User s Guide FHG FLOW METERS. Shop online at. omega.com For latest product manuals: omegamanual.info

Vortex Flow Meter Model DVH

Model: TUR with transmitter. Output: pulses, 0-20 ma, 4-20 ma or 0-10 V, LED display, pointer indication, switching output

DOR. Insertion Paddle Wheel Flowmeter/Monitor. for low viscous liquids. Flow range: ,300 l/s to ,000 l/s. Flow velocity range: 0.

TUR. Turbine Wheel Flowmeter. plastic version for liquids. Measuring ranges: ,0 m 3 /h water. ± 1% of full scale

Allen-Bradley 1397 Pulse Encoder Interface Card

Vortex Flowmeter Model DVE

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

Compressed Air-Supply Meter

Better sealing solutions for reciprocating compressors

TWL-Exia. Resistance Thermometers according to DIN. Ignition Protection Exia. Pt 100-sensor class A respectively class B

CrimpTest-1 kn. Calibration Bracket

Rectangular photoelectric proximity switches

D6.. Butterfly valves. For controlled operation.

Mobile Hydraulics Solutions

TUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water)

PUMP SYSTEMS DOSING + TRANSFER

Pumps and Flow Measurement for the Polyurethanes Industry

NCP/NCB/NCS. Magnetic Float Switches. for Liquids

High Precision Turbine Wheel Flow Meter for Liquids

NELCONT 3000 BASIS WEIGHT VALVE PACKAGE

RCM. Direct Reading Flowmeter. for Liquids or Gases

NI PS-15/16/17 Side Mount Brackets

Selection Guide for P Series Pump Accessories & Options

Infographics on Electromobility (January 2019)

SM Series. High Pressure - All-Metal Flowmeter and Switch

Exceptional Accuracy and Durability for Tough Industrial Environments INDUSTRIAL FLOOR SCALES. VERTEX Industrial Floor Scales Heavy-Duty Design

Total credit to the non-financial sector (core debt), % of GDP Table F1.1

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids

WANNER ENGINEERING INC

The SHK manual chain hoist

KRACHT Singapore Marine Products

testing to perfection MultiTest-i Technical Datasheet

COVOL. Operating Data. Areas of Application. Measuring Ranges. Method of Operation. Fields of operation. Features. Installation information

MAN-P. Diaphragm Pressure Gauges. according to EN for Stringent Demands

The new STx chain hoist NEW. Sophisticated technology prepared for the future

PSF50 Paddle flow switch

DOR. Insertion Paddle Wheel Flow Meter/Monitor. for Low Viscous Liquids. Flow range: l/s to l/s. Flow velocity range: 0.

No.1. Side approach mechanism Precise lateral contacting. Catalogue 1.1. Test Probes Test Fixtures

WORLD MOTOR VEHICLE PRODUCTION BY COUNTRY AND TYPE QUARTERS June 14, 2018

CASE STUDY. A World Leader in a Niche Market. PAPST Fans Testing and Development of Automotive Fans. Germany. Automotive, Industrial, Consumer

Facts and figures INTEGRALPICKER V.

RUN ACCUM. TOTAL STOP BAT LOW HIGH

The SHK manual chain hoist

Butterfly valves for open-close applications and control mode

Product Overview INCH

European Aerosol Production 2016

Flow. Oval Wheel Flowmeter Model DON

SBS-Control. Table of contents. Operating Instructions BKS24-9A. Operating Instructions

Lifting Instructions for 1336 PLUS and FORCE D Frame Drives

Technical Data. BiRotor Plus Positive Displacement Meter

Standard Product Program. AirLINE & AirLINE Quick Type 8640 & Type 8644

Gear Type Flow Meter VC

Paddle Flow Monitor Model PSR/PSE

PROPORTIONALADVANTAGE

NGS. Dual-Magnet Float Switch. Pressure: up to 25 bar. Density: > 0.7 kg/dm 3. High switch capacity. Material: stainless steel 1.

