Parameters. Overview. Functions. HDL Buspro Definition for Cable. Important. Do you need help? Contact

Similar documents
SafeRing / SafePlus Retrofit Motor Operation on 3PAE Mechanism F and SGT Modules

RAY. Product Manual Produkthåndbok

Date of occurrence Location name Alnabru terminal Local time 03:40 Latitude Railway vehicle movement events Trains collision Trains collision

BenchTop Extraction Arm FX2

Target Retrieval Systems

Dillenger Electric Bikes

Issue 2.0 December EPAS Midi User Manual EPAS35

i form av lodding og strmtyverper du hos oss s har du garanti om at du fr et produkt med kun kontakter som skal klikkes p plass i motoren din - noe

BB-LEISGER International GmbH

MOTOR MANUAL. Rev 9.2 TRSX-36024V. Note: Check our website for the latest version of this manual. Super Target Systems.

Curtains. Motors & Accessories. Motor Selection Chart...2. Glydea 35 DCT & Glydea 35 WT Glydea 60e DCT & Glydea 60e WT RTS...

User s Instruction Manual

Remote Control Electric Curtain Track User Manual

icleaner-120 User Manual

OCS Series. High Resolution Digital Crane Scale. User Guide

OCS-T High Resolution Digital Crane Scale

ABB AC500 Technical Help Sheet

HAT220A ATS CONTROLLER USERS MANUAL

CONTACT YOUR AUTHORISED STOCKIST

VFD - Mitsubishi. VFD Manuals. Mitsubishi D700 VFD Installation. Mitsubishi FR-D700 VFD User Manual. Mitsubishi D700 Parallel Braking Resistors

B-RAD Select USER MANUAL TABLE OF CONTENTS

HL (AZH) LIMIT SWITCHES

Gruppe 3 Beslag. Group 3 Components

Mitsubishi. VFD Manuals

V1.0. Showven Technologies Co.,Ltd.

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

JHYOCH MOTOR TECHNOLOGY CO.,LTD

Cisco Beacon Point Module

Kiropraktikk- benker. ErgoStyle FX ES2000 ErgoStyle Hylo

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

HL (AZH) Limit Switches

Installation Guide B-BOX Pro2.5 ~ 10.0

ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F

Volume Controls Model PJ 77 & 78

Emotron DCM Control Unit

VFD. Variable Frequency Drive

Driven Damped Harmonic Oscillations

MME/MOE Intelligent Electric Actuators About Ontrac

MINI BIKE-2016 MB 200 Set-up Instruction

PY600AC Sliding Gate Opener User Manual

B100S - Super Swing. Instruction Manual. Document number: B100S-C Release: V4.0 Date: May 08,2009

Tachometer (RPM Feedback) General

ABB i-bus KNX DG/S x DALI-Gateway Basic

EBikemarketplace. BAFANG BBS01/BBS02/BBSHD Installation Manual. Prepared for Customers of E-bike market place

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Honda Civic Hybrid Genuine Accessories

Temperature Controller TC5-2V8SA USER'S MANUAL. M rev. 03 K rev. 00

Installation Instructions

C600-LCD Instructions

VEHICLE CONTROLS Walk Away Auto Lock*

2020 Dual Tabber Operation Manual

Electric actuators type EA25-250

True Fail-Safe Technology and Precision Control for Reliable Shutdown

ADHESION/RELEASE TESTER

ASSEMBLY INSTRUCTIONS ZONE MODULE 2 1 THERMOSTAT DESCRIPTION POWER SUPPLY AIRZONE CONTROLLER

The RCS-6V kit. Page of Contents. 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3

I t n e t l e l l i l g i e g n e t n So S l o a l r a Ch C a h r a g r e g Co C n o t n r t o r l o l l e l r U e s r e s Man an al

EPAS Desktop Pro Software User Manual

PRODUCT SPECIFICATION. Stack Lights. Series.

