KILOVOLT POWER SUPPLY

Similar documents
ROTARY MOTION SENSOR FOR ULI

Instruction Sheet. CFRD Series. High CFM Split Rear Doors

Rotary Motion Sensor

SMP3CTX Series Power Supply/Charger

- 4 amp. - 4 amp. - Sixteen (16) Fuse Protected - Sixteen (16) PTC Protected

COMPUTER-BASED THERMAL EXPANSION APPARATUS

- 4 amp (100VA). - 4 amp (100VA). - Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.

DSP led gaming monitor USER MANUAL

Rack Mount Power Supplies

Model MC4 MEDIA CONTROL by OWI

Mini Hi-Fi System *MFL * SIMPLE MANUAL

- 4 amp (100VA). - 4 amp (100VA). - Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.

UL Listed CCTV Power Supplies. - 4 amp. - 4 amp. - Eight (8) Fuse Protected - Eight (8) PTC Protected

Fiber Optic Illuminator. Model 21AC Model 21DC

CCTV Rack Mount Power Supplies

CCTV Rack Mount Power Supplies

owner s manual IsoCenter-NS Series Rackmount Shielded Isolation Transformer and Power Distribution Center

PID-1500 THERMOELECTRIC & RESISTIVE HEATER TEMPERATURE CONTROLLER INSTRUCTION MANUAL

CANARY AUDIO. Vacuum Tube Preamplifier CA-800 OWNER S MANUAL. Handcrafted in California MADE IN USA

Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply Product Code: NM-CDPS. User Manual

INSTALLATION MANUAL. Recessed In-Ceiling Motorized Projection Screen

DC CCTV Power Supplies Installation Guide

CANARY AUDIO CA-400. Vacuum Tube MM/MC Phono Preamplifier OWNER S MANUAL. Handcrafted in California MADE IN USA

Owner s Manual. OutCast 1.2. The Ultimate Outdoor Speaker System

4 amp (100VA). - 4 amp (100VA). - Four (4) Fuse Protected - Four (4) PTC Protected

02OWNER S MANUAL 06 TROUBLESHOOTING 08LIMITED WARRANTY

REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND OPERATOR'S MANUAL.

FC-27W 7 dome housing. Installation Instructions

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

CURRENT BALANCE CAUTION

MANSON ENGINEERING INDUSTRIAL LTD. SERVICE MANUAL FOR SPS-9400

Model Volt-Amp-Wattmeter INSTRUCTION MANUAL

Switching DC Power Supply

CHARGING UNIT DEM 313

OPERATIONS AND APPLICATIONS MANUAL MODEL NUMBER PM6. 6 KV DC HIGH POTENTIAL TESTER WITH MEGOHMMETER Version 2.0

4-Hour. Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

4-SIDED BASKETBALL SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

Service Manual 6301B

MANSON ENGINEERING INDUSTRIAL LTD. SERVICE MANUAL FOR SPS-9400

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

MicroPod Sub User manual / Bedienungsanleitung / Manual del Usario

Cordless Make Up Mirror WITH ILLUMINATED 1X AND 10X MAGNIFICATION PLUS NIGHT LIGHT

NEDG SERIES DUAL E-BEAM GUN SWITCHING POWER SUPPLIES

Duo Massager. Cordless Shiatsu & Percussion Massager

For technical questions and replacement parts, please call

28BSST POWER AMPLIFIER OWNER S MANUAL UPDATED

PM - Projector Mount System

Model 1672, 1673 Triple Output Power Supply

Twelve Unit Rapid Charger

A100 Class D 100W Subwoofer Amplifier. User Guide VOLUME POWER BOOST

MODEL 6120 SERIES Hydraulic Pumping Unit (HPU) W/Logo

At-FST Series I N S TA L L AT I O N A N D O P E R AT I N G I N S T R U C T I O N S W W W. A I G I S M E C H. C O M

INSTRUCTION MANUAL M110A Fax: (503)

MODEL 611x SERIES Sliding Gate Barriers Hydraulic Pumping Unit (HPU)

TESCO THE EASTERN SPECIALTY COMPANY Date: 05/04/15 Canal Street and Jefferson Avenue Bristol, PA 19007

Cable Length Meter INSTRUCTION MANUAL

ECE 480 Design Team 3: Designing Low Voltage, Low Current Battery Chargers

GLYCOL SYSTEM MONITOR (GSM)

UNIVERSAL VOLTAGE REGULATOR Manufactured in the USA by

INSTRUCTION MANUAL DM5B Fax: (503)

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

Model 556 High Voltage Power Supply Operating and Service Manual

Mechanical Spiral Sensor

LIGHTNING PROTECTION UNIT (LPU)

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

4070 Subwoofer Owners' Manual

Soothes every aching muscle in its path.

II DISTRIBUTION & SUBSTATION TYPE C

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:

The Da-Lite Difference.

EV-2051-M Electric Motor. Operation and Maintenance Manual

ELECTRO-MECH SCOREBOARD CO.

