BAAS Component AS 2017 Rev. 01 INSTALLATION, OPERATION AND MAINTENANCE MANUAL - DAMPERS

Similar documents
Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life!

PMV P36C AND P41C POSITIONERS ACTUATORS

Installation and operating manual

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a Universal in-out filter.

Installation, Operation and Maintenance Manual

Installation, Operation, and Maintenance Instructions

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

Installation, Operation & Maintenance Manual

Pneumatic Actuator Durastroke Series 2000 Installation & Maintenance Instructions

Installation, Operation and Maintenance Manual

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an in-out filter.

Powers TM Controls Three-way Electro-pneumatic (EP) Valve Model 2

MOTORIZED VOLUME DAMPER

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter.

Introduction to Johnson Controls Dampers

Heating and Gas Installations - December 2014

Installation, Operation and Maintenance Manual

INSTALLATION, OPERATION & MAINTENANCE MANUAL. 0.- Description Handling Installation Actuators Maintenance...

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

J Flow Controls Model Numbering

CompoSeal butterfly valves, wafer style Installation & Maintenance Instructions

Butterfly valves Figure 56 Installation & Maintenance Instructions

Series Single seated top guided control valve. Preventive maintenance. Overhauling procedure. Wörth am Main SERVICE NOTE. Control Valve Division

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL RBK FRP FAN

FTM-L SERIES SINGLE OR TWIN DIRECT STEAM MIXER KETTLE COMPLETE WITH HYDRAULIC POWER TILT BRIDGE PARTS AND SERVICE MANUAL

When installing the screwed end, socket weld & flanged end valves the following respective procedures shall be followed for better performance.

Mounting and Operating Instructions EB 8227 EN. Pneumatic Control Valve Type 3331/BR 31a Special version Type 3331/3278. Type 3331 Butterfly Valve

QFS Oil Mist & Cutting Fluid

Gastight Rectangular Shut-Off Damper, Type GD-R

RIGHT LEFT. Fig. 9. Fig. 10. Page.33

VOLUME CONTROL / REGULATING DAMPERS

ONYX VALVE CO MODEL DEC Installation & Maintenance

582 Series. Instruction Manual. Two-Door Wafer Check Valve N-582 (R-08/2016)

Installation, Operation And Maintenance Manual. Manual. For the 400 Series. ABZolute Seal. High Performance Butterfly Valve "Double Offset"

The correct position of the bonding surface is: In the middle of the tire inner layer. In the area of the DOT stamp.

HL Series Inline Lever Start Auto Shut Off SEE LAST PAGE FOR IMPORTANT INFORMATION

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a threaded filter.

Installation of the DD13,DD15, and DD16 Cylinder Head February Installation of the DD13 Cylinder Head

Type N550 Snappy Joe Emergency Shutoff Valves

Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion

Pneumatic Actuator Durastroke Series Installation & Maintenance Instructions

SPECIAL TOOLS BULLETIN

DeZURIK 2 20" BOS BUTTERFLY VALVES

Automatic Roof Door Vents

Keystone Butterfly valves ParaSeal Installation and maintenance instructions

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

PRODUCT INSTALLATION GUIDE

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

MANUAL INSTALLATION. Venturi FX. VFX Series. v100 Issue Date: 11/22/ Price Industries Limited. All rights reserved.

Competence in Functional Safety MANUAL. principle and typical applications

Operating and installation instructions

Installation Instructions

Model DF233 Control Valve

75500MAX Series and 75500MAXM Series

Table of Contents General Information Safety Message Classifi cation...2 Safety Notes...3 Terminology...4 Coupler Lifting Lug...

SECTION HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY. A. Section Includes:

PH1 AIR INTAKE EMERGENCY SHUT-OFF VALVE PULL CABLE ACTUATION.