BP Statistical Review of World Energy June 2017

Facts and figures MULTILIFT SELECT 6

Performance Derby: MSCI Regions/Countries Earnings & Revenues Growth 2019E / 2018E / 2017A

Portable Compressors MOBILAIR M 122 With the world-renowned SIGMA PROFILE Free air delivery 11.1 m³/min

SFC-FID ASTM System. SFC-4000 Series SFC. Performance Innovation Reliability

D633/D634 SERVOVALVES FOR ELECTROHYDRAULIC POSITION, VELOCITY, PRESSURE OR FORCE CONTROL SYSTEMS WITH HIGH DYNAMIC RESPONSE REQUIREMENTS

CASE STUDY. LINK Engineering Company Inc. Resolving Customers Brake Noise Issues

Slide Bearings Type E For Shaft Diameter Range mm Main Application Field Electric Machines

ABS Dry Installed Waste Water Pumps Series FR

D661-G...A Series Servovalve With Bushing and Integrated 24 Volt Electronics ISO 4401 Size 05

Roll Up WireFree IR. Installation instructions

Knife gate valve TV. Data is only for informational purpose. All specifications are subject to change without notice issue 9

Primary energy. 8 Consumption 9 Consumption by fuel. 67 th edition

FHA-C Mini Servo Actuators with Multi-turn Absolute Encoder

Global Dialysis - Cost per Dialysis Session

Knife gate valve MP. Data is only for informational purpose. All specifications are subject to change without notice issue 5

FORGED STAINLESS STEEL Rack And Pinion Actuator S Series

Thick Film Chip Resistors

VHS... Screw Flow Meter

The SW winch

Packing Data Installation Instructions

UXC.COM A PUBLICATION OF. NPO Overview 1501 MACY DRIVE ROSWELL, GA PH FX

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

I. World trade in Overview

Over time consistency of PPP results in the OECD countries

AUSTRIA. Table 1. FDI flows in the host economy, by geographical origin. (Millions of US dollars)

SentronicPLUS IO-Link CLASS A Electronic Pressure Regulator. Installation Manual

Rotor locks. Hydraulic Electromechanical Modular design... all from one single supplier

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

A multi-model approach: international electric vehicle adoption

THE WITTUR ANSWER TO THE MACHINE ROOMLESS MARKET REQUIREMENTS. MRL W Line. EMOTION IN MOTION

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Binary Counter Valve. Catalogue PDE2308TCUK-ab

Electromagnetic Flowmeters. Product Overview.

Type Number Symbol Value Units

Test Probes Test Fixtures INGUN. Test Fixtures for low PCB volumes. Change made easy

Transcription:

1 Solutions for Fluid Technology RS SERIES FLOW MEASUREMENT TECHNOLOGY

2 RS FLOW METER RS flow meters measure the flow rate based on the screw pump principle. A pair of rotors fitted precisely into the housing constitutes the measuring element. An integrated gear and non-contact signal pick-up system detects the rotations of the measuring element and converts them to digital pulses. Together with the housing walls, the rotor edges form closed measuring chambers in which the fluid is transported from the inlet to the outlet side. The fluid volume put through within one main rotor rotation is the rotation volume, which is divided by the sensing gear and digitised, processed and output in the sensor module. In case of an 1-channel evaluation, a separate directional signal is available. An adjustable pulse filter can offset and suppress negative flows (e.g. generated by vibrations) while still in the device. The frequency of the output signals is proportional to the flow (volume flow) and depends on the respective flow meter size. The frequency range is from 0 to khz. The preamplifier is protected against reverse polarity and incorrect connection. It is suitable for fluid temperatures of -30 C to +120 C (-22 F to +248 F) and is mounted directly on the RS flow meter. ADVANTAGES High degree of precision that is mostly independent of viscosity Pulsation-free measurement Lowest pressure losses Short response time due to innovative rotor profile and reduced mass Highest functionality due to intelligent sensor technology Gentle fluid measurement FLOW METER SELECTION For the trouble-free, safe and reliable operation of the flow meters, selecting the correct type and size is critical. Because of the wide variety of applications and flow meter designs, the technical data in the VSE catalogue are of a general nature. Certain properties of the devices depend on type, size, and measurement range as well as the liquid to be measured. Please contact VSE or one of our sales and service representatives for detailed information about the appropriate flow meter for your particular application. SENSOR SYSTEM EXPLANATION The non-contact pick-up system consists of two GMRbridges (sin/cos), which are located in a sensor unit in cartridge design. It detects the movement of the sensing gear and routes the sin/cos-signals to the preamplifier electronics. The preamplifier electronics digitise and amplify the sensor signals and multiply them by a high-resolution interpolator using adjustable settings. The square wave signals are bidirectional and can be utilised by any evaluating instrument as well as computers and PLC-controls. The resolution is selectable in steps from factor 1 to 128.

