Series 1 Pump. Series 2 Pump. Series 3 Pump

Similar documents
EfficleanTM OIL FILTRATION SYSTEM FOR FURNACE OIL & THERMIC FLUID

MAP Automatic Strainers In-Line Series

MICROPUMP MAG-DRIVE GEAR PUMPS

Vertical Multistage Pumps

The Filling Procedure

NMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST

General Catalog. A New Vision for Quality Pumps. General Catalog

Module 13: Mechanical Fuel Injection Diagnosis and Repair

Village Marine-PW Part Number: Pure Water Series PW 8,000-20,000 GPD. Installation, Operation & Maintenance

Installation Manual. Automated Fuel. Maintenance. System FUEL TECHNOLOGIES INTERNATIONAL LLC

Definitions of Technical Terms

Penberthy Automatic Injectors

70.03 Victaulic Vortex TM

Section 2: Big Bubba Filtration System

Lubrication & Maintenance Schedule

MAHLE Automatic Filter Series R8-30W

Inspection, Testing, and Maintenance Fire Pumps NFPA 25, Chapter 8 as amended by CCR, Title 19 Page 1 of 8

The electric motors are designed for driving equipment that requires continuous operation, and their high efficiency reduces energy consumption.

APP S 674 pumps APP S / APP S APP S

Installation, Operation, and Maintenance Manual Outdoor Glycol Feed System JWOP /055/100

Water pumps for Desalination APP 16-22

VERTICAL SERIES BOOSTER PUMPS

VERTICAL SERIES BOOSTER PUMPS

Model T5 Triplex Power Pump

Model T10 Triplex Power Pump

Includes electric operated valve Pressure gauge with siphon, vacuum breaker and air vent BOILER UNITS

Precision Pumping Solutions

Fluid Coil Installation, Operation and Maintenance

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31

Model RVL-20. Stainless Steel Low-Pressure Diaphragm Relief Valve

SAND FILTERS. Models: ECSF500, ECSF650, ECSF700, & ECSF800

The TR-Series are large volume,

CASH VALVE B SERIES PRESSURE REGULATORS

NECO Pumping Systems

Village Marine LWM The Little Wonder Modular Installation, Operation & Maintenance

OPERATOR S MANUAL AND PARTS LIST

HYDAC Process Technology Water Filtration Product Overview

MEASUREMENT SOLUTIONS FOR THE WATER & WASTEWATER INDUSTRY

ARIES THINWALL DRIPLINE

NEW! BOOSTER PUMPS. HBP/HBPS series 4" horizontal booster pumps. booster pumps

AH / AV. Advanced Series Unit Heaters AH / AV. Ruffneck

Universal is a family of commercial gas water heaters that are designed to fit into tight retrofit applications

Oil Pump. Features: AISIN aluminum die-casting technology allows for size and weight reduction.

WARCO CHEMAG SERIES GH FILTERS

W4100, W4200 & W4300 Electric Pump

NEW! NEW! Series 3100H HVLP AirSpray Gun HVLP 1 Qt. Cup Siphon Fed Guns Air Requirements: PSI

Installation Manual FTI-10A & FTI-20A SINGLE TANK. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

Model T25 Triplex Power Pump

CARBONATORS & WATER BOOSTERS

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

Exercise 3-1. Basic Hydraulic Circuit EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Complete hydraulic circuit

Everpure Claris filter cartridge family

INSTALLATION OPERATION SERVICE MANUAL

QCP Accessories. Pressure Feed Tanks. Wheel & Handle Kits

INSTALLATION OPERATION SERVICE MANUAL

05 Water Pressure Systems INTRODUCTION

US PETROLON LUBRICATION & FILTRATION CATALOG.

CLIMA. Take Control of Your System with. Gain Efficiency -> Save Energy. technological solutions

Secondary Coolant 301

Industry Air Purification System

Components for central heating

BOOSTER PUMPS PRODUCT FAMILY APPLICATIONS FAMILY COMPARISON CHART

Technical Data. Series Oval Flowmeter. Model 9400

TECHNICAL SPECIFICATIONS

A prolific inventor, John Bean interrupted his California retirement in 1884 to develop a continuous spray pump to combat orchard scale.