TC Series Cooling Systems

Installation, Operation and Maintenance Manual

Drilling Series SC Series Cellular Suction Stabilizers Instruction, Operating & Maintenance Manual

Installation, Operation and Maintenance Manual

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

MERIDIAN, 2 or 3 PIECE, TRUNNION MOUNTED BALL VALVES

PNEUMATIC CONTROL SYSTEMS DESIGN AND CONSTRUCTION STANDARD PART 1 - GENERAL. A. Codes and Standards that are Standard at the University:

Installation, Operation and Maintenance Manual for the HE Series

Installation Instructions. Applications. Installation. Part No , Rev. Issued May 9, 2011

Rzr Heater System Part #

INDEX. Chapter1 6. air master. Volume Control Dampers

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

TITAN FLOW CONTROL, INC.

Nominal sizes: DN 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150 Pressure rating: PN 16. Product No. Nominal size Body connection

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual

Alliance Towel Dispensing System. Operation Manual

Page 1 of 7 AUTOMOTIVE GLASS. Windshield Repair Guidelines Background. Limitations of Repairs. Guidelines. Damage Assessment. When not to repair

JT SERIES ANGLE STEM TANK BOTTOM BALL VALVE DN25 DN150. Installation, Maintenance and Operating Instructions

Storage, operating and maintenance instructions for AZ plug valves and Standard valves

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

Flow Control & Pressure Reducing Valve with Hydraulic Control (Sizes 3''- 12"; DN80-DN300)

Installation, Operation, and Maintenance Manual. Automatic Fire Damper

Sub Section Title Page No.

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard C**H Series 2 & 2½ Ton 2-Stage Wall Mount Heat Pumps

Operating & Maintenance Manual For Steam Conditioning Valve

BRACKETT AERO FILTERS, INC.

Water in Fuel Sensor Kit

Type N550 Emergency Shutoff Valves. Instruction Manual. Type N550 Emergency Shutoff Valves. Introduction. Specifications. Scope of Manual.

BRACKETT AERO FILTERS, INC.

Product Manual MNX10015 / REV B MODEL SB142, SB242. Dual Output Series Switch Boxes

Mounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator

INSTALLATION, OPERATION & MAINTENANCE MANUAL Description Handling Installation Actuators...

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type NAK. Gas-tight shut-off damper with pneumatic actuator

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

OTTO HYDRAULICS GmbH & Co KG SYSTEME UND KOMPONENTEN FÜR ÖLHYDRAULISCHE ANTRIEBE UND STEUERUNGEN SIEMENSSTRASSE 12/ FRIEDRICHSHAFEN

PNEUMATIC SLIDING VALVE

SR01 Steering, Gearbox

BENNETT CNG DISPENSER MAINTENANCE SCHEDULE

Transcription:

BAAS Component AS 2017 Rev. 01 INSTALLATION, OPERATION AND MAINTENANCE MANUAL - DAMPERS 1

List of Contents 1 INSTALLATION, OPERATION AND MAINTENANCE MANUAL... 3 1.1 GENERAL INTRODUCTION... 3 1.2 SCOPE... 3 1.3 HEALTH AND SAFETY INFORMATION... 3 1.3.1 Requirements... 3 1.3.2 Warning all dampers... 4 2 PNEUMATIC SHUT-OFF DAMPERS... 4 2.1 General information... 4 2.1.1 Connection to ductwork... 4 2.1.2 Air connection... 4 2.1.3 Electric connection... 5 2.1.4 End control... 5 2.2 Operation instruction... 5 2.2.1 Preparation for start-up... 5 2.2.2 Start-up procedure... 5 2.2.3 Normal operation... 5 2.2.4 Shut-down... 5 2.3 Maintenance... 6 2.3.1 Every 6 months... 6 2.3.2 Yearly... 6 3 PNEUMATIC FIRE AND GAS DAMPERS... 6 3.1 General information... 6 3.1.1 Connection to ductwork... 6 3.1.2 Air connection... 6 3.1.3 Electric connection... 6 3.1.4 End control... 7 3.2 Operation instruction... 7 3.2.1 Preparation for start-up... 7 3.2.2 Start-up procedure... 7 3.2.3 Normal operation... 7 3.2.4 Shut-down... 7 3.3 Maintenance... 8 3.3.1 Every 6 months... 8 3.3.2 Yearly... 8 2