Model 1900, 1901, 1902 Switching DC Power Supply

RP-4000 Reserve Power Control

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY

IEDA524-H / IEDA520DTB DIGITAL MICROPHONE STATION. Installation Instructions

Model 1693, 1694 Switching DC Power Supply

Applications DC Motors Stepping and Servos Solenoid Valves Relays Lamps and Signal Systems Input to On-Board Regulators Some Floppy Disc Drives.

DUAL 12 Volt-10 Amp AUTOMATIC BATTERY CHARGER

H-88BK H-88BG H-88GR H-88GRDK. Two Preloaded 8.8" Wide Universal Replacement Headrest Monitors Package AUX OWNER S MANUAL

OPERATION and MAINTENANCE INSTRUCTION MANUAL

PRO Dimmer INSTRUCTION MANUAL

Filtered PWM Speed Control for Permanent Magnet DC Motors

The Da-Lite Difference.

The Da-Lite Difference.

Transceiver Voltage Conditioner

Model G14SD Vapor Management System

MV Series Motors Operation & Parts Manual

TS69 TS65 TS55 TS45 TS5768 TS SERIES INSTALLATION/OWNER'S MANUAL

CF-10 Option Operating Instructions

2100 Childbearing Bed OPERATIONS MANUAL. For Parts or Technical Assistance

Rental Industry Safety Tester Safe Check 5s

OPERATION and MAINTENANCE INSTRUCTION MANUAL. AA-98 AirPac II Compressor 110V

Westell FUSE PANEL. Technical Practice N Position Type VDC Floating

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

Go Power! Manual. GP-SW1500 Inverter. Table of Contents. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4

PLATINUM Series CAN WIDEBAND CONTROLLER WBC 1 & WBC 2 QUICK START GUIDE (HT & HT059980) Version 4

Transcription:

Instruction Sheet for the PASCO Model SF-9586 KILOVOLT POWER SUPPLY 012-02815D 1/95 $1.00 SF-9586 KILOVOLT POWER SUPPLY ON kv HIGH VOLTAGE ADJUST OFF 6 KV 6.3 VAC CAUTION! HIGH VOLTAGE 3 KV 3 KV Introduction The PASCO scientific Model SF-9586 Kilovolt Power Supply provides regulated DC power from 0 to 6 kilovolts. The 6 kilovolt output is center tapped, providing outputs of 0 to +/-3 kilovolts. In addition, a pair of output jacks provides 6.3 volts of AC power, which is commonly used as filament power in electron tube experiments. IMPORTANT: ➀ The 6.3 VAC output is unregulated. If you are using it to heat the filament in a vacuum tube, we recommend that you use a current limiting resistor (1-2 Ω, variable) in series. Measure the voltage at the filament and adjust the resistance to get the required voltage. ➁ For an accurate meter reading, always use the left and right output jacks (6 kv). Use the middle jack only when your application requires a centertapped voltage. (The center tap will be the midpoint of the output voltage only if equal currents are drawn from the ±3 kv output jacks.) To Use the Power Supply: ➀ Plug the power cord into a well-grounded 107-128 VAC, 60 Hz or 198-242 VAC, 50 Hz outlet. (See label on rear of unit). ➁ Connect the appropriate output terminals of the power supply to the circuit. (Connecting wires are not provided with the supply.) ➂ Turn the HIGH VOLTAGE ADJUST knob fully counterclockwise. ➃ Flip the ON/OFF switch on the front panel to ON. The switch will light to show that the power is on. ➄ Turn the HIGH VOLTAGE ADJUST knob to obtain the desired output. The meter will show the voltage between the 6 KV output terminals. CAUTION! HIGH VOLTAGE The power supply uses two 390 KΩ resistors which limit the output current to approximately 3mA. Nevertheless: * Always work with a partner. * Wear rubber soled shoes. * Work with one hand only. Keep the other hand in your pocket or behind your back. 1994 PASCO scientific This instruction sheet edited by: Tom Reineking 10101 Foothills Blvd. P.O. Box 619011 Roseville, CA 95678-9011 USA Phone (916) 786-3800 FAX (916) 786-8905 email: techsupp@pasco.com better ways to teach physics

