: 660 N. For material handling and clamping of small workpieces. CKZT25 -X2797 (Base Type) Power Clamp Cylinder INFORMATION. ø

For material handling and clamping of small workpieces

Pin Shift Cylinder. High Precision. Position Reproducibility CKQ G-X2370. Deflection ±0.1 mm or less INFORMATION. For High Precision Positioning

Precision Cylinder. MTS Series. ø8, ø12, ø16, ø20, ø25, ø32, ø40 MXH MXS MXQ MXQ MXF MXW MXJ MXP MXY MTS D- -X. Series Variations MTS8

Miniature Guide Rod Cylinder ±0.1. Mounting from 2 directions

Specifications MHC2-10D MHC2-16D MHC2-20D MHC2-25D MHC2-10S. Double acting MHC2-16S. Single acting MHC2-20S MHC2-25S. Angular style air gripper

How to Order. Lead wire length Nil L Z M9N L. Type of auto switch for detecting rotation. Nil Without auto switch. Applicable Auto Switch

Compact Slide. Series MXH ø6, ø10, ø16, ø20

How to Order M9BW. Action. Double acting Single acting. Load voltage Electrical entry direction M9NWV M9NW 12 V 5 V, M9BWV M9BW 12 V 12 V

NAAMS Standards Compliant Power Clamp Cylinder ø50, ø63

Mini Free Mount Cylinder

Centering Unit. Alignment and positioning of transferred workpieces. MACM Series P-E16-22A. ±1 mm or less

Series CYP. ø15, ø32 Clean Rodless Cylinder. How to Order

Parallel Style Air Gripper: Wide Type

Power Clamp Cylinder

Series C95N. ISO/VDMA Cylinder: With Lock Type Double Acting, Single Rod. ø32, ø40, ø50, ø63, ø80, ø100. How to Order

240% 19% reduced. Compact Slide. MXH Series. Improved by up to. With new high rigidity linear guide. 369g. ø6, ø10, ø16, ø g.

180 Angular Style Air Gripper

Doc. no.ck1*-om0066p. PRODUCT NAME Clamp Cylinder. MODEL / Series / Product Number

Angular Style Air Gripper

Free Mount Cylinder. Series. Series CU CAT.EUS20-95 B -UK. Space-saving. Auto Switch Capable P. 4, 23, 37 P. 45 P. 43

Rotary Actuator. New RoHS. New. Vane Type 10, 15, 20, 30, 40. Many combinations available! Series CRB 2. Standard type/series CRB2

Guide Table. ø40, ø63, ø100

Guide Table. MGF Series

CAT.ES20-53 E. Dual-Rod Cylinder. Series CXS. CXS Dual-Rod Cylinder with Air Cushion Compact Type Series CXSJ. New:

Slide Unit. CX2/CXWM/CXWL Series. Slide Bearing/CX2:ø10, ø15, ø25 CXWM:ø10, ø16, ø20, ø25, ø32 Ball Bushing Bearing/CXWL:ø10, ø16, ø20, ø25, ø32

ø20, ø32 ø50, ø63, ø80 How to Order Piping direction Flange side Nil Cylinder stroke 15mm 15 (RSH20) 20mm 20 (RSH32) 30 D L Cylinder stroke

Miniature Regulator. Standard Specifications. Model IN side OUT side (Applicable tubing O.D.) Proof pressure Maximum operating pressure

Rotary Table/Vane Style

Free Mount Cylinder for Vacuum

Slide Unit. Bore size. ø15 (2) ø10 (2) ø16 (3) ø20 (2) Ball bushing bearing Slide bearing. ø25 (3) (3) ø32 (3)

Series CYP. Clean rodless cylinder ø15, ø32. How to Order

Free Mount Cylinder. Series CU. A space-saving air cylinder with multiple surfaces capable of mounting directly. Offered in rich variations.

Toggle Type Air Gripper

Series MSU. Rotary Table Vane Style. High Precision. Size: 1, 3, 7, 20 CRB2 CRBU2 CRB1 MSU CRJ CRA1 CRQ2 MSQ MRQ D mm or less.

