Cell Ventilation Security Grille

Similar documents
Anti-Ligature Grille. There s a much bigger picture to be found at Ruskin Air Management. Model AL/35 Model AL/24. range available.

Linear Floor Grilles Models FG, F20, F25 and FRO

Panel Floor Grilles Model LDA, MDA, HDA, PFS and F48

Floor Swirls Models BZD and SZD

Fire Block and Pressed Steel Grilles

Fire Block and Pressed Steel Grilles

Linear Slot Diffusers Model Slot 20 and Model Slot 25

FlowBar High Capacity Slot Diffuser

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

Perforated Face Ceiling Diffusers

Blade Features. AirShield Control and Shut Off Dampers. AirShield

Catalogue. FlowBar. High Capacity Slot Diffuser.

SERIES GP. Security Grilles

NEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers

Series KSG 1. Security Grilles INDEX

SERIES GP GILBERTS. Security Grilles. Features

Incorporating V2.0. Product spec >>> > Series DD - Double deflection grilles

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

IrisControlDamper. For Adjustment and Measuring of Airflow.

TransShield Mode 1/2. Transfer Stainless Steel Sliding Plate Fire Dampers.

Grilles & Diffusers. Series NV Non-vision grilles. Incorporating. Sight blocking design ensures privacy is maintained

Incorporating V2.1. Product spec >>> > Series ECG - Egg crate grilles

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

Adjustable Curved Vane Diffusers. Vanes are parallel to the width dimension Vanes are parallel to the height dimension

Volume Control Dampers. Series LF upvc-vcd High performance plastic volume control dampers. Incorporating

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

SDV Vane Swirl Diffusers

Wall and Ceiling Grille

C O L M A N. Air Distribution SWIRL DIFFUSERS DWT SERIES DWT SERIES

Aircell Polymer Range

Ceiling swirl diffusers

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise

Volume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper

Small Format Circular Diffusers. Small format circular diffuse

SERIES C. Adjustable Deflection Grilles for Circular Ducting

SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130

DD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options.

DRUM JET DIFFUSERS. Available in Aluminium & Stainless Steel

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide

Air Distribution SWIRL DIFFUSERS DW SERIES SERIES

Ceiling swirl diffusers

C O L M A N. Air Distribution CIRCULAR DIFFUSERS LRS SERIES LRS SERIES

LINEAR SLOT DUFFUSERS

LINEAR SLOT DIFFUSERS

LINEAR BAR GRILLES. GRILLES-Linear Bar

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Louvre systems. Series WLD Weather louvre doors. Incorporating. Fully active louvre panel integrated into a door

Ceiling swirl diffusers with perforated face plate

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Diffusion grilles for installation in ducts

Ventilation grilles for installation into walls, sills or rectangular

PART F DIFFUSERS section 2 SEPT Publication. Air Diffusers. supply and exhaust ventilation systems. drum jet diffusers

CONTROL SMOKE AND BALANCING DAMPERS

HOTCHKISS AIR ACOUSTICS

Ceiling swirl diffusers with perforated face plate

HIGH CAPACITY LINEAR SLOT DUFFUSERS

C O L M A N. Air Distribution TRANSFER GRILLES G SERIES SERIES

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

DRUM JET DIFFUSERS TYPE: DJA DJB DJAP DJBP

Security Grilles. SG1 High Security Grilles SG2 Medium Security Grilles SG3 Low Security Grilles

Security Grilles. SG1 High Security Grilles SG2 Medium Security Grilles SG3 Low Security Grilles

Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

Air Transfer Grilles. NS Core only grille for beading in place. DV Core only door ventilator for bead fixing. NSNL Core only No-Sight

SERIES K GILBERTS. Fixed Blade Grilles. Features

series 90-GV Variable geometry units

Actionair Control and Shut Off Dampers

Linear Slot Diffusers Model Slot 20 & Model Slot 25

VAV/CAV BOXES COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

AJ52. Slim-line Sliding Door System with soft close mechanism

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide.

