Electrical linear actuator with safety function MC100FSR/24

Similar documents
Electrical linear actuator with safety function MC100FSR/230

Electrical linear actuator MC15/24-C

Elektric actuator MC50/24-C

MD15-C, MD15-HR, MD15-HE and MD15-DA Small Actuators for Rxx and RWxx Valves and Danfoss of the Series RA

TV1/BW..TV4/BW and TV1/BW-S6..TV4/BW-S6 Immersion Temperature Sensors

MD210Y Actuator with valves of the RK/RB/RF/RFH/RGD/RWG series. Application. Product Description

Overview of types. Technical data

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

Type Operating Instructions. Angle Seat Motor Valve Compact. BM24C, BM24C/I BM24C/IOS, BM230C/IOS with and without spring return

Electro-hydraulic actuators for valves

Operating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN

Mounting and Operating Instructions EB 5868/5869 EN

Modulating control valves with magnetic actuator PN 16

Type 3360, Service Manual. Serviceanleitung Service Manuel

Modulating control valves with magnetic actuators, PN 16

Operating Instructions. Angle Seat Control Valve. Type 7020

NV Direct Coupled Globe Valve Actuator

4/3 directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE)

2- and 3-port valves with flanged connections, PN 16

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

M A N U A L. Field Current Controller F2.2

Installation Instructions Spector compact Conductivity Transmitter System LRGT 16-1

Type 3320, Service Manual. Serviceanleitung Service Manuel

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation

VP23 3-way proportional pressure control valve Directly-controlled seat valve with µp-driven pressure control G 1/4... G 3/4

Type 2000, Operating Instructions. Bedienungsanleitung Manuel d utilisation

2- and 3-port valves with flanged connections, PN 16

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Operating Instructions

Electro-hydraulic actuators for valves

MXG MXF Modulating control valves PN 16 with magnetic actuators. Building Technologies HVAC Products

Operating Instructions

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

Electronic Globe Valves

MD50Y Intelligent Linear Actuator

Differential Pressure Sensors

Electromotoric actuators

Operating instructions

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Modulating control valves with magnetic actuator PN 16

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Assembly and Maintenance Manual Type ASNU

EB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions

ARI-PACO Electric thrust actuator

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

VP23. 3-way proportional pressure control valve Directly-controlled seat valve with μp-driven pressure control G 1/4 to G 3/4 Nominal diameter 8/16

2- and 3-port valves with flanged connections, PN 16

Combi valves PN 16 with flanged connections

Operating instruction Refrigerant Valves PS45

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Oil-free piston compressors KK and piston vacuum pumps KV

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

2- and 3-port valves with flanged connections, PN 6

Pressure relief valve

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

Baelz-electrodyn Actuator for modulating duty Motorized linear actuator baelz 373-E45

Angle sensor AN2 series 30

Electromotoric Actuators

SSA955. Synco living Radiator Control Actuator

Mounting and Operating Instructions EB EN. Type 3372 Electropneumatic Actuator. Actuator area: 120 and 350 cm² With Type 3725 Positioner

Angle seat valve with diaphragm actuator VZXA-...-M

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Pilot-Operated Proportional DC Valve Series D*1FH

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

Angle seat valve with piston actuator VZXA-...-K

Operating Instructions

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

System 6000 Electropneumatic Converters for DC ranges I/P Converter Type 6102 Type 5288

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

Installation and Operating Instructions for EAS -NC clutch Type 45_. _. _ Sizes 02 and 03

Condensate Drain Valve AK 45. Original Installation Instructions English

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

KeContact P20. User manual

CV 206/216/306/316 GG. Standard control valves 2- or 3-way, DN , cast iron

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrohydraulic actuators for valves

Assembly and Maintenance Manual Type AS

Type S030. Operating Instructions. Symbols used. INLINE fitting. Bedienungsanleitung Manuel d'utilisation

Starting up hydraulic systems

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI

3-port valves vxf42..

2- and 3-port valves with flanged connections, PN 25

Electro-hydraulic actuators for valves

ACTUATORS POSITION SENSOR

2- and 3-port valves with flanged connections, PN 25

Strainers with flanged connections Type 2 N Type 2 NI. Type 2 N/2 NI Strainers. Mounting and Operating Instructions EB 1015 EN

ProMinent. Operating Instructions Turbine Meter turbodos

Electronic Pressure Switches

VLF45... Hot Air Valves. Siemens Building Technologies HVAC Products

ACTIVAL Two-way Ball Valve with Threaded-end Connection

Operating Instruction for Electronic Pressure Switch. Model: PDD

Pilot operated proportional directional valves

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Transcription:

Issue 2013-05-24 Operating manual 3.10-TA.210-20-EN Electrical linear actuator with safety function Application Linear actuator with automatic coupling and safety function for fine stroke adjustment of two-way and three-way valves. The linear actuator is continuously controlled using either a DC 0(2) 10 V or 0(4) 20 ma signal. The linear actuator includes a safety function, which uses spring force to open or close valves (depending on the type of valve used) when the power supply is interrupted. Content Page Important Information Regarding Product Safety...2 Electrical linear actuator with safety function...3 Technical Data...3 Dimensions...4 Connection...4 Actuator Functions...5 Installation...7 Valve Installation...8 Mounting...9 Removal...11 Commissioning...13 General Information...13 Commissioning Steps...14 Änderungen vorbehalten - Contents subject to change - Sous réserve de modifications - Reservado el derecho a modificación - Wijzigingen voorbehouden - Con riserva di modifiche - Innehåll som skall ändras - Změny vyhrazeny - Zmiany zastrzeżone - Возможны изменения - A változtatások jogát fenntartjuk - 保留未经通知而改动的权力

Operating manual 3.10-TA.210-20-EN Issue 2013-05-24 Important Information Regarding Product Safety Safety Instructions This data sheet contains information on installing and commissioning the product "". Each person who carries out work on this product must have read and understood this data sheet. If you have any questions that are not resolved by this data sheet, you can obtain further information from the supplier or manufacturer. If the product is not used in accordance with this data sheet, the protection provided will be impaired. Applicable regulations must be observed when installing and using the device. Within the EU, these include regulations regarding occupational safety and accident prevention as well as those from the VDE (Association for Electrical, Electronic & Information Technologies). If the device is used in other countries, it is the responsibility of the system installer or operator to comply with local regulations. Mounting, installation and commissioning work on the devices may only be carried out by qualified technicians. Qualified technicians are persons who are familiar with the described product and who can assess given tasks and recognize possible dangers due to technical training, knowledge and experience as well as knowledge of the appropriate regulations. Legend WARNING Indicates a hazard of medium risk which can result in death or severe bodily injury if it is not avoided. CAUTION Indicates a hazard of low risk which can result in minor or medium bodily injury if it is not avoided.! NOTICE Indicates a hazard of medium risk which can result in material damage or malfunctions if it is not avoided. NOTE Indicates additional information that can simplify the work with the product for you. Notes on Disposal For disposal, the product is considered waste from electrical and electronic equipment (electronic waste) and must not be disposed of as household waste. Special treatment for specific components may be legally binding or ecologically sensible. The local and currently applicable legislation must be observed. Page 2 / 16

Issue 2013-05-24 Operating manual 3.10-TA.210-20-EN Electrical linear actuator with safety function AC 24 V linear actuator with DC 0(2) 10 V or 0(4) 20 ma continuous control Safety function: Linear actuator function retracts without power Technical Data Nominal voltage AC 24 V ± 15%, 50/60 Hz; 26 VA Control Constant, optionally adjustable - with voltage signal DC 0(2) 10 V; 0.5 ma; invertible - with current signal 0(4) 20 ma; invertible Compensation of external interferences on the control signal through dynamic hysteresis Drive Brushless DC motor Actuating stroke Max. 20 mm, automatic stroke adjustment through initialization Positioning time 2 s/mm actuating stroke Emergency actuating Approx 1 s/mm time Thrust 1000 N Position indication Stroke range scale Position feedback DC 0(2) 10 V, 5 ma for 0 100% stroke, invertible, or 0(4) 20 ma, Ri= 0.5 kω for 0 100% stroke, invertible Valve monitoring Automatic valve block monitoring with fault signal greater than approx. 12.5 V or 20 ma Valve block protection Optionally adjustable Manual adjustment Socket for hexagon socket key beneath the drive hood, key socket 4 mm, locking using knob. Ambient temp. 0 50 C Degree of protection IP54 Protection class III in accordance with EN 60730 Installation position Anywhere from vertical above the valve to a horizontal position Maintenance Maintenance-free Weight 2.80 kg Page 3 / 16

Operating manual 3.10-TA.210-20-EN Issue 2013-05-24 Dimensions 145 95 242 100 Ø 30 Ø 9 50 Connection UB N1 N2 Y X 24V AC N (GND) Page 4 / 16

Issue 2013-05-24 Operating manual 3.10-TA.210-20-EN Actuator Functions Automatic mode / Testing the safety function 1 2 (1) Switch (2) Indicator slide Automatic mode or testing the safety function can be selected directly on the linear actuator using the switch on the actuator cover. Automatic mode: Slide the switch to position. Testing the safety function: Slide the switch to position. When the safety function test feature is activated, the extended indicator slide allows this status to be recognized even in poorly lit areas. After the safety function test has been switched off, the linear actuator automatically returns to automatic mode. Position indicator on the linear actuator The current stroke position of the valve is indicated by the position of the stroke range scale (3). 3 Automatic malfunction message If the valve stroke is blocked by the presence of foreign objects in the pipeline, the linear actuator reports this malfunction with a feedback signal approx. >DC 12.5 V (terminal A). The LED below the actuator cover also flashes (short flashes). The linear actuator then automatically tries to correct the valve block using a remedy algorithm, which repeatedly lifts the valve cone for a short time. A manual activation of the safety function or manual adjustment is also signaled by a feedback signal of approx. > DC 12.5 V. Page 5 / 16