1 INSTALLATION, OPERATION AND MAINTENANCE MANUAL This document contains instructions regarding installation, operating and maintenance of the following dampers - Pneumatic Shut-off dampers - Pneumatic Fire & Gas dampers 1.1 GENERAL INTRODUCTION Purpose of this procedure is to ensure proper operation and maintenance of dampers. All the equipment is delivered in accordance with requirements in the contract documents. Details about the equipment is covered by other documents. 1.2 SCOPE The actuator on pneumatic dampers operates through the solenoid valve. If the solenoid valve loose power, the pressure will drain through the exhaust valve, and the damper closes. Limit switches for detecting closed/open damper is detected from metal-plate that rotate with actuator-nob for safe detecting of the damper position. If loss of air supply or electrical power, the damper will go to close position. Gasket on blades is provided to meet specifications for fire and gastight dampers. The gasket is made of self-adhesive cellular neoprene. 1.3 HEALTH AND SAFETY INFORMATION 1.3.1 Requirements Contamination of instrument air with dirt and some lubrication media will result in damage to actuator and shaft seals, and/or seals for solenoid valve. Instrument air shall be clean and dry. Moisture will result in corrosion of the springs and potential damage of the seals. Over pressure of instrument air will result in damage to seals. Pressure shall be within the limits defined on project data sheets. Over/under voltage to the coil will result in the solenoid valve failing closed. Voltage shall be within +/- 10% of the rated voltage for the product. The client must ensure that the actuator is operated at within the specified operational temperature range. Operating at higher/lower temperature could result in failure of the seals. 3

1.3.2 Warning all dampers During opening and closing of the dampers, manually-electrically or by pneumatic force, be aware of the following: - The actuator spring return movement - The pinching movement of the blades - The pinching movement of the linkage (if applicable) - The pinching movement of the limit switch flag - The pinching movement of the indicator pointer Trained personnel who guarantee restoration to its original condition must carry out the overhauls and repairs. We recommend that you contact an authorized repair agent. Never produce any hazardous situations by climbing without safety devices. 2 PNEUMATIC SHUT-OFF DAMPERS 2.1 General information 2.1.1 Connection to ductwork Check the flanges on the ductwork and equipment for damages. Remove any dirt and foreign parts from the flanges. Mount the gasket on the ductwork flange. Connect the equipment to the ductwork flange, and fasten the equipment with described screws, washers, spring washers and nuts. To tighten the bolts, start from the centre of the flanges and work to both sides to the corner bolts. Do not bend the damper flanges to fit the screws. After tightened the bolts, the damper parts must be tested for smooth movement. On automatic operated dampers, be aware of correct supply to the damper. If the ductwork continues, use the same procedure as earlier described. Check once again the damper parts for smooth movements. 2.1.2 Air connection The internal tubing is cleaned, connected and tested by BAAS. Check drawings for correct size of supply connection. Please ensure that pneumatic tubing is cleaned before connection. Check air pressure before operation. 4

2.1.3 Electric connection Damper with limit switches and solenoid valve has a junction box. The electrical components are adjusted and the loops are tested by manufacturer. Before the electric power is switched on, make sure the voltage is correct. For more information, please refer to the wiring diagram. 2.1.4 End control When the installation is complete, you need to make a function test of the damper. Open and close the damper a few times to be sure that the damper operates correctly. Both manually and with control signal, if applicable. 2.2 Operation instruction 2.2.1 Preparation for start-up Check that the connection to the position is correctly installed. Check that the correct air line is connected to the correct connection point, with correct air pressure. Check that the mechanical opening device handle, if supplied, is removed from the attachment shaft. 2.2.2 Start-up procedure With compressed air, open and close each separate damper 2 or 3 times. Check that the damper open and close without excess resistance. The position of all dampers at start up is described in the start-up procedure for the HVAC-system. 2.2.3 Normal operation The dampers are operated according to the ventilation operation procedure. 2.2.4 Shut-down The damper shall fail safe to a closed position on loss of instrument air via spring return mechanism. The damper solenoid is provided with a valve and quick connector for use in a black start situation. If loss of air supply or electrical power occurs, the damper will go to close position. 5