Low Profile Air Gripper. Series MHF2. Low profile air gripper with space-saving design is newly released. 5-77

Wedge Cam Operation Slide Guide. Air Gripper/2-Finger Type ø12, ø16, ø20, ø25. Option: Stainless steel

Series CRB2. Rotary Actuator Vane Style. Size: 10, 15, 20, 30, 40 CRB2 CRBU2 CRB1 MSU CRJ CRA1 CRQ2 MSQ MRQ D- 20- Series Variations.

Added 100 mm and 150 mm lengths. Actuators 10% Air leakage 20% Air blow 70% Current model

MHR3/MDHR3 Series. Rotary Actuated Air Gripper/3-Finger Type. Size: 10, 15 MDHR 3 10 R M9N S. How to Order. Without auto switch

Flame hardening steel. The height from the reference hole to the surface of the reference support block can be selected from 2 types HIGH or LOW.

Miniature Regulator Series ARJ310

CAT.ES20-53 E -UK. Dual-Rod Cylinder. Series CXS. CXS Dual-Rod Cylinder with Air Cushion Compact Type Series CXSJ. New:

Rotary Table/Vane Style

CAT.ES Pin Clamp Cylinder. Positioning and clamping at one time! Construction. Guide pin. Clamp arm (When unclamped) 10 mm.

Rotary Actuated Air Gripper

GTO Precise, universal stationary chuck for collets

Series MGPS. Compact Guide Cylinder: ø50, ø80 MGP S Z73. How to Order. Applicable auto switches. Compact Guide Cylinder.

/ ø6, ø10, ø16, ø20 A table cylinder suitable for short pitch mounting

Rotary Actuator/Vane Type

CAT.ES20-53 E -UK. Dual-Rod Cylinder. Series CXS. CXS Dual-Rod Cylinder with Air Cushion Compact Type Series CXSJ. New:

Heavy Duty Stopper Cylinder

Wide Type Parallel Style Air Gripper

Standard Specifications. Model IN side OUT side Fluid Proof pressure Maximum operating pressure

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Compact Type Dual-Rod Cylinder

49.5 mm Overall. 30 mm MXZ ø20. Compact. Compact Cylinder with Linear Guide. MXZ Series CAT.ES20-236A. ø12, ø16, ø20, ø25. MXZ ø20, 10 mm stroke.

69% 30.5 mm 16 mm. Compact Guide Cylinder. Compact. lighter 0.32 kga0.1 kg (Compared with the current MGP-Z series, ø16, 10 mm stroke) Weight

Guide Table. Series MGF

Standard Specifications

Low Profile Air Gripper

Pneumatic Power Clamps

Electric Actuator/Slider Type Motor Parallel Type

Dual rod cylinder with guide function suitable for pick & place applications. Adjustable stroke range: 0 to 5 mm. Axial foot piping.

LAll types with lock OHolds a workpiece during emergency stops.

Low Profile Air Gripper

Speed Controller with One-touch Fitting AS13 1F-M3 AS13 1F-M5. Specifications

Check Valve Series AK How to Order

Compact Rotary Actuator

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

240 g. 290 g. Compact and lightweight. Electric Actuators. LEPY/LEPS Series. Miniature Rod Type/Miniature Slide Table Type

240 g. 290 g. Electric Actuators Series LEPY/LEPS. Miniature Rod Type/Miniature Slide Table Type

Series MHK2. Wedge Cam Operation Slide Guide Air Gripper (2 Finger)

Manifold Regulator Modular Type. Regulator for manifold. Body size. Number of stations stations. 10 stations. Standard Specifications

Position locking clamp cylinder. UCAC2 Series. Bore size: ø50, ø63. Double acting single rod type

Air Cylinder: Standard Type Double Acting, Double Rod. ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100. How to Order. Bore size

240 g. 290 g. Compact and lightweight. Electric Actuators. Series LEPY/LEPS. Miniature Rod Type/Miniature Slide Table Type

Parallel Style Air Gripper

CM2X-Z 10 - C D M 2 X L Z - M9BW. Port thread type. Nil TN TF. Rc NPT. Rubber bumper only. Cylinder stroke (mm) Action

Rotary Clamp Cylinder

Series 10-ZSE40A(F)/10-ISE40A

Series AV2000/3000/4000/5000

Compact Guide Cylinder

Compact Guide Cylinder Series MGQ

ROBO Cylinder Rotary Straight Motor Model 64mm Width 200V Servo Motor I N T P O. Notes on Selection. Deceleration Rated torque

How to Order. Nozzle. Nil Connection size N02 N03 F02 F H06 H08 H10 H07 H09 H11

Automatic exchange of robot hand tools, FMS (flexible manufacturing system) implemented for assembly lines.