Quick Starter Manual for PrusaM201

GUANGZHOU GENY ELECTRIC CO., LTD

224-EN WIRELESS CONTROLLER INSTALLATION & INTERFACE GUIDE. Guide No. 224-EN USING AS REPLACEMENT CONTROLLER

Beck. The differential pressure transmitter for air with IP65

Verktøybasert utsugssett

AKM 105, 115: Rotary actuator for ball valve

AC THOR or AC ELWA -E

INSTRUCTION MANUAL_1219_ENGLISH SUPER ELF X3. Operating Instructions for DORNIER looms. Robustness Reliability Quality Productivity Versatility

SNMP dedicated to ORVALDI Solar Infini

ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

MME/MOE Intelligent Electric Actuators About Ontrac

CSM Dispenser. User Manual. Dispenser Zone

CITIZEN. Portable vehicle weighing system Install handbook. Citizen Scale Inc., U.S.

ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

J1000. Compact Inverter Series.

APPLICATION NOTES. Industrial Wall Control (IWC10) (English) (IWC10)

Barrier Gate Manual. (DZX2.1 Control Board) (The third version) (Pictures for reference only, the product prevail in kind)

Installation Instructions

DC Controlled screwdrivers

NCE DCC TWIN. In addition to the NCE DCC TWIN, you will need:

Turny Evo. Autoadapt. Seat lift. Installation manual

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

Display. Specifications and Parameters of the Display. Appearance and Dimensions. Function Overview and Key Definitions. Materials and Dimensions

Quick Start Guide Armstrong Ave. Irvine, CA / Rev B

HL (AZH) Limit Switches

International A26 (2017)

Deans Switch Microfluidics

Wireless Radiator Valve

The motor starter on the power bus. Solutions for conveyor technology. Full speed ahead

ALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features

LCD S900 User Manual. The Latest Version 2014

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

ES 200 STANDARD ES 200 EASY PLUS

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

Ultrasonic Sensor U-B

Intelligent Solar Charge Controller. User's Manual. Please read this manual carefully before you use this product

Zonestar Installation Manual

AKM 105S, 115S: Rotary actuator with SAUTER Universal Technology (SUT) for ball valve

Transcription:

BUS Enabled Motorized curtain Parameters Electrical Parameters: Type Bus voltage Rated voltage Voltage range Working voltage Bus power Consumption Slave interface Rated power Rated torque Rated speed Rail belt speed MWM70B.12 (Master) MWM70S.12 (Slave) DC12-30V AC220V 50Hz AC220V±20% 50HZ DC24V(Master) DC12V(Slave) from Master 40mA/DC24V (Master) 33mA/DC12V (Slave) 6P network port 70W 1.0Nm 112rpm 16cm/s Overview HDL-MWM70B.12 It contains master and slave. It is the curtain controller, the master can be started by HDL Buspro. It supports manual mode and it has over load protection and over heat protection. Functions Communication interface HDL Buspro (Master) Environmental Conditions: Working temperature -5 ~45 Working Relative Humidity Up to 90% Storage Temperature -20 ~+60 Storage Relative Humidity Up to 93% Approved: CE RoHS Product Information: Dimensions 284 70 50(mm) The distance testing of the curtain Manual mode: long drag, short drag, drag no action Percentage control Control by HDL Buspro Supports HDL Buspro online upgrading Supports easy programming Built-in new generation clutch, precise planetary reduce, noise level 40dB Suitable for all small to medium-scale curtain applications, linear and arched, one-and two-side opening HDL Buspro Definition for Cable Weight Housing material Installation Protection degree Insulation degree 1554g(master) 1543g(slave) ABS, aluminum Wall Hanging IP41 E HDL Buspro DC24V COM DATA- DATA+ HDL Buspro/KNX Red Black White Yellow Important Buspro connection: Series connection (hand-inhand) Check the connection, avoid any mistake Horizontal pull is 8Kg, maximum load is 50Kg 1