Kilovolt Power Supply 012-02815D Specifications DC Output: Voltage: Continuously variable 0 to 6 kv differential (no load) 0 to 3 kv and/or 0 to -3 kv (no load) each side, relative to center-tap. Current: 50 µa at 6 kv differential (3 kv each side) Short-circuit current: approx. 3 ma Ripple: Less than 1% Line Regulation: Less than 1% variation in dc out put voltage for a 10% variation in line voltage. Grounding: Any one terminal may be grounded. Short-circuit protection: continuous AC Output: Voltage: 6.3 VAC nominal, unregulated Current: at least 2 A at 6.3 V Fuse: 630 ma, (115 VAC units) 315 ma, (220/240 VAC units) CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO PREVENT THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER ON UNIT. NO USER SERVICE- ABLE PARTS INSIDE. REFER SERVICING TO QUALI- FIED SERVICE PERSONNEL. The lightning flash with arrowhead, within an equilateral triangle, is intended to alert the user of the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. Equipment Return Should this product have to be returned to PASCO scientific, for whatever reason, notify PASCO scientific by letter or phone BEFORE returning the product. Upon notification, the return authorization and shipping instructions will be promptly issued. NOTE: NO EQUIPMENT WILL BE ACCEPTED FOR RETURN WITHOUT AN AUTHORIZATION. When returning equipment for repair, the units must be packed properly. Carriers will not accept responsibility for damage caused by improper packing. Address: PASCO scientific 10101 Foothills Blvd. P.O. Box 619011 Roseville, CA 95678-9011 Phone: (916) 786-3800 FAX: (916) 786-8905 Limited Warranty PASCO scientific warrants this product to be free from defects in materials and workmanship for a period of one year from the date of shipment to the customer. PASCO will repair or replace, at its option, any part of the product which is deemed to be defective in material or workmanship. This warranty does not cover damage to the product caused by abuse or improper use. Determination of whether a product failure is the result of a manufacturing defect or improper use by the customer shall be made solely by PASCO scientific. Responsibility for the return of equipment for warranty repair belongs to the customer. Equipment must be properly packed to prevent damage and shipped postage or freight prepaid. (Damage caused by improper packing of the equipment for return shipment will not be covered by the warranty.) Shipping costs for returning the equipment, after repair, will be paid by PASCO scientific. Other PASCO Power Supplies PASCO scientific offers a variety of rugged, reliable power supplies. From low-voltage, fixed-output supplies to this 6KV DC supply, all PASCO power supplies are easy to use, ruggedly built, and short circuit protected for long life in the student lab. For information, check our catalog or call toll-free 1-800-772-8700. 2

012-02815D Kilovolt Power Supply Parts List REFERENCE PART RATING C1,C2,C3,C4,C5,C6,C7, C8,C9,C11,C12,C13,C14, C15,C16,C17,C18,C19 1N4007 1000V C10 1500uF 50V C20,C28,C30,C36 100uF 40V C21,C33 0.47uF C22,C34 10nF 63V C23,C24,C25,C26,C27, C29,C31,C32 0.1uF 63V C35 220nF 63V C201,C202,C203, C204,C205,C206 0.22uF 1000V D1,D2,D3,D4,D5,D6, D7,D8,D9,D10,D11, D12,D13,D14,D15,D16 D17,D18 GP02 1000V D19 2W04M D20,D21,D201,D202 1N4148 F1 T630/250 J1 777 M1 100ua KF86b P1A,P1B 10K POT Q1,Q4 BC557B Q2,Q6 BD788 Q3,Q5 BD243C R4,R41 100R R7,R40 3K3 R8 12K4 1% R10,R31 22K R13,R15 47K R1,R36 2K43 1% R5,R42 22R 2W R6,R43 82R R9,R34 6K8 R11,R29 82K R12,R14,R47,R48,R49 10K R16,R19,R24,R28 10M R17,R26 8K2 R18,R32 1K R20,R33 75K 1% R21,R30 4K7 R23 2K2 R27 1M R2 274R 1% R22,R39 270R R3,R37 470R R25,R50 820R 5W R35 560R 1% R38 68K R44,R45 2K2 SIL R46 47K NTC R201,R202,R203,R204, R205,R206,R207,R208 390K R209,R211 15M R210,R212 12M SW1 C5403FQ TF1,TF2 14445 TF3 16566 TF4 16567 TR1,TR2,TR201 10K TRIM TR3,TR5 4K7 TRIM TR4,TR6 2K2 TRIM TR7,TR8 47K TRIM U1,U6 NE555 U2,U4 LM324 U3,U7,U8 LM317 U5 LM317L 3

Kilovolt Power Supply 012-02815D Layout Component Layout (1 of 2) 4

012-02815D Kilovolt Power Supply Component Layout (2 of 2) 5

Kilovolt Power Supply 012-02815D Schematic Schematic 6

012-02815D Kilovolt Power Supply Schematic continued 7

Kilovolt Power Supply 012-02815D Technical Support Feed-Back If you have any comments about this product or this manual please let us know. If you have any suggestions on alternate experiments or find a problem in the manual please tell us. PASCO appreciates any customer feed-back. Your input helps us evaluate and improve our product. To Reach PASCO For Technical Support call us at 1-800-772-8700 (toll-free within the U.S., (916) 786-3800, or email: techsupp@pasco.com Contacting Technical Support Before you call the PASCO Technical Support staff it would be helpful to prepare the following information: If your problem is computer/software related, note: Title and Revision Date of software. Type of Computer (Make, Model, Speed). Type of external Cables/Peripherals. If your problem is with the PASCO apparatus, note: Title and Model number (usually listed on the label). Approximate age of apparatus. A detailed description of the problem/sequence of events. (In case you can't call PASCO right away, you won't lose valuable data.) If possible, have the apparatus within reach when calling. This makes descriptions of individual parts much easier. If your problem relates to the instruction manual, note: Part number and Revision (listed by month and year on the front cover). Have the manual at hand to discuss your questions. 8