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Transmitters: Relay Valve VR4151/4152

Compact Cylinder: Large Bore Size Type Double Acting, Double Rod. How to Order. Cushion C Rubber bumper. Action. D Double acting

Dual Rod Cylinder: Double Rod Type. How to Order. Load voltage Auto switch model Perpendicular In-line 3-wire (NPN equivalent) Y7NWV Y7NW 5 V, 12 V

Series RSH/RS1H. To stop pallets gently. Heavy Duty Stopper Cylinder. Stopper cylinder with built-in shock absorber. ø20, ø32 ø50, ø63, ø80

High Precision Scale Cylinder. How to Order. Connector. Cable suffix Nil Extension cable C Extension cable & connector

Transmitters: Relay Valve

VCHR Series. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order

Specifications Fluid. Basic Roller lever. Mechanical operation. One way roller lever. Roller plunger. Push button (Flush) Manual operation

Compact Cylinder/Plate type

New cylinder body allows small auto switches to be mounted on 4 surfaces.

Transcription:

Frame Clamp Cylinder WRF100 Spatter Resistant Cylinders for Arc Welding High output 20,000 N (Operating pressure: At 0.5 MPa) High clamping force makes it suitable for a broad range of applications Clamp Cylinders High repeatability Catcher (detented positioning structure) is a standard feature for repeatable positioning. Dowel pin holes for repeatable mounting when reassembling Allows for repeatable mount positioning in reassembly. Positioning dowel pin holes for jig Gas/Air Switching Valve Clamp Catcher Positioning dowel pin holes for jig Positioning dowel pin holes for fixing cylinder Detection Switches Optional spatter protective cover available Modular structure allows easy assembly even after the cylinder is installed. Standardized T-type arms and S-type arms Shape selectable to meet specifications/application. T-type arm width: 200, 240, 270 mm S-type arm width: 130, 200, 240 mm Tubing Protective cover Clamping force characteristics T-type arms S-type arms Fittings <Relationship between clamp position and clamping force> Refer to the following graph for the relationship between a distance H from a clamp position when the mutually acting catchers are engaged and a clamping force F. Clamping force (when 0.5 MPa supplied) Clamping force F (N) 30,000,000 20,000 15,000 10,000 5,000 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Distance H from clamp position (mm) L0 Assigned dimension when clamped (Catchers engaged) Catchers F A T-type arms H L0 Assigned dimension when clamped (Catchers engaged) Catchers A F S-type arms Generated position of clamping force F (mm) Arm type A T200, T240, T270 S130, S200, S240 107 H 80 Flow Control Equipment

Frame Clamp Cylinder WRF100 How to Order WRF100 T200 C Protective cover Nil Without cover C With cover Unclamped position Clamp arm Symbol T-type arms 200 T200 Symbol S130 S-type arms 130 T240 240 S200 200 270 240 Clamped position T270 S240 Note) This product does not include the limit switch. (The limit switch should be prepared by the customer.) Applicable limit switches have part numbers listed on the right. For mounting the limit switch, order the switch mounting bracket (WRF-BK) separately. For details, refer to page 86. Specifications <Applicable limit switches for part number> OMRON Corp.: WLG2-LDAS-DGJS03T Azbil Corp.: 1LS74-JWC-P0 Bore size 100 mm Stroke 48 mm Fluid Air Proof pressure 0.8 MPa Maximum operating pressure 0.5 MPa Minimum operating pressure 0.2 MPa Ambient and fluid temperature 10 to C (No freezing) Clamp side : None Cushion Unclamp side: Rubber bumper Lubrication Non-lube Operating time 1.0 s or more (Both clamp and unclamp) Arm opening angle 24 ( each side) Clamping force 20,000 N or more (At 0.5 MPa) Note) 47 kg (WRF100-T200) Weight 47 kg (WRF100-S200) Note) For the position where the clamping force is generated, refer to the dimensions on pages 82 to 84. 81