www.hdlchina.com BUS Enabled Motorized curtain Dimensions and Wiring unlock latch locked Master MWM70B.12 Slave MWM70S.12 70 50 Motor terminal latch Motor terminal: Pull the latch to unlock direction, and then insert the motor terminal into the C-Driver Unit. Then, put the latch into the locked hole. 284 Master: HDL Buspro interface RJ11 6P network port, connect to the master and slave. It supplies the working voltage for slave. AC230V Power line, 1 meter. (Brown for L, Blue for N, Y/G for PE) LED indicate Function LED status Enter into the status Exit the status Working properly LED turns ON, 1 time/2s -- -- Modify the address of motor LED turns on Long press the button for 3s Testing for installation LED turns OFF, 1 time/2s Long press the button for 5s Easy programming LED Turns OFF, 2 times/2s Long press the button for 10s Notes: The above operations are carried out in normal work. Long press the button for 3s / no operation for 2minutes Long press the button for 5s / no operation for 20minutes Long press the button for 10s / no operation for 20minutes Safety Attention Do not make wrong connection on Buspro interface, it will damage the Buspro interface of this module. Never let liquids get into the module, it will damage this device. Ensure good ventilation Avoid contact with liquids and aggressive gases When you install the motor to the drive unit, please check and make sure that the latch is pushed into locked hole, otherwise the motor will fall down to cause personal injury and product damage When the motor is installed, please do not pull the curtain with too mush force, and do not put any additional weight on the rail, do not climb the curtain and do not hang anything on the curtain. 2

BUS Enabled Motorized curtain Step 1 Install rail and motor Install Effect Diagram Drive Unit Ceiling Bracket Rail Ceiling Bracket Drive Unit RJ11 Cable Master Fixed Hole Hook Unit Master Carrier Latch Roller Runner Slave RJ11 Cable The curtain hook mounting position: Hook Unit > Fixed hole > Roller Runner > Master Carrier and its handle. Master, Slave: The host is connected to the HDL Buspro port and AC220V, and it provides DC12V to the slave by the 6-core RJ11. The standard length of RJ11 wire is 1 meter. Ceiling Bracket s mounting distance: From both ends to the middle, it recommends to install a ceiling bracket and the distance is 600mm per (cannot exceed 600mm). In the middle rail, the distance between ceiling bracket can be slightly long, the recommended distance is 800mm. (Because the load in the ends is big, the mounting distance of ceiling bracket needs to be short, and the load in the middle rail is small, the distance of ceiling bracket can be slightly long) Step 2 Basic information When the curtain motor is working properly, keep pressing the button for 3s, the green indicator will turn on,now you can modify the address by HDL BUS Pro Setup Tool. Finish, keep pressing the button for 3s, will exit or if no-operation for 2min, will exit automatically. When you search the device, you can also modify the address by modify subnet ID, shown as left picture. 3

www.hdlchina.com BUS Enabled Motorized curtain Step 3 confirm motor running mode Motor running mode: Forward or backward. According to the windows, choose the motor running. Auto off when power on: If choose, when the motor power off and then power on again, the motor will close automatically. Step 4 Testing for installation (very important) Method one: (1)Keep pressing the button for 5S, the LED will flash 1 time/2s, the curtain enters into the testing mode. (2)The motor will measure moveable distance for the rail automatically (Open-close), when the motor stops, finish. (3)Short press the button, change the curtain status, if you press the button 1 time, the curtain will open, stop or close. (4)If it works properly, keep pressing the button for 5S, it will exit the testing mode. Method two: Click Start, the motor will measure moveable distance for the rail automatically, when it stops, finish. 4

BUS Enabled Motorized curtain Step 5 Drag mode Long drag No action Short drag Drag mode: long drag, short drag, no action. Long drag: Draw the curtain, the curtain will fully open or close automatically, the default distance is 20cm. Short drag: Draw the curtain, the distance will be more than the safe distance and less than the short drag distance, the curtain will open or close automatically,the default safe distance is 5cm,in order to avoid misoperation or curtain flap, you can set the safe distance. The default distance is 20cm. No action: Free mode, end-user can manually drag the curtain to any position freely. Note: Long drag and short drag are depend on your habit. When pulley is moving, the length should not less than 5cm, and no more than the half of total length. Step 6 Test Curtain switch: set the curtain status.( stop, open, close or percentage) 5