TECHNICAL DATA OVERVIEW 3 Size Measurement range (Q max. ) l/min. RV ccm/rev VE ccm/imp. K-Factor* Imp./l min. K-Factor* Imp./l max. P max. bar Filtering my RS 0.50 (120) 15.7 0.5815 1,720 220,000 450 250 RS 400 1.00 400 (525) 56.6 3.138 318 40,800 450 250 RS 800 4.00 800 (1,000) 180.0 10 12,800 450 500 RS 2500 10.00 2,500 (3,000) 666.0 37 27 3,459 40 500 *adjustable FREQUENCY RANGE 0 khz, adjustable REPEATABILITY ACCURACY ± 0.05 % with same operating conditions MEASUREMENT ACCURACY ± 0.5 % (1 %)** of measured value with viscosity of > 21 cst. **RS 2500 MATERIALS GRAY CAST IRON MODEL EN-GJS-400-15 (EN 1563)/16 Mn Cr 5 STAINLESS STEEL MODEL Stainless steel 1.4305/1.4112, additional available upon request BEARING Fluid-dependent as anti-friction bearing or SSIC/wolfram carbide friction bearing SEAL FPM (standard) PTFE, NBR, EPDM upon request FLUID TEMPERATURE -30 C +120 C; (-22 F to +248 F) VISCOSITY RANGE 1 1.000.000 cst. INSTALLATION POSITION Any, using selectable connection units, also customer specific SUPPLY VOLTAGE 10 28 VDC CURRENT CONSUMPTION 65 ma at 24 VDC unloaded DELAY 8 µs PROTECTION CLASS IP 65 EXPLOSION PROTECTION Protection type: intrinsically safe, available soon

4 FLOW RANGES Size Baugröße Flow Durchflussbereich range 0 up to 0120 bis l/min 120 l/min Baugröße Flow Durchflussbereich range 0 up to 10 0 bis l/min 10 l/min Flow Durchflusswiderstand range pressure drop p p Flow Durchfluss range Q Flow Durchfluss range Q Size Baugröße 400 400 Flow Durchflussbereich range 0 up to 0 500 bis l/min 500 l/min Flow Durchflusswiderstand range pressure drop p p Flow Durchfluss range Q Flow Durchfluss range Q Size Baugröße 800 800 Flow Durchflussbereich range 0 up to 01,000 bis 1.000 l/min l/min Durchflusswiderstand Flow range pressure drop p p Flow Durchflusswiderstand range ipressure drop p p Flow Durchflusswiderstand range ipressure drop p p Baugröße Flow Durchflussbereich range 0 up to 050 bis l/min 50 l/min Size 2500 Flow range 0 up to 3,000 l/min Flow range pressure drop p Flow Durchfluss range Q Flow range Q

