Inductive conductivity meter

Similar documents
Inductive conductivity meter

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

INSERTION flowmeter with paddle wheel, ELEMENT design

Positive displacement flowmeter

Insertion magnetic inductive flowmeter

INSERTION flow sensor for continuous flow measurement

Paddle-wheel flow controller for On/Off control

Positive displacement batch controller

Digital ph transmitter

Digital ph transmitter

Paddle-wheel flow controller with optical principle for On/Off control

Positive displacement flowmeter for continuous flow measurement

Paddle-wheel flow controller for On/Off control

INSERTION Adaptor for analysis

Probe holders for analytical probes

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

Electrical position feedback for actuator sizes Ø mm

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

INSERTION Adapter/Fitting for analytical devices

2/2- and 3/2-way Ball Valve with pneumatic rotary actuator, plastic body, DN 10-50

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Inline Paddle Wheel Flow Switch

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

Pneumatic control unit for decentralized automation of ELEMENT process valves

2/2 way Angle-Seat Valve for medium up to C, DN15-50

2/2 or 3/2 way direct acting rocker solenoid valve

INLINE sensor-fitting with paddle wheel for flow measurement

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

Conductivity Measuring Sensor InduMax H CLS 52

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

3/2-way Solenoid Valve, direct-acting, NC or NO

INLINE fitting with paddle-wheel for flow measurement

FLOWX3 F3.60M.S Insertion Magmeter

2/2-way Globe Valve for media up to +180 C, DN

Turbotron // VTH15, VTM15, VTP15, VTI15

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

Type 8228 ELEMENT. Operating Instructions. Bedienungsanleitung Manuel d utilisation

2100 Turbine Flow Sensor

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

2/2-way Diaphragm Valve with stainless steel design, weld end or clamp connection, DN 8-25

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

2/2- and 3/2-way solenoid valve for aggressive fluids

2/2 and 3/2-way Flipper Solenoid Valve, with hermetic isolation of fluid

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

Type 8228 ELEMENT. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Direct-acting 2/2- or 3/2-way pivoted armature valve

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

2/2-way-Globe Valve with stainless steel design for media up to +180ºC, DN 13-50

2/2 or 3/2-way Miniature Rocker Solenoid Valve

Direct-acting 3/2 way plunger valve

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

Simple float switch TCL001/8181

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

2/2-way Globe Valve for media up to +180 C, DN

2/2-way Angle-Seat Control Valve with stainless steel design for media up to +185ºC, DN15-65

Type SE35. Quickstart. English. Flowmeter Flow Transmitter

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

SE 655 N-GEFFT0AM Digital Toroidal Conductivity Sensor

Indumax P CLS50. Technical Information. Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Flowmeter DFM

Operating Instructions (from serial number 3000)

Cable Plug acc. to DIN EN , Form A

2/2-way Compact Solenoid Valve, G 1/4 - G 1/2

Level Measurement Point level measurement - RF Capacitance switches

JUMO tecline Ci-S. Inductive conductivity and temperature sensor for general process engineering. Installation Instructions T94Z001K000

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Type S030. Operating Instructions. Symbols used. INLINE fitting. Bedienungsanleitung Manuel d'utilisation

Flowmeter for Gases. Type Type can be combined with... Type 8802-YG Process control valve. Type 5281 Solenoid valve

Electronic Pressure Switches

2/2-way Angle Seat Valve, manually operated, for media up to +180 C

Diaphragm valve MV 309

JUMO MIDAS S05 Pressure transmitter Type

Level Measurement Point level measurement - RF Capacitance switches

Index Flow Sensors FLOWX3 F3.00 Paddlewheel Flow Sensor page 2 FLOWX3 F111 Hot Tap Flow Sensor page 18 FLOWX3 F3.60M Insertion Magmeter page 24 FLOWX3

2/2 or 3/2 way direct acting rocker solenoid valve

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Types 8025 / Operating Instructions. Bedienungsanleitung Manuel d utilisation. Flowmeter Durchflussmessgerät Débitmètre

Flow measurement FlexFlow PF20H Hygienic flow sensor

2/2-way Globe Control Valve with stainless steel design for media up to +185ºC, DN

Flow Transmitter / Switch OMNI-RR..32

2/2-way Solenoid Valve with servo diaphragm

JUMO ecotrans Lf 01/02

2/2-way Globe Control Valve, threaded port connection, DN 10-65

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

better measurement Simply a question of

Signet 7000/7001 Vortex Flow Sensors * *

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Pneumatically operated zero dead volume T-Valve CLASSIC