www.hdlchina.com BUS Enabled Motorized curtain Step 7 Test After testing, when the curtain opens or closes, casement is maybe extruded or the opening position is wrong (the curtain has stopped even if it is not fully opening.) Now, you should adjust the opening and closing position again by Adjust ON/OFF. Operation: Take the opening position as an example. At first, you should make sure the opening position, control the curtain to close to the opening position. And then, select Open (shown as above). If displays command error, means the opening position has confirmed. The closing position setting is same as the opening. General condition, the closing position needn t set. Step 8 DLP panel set- The wireless curtain motor can work with DLP panel, there are two ways for control: Setting 1: The button setting is shown as follows.(hdl-bus Pro Tool Setup) Operation: (Parameter 1 is 1(switch no.), parameter 2 is on, off, stop or percentage Long press the button, open or close the curtain, if loosen the button, it will stop running. If fully open or close, it will stop running automatically. Short press the button, it will be based on the percent to control the curtain Setting 2: The button setting is shown as follows.(hdl-bus Pro Tool Setup) Operation: short press the button, control the curtain open, close or stop. 6

BUS Enabled Motorized curtain Step 9 Easy programming mode Keep pressing the button for 10S,the LED will flash 2 times/2s. The device will enter into easy programming mode. Now, the panel will display programming, then keep pressing the shift buttons (button 9 and 10) of DLP switch at the same time, the panel will display external programming. In this mode, you can control the motor by PROG button. Keep pressing any panel button, it will cover the original target. Short press the button, it will add the motor control. Long press the button of motor for 10s, it can exit this status. If it is no action, it will exit automatically after 20min without operation. 7

www.hdlchina.com Anvisning for drift og vedlikehold Rengjøring: Produktet monteres normalt i veggbokser, sikringsskap eller tilsvarende beregnet for denne type elektrisk utstyr, og krever da ingen spesielle driftsrutiner for renhold. Ved renhold tørker man av produktet med en lett fuktet klut uten bruk av kjemikaler eller såpe. Fuktbestandighet: Produktet tilfredsstiller kravene for tetthet mot støv og vann når montert som beskrevet over og i henhold til IP-graden spesifisert under tekniske data. Vedlikehold, ettersyn og kontroll: Produktet skal normalt ikke åpnes. Ved ettersyn, sjekk at alle ledninger sitter godt, stram gjerne skruer som holder ledningene på plass, etter først å ha koblet fra strømmen. Påse at det ikke er skader på kabler eller ledningsisolasjon. Defekte eller skadede produkter skal skiftes umiddelbart. HMS Elektrisk utstyr: Installasjon og vedlikehold skal utføres av autorisert elektroinstallatør i samsvar med gjeldende lover og forskrifter. Verneutstyr: Verneutstyr ved installasjon/vedlikehold er ikke påkrevet. Brannslokking: I henhold til lokale forskrifter for brann i elektriske installasjoner. Miljø og avfallshåndtering Miljømerking: Produktet er godkjent i henhold til RoHS direktivet. Miljøpåvirkning: Produktet påvirker ikke miljøet negativt under normal drift. Elektromagnetisk utstråling og følsomhet for elektromagnetisk påvirkning er i henhold til gjeldende spesifikasjoner. Resirkulering: Produktet kan gjenbrukes, men det er ikke relevant med resirkulering av produktet. Avfall: Produktet skal deponeres i henhold til gjeldende regelverk for elektroniske produkter (PVC, halogenfrie materialer, gummi, etc.). EE-avfall kan levers tilbake vederlagsfritt til HDL Nordic eller en mottaksstasjon. Dokumentasjon og service Dokumentasjon: Ytterligere dokumentasjon for produktet, om relevant, finnes på www.hdlnordic.no. Produsent: HDL China, No. 24 Jianzhong Road, Tianhe Development Zone, Guangzhou, 510665 Kina Reparasjoner og service: Kontakt HDL Nordic AS, se informasjon nederst på siden.