DIMENSIONS 5 RS Preamplifier Test Port G 1/4 Sensor module Test Port G 1/4 Connection PT Earthing M8 15 deep on both sides Weight 12 kg AR. -E.. with sensor module AR. -E.. M8 15 deep on both sides AR. -T. with sensor module AR. -T.. Connection SAE 3/4 4 x M10 18 deep Weight 12.7 kg RS 400 Preamplifier Test Port G 1/4 Sensor module Test Port G 1/4 Connection PT Earthing AR. 400-F.. with sensor module AR. 400-F.. M8 15 deep on both sides Weight 22 kg 4 x M8 15 deep on both sides AR. 400-V.. with sensor module AR. 400-V.. Connection SAE 1 1/4 4 x M14 25 deep Weight 24.8 kg

6 DIMENSIONS RS 800 Preamplifier Sensor module Test Port G 1/4 Connection PT Test Port G 1/4 Earthing Ring bolt AR. 800-H.. with sensor module AR. 800-H.. 4 x M8 15 deep on both sides Weight 81 kg AR. 800-X.. with sensor module AR. 800-X.. Connection SAE 2 Weight 81 kg RS 2500 Preamplifier Sensor module Test Port G 1/4 Earthing Ring bolt DN PN 40 Flange connection dimension AR. 2500-R.. DIN EN 1092 Weight 120 kg

TYPE CODE 7 RS RS 400 RS 800 RS 2500 Size 1 2 5 10 25 32 50 64 128 Interpolation Selectable interpolations factor G EN-GJS-400-15 (DIN EN 1563) E Stainless steel 1.4305 (V2A) X Stainless steel 1.4571 (V4A) Material R Connection type 0 Factory-provided Pipeline connection 1 Ball bearing 6 Hard metal sleeve bearing 7 Angular contact ball bearing 2 Standard Bearing Standard Backlash V P T E B FPM (Viton) Standard NBR (Perbunan) PTFE EPDM EPDM - 41B8 Sealing type X Construction range RS 800 / 50 G R 0 1 2 V / X Example AR G 800 - G V 1 1 0 N / X Modification figure factory-provided Flow Sensor Connection for temperature sensor Special design N Construction range X Standard Modification figure factory-provided Sealing type Sensor module Test port 1 0 Without connection for PT 1 With connection for PT With one test port G 1/4 1 Sensor module GSM 01 no longer valid 2 Sensor module GSM 01 Size Connection E F G H V P T E B G 1 G 1 1/4 G 1 1/2 G 2 FPM (Viton) Standard NBR (Perbunan) PTFE EPDM EPDM - 41B8 R T V X DN PN40 (Flange connection DIN EN 1092) SAE 3/4 SAE 1 1/4 SAE 2 Material RS 400 RS 400 800 RS 800 2500 RS 2500 G EN-GJS-400-15 (DIN EN 1563) E Stainless steel 1.4305 ( V2A) X Stainless steel 1.4571 ( V4A)

8 SENSOR MODULE SENSOR ELECTRONICS DESCRIPTION A special sensor system detects any movement of the pair of rotors or of the liquid column. For this purpose, a precision gear connected to a shaft of the rotor pair is scanned by a special magnetoresistive sensor. The scanning sensor includes two GMR-bridges (sin/cos) and is housed in a removable stainless steel cartridge case together with a signal conditioning and amplifier unit. The downstream electronics unit features a high-resolution sin/cos-interpolator, which is adjustable with ten different resolution factors. Furthermore, a programmable signal filter is available as well, which can offset unwanted negative pulse sequences up to an adjustable degree. In addition, a signal for a separate direction detection, e.g. in case of a 1-channel evaluation, is provided by the electronics. Optionally, this output can be used for the detection of excess flows and temperatures. FEATURES Adjustable interpolation factors IPF: 1, 2, 5, 10, 25, 32, 50, 64,, 128 Adjustable pulse filtering: up to 22% of the rotation volume Adjustable preferential direction for filtering processes Generating frequencies up to,000 Hz Output of a separate directional signal or error signal (selectable) Detection of stalled sensor or sensor faults/ magnet wheel damages Flow overload detection with logging Excess temperature detection with logging Detection of exceeding the max. permissible highest frequency (>,000 Hz) Readable error code LEDs Automatic offset adjustment of the GMR-sensor-bridge (sinus, cosine)