2/2-way Angle-Seat Valve for media up to +180 C, threaded port connection, DN 13-65

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Type 8222 ELEMENT. Operating Instructions. Bedienungsanleitung Manuel d utilisation. Conductivity meter Leitfähigkeits-Messgerät Conductivimètre

INLINE fitting with paddle-wheel for flow measurement

Transcription:

Inductive conductivity meter Type 8228 can be combined with... Configurable outputs: up to 2 transistor and up to 2 analog 4... 20 ma outputs Removable backlighted display Simulation of process values Diagnostic functions Sensor-versions available with PEEK, PVDF or PP Type S020 INSERTION fitting Type 8802-DF Diaphragm valve with control unit Type 2030 On/Off Diaphragm valve Type 8619 multicell Transmitter/Controller PLC Bürkert s analytical meter Type 8228 is designed for measuring the conductivity in industrial and water treatment applications (i.e. aggressive fluids, CIP,...). The conductivity meter consists of a sensor, plugged-in and pined to an enclosure with cover, containing the transmitter module and a removable display. The sensor component consists of a pair of magnetic coils in a PP, PVDF or PEEK holder. The cell constant is an average value over the whole measuring range. It can be re-adjusted depending on application. The integrated temperature probe (without direct contact to the fluid) for automatic compensation is a standard feature in the conductivity sensor holder. The conductivity meter can operate independent of the display but it will be required for programming the device (i.e. selection of sensor cell constant, language, measuring range, engineering units, calibration...) and also for visualizing continuously the measured and processed data. The device Type 8228 is available: - with two fully configurable outputs: one transistor and one 3-wire 4... 20 ma current outputs - with four fully configurable outputs: two transistor and two 3-wire 4... 20 ma current outputs. The electronics of Type 8228 converts the measured signal, displays different values in different physical units (if display mounted) and computes the output signals, which are provided via one or two M12 fixed connectors. Complete device data (Fitting + conductivity meter) Pipe diameter DN15 to 400 Conductivity measurement Measuring range Resolution Measurement deviation ( measurement bias as defined in the standard JCGM 200:2012) Linearity Repeatability Response time t90 Temperature measurement Measuring range Resolution Measuring uncertainty Response time t90 Temperature compensation Medium temperature with conductivity sensor in PVDF PP PEEK 100 S/cm...2 S/cm 0.1 S/cm ±(2% of the measured value + 5 S/cm) ±2% ±(0.2% of the measured value + 2 S/cm) from 3 s (without filter) to 40 s (with slow filter) -40 to +150 C (-40 to 302 F) 0.1 C (0.18 F) ±1 C (1.8 F) < 280 s (without filter) - none or - according to a predefined graph (NaCl, NaOH, HNO 3 or H 2 SO 4 ) or - according to a graph defined especially for your process -15 to +100 C (5 to 212 F) 0 to +80 C (32 to 176 F) -15 to 130 C (5 to 266 F) Temperature limits may depend on the material the S020 fitting used is made of. Refer to the relevant data sheet or instruction manual and the pressure/temperature diagram of the fluid on page 3. If the temperature ranges given for the device and the fitting are different, use the most restrictive range. Fluid pressure max with conductivity sensor in PVDF, PP PEEK PN6 (87 PSI) PN10 (145 PSI) Pressure limits may depend on the material the S020 fitting used is made of. Refer to the relevant data sheet or instruction manual and the pressure/temperature diagram of the fluid on page 3. If the temperature ranges given for the device and the fitting are different, use the most restrictive range. www.burkert.com p. 1/8