Frame Clamp Cylinder WRF100 Dimensions WRF-T /T-type clamp arms (Without cover) WRF100-T200/T240/T270 2 x M12 x 1.75 depth 24 15 108 4 x M8 x 1. depth 12 15 80 Spatter Resistant Cylinders for Arc Welding Clamp Cylinders (2 x 4 x M5 x 0.8 through) For limit switch mounting 100±0.3 70 13 15 10 40 Switch mounting bracket Note 2) +0.015 2 x ø8h7 ( 0 ) depth 12 Fulcrum 1 C 55 Note 3) 107 F ±0.05 B A±0.5 70 55 2 x 4 x M10 x 1.5 depth 12 2 x 2 x ø8h7 ( +0.015 0 ) depth 12 Gas/Air Switching Valve (70) 330 270 ±0.3 52 193 70±0.05 (173) 75 85 95 133 (58.7) Detection Switches Rc 1 / 4 Clamp side port (10) (30.2) (30.2) 139 Rc 1 / 4 Unclamp side port Note 1) 100 306 3 100 +0.015 4 x ø8h7( 0 ) through 143 115 82±0.05 50 Fittings Tubing 4 x ø14 through (mm) Arm type A B C T200 T240 T270 200 240 270 340 3 380 29 19 9 320 330±0.05 Note 1) This product does not include the limit switch. Note 2) For mounting the limit switch, order the switch mounting bracket (WRF-BK) separately. For details, refer to page 86. Note 3) The symbol F in the dimensions indicates the position where the clamping force is generated defined by the product specifications. 82 Flow Control Equipment

WRF100 Dimensions WRF-S /S-type clamp arms (Without cover) WRF100-S200/S240 2 x M12 x 1.75 through 108 4 x M8 x 1. depth 12 80 0.015 0 2 x ø8h7 ( ) depth 12 0.05 (2 x 4 x M5 x 0.8 through) For limit switch mounting 36 0.2 13 10 20 Note 2) Switch mounting bracket Fulcrum ( C) A B 0.5 2 x M10 x 1.5 through 10 30 110 90 Note 3) 107 F 2 x 4 x M10 x 1.5 depth 12 0.015 0 2 x 2 x ø8h7 ( ) depth 12 1 45 70 (70) (58.7) (173) 380 270 0.3 193 52 70 0.05 75 85 133 95 Rc 1 / 4 Clamp side port (10) (30.2) (30.2) 139 Rc 1 / 4 Unclamp side port Note 1) 100 306 3 100 0.015 0 4 x ø8h7 ( ) through 143 115 82 0.05 50 4 x ø14 through Arm type S200 S240 (mm) A B C 200 340 29 240 3 19 320 330 0.05 Note 1) This product does not include the limit switch. Note 2) For mounting the limit switch, order the switch mounting bracket (WRF-BK) separately. For details, refer to page 86. Note 3) The symbol F in the dimensions indicates the position where the clamping force is generated defined by the product specifications. 83

WRF100-S130 Dimensions other than those below are the same as WRF100-S200/S240 on page 83. Frame Clamp Cylinder WRF100 Spatter Resistant Cylinders for Arc Welding 36 0.2 Note 2) Switch mounting bracket 417.5 147.5 134.5 Fulcrum 80 37 62 30 0.05 39 Note 3) 107 320 130 F 0.5 20 4 x M12 x 1.75 depth 24 4 x ø17 through 0.015 4 x ø10h7 ( 0 ) through Gas/Air Switching Valve Note 1) Note 1) This product does not include the limit switch. Note 2) For mounting the limit switch, order the switch mounting bracket (WRF-BK) separately. For details, refer to page 86. Note 3) The symbol F in the dimensions indicates the position where the clamping force is generated defined by the product specifications. Flow Control Equipment Fittings Clamp Cylinders Detection Switches Tubing 84