9 TECHNICAL DATA RS Max. permissible flow 126 l/min (n = 8025.2 rev/min) Min. permissible flow 0.25 l/min (n = 15.9 rev/min) Q[l/min] FLOW vs FREQUENCY IP F=1 2 5 10 25 120 110 32 90 80 70 60 50 40 30 20 RS 50 64 128 10 f[hz] 0 10 1.000 10.000.000 RS 400 Max. permissible flow 525 l/min (n = 6,196.4 rev/min) Min. permissible flow 0.5 l/min (n = 5.9 rev/min) Q[l/min] 520 500 480 460 440 420 400 380 360 340 320 300 280 260 240 220 200 180 160 140 120 80 60 40 20 0 FLOW vs FREQUENCY RS400 IP F=1 2 5 10 25 32 10 1.000 10.000.000 50 64 128 f[hz]

10 RS 800 Max. permissible flow 1,050 l/min (n = 3,888.9 rev/min) Min. permissible flow 5 l/min (n = 18.5 rev/min) Q[l/min] FLOW vs FREQUENCY IP F1 2 5 10 25 32 50 1050 0 950 64 900 850 800 750 700 650 RS800 600 550 500 450 128 400 350 300 250 200 150 50 f[hz] 0 10 1.000 10.000.000 RS 2500 Max. permissible flow 3,000 l/min (n = 3,003 rev/min) Min. permissible flow 10 l/min (n = 10 rev/min) Q[l/min] 3000 2900 2800 2700 2600 2500 2400 2300 2200 2 2000 1900 1800 1700 1600 1500 1400 1300 1200 1 0 900 800 700 600 500 400 300 200 0 10 FLOW vs FREQUENCY IPF1 2 5 10 25 32 50 64 128 f[hz] 1.000 10.000.000

11 PULSE FILTERING PRINCIPLE Oscillations in fluid systems manifest themselves through constant forward and backward movements of the liquid column, which is also detected by the rotor sensors and converted into proportional electronic pulses or edge sequences. These generated pulses can be incorrectly interpreted by the downstream evaluating unit or controller, which can be very distracting for the respective operating process. The signal filtering function of the internal electronics continuously offsets these generated edges during the rapid forward and backward movements of the rotor measuring element. The signals at the channel outputs are also suppressed until the internal offset is equalized or the initial position of the rotor measuring element has been reached again. The user is able to set the degree of filtering in the form of partial volumes using rotary coding switches. SUPPRESSED VOLUME WITH PULSE FILTERING ACTIVATION [ml] Filter position RS X RS 400X RS 800X RS 2500X 0 0 0 0 0 1 0.145375 0.7845 2.5 9.25 2 0.29075 1.569 5.0 18.50 3 0.436125 2.3535 7.5 27.75 4 0.5815 3.138 10.0 37.00 5 0.726875 3.9225 12.5 46.25 6 0.87225 4.707 15.0 55.50 7 1.017625 5.4915 17.5 64.75 8 1.163 6.276 20.0 74.00 9 1.308375 7.0605 22.5 83.25 10 1.45375 7.845 25.0 92.50 11 1.599125 8.6295 27.5 101.75 12 1.7445 9.414 30.0 111.00 13 1.889875 10.1985 32.5 120.25 14 2.03525 10.983 35.0 129.50 15 2.180625 11.7675 37.5 138.75 Q t U Signalausgabe output without ohne Filterung filtering 1 2 Filtering Filteraktivierung activation Filtering Filterdeaktivierung deactivation 2 4 6 8 10 12 141618 20 22 24 26 28 30 32 31 29 27 25 23 21 1917 15 1311 7 5 3 1 1 3 5 7 9 11 13 1517 19 21 23 25 27 29 31 30 28 26 24 22 20 1816 1412 10 8 4 2 0 9 6 Signalausgabe output with mit Filterung filtering 1 2 Preferred Vorzugsrichtung direction Opposite Entgegengesetzte direction Richtung Preferred Vorzugsrichtung direction t Pulse filtering chart