FIRE PUMPS F AI LISTED R LISTED N K S MOR S E P U IT Y S Y S T E M CE R T IF IE D

Polymer Makedown Systems

Exercise 3-1. Basic Hydraulic Circuit EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Complete hydraulic circuit

Offshore Marine Labs Sea Quencher. The Sea Quencher Installation, Operation & Maintenance

Ph: (07) Fax: (07) Pump Manual

Fixed Displacement Gear Pumps

BKI 1000 Commercial/Industrial RO Unit

Multistage Pumps MP, MPA, MPB, MPV SIZES DN 40 - DN 125. Jansen Pompentechniek T: +31(0) E:

RSV Series In-Line Vertical Multi-Stage, Ring Section Pump September 2013

High vacuum transformer oil purification (HVTOPS) & Dielectric OIL Purifier System (DOPS)

SPECIFICATIONS FOR GASOLINE DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B1000 M-G

Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating VENT 'A' FLOW

Port size: 1 NPT Shaft size: 5/8 Solid or 1/2 Hollow. Pump shaft rotation: CW Standard/CCW Optional. Weight: 19 lbs. Rollers: Ultra Rollers standard

COBRA NC B. Dry Screw Vacuum Pumps. Standard Equipment. Description

Security device Non return valve

OFX7 Operating Maintenance and Troubleshooting Manual L-4219

The pumps are fixed displacement pumps in which the flow is proportional to the number of revolutions of the input shaft and the pump displacement.

The System Features These Advantages: Designing the Low Pressure Oil Return System

DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS

FLUID HANDLING: Drum Filter Cart

FLUID HANDLING: Drum Filter Cart

APP pump instruction APP and APP 16-22

Series: EC & ED. EC & ED RPM - 60Hz. (See Indivdual curves for symbol number)

HARMSCO Filtration Products BC6 Series

26 Series Stainless Steel 2-way Ball Valves

Temperature Regulators

TWINFORCE UNITS. Units 15,000 PSI (1,034 BAR) HORSEPOWER CHART

HL Series Centrifugal Fire Pumps Operation and Maintenance Instructions

521B0851 DKCFN.PD.010.FB1.02

521B0850 DKCFN.PD.010.FA2.02

PAH / PAHT / PAHT G pumps

SPECIFICATIONS FOR DIESEL DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

S200-P Series Centrifugal Fire Pumps Operation and Maintenance Instructions

TECHNICAL DATA. Trimpac 244a. April 15, 2011

Transcription:

Series 1 Pump PROCON's Series 1 pumps have the protection of an integral inlet strainer. The standard strainer is a 100 mesh wire screen. It traps particles that can cause serious damage to the pump. The strainer is equipped with a removable cap to allow periodic cleaning, every 4 months under normal conditions (more frequently with hard or turbid water). The clamp-on mounting style is shown in the photo; bolt-on mounting is also available. Series 2 Pump PROCON's Series 2 pumps have the same features as the Series1 except they do not have the integral strainer. Series 1, 2 and 3 are available in 11 flow rates: 15, 25, 35, 50, 60, 70, 80, 100, 110, 125 and 140 gallons per hour at 250 psi. Clamp-on mounting style is shown in the photo; bolt-on mounting is also available. Series 3 Pump PROCON's Series 3 pumps boast all the unique design features of other PROCON pumps. Because the pump body and all the internal metal parts are made from stainless steel, the Series 3 is well suited for pumping a variety of fluids not suitable with brass. Your PROCON factory representative can advise you on the correct pump for the fluids you intend to use. Clamp-on mounting style is shown in the photo; bolt -on mounting is also available.

