Report Number: G CRT-001A Model Number: Ionflow 50 Surface ARB Number: 1334

Similar documents
CX6850 CAT 6A PREMIUM+ UTP SYSTEM

CX5000 CAT 5e UTP System

CS6700 CAT 6A SHIELDED SYSTEM

CX6150 CAT 6 Enhanced UTP System

Test Report For: EMECO INDUSTRIES INC Bar Stool

EESTOR INC. TEST REPORT

Test Report Number: G CRT-039f

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: Sept 27, 2013 REVISED DATE: NA

TEST REPORT INTERTEK TESTING SERVICES NA, INC Arlingate Lane Columbus, OH, 43228

Test Summary Report for the Solid Wind Power SWP25-14TG20 Small Wind Turbine

Certified Automotive Parts Association. Vehicle Test Fit Report. Report Number: HN-04060BBQ/COM VTF CAR Refit/ Tong Yang Industry Co.

PRODUCT EVALUATION REPORT

This is a new permit condition titled, "2D.1111 Subpart ZZZZ, Part 63 (Existing Non-Emergency nonblack start CI > 500 brake HP)"

Verification/Report Number(s): HEARTWAY MEDICAL PRODUCTS Co., Ltd. Applicant Name/Address:

TIER 3 MOTOR VEHICLE FUEL STANDARDS FOR DENATURED FUEL ETHANOL

Standard Diesel & FCC Additive Technical Analysis on Lubricity

No , Vers.1

Report issued by: AUTHORISED FOR ISSUE:. Caroline Blenkhorn Section Head Appliances Department

REPORT NO INSPECTION, TEST AND EVALUATION OF. Interlock Kits SUBMITTED TO MASTER ELECTRICAL SERVICES 3107 LANVALE AVENUE RICHMOND, VA 23230

Report of Inspection

UL TEST REPORT AND PROCEDURE

SFI SPECIFICATION 1.2 EFFECTIVE: FEBRUARY 9, 2006* PRODUCT: Multiple Disc Clutch Assemblies for Vehicles with Naturally Aspirated Engines

The Scala Ladder System Leaning Ladders - Sliding Ladders - Hook-on Ladders 7.1

FEBRRUARY 22, 2008 TEST REPORT # QSH/QTH/QTE SERIES CONNECTOR SHEAR TESTING SAMTEC, INC.

TEST REPORT UL Fire test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces

IAQ-CALC TM Indoor Air Quality Meter

3.1 Air Pollution Control Officer (APCO): as defined in Rule 1020 (Definitions).

SFI SPECIFICATION 1.1 EFFECTIVE: NOVEMBER 9, 2001 *

RULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006)

2. provide data indicating what types and sizes of particles are not removed by used PHEAF devices, and

600 Amp Surge Arrester

WORKSHOP REPORT. No, the RICE NESHAP applies only to stationary engines as defined in 40 CFR

Please Refer to Attached Sample Form

Indoor Air Quality Meter

Intertek Test Report No CRT-005a Project No. G

E/ECE/324/Rev.2/Add.102/Rev.1 E/ECE/TRANS/505/Rev.2/Add.102/Rev.1

NATIONAL TECHNICAL SYSTEMS

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PVC Guardrail System Utilizing New Nylon/PVC Rail Mounting Bracket

NATIONAL TECHNICAL SYSTEMS

IAQ-CALC TM Indoor Air Quality Meter

Instructions for Completing Oncor s Interconnection Application For Solar PV Projects

Modification Record of Product Specification

VOLUNTARY CODE OF PRACTICE FOR ELECTROMAGNETIC COMPATIBILITY (EMC) OF MOTOR VEHICLES (13 October 2014)

Permit Holder. Permitted Equipment

Test Report Gonio-Photometry R V1

THE CONNECTICUT LIGHT AND POWER COMPANY dba EVERSOURCE ENERGY AND THE UNITED ILLUMINATING COMPANY

Performance Rating of Residential Air Filter Equipment

N , Vers. 0

SAFETY COMPLIANCE TESTING FOR FMVSS NO. 104 WINDSHIELD WIPING AND WASHING SYSTEMS

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

SFI SPECIFICATION 1.3 EFFECTIVE: MAY 23, 2000 * PRODUCT: Nitro-Methane Drag Race Multiple Disc Clutch Assemblies