Hydropac. Waterside Control Fan Coil Units For Horizontal and Vertical Applications. June Hydropac. Features

Systempac. Fan Coil Unit / Acoustic Flex / Diffuser System Package. Systempac. January Features and Design Guide

Ventilation grilles for installation into walls, sills or rectangular

SERIES GZL. High Induction Linear Diffuser (Patented)

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects

SERIES JN GILBERTS. Jet Diffusers. Features PUBLICATION DIFFUSERS 8 JUNE 2007

Incorporating V2.0. Product spec >>> > Series NV - Non vision grilles

Air Transfer Grilles. NS Core only grille for beading in place. NSNL Core only No-Sight

SSV Smoke Shaft Ventilation System

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Extract-air grille with ATK plenum box

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

SERIES K. Fixed Blade Grilles

SERIES PG. Perforated Face

SERIES H. Heavy Duty Adjustable Deflection Grilles

BD Series. Backdraught Volume Regulating Damper M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

Transcription:

June 2010 Cell Ventilation Security Grille Cell Ventilation Security Grille Model CV Features Stainless Steel Construction Galvanised Steel/ PPC Construction Supply and Exhaust Tested "Fit For Purpose" High Security Installation Approved Design Grilles Diffusers Louvres Chilled Beams Ruskin Air Management Limited www.ruskinuk.co.uk

Contents Model CV Introduction Page 2 Dimensions Page 3-5 Selection Data Page 6 Ordering Information Page 7 Introduction The Model CV cell ventilation security grille has an inherent robust quality incorporated within its design to ensure compliance with the stringent requirements of both the Ministry of Justice Prison Service specification and Home Office Police Custody Design Guide. Model CV for use within high security cell ventilation applications has been independently tested by the Home Office at their own facility and has achieved their Fit For Purpose status. The Prison Service standard grille (Model ) is constructed from 2 main sections, a front plate and stub duct with a circular spigot connection. The front plate is manufactured in a single piece from 2mm thick 304 grade stainless steel (3mm thick galvanised steel and PPC optional) and having an active perforated area formed from 3mm diameter holes on 5mm centres. The stub duct section is manufactured from 2mm thick 304 grade stainless steel stitch welded to the front plate, (3mm thick galvanised steel and PPC optional) which together with the stainless steel clamping angle frame and recommended number of anchor bolts is suitable for a high security installation. The Police Service standard grille (Model ) is constructed from 2 main sections, a front plate and stub duct with circular spigot connection. The front plate section is manufactured in a single piece from 2mm thick 304 grade stainless steel, (3mm thick galvanised steel and PPC optional) having an active perforated area formed from 2mm diameter holes on 4mm centres. The stub duct section is manufactured from 2mm thick 304 grade stainless steel stitch welded to the front plate, (3mm thick galvanised steel and PPC optional), which together with the stainless steel clamping angle frame and recommended number of anchor bolts is suitable for a high security installation. Factory fitted accessories include an opposed blade damper, intumescent fire block, smoke/fire damper and fire damper assemblies. For alternative security applications the Model CV may be supplied as a front plate assembly only with countersunk holes in the flange for fixing with security screws (screws by others). The front plate is supplied as standard with a brushed stainless steel finish and the stub duct section is in self-finished stainless steel. (Optional galvanised steel and PPC finish). There are seven standard sizes available from a nominal size of 150 x 150 to 300 x 300mm, each size is normally supplied with a circular detachable spigot connection, but can be supplied without the circular connection if required. Other sizes are available on request. 2 www.air-diffusion.co.uk

Dimensions / Configurations / Options Configuration 0 - Front Grille Only WALL THICKNESS SECURITY SCREWS BY OTHERS OPENING = NOMINAL SIZE + 20mm OR 6MM CSK HOLE TO SUIT SECURITY SCREWS Configuration 1 - Front Grille / Stub Duct WALL THICKNESS SECURITY SCREWS BY OTHERS OPENING = NOMINAL SIZE + 20mm OR 6MM CSK HOLE TO SUIT SECURITY SCREWS www.air-diffusion.co.uk 3

Dimensions / Configurations / Options Configuration 2 - Front Grille / Stub Duct / Clamping Frame / Circular Spigot Connection WALL THICKNESS 50 65 =NOMINAL +100mm. MIN. WALL OPENING = NOMINAL +55mm. SPIGOT DIA 75 OR 75 50 ANGLE CLAMPING FRAME 75 x 50 x 3 (TYPICAL) Configuration 2 Option 4: Front Grille / Stub Duct / Fire / Smoke Damper / Clamping Frame / Circular Spigot Connection WALL THICKNESS 201 65 MIN. WALL OPENING = NOMINAL +55mm. INDEPENDENT DAMPER SUPPORT BY OTHERS SPIGOT DIA. FIRE / SMOKE DAMPER WITH ETR SMOKE DAMPER WITHOUT ETR FOAM SEAL ON ALL 4 SIDES OF THE STUB DUCT = NOMINAL +100mm. ANGLE CLAMPING FRAME 4 www.air-diffusion.co.uk

