.S. Versions: 6V- DM90X618 / DM90X654 12V- DM90X1254 / DM90X12100 INSTALLATION INSTRUCTIONS


UL Listed TP408. KNOCKOUTS Cat. # Bracket Description Sides Bottom Unit Qty. Wt. Lbs. Per 100 TP408 Drawn 12 1 /2" 5 1 /2" 50 61

Idaho Profile System - Suspension

Universal Retrofit System Installation Instructions Revised:

DETEX Low Energy Automatic Door Operator AO19-1 Single Door - Push

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

LAD8R - Remodel 8 LED Architectural Downlight

Q-VAULT Installation Instructions. Q-Tran, Inc. Milford, CT

LAD6R - Remodel 6 LED Architectural Downlight

OLDSMOBILE CUTLASS

Target Hit Indicator. With Miss Detection. Instruction Manual

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

25W Explosion Proof LED Light VAC or 11-25V AC/DC - Pedestal Mount - 100' Cord w/ EPP Cap

Mustang CLASSIC LIGHT BAR INSTALLATION INSTRUCTIONS CDC #

LED IMPORTANT SAFETY INSTRUCTIONS

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

SAVE THESE INSTRUCTIONS

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

GENUINE PARTS INSTALLATION INSTRUCTIONS


Fixed Head Emergency Lights

IMPORTANT SAFETY INSTRUCTIONS

SloanLED LEDStripe Installation Guide SloanLED (888) 747-4LED

M-5230-V6 Mustang V6 Dual Exhaust Kit INSTRUCTION SHEET

Ultra Line ULTRA LINE FEATURES: ULTRA LINE ORDERS AND BOOTH LAYOUT DUE BY SEPTEMBER 28, 2018

Class I, Div. II Fluorescent Fixture - Emergency Battery Backup - Corrosion Resistant (Saltwater) -

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

A B C D E F. Tools Required (supplied by others)

Operating Instructions

Trackstar Motorized Folding Shade Installation Instructions

Explosion Proof Dock Light - Class I, Div. I, Groups C & D - 70 Watt LED Lamp - Extension Arm

STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

TOYOTA CAMRY LE / SE / XLE DUAL SEAT HEATER KIT Section I Pre-Installation Check

Hayes TrailTrac Kit Installation Guidelines Polaris Rush / Pro-R / Indy

Cetra. Ceiling Power Entry Installation (AEC1, AEC14, or AEC16)

Part No. PAFULAxxx. Figure 2

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

McDonalds Installation Guide

Inverting Fault Circuit Breaker Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives VAC and VAC

LCD4 4 LED Commercial Downlight

LCD8 8 LED Commercial Downlight

LCD6 6 LED Commercial Downlight

Product Installation Instruction LED Tube Lamp Retrofit Kits

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

GENUINE PARTS INSTALLATION INSTRUCTIONS

Passenger/Right Side Frame Bracket. Driver/Left Side Frame Bracket. (4) Spacer Washers. (2) Bull Bar Mounting Brackets

Lumination TM LED Luminaire LUR Series

New York City Approved. emergency lighting

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

ALL700RM-230V INSTALLATION INSTRUCTIONS

LED LINEAR INSTALLATION GUIDE RED 20L VER /13/

Transcription:

INSTALLATION INSTRUCTIONS FOR CHEVRON CANOPY: G2.1 RETROFIT LED LIGHTING Please review site plans before proceeding. Contact LSI Graphic Solutions Plus Customer Service at 1-(800) 678-2001 for installation support. Read through all of the instructions prior to beginning installation, and verify (using the packing list) that all parts have been received and are in good condition. JDE# 328180 INSTRUCTIONS: 5100233A SHEET 1 OF 6