12 ELECTRICAL DATA 12 POWER SUPPLY Supply voltage U = 10 28 VDC; reverse pole protection Current consumption I 0 = 65 ma (at 24 VDC); unloaded Delay t V = 8 µs max. (between scanning and measured value) SIGNAL OUTPUTS Output signal shape Quadrature signals (A, B with 90 phase shift) Directional output Positive high (24 V); negative low (0.8 1 V) Error output Active high (24 V); inactive low (0.8 1 V) Max. output frequency khz Signal voltage output (channel 1, channel 2, direc/err) V SS = 9 27 VDC Signal output current (channel 1, channel 2) I OUT = 300 ma max. at 24 VDC Output final stages Push-pull-final stages, current-limited, short-circuit proof, internal cable adjustment, small saturation voltage, thermal shutdown with hysteresis, high-impedance outputs in case of error The current publication of this catalogue supersedes all information from previous publications. VSE reserves the right to make changes and substitutions. VSE is not liable for any printing errors. Reproduction, including excerpts, is permitted only after written approval by VSE. Last revised: 09/2015

13 SERIES / ACCESSORIES / CUSTOMER SPECIFIC SOLUTIONS 13 VS SERIES VHM SERIES EF SERIES Flow measurement, Precision dosing, Systems monitoring, Open/closed loop control, Process control, Plastics technology Hydraulic systems Automobile industry Paints, dyes Chemicals Pharmaceuticals Two-component mixers Petrochemicals Oils Greases Printing inks VTR SERIES CUSTOMER SPECIFIC PROCESS CONTROL Waterbased liquids Water Oils Petrochemicals Customer specific solutions can be realised at competitive prices in the shortest time. We develop your solutions in all current materials such as steel, stainless steel, titanium and aluminium as well as bronze materials. Dyes, paints, (hot-) adhesives or oxy or PUR-materials also with fillers epcan be reliably measured. Pressures up to 700 bar and temperatures up to 210 C (410 F) are included in our standard product range. AUTOMOBILE INDUSTRY ACCESSORIES REPAIR AND CALIBRATION SERVICE Whether for installation in vehicles or in climatic exposure test cabinets; we have a solution for almost every measuring application. High reliability, low space requirements and highest measurement accuracy, also for difficult media or aggressive atmospheres distinguish our products. Connection blocks also heatable, sandwich plates with integrated ball valves and heating jackets for all current flow meters. Additional measuring connections for pressure and temperature. can be supplied from stock. Inhouse calibrations from 0.002 l/ min... 600 l/ min, traceable to a DKD normal. We are pleased to provide you with loan units for the time of repair or calibration. Repair and calibration also of external brands as well as electronic displays.

14 WORLDWIDE SERVICE Qualified advice through long-standing cooperation partners and own distribution companies personal competent efficient DISTRIBUTORS Austria Belgium Brasil Canada China* Czech Republic Denmark Finland France* Great Britain* Hungary India* Indonesia Iran Israel Italy* Japan Malaysia The Netherlands Norway Philippines Poland Russia Singapore Slovak Republic Spain South Africa South Corea Sweden Switzerland Taiwan Turkey USA* *own distribution and service companies VSE Volumentechnik GmbH Hönnestraße 49 58809 Neuenrade / Germany distributed by VSE Volumentechnik GmbH Postfach/P.O.Box 1229 58804 Neuenrade / Germany Phone +49 (0) 23 94 / 6 16-30 Fax +49 (0) 23 94 / 6 16-33 info@vse-fl ow.com www.vse-flow.com www.e-holding.de 09/15 www.plakart.de