SAFETY COMPLIANCE TESTING FOR FMVSS NO. 104 WINDSHIELD WIPING AND WASHING SYSTEMS

CREEP PERFORMANCE TEST REPORT. Rendered to: TREX COMPANY LLC. Seclusions Composite Privacy Fence System TYPE: Composite Fence System

Prüffeld der Schaltwerke

Performance Rating of Residential Air Filter Equipment

Interconnection Process for Generation Systems

Rider : NET METERING SERVICE AND ELECTRICAL SYSTEM INTEGRATION

Code Compliance Research Report CCRR-0258

ARCONIC ARCHITECTURAL PRODUCTS FIRE TEST REPORT

ISO INTERNATIONAL STANDARD

Sliding Door Systems 8.1

Hybex Microsample Incubator

INTERNATIONAL MARITIME ORGANIZATION (IMO) Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance

ANNEX 3. RESOLUTION MEPC.278(70) (Adopted on 28 October 2016)

BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA

WP2 - CFD Private Network Meter Commissioning, Proving and Calibration Tests

SFI SPECIFICATION 18.1 EFFECTIVE: JUNE 17, 1999 *

Agenda. Introduction to IEC Differences between the 1 st and 2 nd edition. How will these changes impact the industry?

SFI SPECIFICATION 4.2 EFFECTIVE: OCTOBER 26, 1994*

Drive System Application

RECHARGEABLE LITHIUM-ION BATTERIES FOR SYSTEMS

Compatibility Between Electric Trains and Electrification Systems

Technical Committee Motor Vehicles 15 September RDE 3 discussion

Test Report. for. Chilicon Power 1563 Calle Patricia Pacific Palisades, CA USA. Project Number: G Prepared By:

Report Issued: October 19, 2014 Project No.: 23942

UPDATE OF THE SURVEY OF SULFUR LEVELS IN COMMERCIAL JET FUEL. Final Report. November 2012

SFI SPECIFICATION 32.1 EFFECTIVE: MARCH 24, 2009 *

SGS North America, Inc.: Grant of Expansion of Recognition. AGENCY: Occupational Safety and Health Administration (OSHA), Labor.

Permit Holder. Permitted Equipment

Decision D ATCO Electric Ltd. Decommissioning of Transmission Line 6L82

IMO fuel oil consumption data collection system

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES CLP S-D-A FTSH S-DV-A SAMTEC, INC.

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES SEM H-D-WT TEM H-D-WT SAMTEC, INC.

ENVIRONMENTAL & ENGINEERING SERVICES DEPARTMENT

SFI SPECIFICATION 34.1 EFFECTIVE: January 13, 2017*

Electrostatic Fieldmeter

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Adelaide Wind Power Project Turbine T05 (AD117) IEC Edition 3.0 Measurement Report

NovitaTech Engineering

Australian Standard. Pneumatic fluid power General requirements for systems (ISO 4414:1998, MOD) AS AS 2788

REPORT NO. TR-P NC SAFETY COMPLIANCE TESTING FOR FMVSS 223 REAR IMPACT GUARDS 2007 TRANSFREIGHT TECHNOLOGY NHTSA NO.

Microgeneration Installation Standard: MCS

1 st Quarter Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations. Prepared for:

Louisville Gas and Electric Company

Comparison of IG Testing Standard. IGMA Summer Meeting August 8, 2004

BIM-17-2 Bus Interface Module for compass and outside temperature

UNITED STATES ENVIRONMENTAL PROTECTION AGENCY OFFICE OF TRANSPORTATION AND AIR QUALITY ENGINE INTERNATIONAL AIR POLLUTION PREVENTION CERTIFICATE

Eliminate Coil Wire Breakage on Passive Anti-Theft System (PATS)

Long Combination Vehicle (LCV) Exemption Permit Application

Transcription:

3933 US Route 11 Cortland, NY 13045 Telephone: +01 607 753 6711 Facsimile: +01 607 756 9891 www.intertek-etlsemko.com Order No. G100222377 28 January 2011 Revised 11 November 2011 Report Number: G100222377CRT-001A Model Number: Ionflow 50 Surface ARB Number: 1334 RENDERED TO: Mr. Ragne Svadil LightAir Holding AB Box 6049,171 06 Solna, SE Sweden Ph: +46 709615112 Report Scope: Limitation Statement: Authorization: Ozone Emissions Testing of Household Electrostatic Air Cleaners. The test data and results contained in this report are provided for client information and evaluation. No conclusions are drawn by Intertek. The tests were authorized by signed quote # 500250616, dated 8/6/2010. Standard Used: UL Standard for Safety for Electrostatic Air Cleaners, UL 867, Section 37 Fourth Edition, December 21, 2007. - Std. 867 Certification Requirement Decision, Section/Paragraph 37.2.2 a) 2), Ozone Test Chamber Air tightness - Std. 867 Certification Requirement Decision, Section/Paragraph 37.4.8 & 37A.5, Ozone Test Test Conditions. - Std. 867 Certification Requirement Decision, Section/Paragraph 37A.1, Peak Ozone Determination Test Room Dimensions. - Std. 867 Certification Requirement Decision, Section/Paragraph 37.4.6, Definition of Steady-State Hours 7-8. - Std. 867 Certification Requirement Decision, Section/Paragraph 37.2.3, Chamber Setup. - Std. 867 Certification Requirement Decision, Section/Paragraph 3.3A, 3.9A, 3.11A, 37.4.6A, 37.4.7, 37.4.8, 37A.5, 37A.4, 37.5A, 37A.5, 37A.5B, 37.4.1. Filter Test Iterations. Report Content: 1. Unit Under Test 2. Peak Ozone Test Results 3. Max Ozone Test Results 4. Chamber Equipment 5. Summary/Signatures 6. Appendix Page 1 of 10 This report is for the exclusive use of Intertek s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek s responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only the sample tested. This report by itself does not imply that the material, product or service is or has ever been under an Intertek certification program.

1. Unit Under Test Information MODEL Manufacturer: LightAir Holding AB Pre-Filter: No Model Number: Ionflow 50 Surface HEPA Filter: No Charged Particle REM Collector: Settings: 1 Carbon Filter: No O3/Voltage Settings: - UV Light: No O3 Monitor: - Ionizer: Yes Model Notes: New PCB Device has only 1 setting on/off LED lit when device is ON FIRST SAMPLE Control Number: 212285.01 Run-in Start: 16:30 8/6/2010 Serial Number: N/A Run-in End: 9.00 8/9/2010 Manufacture Date: N/A Run-in Temperature: 77 ± 4 degf Receive Date: 8/5/2010 Received Status: OK Sample Notes: SECOND SAMPLE Control Number: 212285.02 Run-in Start: N/A Serial Number: N/A Run-in End: N/A Manufacture Date: N/A Run-in Temperature: N/A Receive Date: 8/5/2010 Received Status: OK Sample Notes: Page 2 of 10

2. Peak Ozone Test Results GRILL AND AIR PERIPHERY DIMENSIONS Date of Test: 10/9/2010 Grill Diameter: N/A Air Periphery Diameter: N/A Estimated Grill Area: N/A Est. Air Periphery Area: N/A Notes: Device contains 3 Ionizers that are on the top of the device. The sampling probe was positioned at each one of the ionizers. The Ionizers are in the open and therefore there is no grill and no air periphery. Device has a removable charged aluminum particle collector. PEAK LOCATIONS Loc. X Y - [inches] [inches] 1 0 0.75 2 0 0.0 3 0-0.75 * Location measurements are coordinates in reference to the center point. Page 3 of 10

PEAK OZONE CONCENTRATIONS Location With Filter(s) Without Filter(s) ON ON High Low High Low 1 0.0008 0.0029 2 0.0011 0.0074 3 0.0027 0.0071 4 5 6 7 8 9 10 11 12 13 14 15 Notes: - Ozone Concentrations less background level; in units of PPM. - Peak concentration for each iteration is in BOLD. Page 4 of 10

3. Max Ozone Test Results Date of Test: 11/10/2010 Sample: 1 of 2 Setting: ON Filter(s): Charged particle collector removed, ionizer on 0.0070 8 Hour Ozone Concentration Ozone Concentration (ppm) 0.0060 0.0050 0.0040 0.0030 0.0020 0.0010 0.0000 0 1 2 3 4 5 6 7 8 Time (Hours) MAXIMUM OZONE TEST RESULTS UL Ref. Pass/Fail Mean Min Max Delta Units Background C(t) O3: 37.4.3 PASS 0.000 0.000 0.000 0.000 [ppm] Test 1min C(t) O3: 37.1.2 PASS 0.001 0.000 0.006 0.006 [ppm] Test 5min C(t) O3: 37.1.2 PASS 0.001 0.000 0.004 0.004 [ppm] Chamber Temperature: 37.4.2 PASS 77 77 77 1 [degf] Chamber Humidity: 37.4.2 PASS 50 49 51 1 [%RH] Chamber Static Pressure: - PASS 0.02 0.02 0.02 0.01 ["H2O] Chamber Supply Air Flow: - - 20 20 20 0 [SCFM] Required to Test 2nd Sample: 37.1.1 NO Test Duration: *37.4.6 8 hours Notes: Page 5 of 10