Series 4 Pump PROCON's Series 4 is designed and built to meet your needs for flow rates ranging from 115 to 330 gallons per hour at 250 psi. This PROCON pump maintains all the quality features and construction of our Series 1, 2, & 3 pumps. Clamp-on mounting style is shown in the photo; bolt -on mounting is also available. Series 5 Pump PROCON's Series 5 is designed and built to meet your needs for flow rates ranging from 115 to 330 gallons per hour at 250 psi. This PROCON pump maintains all the quality features and construction of our Series 1, 2, & 3 pumps. Clamp-on mounting style is shown in the photo; bolt -on mounting is also available. Series 6 Pump PROCON's Series 6 is designed and built to meet your needs for higher flows. The flow rate capacity for this pump ranges from 300 to 660 gallons per hour at 250 psi. This series pump is available only in bolt-on style. No integral relief valve is available. MagDrive Series 2/3 Pumps Due to the elimination of the mechanical seals, PROCON s family of MagDrives provides you with a virtually leak proof pump. They are designed for those applications which use a hard to contain fluid (e.g. glycols, oils, low surface tension fluids, etc.). PROCON s Series 2 and 3 MagDrives are available in 11 flow rates: 15, 25, 35, 50, 60, 70, 80, 100, 110, 125 and 140 gallons per hour with discharge pressures up to 180 psi. Brass or stainless steel construction is available. machines, Beer cooling systems, cooling for TIG Welders, Reverse Osmosis systems, ultra-filtration systems, cooling circulation, constant temperature control, atomizing / misting systems, Automated pesticide misting systems, carwash machines, steam cleaning machines, cooling for X-Ray and medical lasers, water purification, boiler feeds, pressure

MagDrive Series 5 Pump Due to the elimination of the mechanical seals, PROCON s family of MagDrives provides you with a virtually leak proof pump. They are designed for those applications which use a hard to contain fluid (e.g. glycols, oils, low surface tension fluids, etc.). PROCON's Series 5 MagDrive pump is designed and built to meet your needs for flow rates ranging from 115 to 330 gallons per hour at 250 psi. This PROCON pump maintains all the quality features and construction of our Series 2 & 3 MagDrive pumps. MagDrive Series 6 Pump Due to the elimination of the mechanical seals, PROCON s family of MagDrives provides you with a virtually leak proof pump. They are designed for those applications which use a hard to contain fluid (e.g. glycols, oils, low surface tension fluids, etc.). PROCON's Series 6 MagDrive is designed and built to meet your needs for higher flows. The flow rate capacity for this pump ranges from 300 to 660 gallons per hour at 250 psi. No integral relief valve is available. CMP (Canned Motor Pump) The CMP-7000 is a wonderful advancement in pump technology; offering the benefits of longer service life and lower life cost. The CMP-7000 is an integrated canned pump / motor package featuring a single shaft design. It has a 2 year limited warranty and offers run dry capability. The pump is designed with PROCON s patented thermal protection allowing the pump to automatically cut off in a run dry scenario and then recycle every 10-15 minutes until the run dry situation is remedied. This patented thermal protection allows the pump to run in a dry environment without damage to the internal carbon components.

Saltwater Pumps PROCON's saltwater pumps are designed for use in brackish water or sea water. These pumps are comprised of an austenitic stainless steel, 254 SMO, which possesses very high resistance to pitting and crevice corrosion. This Grade of steel is superior to 303 or 304 stainless steel. Internal components are composed of 316 stainless steel. A single piece rotor is used to prevent shaft separation. Requires a freshwater flush. Available in Series 3 (Bolt- On) or Series 5 (Bolt-On or Clamp-On) configurations. Applications include: Desalination, Reverse Osmosis, any application involving Brackish or Saltwater. 48YZ Frame (Clamp-on) Motor The 48YZ Frame Motor is mainly used for lower horsepower applications. It is available in 1/4 HP, 1/3 HP, 1/2 HP, and 3/4 HP models. 56C Frame (Bolt-on) Motor The 56C Frame Motor is mainly used for higher horsepower applications. It is available in 1 HP, 1.5 HP, 2 HP, and 2.5 HP models. Clamps PROCON's V-Band Clamps are used to attach pumps with clamp-on style mountings to 48YZ Frame Motors. Adapter - Coupling Unit This unit is used to attach pumps with bolt-on style mountings to 56C Frame Motors.

Couplings PROCON's different styles of couplings and mounting arrangements can be tailored to optimize service life and minimize down time in certain applications. External Bypass Valve PROCON's external bypass valve provides the protection of PROCON's patented relief valve system to any style pump. It also removes the recirculation path from inside the pump to the external bypass, thereby reducing damage to the internal components of the pump due to the heat produced by excessive recirculation.