Environment Ambient temperature Relative humidity Height above see level -10 to +60 C (14 to 140 F) (operating and storage) 85%, without condensation Max. 2000 m General data Compatibility Materials Housing / Cover Seal / Screws Fixed connector holder M12 fixed connector Display / Navigation key Nut Wetted part materials Sensor holder Seal Temperature sensor Display (accessories) Electrical connections 2 outputs meter (3-wire) 4 outputs meter (3-wire) Connection cable Any pipe which are fitted out with Bürkert INSERTION Fitting S020 (see corresponding data sheet) See materials view, on next page Stainless steel 1.4561, PPS / PC EPDM / Stainless steel Stainless steel (316L) Brass nickel plated PC / PBT PC PP, PVDF or PEEK FKM (standard) or EPDM (option) Integrated in the sensor Grey dot matrix 128x64 with backlighting 1x 5-pin M12 male fixed connector, 1x 5-pin M12 male + 1x 5-pin M12 female fixed connectors Shielded cable, ø 3 to 6.5 mm; max. 0.75 mm 2 cross section Electrical data Supply voltage Current consumption with sensor Reversed polarity of DC Voltage peak Short circuit Output Transistor Current (3-wire) Uncertainty of the output value Response time (10% - 90%) 12-36 V DC, ±10% oscillation rate, filtered and regulated, SELV (safety extra low voltage) circuit with a non dangerous energy level 25 ma (at 12 V DC and without the consumption of the 4... 20 ma output) Protected Protected Protected Polarized, galvanically insulated configurable through wiring and through parameterizing as sourcing (PNP) or sinking (NPN) output NPN: 1-36 V DC, max. 700 ma (or 500 ma max. per transistor if both transistor outputs are wired) output PNP: V+ supply voltage, max. 700 ma (or 500 ma max. per transistor if both transistor outputs are wired) 4... 20 ma configurable through wiring and through parameterizing as sourcing or sinking, 22 ma to indicate a fault (can be parametered) max. loop impedance: 1100 at 36 V DC; 610 at 24 V DC; 100 at 12 V DC 1% of the full scale 150 ms (default value) Standards, directives and approvals Protection class acc. to EN 60529 Standard and directives EMC Pressure Vibration / Shock Approvals for US and Canada IP65 and IP67 with M12 connectors plugged in and tightened and electronic module cover fully screwed down EN 61000-6-2, EN 61000-6-3 and Annex1, EN 61326-1-7 (Table 2) Complying with article 3 of 3 from 97/23/CE directive.* EN 60068-2-6 / EN 60068-2-27 61010-1 + CAN/CSA-C22 No.61010-1 * For the 97/23/CE pressure directive, the device can only be used under following conditions (depend on max. pressure, pipe diameter and fluid). Type of fluid Fluid group 1, 1.3.a Fluid group 2, 1.3.a Fluid group 1, 1.3.b Fluid group 2, 1.3.b Conditions Forbidden DN 32, or DN > 32 and PN*DN 1000 PN*DN 2000 DN 200 or PN 10 Specific technical data of UL-recognized products for US and Canada Intended for an inner pollution Installation category Grade of pollution 2, according to EN61010-1 Category I, according to UL61010-1 p. 2/8

Materials view PC Nickel-plated brass EPDM PPS Stainless steel EPDM PPS PC FKM (standard) EPDM (option) PP or PVDF or PEEK Pressure/temperature chart P (bar) 12 11 10 9 8 7 6 5 4 3 2 1 0 A PEEK PVDF PP -20 0 +20 +40 +60 +80 +100 +120 +140 T ( C) A: Application range for complete device (conductivity meter with either PP, PVDF or PEEK sensor inserted into a Stainless steel S020 fitting) Principle of operation The conductivity is defined as the ability of a solution to conduct electrical current. The load carriers are ions (E.G. dissolved salt or acids). In order to measure conductivity, an AC voltage source is connected to the primary magnetic coil. The magnetic field induced generates a current in the secondary magnetic coil. The intensity of this induced current is a direct function of the conductivity of the solution. Up to two 4... 20 ma standard signal are available as output signals, proportional to the conductivity and/or to the temperature of the fluid. The conductivity meter is a three-wire device and requires a power supply of 12 V DC up to 36 V DC. p. 3/8

In-line installation 8228 The 8228 conductivity meter can be installed into any Bürkert INSERTION fitting (S020),, by just fixing the main nut. Select and install the required fitting onto the pipe, according to specific requirements of the sensor and fitting material (temperature and pressure). Then, carefully install the device on the fitting, and tighten with the nut. It can be installed in any position. In order to get reliable measurement air bubbles must be avoided. Please ensure that the mounting location provides a continuous and complete immersion of the sensor in the flow stream. Tank without mixing device Tank with mixing device The device must be protected from constant heat radiation and other environmental influences, such as direct exposure to sunlight. Combining the S020 with a measuring device for conductivity measurement DN06 DN15 DN32 DN50 DN65 DN350 DN400 Available S020 fittings T-fitting for measuring device with G2 c onnection Welding socket Fusion spigot Conductivity measuring device 8228 *** *** Only use plastic fitting in analytical version with true union acc. to DIN 8063 (PVC), to DIN 16962 (PP) or to ISO 10931 (PVDF) p. 4/8