WRF100 Dimensions T S WRF-S C/With protective cover WRF100-T200C Note) Protective cover dimensions shown in the figures are the same even if arm types are different. 144.2 148.8 LED inspection window for limit switch 459.2 249.6 207.6 268.6 6.6 (Max.) (270) Piping entry 195.6 153.6 Cover L mounting side Cover R Protective Cover Kit (Option) A protective cover can be retrofitted. Fixing method for protective covers w Applicable product Kit no. Contents WRF100-S130 WRF-C130 q Cover L (1 pc.) WRF100-T200 WRF-C200 w Cover R (1 pc.) WRF100-S200 e Top covers (2 pcs.) WRF100-T240 r Hexagon head bolts (4 pcs.) WRF-C240 WRF100-S240 t Flat washers (4 pcs.) y Cover mounting bolts (8 pcs.) WRF100-T270 WRF-C270 t r e Tightening torque for cover mounting bolts Location Tightening torque (N. m) r y 3.0 to 4.0 5.0 to 7.0 q <Mounting procedure> 1. Mount the cover L (q) and cover R (w) on the cylinder body. Mount the cover L (q) on the side where a limit switch is mounted. 2. Mount the top covers (e) to the cover L (q) and cover R (w). y When mounting the protective cover, confirm that all air has been exhausted from inside the cylinder. 85

Limit Switch Mounting Bracket (Option) Bracket for attaching a limit switch Fixing method for switch mounting brackets Applicable product Kit no. Contents Applicable to all types WRF-BK q Switch mounting bracket (1 pc.) w Bracket mounting bolts (4 pcs.) e Switch mounting bolts (8 pcs.) r Flat washers (8 pcs.) Tightening torque for mounting bolts of switch mounting bracket Location Tightening torque (N. m) w e Frame Clamp Cylinder WRF100 5.0 to 7.0 3.0 to 4.0 Spatter Resistant Cylinders for Arc Welding Clamp Cylinders q Not included in this product. (The limit switch should be prepared by the customer.) r e Piping port w 1 When mounting accessories, confirm that all air has been exhausted from inside the cylinder. 2 A limit switch can also be mounted on the side opposite to that with the piping port. Note) This product does not include the limit switch. (The limit switch should be prepared by the customer.) Applicable limit switches have part numbers listed below. For mounting the limit switch, order the switch mounting bracket (WRF-BK) separately. <Applicable limit switches for part number> OMRON Corp.: WLG2-LDAS-DGJS03T Azbil Corp.: 1LS74-JWC-P0 Flow Control Equipment Fittings Gas/Air Switching Valve Detection Switches Tubing 86

WRF100 Specific Product Precautions Be sure to read this before handling. Refer to page 134 for Safety Instructions. For Actuator Precautions, refer to Handling Precautions for SMC Products and the Operation Manual on SMC website, http://www.smcworld.com Design Warning 1. When clamping with the clamping position offset horizontally, ensure that the offset is 120 mm or less from the center of cylinder. With a large offset, twisting forces will be applied to the cylinder. This twisting force can potentially accelerate wear and breakage of parts with the abrasion of sliding parts. In addition, changes in the force on the cylinder parts may cause dangerous movement to occur with forceful impact. 120 mm or less 2. Affix a protective cover in places where there is a danger of personal injury. A large gripping force is generated during clamping. If there is a possible pinching hazard, design the structure to avoid contact with the human body. 3. Securely tighten all stationary parts and connected parts so that they will not become loose. Take special care when the cylinder is installed where there is a lot of vibration, ensure that all parts remain secure. 4. Consider a possible loss of power. Measures should be taken to protect against bodily injury and equipment damage in the event that there is a loss of power to equipment controlled by pneumatics, electricity, or hydraulics. 5. Consider emergency stops. Design so that human injury and/or damage to machinery and equipment will not be caused when machinery is stopped by a safety device under abnormal conditions, a power outage or a manual emergency stop. 6. Consider the action when operation is restarted after an emergency stop or abnormal stop. Design the machinery so that human injury or equipment damage will not occur upon restart of operation. When the cylinder has to be reset at the starting position, install manual safety equipment. 7. No self-locking mechanism At air shutoff, there is no force generated to hold the workpiece. External forces will cause the workpiece to move out of place in the event that air is lost. Measures should be taken to protect against bodily injury with the hazard. 87