Dimensions / Configurations / Options Configuration 2 Option 6: Front Grille / Stub Duct / Removable Lockable Damper / Clamping Frame / Circular Spigot Connection WALL THICKNESS 50 65 REMOVABLE/ LOCKABLE OPPOSED BLADE DAMPER 75 MIN. WALL OPENING = NOMINAL +55mm. SPIGOT DIA 75 50 ANGLE CLAMPING FRAME 75 X 50 x 3mm. (TYPICAL) www.air-diffusion.co.uk 5

Selection Data Model - 3mm holes on 5mm centres - Maximum Air Flow Rates, Complete Assembly, Stub Duct and Spigot Nominal Grille Size Nom Spigot Size 150 x 150 125dia. Air Volume (l/s) 10 17 20 30 35 40 45 50 ThrowLT (m) 1.2 2 3.3 4.1 4.4 4.5 5 5.3 Pressure Drop - (Pa) 1.25 2.2 6 11.5 15 21 24 28 Sound level - NRlw <10 <10 <15 20 22 24 26 28 200 x 150 125dia. Air Volume (l/s) 15 20 35 45 50 60 70 80 ThrowLT (m) 1.5 2.5 4.4 5.2 5.5 6.0 6.4 7.0 Pressure Drop - (Pa) 1 1.76 4.8 9.2 12 16.8 19.2 22.4 Sound level - NRlw <10 <10 17 24 26 28 31 34 250 x 150 125dia. Air Volume (l/s) 18 28 40 50 60 70 80 90 ThrowLT (m) 1.1 2.3 4.1 5.1 5.5 5.6 6.3 6.6 Pressure Drop - (Pa) 0.8 1.6 4.0 6.1 9.0 13.0 15.0 17.7 Sound level - NRlw <10 <10 16 22 24 27 29 33 200 x 200 160dia. Air Volume (l/s) 30 40 55 65 75 85 95 ThrowLT (m) 2.0 2.6 3.5 4.0 4.7 5.4 5.8 Pressure Drop - (Pa) 1.6 5.0 10.0 15.0 22.0 25.0 28.0 Sound level - NRlw <10 17 26 28 31 35 38 250 x 200 160dia. Air Volume (l/s) 25 40 50 60 75 90 100 110 ThrowLT (m) 0.8 2.0 2.5 3.0 4.0 4.7 5.4 5.8 Pressure Drop - (Pa) 1.0 4.0 6.0 8.0 13.0 19.0 23.0 26.0 Sound level - NRlw <15 <20 20.0 25.0 30.0 33.0 37.0 40.0 250 x 250 200dia. Air Volume (l/s) 30 50 60 80 90 110 130 140 ThrowLT (m) 0.8 2.1 2.5 3.0 4.0 4.7 5.4 5.8 Pressure Drop - (Pa) 1.0 2.5 4.0 6.0 8.0 13.0 18.0 24.0 Sound level - NRlw <15 <20 19.0 23.0 26.0 30.0 36.0 42.0 300 x 300 250dia. Air Volume (l/s) 45 70 90 110 135 160 180 200 ThrowLT (m) 2.6 4.0 5.0 6.0 8.0 8.5 11.0 >12 Pressure Drop - (Pa) 1.2 3.0 4.0 7.6 12.0 15.0 22.0 30.0 Sound level - NRlw 19 22.0 19.0 23.0 35.0 37.0 40.0 >40 Model - 2mm holes on 4mm centres - Maximum Air Flow Rates, Complete Assembly, Stub Duct and Spigot Nominal Grille Size Nom Spigot Size 150 x 150 125dia. Air Volume (l/s) 10 17 20 30 35 40 45 50 ThrowLT (m) 1.3 2.2 3.6 4.5 4.8 5.0 5.5 5.8 Pressure Drop - (Pa) 1.5 2.7 7.3 14.0 17.1 23.9 27.4 31.9 Sound level - NRlw <10 <10 <15 22 24.0 26.0 28.0 30.0 200 x 150 125dia. Air Volume (l/s) 15 20 35 45 50 60 70 80 ThrowLT (m) 1.5 2.5 4.4 5.2 5.5 6.0 6.4 7.0 Pressure Drop - (Pa) 1.1 2.0 5.5 10.5 12 16.8 19.2 22.4 Sound level - NRlw <10 <10 19.0 26.0 28.0 30.0 33.0 36.0 250 x 150 125dia. Air Volume (l/s) 18 28 40 50 60 70 80 90 ThrowLT (m) 1.2 2.5 4.5 5.6 7.4 7.5 8.4 8.9 Pressure Drop - (Pa) 0.8 1.6 4.0 6.1 10.3 14.8 17.1 20.1 Sound level - NRlw <10 <10 18.0 24.0 26.0 29.0 31.0 35.0 200 x 200 160dia. Air Volume (l/s) 30 40 55 65 75 85 95 ThrowLT (m) 2.4 3.2 4.3 4.0 4.7 5.4 5.8 Pressure Drop - (Pa) 1.8 5.7 11.4 15.0 22.0 25.0 28.0 Sound level - NRlw <10 18.0 27.0 29.0 32.0 36.0 39.0 250 x 200 160dia. Air Volume (l/s) 25 40 50 60 75 90 100 110 ThrowLT (m) 0.9 2.2 2.8 3.3 4.4 5.2 5.9 6.4 Pressure Drop - (Pa) 1.0 4.0 6.0 8.0 18.1 26.4 32.0 36.2 Sound level - NRlw <15 <20 21.0 26.0 31.0 34.0 38.0 41.0 250 x 250 200dia. Air Volume (l/s) 30 50 60 80 90 110 130 140 ThrowLT (m) 0.9 2.3 2.8 3.3 4.4 5.2 5.9 6.4 Pressure Drop - (Pa) 1.4 3.5 5.6 8.3 8.0 13.0 18.0 24.0 Sound level - NRlw <15 <20 20.0 24.0 27.0 31.0 37.0 43.0 300 x 300 250dia. Air Volume (l/s) 45 70 90 110 135 160 180 200 ThrowLT (m) 2.9 4.4 5.5 6.6 8.8 9.4 12.1 >13 Pressure Drop - (Pa) 1.2 3.0 4.0 7.6 16.7 20.9 30.6 41.7 Sound level - NRlw 21.0 24.0 21.0 25.0 37.0 39.0 42.0 >43 The selection data is based on the following parameters:- Grille mounting height 2.8m. Throw distances are based on isothermal conditions and a terminal velocity (Vt) of 0.5m/s. No room absorption correction factors were considered for the acoustic results. For grille sizes greater than 300 x 300 please consult our sales office. 6 www.air-diffusion.co.uk