Dimensions [mm] of conductivity meter Type 8228 97 70 65 246 154 168 26,5 H Orifice T-Fitting Plastic spigot Metal spigot 15 233* 20 233* 25 233* 32 233 40 237 50 243 238 65 243 264** 244 80 264** 249 100 264** 259 125 299 270 150 306 281 200 327 302 250 345 362 300 357 381 350 370 393 400 385 * Only use plastic fitting in analytical version with true union acc. to DIN 8063 (PVC), to DIN 16962 (PP) or to ISO 10931 (PVDF) ** use analytical fusion spigot (Item no. 418652, 418660 or 418644 in PP, PVDF or PE) for orifice DN65-DN100 H p. 5/8

Ordering information for compact conductivity meter Type 8228 A complete compact conductivity meter Type 8228 consists of a compact conductivity meter Type 8228, a removable display/ configuration module and a Bürkert INSERTION adaptor Type S020. The following information is necessary for the selection of a complete device: Item no. of the desired conductivity meter Type 8228 available with or without display/configuration module (see ordering chart on p. 7) Item no. of the selected INSERTION fitting Type S020 (see separate data sheet) Attention! When you order devices without display/configuration module, please take care that you also order at least one display/configuration module for the operation. Order no. of the removable display/configuration module, see ordering chart on p. 7 When you click on the orange box More info. below, you will come to our website for the resp. product where you can download the data sheet. Example Compact conductivity meter Type 8228 + Removable display/configuration module (included or separately available) Complete device for conductivity measurement Type 8228 INSERTION fitting Type S020 Fitting (example only) p. 6/8

Ordering chart for compact conductivity meter Type 8228 Conductivity meter Type 8228 Specifications Voltage supply Output Sensor holder material Sensor seal material* Electrical connection UL Approvals Item no.** without display Item no.** with display Compact conductivity meter 12-36 V DC 1 x transistor NPN/PNP + 1 x 4... 20 ma PP FKM 5-pin M12 male fixed connector PVDF FKM 5-pin M12 male fixed connector No 565 601 566 601 565 611 566 611 No 565 603 566 603 565 613 566 613 PEEK FKM 5-pin M12 male fixed connector No 565 605 566 605 565 615 566 615 2 x transistors NPN/PNP + 2 x 4... 20 ma PP FKM 5-pin M12 male and 5-pin M12 female fixed connectors PVDF FKM 5-pin M12 male and 5-pin M12 female fixed connectors No 565 602 566 602 565 612 566 612 No 565 604 566 604 565 614 566 614 PEEK FKM 5-pin M12 male and 5-pin M12 female fixed connectors No 565 606 566 606 565 616 566 616 * FKM seal in standard; 1 set including a green FKM and a black EPDM seals for the sensor, is supplied with each conductivity meter ** Transparent cover in standard Ordering chart for accessories Description Item no. Removable display/configuration module (with instruction sheet) 559 168 Black blank cover with EPDM seal 560 948 Transparent cover with EPDM seal (standard) 561 843 Ring 619 205 PC - nut 619 204 Calibration solution, 300 ml, 706 S/cm 440 018 Calibration solution, 300 ml, 1413 S/cm 440 019 Calibration solution, 500 ml, 12880 S/cm 565 741 Calibration solution, 300 ml, 100 ms/cm 440 020 5-pin M12 female straight cable plug with plastic threaded locking ring, to be wired 917 116 5-pin M12 male straight cable plug with plastic threaded locking ring, to be wired 560 946 5-pin M12 female straight cable plug moulded on cable (2 m, shielded) 438 680 5-pin M12 male straight cable plug moulded on cable (2 m, shielded) 559 177 p. 7/8

Interconnection possibilities with other Bürkert devices Type 8802-DF - Diaphragm valve with control unit PLC Type 8611 - Single channel controller Type 8619 - multicell Transmitter/Controller Type 8228 - Inductive conductivity meter Type S020 - Metal or plastic for measuring device with G2 connection To find your nearest Bürkert office, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. Subject to alteration. Christian Bürkert GmbH & Co. KG 1403/1_EU-en_00895254 p. 8/8