Date of Test: 11/11/2010 Sample: 1 of 2 Setting: ON Filter(s): Charged particle collector installed, ionizer on 0.0070 24 Hour Ozone Concentration Ozone Concentration (ppm) 0.0060 0.0050 0.0040 0.0030 0.0020 0.0010 0.0000 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Time (Hours) MAXIMUM OZONE TEST RESULTS UL Ref. Pass/Fail Mean Min Max Delta Units Background C(t) O3: 37.4.3 PASS 0.000 0.000 0.000 0.000 [ppm] Test 1min C(t) O3: 37.1.2 PASS 0.001 0.000 0.007 0.007 [ppm] Test 5min C(t) O3: 37.1.2 PASS 0.001 0.000 0.006 0.006 [ppm] Chamber Temperature: 37.4.2 PASS 77 76 78 1 [degf] Chamber Humidity: 37.4.2 PASS 50 49 51 1 [%RH] Chamber Static Pressure: - PASS 0.02 0.01 0.03 0.01 ["H2O] Chamber Supply Air Flow: - - 20 20 20 0 [SCFM] Required to Test 2nd Sample: 37.1.1 NO Test Duration: *37.4.6 24 hours Notes: Page 6 of 10

4. Chamber Equipment Information Test Equipment List Instrument Model Intertek Ctrl # Cal Due Date Teledyne Advanced Pollution Instrumentation Ozone Calibrator Teledyne Advanced Pollution Instrumentation Ozone Monitor Teledyne Advanced Pollution Instrumentation Ozone Monitor 703E O200 1-5-2011 400E O201 * 400E O202 * Vaisala Temperature & Humidity Transducer HMD-70Y T1307 04-09-11 Dwyer Airflow Anemometer 471 Y202 07-21-11 * The 400E Ozone Monitor is calibrated using the 703E calibrator. Page 7 of 10

5. Summary/Signatures The test sample(s) documented in this report were tested in accordance to the standard(s) and Certification Requirement Decision(s) (CRDs) referenced in the first page of this report. The representative sample(s) have been tested, investigated, and found to comply with the requirements of the UL Standard 867 Section 37.1.2 criteria of emitting a maximum ozone concentration of less than 0.050 ppm. Furthermore a second sample was not required to be tested as the first sample s maximum emissions were less than 0.030 ppm to satisfy the exception in the Section 37.1.1. This testing was conducted as part of the California Air Resources Board Certification program and is referenced with ARB Application No. 1334 This report completes our evaluation covered by Intertek Project No. G100222377CRT-001A. If there are any questions regarding the results contained in this report, or any of the other services offered by Intertek, please do not hesitate to contact the undersigned. Please note; this Report does not represent authorization for the use of any Intertek certification marks. OZONE EMISSIONS SUMMARY Setting Filter(s) O3/Voltage Setting C(t) max [ppm] ON NO - 0.006 ON YES - 0.007 Completed Phil Armstrong Eric Dunay by: Reviewed by: Title: Associate Engineer Title: Engineer Signature: Signature Date 11 November 2011 Date: 11 November 2011 Page 8 of 10

6. Appendix DATA FILES Test Name Model Half Life Max Ozone: ON w/o Filter Max Ozone: ON w/ Filter Raw Data File 745_Halflife_ozonelog.csv 746_ONNF_ozonelog.csv 747_ONWF_ozonelog.csv ATTACHMENT DOCUMENTS Document Soft-copy File Name ARB Application 1334 Chain of Custody: Sample 1 COC_212285.01.pdf Chain of Custody: Sample 2 COC_212285.02.pdf UUT PHOTOGRAPHS No Nameplate UUT Nameplate Page 9 of 10

UUT PHOTOGRAPHS: PEAK TEST ON w/ charged particle collector installed ON w/ charged particle collector removed UUT PHOTOGRAPHS: MAX OZONE TEST ON w/ charged particle collector installed ON w/ charged particle collector removed Page 10 of 10