Ordering Information Example Model Type Stub Duct Fixing Accessory Nominal Size (WxH) Nominal Spigot Size* Finish G 2 0 2 250 x 250 200Ø 56 (Ministry of Justice - Prison Service) (Home Office - Police Service) 0 Front Grille Only 1 With Stub Duct 2 With Stub Duct, Anchor Bolts and Angle Clamping Frame Note: Wall thickness to be advised to ensure correct stub duct depth. Nominal Size Nominal Spigot (W x H) Size 150 x 150 125 Ø 200 x 150 125 Ø 250 x 150 125 Ø 200 x 200 160 Ø 250 x 200 160 Ø 250 x 250 200 Ø 300 x 300 250 Ø (Standard Sizes shown, Other Sizes available on Request) 56 - Brushed Stainless Steel 83 - White PPC to RAL 9010 (20% Gloss) (Other finishes only available on Special Request) 0 No Front Fixing 1 Countersunk Screw Holes *Includes quick release spigot as standard fitting with rear mounted damper. G No OBD R With OBD 0 No Accessories 1 Intumescent Fire Block (1 hour rating) 2 Circular Spigot Connection 3 Intumescent Fire Block (1 hour rating and Circular Spigot Connection. 4 Fire / Smoke Damper (with ETR)** 5 Smoke Damper (without ETR)** 6 Removable / Lockable Opposed Blade Damper Assembly - Rear Access 7 Face Operated Opposed Blade Damper Assembly **Refer to Technical Sales for this configuration. Important Note: All orders must be addressed to Air Diffusion, Ruskin Air Management Limited. www.air-diffusion.co.uk 7

Ruskin Air Management Limited is a BS EN ISO 9000 registered company. The statements made in this brochure or by our representatives in consequence of any enquiries arising out of this document are given for information purposes only. They are not intended to have any legal effect and the company is not to be regarded as bound thereby. The company will only accept obligations which are expressly negotiated for and agreed and incorporated into a written agreement made with its customers. Due to a policy of continuous product development the specification and details contained herein are subject to alteration without prior notice. Comprehensive and detailed information is available for all Air Diffusion products. Visit our website at www.air-diffusion.co.uk Ruskin Air Management Limited Stourbridge Road, Bridgnorth, Shropshire, WV15 5BB England. Tel: 01746 761921 Fax: 01746 760127 Email: sales@air-diffusion.co.uk Website: www.air-diffusion.co.uk