2.3 Maintenance 2.3.1 Every 6 months Shut off the air to the damper and make a visible inspection of the components in the drive-unit. Open and close the damper according to system operation specification, to visually see that the damper blades move from open to closed position. Look at the arrow on the drive-unit for confirmation. Use the signal to the control panel to check that the signal from the limit switch is given. 2.3.2 Yearly Clean the components and linkage if dirty. Use some drops of machinery oil on the moving parts. If there is some damage on the painting on the actuator, clean the spot and coat the area with zink primer. 3 PNEUMATIC FIRE AND GAS DAMPERS 3.1 General information 3.1.1 Connection to ductwork Check the flanges on the ductwork and equipment for damages. Remove any dirt and foreign parts from the flanges. Mount the gasket on the ductwork flange. Connect the equipment to the ductwork flange, and fasten the equipment with described screws, washers, spring washers and nuts. To tighten the bolts, start from the centre of the flanges and work to both sides to the corner bolts. Do not bend the damper flanges to fit the screws. After tightened the bolts, the damper parts must be tested for smooth movement. On automatic operated dampers, be aware of correct supply to the damper. If the ductwork continues, use the same procedure as earlier described. Check once again the damper parts for smooth movements. 3.1.2 Air connection The internal tubing is cleaned, connected and tested by BAAS. Check drawings for correct size of supply connection. Please ensure that pneumatic tubing is cleaned before connection. Check air pressure before operation. 3.1.3 Electric connection Damper with limit switches and/or solenoid valve has a junction box. Necessary holes for incoming cable glands must be drilled in the junction box, if not specified. It is 6

preferable to do this before the damper is mounted. The electrical components are adjusted and the loops are tested by manufacturer. Before the electric power is switched on, make sure the voltage is correct. For more information, please refer to the wiring diagram. 3.1.4 End control When the installation is complete, you need to make a function test of the damper. Open and close the damper a few times to be sure that the damper operates correctly. 3.2 Operation instruction 3.2.1 Preparation for start-up Check that the connection to the position is correctly installed. Check that the correct air line is connected to the correct connection point, with correct air pressure. Check that the mechanical opening device handle, if supplied, is removed from the attachment shaft. 3.2.2 Start-up procedure With compressed air, open and close each separate damper 2 or 3 times. Check that the damper open and close without excess resistance. The position of all dampers at start up is described in the start-up procedure for the HVAC-system. 3.2.3 Normal operation The dampers are operated according to the ventilation operation procedure. 3.2.4 Shut-down The damper shall fail safe to a closed position on loss of instrument air via spring return mechanism. The damper solenoid is provided with a valve and quick connector for use in a black start situation. If loss of air supply or electrical power occurs, the damper will go to close position. For Fire Dampers equipped with a trigger: the damper will close if the trigger nut smelts. 7

3.3 Maintenance 3.3.1 Every 6 months Shut off the air to the damper and make a visible inspection of the components in the drive-unit. Open and close the damper according to system operation specification, to visually see that the damper blades move from open to closed position. Look at the arrow on the drive-unit for confirmation. Use the signal to the control panel to check that the signal from the limit switch is given. If the damper has air trigger, ensure that there is no dirt in the trigger unit. After removing the air trigger insert, check the melting nut. 3.3.2 Yearly Clean the components and linkage if dirty. Use some drops of machinery oil on the moving parts. Shut-off the air supply and open the air trigger. Remove insert and clean the melting nut. 8