The LSI G2.1 LED retrofit lighting is designed to replace fluorescent downlights in existing canopies with an "eyebrow" constructed with a cavity roughly 4" x 4" in a 14" deep x 8" tall overhang. See Figure A. Typically these canopies have a 30" blue fascia, although this may be extended to 36". Hood 14" Existing fluorescent fixture 4" 8" 8 1 2" 4 1 2" 1" Reflector 30" Typical FIGURE A ACM Step 1. Remove the fluorescent fixtures and reflectors. (NOTE: Do not remove the electrical service, as this can be used to provide power to the transformer for the LEDs.) The remaining cavity should be 4 1 2" deep from front to rear and 4" tall. This may vary up to an inch in depth from front to rear, but the height is critical for the correct bracket placement and illumination. If the height varies more than 1 2", please contact LSI Customer Service to discuss your application. In some applications, white flashing may be needed to close out the cavity after removing the fixtures. See Figure B. Hood 14" Remove fluorescent fixtures and reflectors - DO NOT REMOVE ELECTRICAL SERVICE 4"± 1 4" 8" 8 1 2" 4 1 2" (±1") 1" FIGURE B INSTRUCTIONS: 5100233B SHEET 2 OF 6

Step 2. Install LSI G2.1 support brackets in the cavity, with the 90 degree corner flush to the top outside corner of the cavity. These may be installed to aluminum or steel sheet metal using #12 x 3 4" Tek screws. These are not supplied, as different fasteners may be required depending on the substrate they are mounted to. The installer must provide fasteners based on the site conditions. See Figure C. Beginning at the left end, install a bracket every 36" on center. The LED tracks are 109" long. With a 1" overlap at the ends, the track can share a bracket where two meet. See Figure D. Hood 14" Fasteners not provided due to varying site substrates 4" 8" 3 1 2" FIGURE C 1 1 16" MOUNTING BRACKET (ENLARGED FOR CLARITY) 3 3 32" APX 35 1 2" 36" 36" LED Track FIGURE D INSTRUCTIONS: 5100233C SHEET 3 OF 6

Step 3. Install the LSI G2 60W power source assembly at the locations where electrical service is available. A transformer is required every 45 feet of LED, so additional circuits may be required, or conduit runs may be added to place the power sources where needed. Ideally, a power source should be placed at the left hand side of the cavity, and a transformer added every 45 feet. A licensed electrician must connect 120VAC 60hz power to the transformer in accordance with National Electric Code and local requirements. The transformers are rated at.63a input current, so up to 25 units can be run from a 20A circuit. These power sources are UL Recognized a Class 2 installation for damp location. The LSI G2 power source is provided with 5 feet liquid tight conduit and wires for connection. Proper grounding and sealing is the responsibility of the installer. The power source also includes a 3 foot jumper wire with connector to attach to the LED track once they are installed. See Figure E. FIGURE E LSI LED power supply 60W self contained APX 16" LSI LED power supply 60W self contained INSTRUCTIONS: 5100233D SHEET 4 OF 6

Step 4. Install the LED tracks on the lower point of the support brackets, with the LED towards the bottom. See Figure F. Use the #10 x 1 2" Tek screws provided. Be careful not to damage the LEDs or wiring while drilling in place. Each track should overlap 1" onto the next track, aligning the holes in the end of the track and sharing a support bracket. At the end of a run, the track can be cut to length to fit the available space. Trim between LEDs, and at each end if necessary for the best fit. Any cut wires should be capped with wire nuts. APX 35 1 2" 36" 36" LED Track #10 x 1 2" Tek screw Provided by LSI FIGURE F INSTRUCTIONS: 5100233E SHEET 5 OF 6

Step 5. Each track has a pair of jumper wires provided to connect from one end to the next. The LED circuit board has a tab marked positive and a tab marked negative. Push the spade connector on to the tap to connect positive to positive using the yellow wire and negative to negative using the black wire. At the beginning of a run, the jumper wires from the power source must be connected, yellow to positive and black to negative. A maximum of five 9 foot sections (45 feel total or 135 LED modules) can be connected to one power source. See Figure G. LED Track Yellow (Positive) Black (Negative) FIGURE G Step 6. The same LEDs and power supplies can be used for accent bands if white ends are installed on the canopies. Bullnose or flat fascia should be built by the installer's guidelines, and LSI brackets are used for the LED track in the upper front corner. Please contact LSI Customer Service to coordinate fit if LSI accent brackets are not used. Downlight and Accent LEDs can be run from the same power source, but additional wire leads will need to be ordered as custom to jump the corners. Mounting bracket optional by LSI or other structure within same parameters Canopy structure by others White ACM flat or radiused 32" high USLED ASSEMBLY BY LSI 8 " FIGURE H OVERALL CANOPY FASCIA HEIGHT 42" Blue ACM Accent band 8 degree slope INSTRUCTIONS: 5100233F SHEET 6 OF 6