Operating manual 3.10-TA.210-20-EN Issue 2013-05-24 Zero crossing The economical three-wire connection combines the zero potentials of control line Y (direct current) and of the power line (alternating current) into one wire. The Y control signal is processed by software to reduce errors in the Y control signal caused by voltage drops arising from very long cable lengths. Run time lag after mains power recovery After power has been lost for a longer time, the linear actuator moves out of the safety position to the current nominal position with reduced positioning speed. When the current control position is reached, it is switched over to the positioning speed that is set. This prevents oscillations in steam systems and monitoring from being triggered when power is recovered. Page 6 / 16

Issue 2013-05-24 Operating manual 3.10-TA.210-20-EN Installation CAUTION Electrical installation and unit connection may only be carried out by qualified technicians. The mains supply may only be connected after commissioning. Be sure to comply with VDE guidelines and local wiring regulations. The device is connected according to the obligatory wiring diagram. CAUTION The electrical connection of the linear actuator must be carried out as a fixed installation. An M16 x 1.5 screw fitting (included in the scope of delivery of the linear actuator) is to be used as a strain relief device. The electrical connection is to be made using plug-in screw terminals (connection diameter 0.3 mm to 2.3 mm). CAUTION There is a risk of getting crushed between the cross member and the spring pan. The safety function of the linear actuator automatically moves the valve into the upper end position using high spring force when the power supply is interrupted. M16x1,5 M20x1,5 5mm...8mm 1 2 3 4 5 6 7 8 Page 7 / 16

Operating manual 3.10-TA.210-20-EN Issue 2013-05-24 Valve Installation! NOTICE The valve may only be installed by qualified technicians. In addition to the generally valid installation guidelines, the following points are to be observed: The valve gates come with protective caps to protect against contamination. They are to be removed before installing the valves. The pipeline system and the interior of the fixture must be free of foreign objects. In the event of contaminated media, dirt collectors are to be inserted upstream of the valves. There must be no tension between the fixture and the pipeline connection. Use only perfectly fitting flange seals, inserted centrally in the valve flanges. To avoid eddy formations in the valve body, the valve should be installed in a straight section of the pipe. A distance of 10 times the nominal diameter is recommended between the valve flange and manifold or other similar parts. The installation location is to be selected so that the ambient temperature at the linear actuator is kept between 0 C and +50 C. When the valve is being installed, the permissible max. pressure difference Δp and the specified flow direction are to be observed. The linear actuator can be installed vertically above the fixture, or in any position as far as a horizontal position. When installed horizontally, the drive pillars must be one upon the other. Where applicable, turn the cross member after loosening the retaining nut. To remove the linear actuator cover, approx. 100 mm of free space is required above the actuator. The linear actuator is delivered with a protective box. Up until commissioning, this cover protects the linear actuator during the installation phase and pipeline work. Observe the direction of flow arrow on the valve body. Inverting the direction of flow impairs control behavior. Page 8 / 16

Issue 2013-05-24 Operating manual 3.10-TA.210-20-EN Mounting Installation instructions 90 90 > 100 mm Mounting and installation ISO 4762-M8x16-8.8 6mm 1 2 3 4 5 6 7 Ø 4 mm 8 DIN 912-M8x35-8.8 M16x1,5 S8 6mm M20x1,5 9 10 11 12 5mm...8mm 13 14 15 16 Page 9 / 16

Operating manual 3.10-TA.210-20-EN Issue 2013-05-24 17 18 19 20 Klick 21 22 23 24 If the valve is installed in the plant, ensure that no differential pressure builds up in the valve body before beginning work. If necessary, close the gate valve and switch off pumps. After the pipeline has cooled off, you can begin installation of the linear actuator. Once the linear actuator has been mounted and installed, you must trigger an automatic initialization run, see Commissioning Steps.! NOTICE Both hexagon socket screws must be tightened equally with the hexagon socket key (see Fig. 8). Page 10 / 16

Issue 2013-05-24 Operating manual 3.10-TA.210-20-EN Removal 1 2 3 4 5 6 7 6mm 8 4mm 10 mm 9 10 11 12 13 14 15 16 17 18 19 20 Page 11 / 16

Operating manual 3.10-TA.210-20-EN Issue 2013-05-24 Ø 4 mm 21 22 23 24 6mm 25 26 27 28 Before beginning to remove the unit, make sure that no differential pressure builds up in the valve body before beginning work. If necessary, close the gate valve and switch off the pumps. After the pipeline has cooled off, you can begin removal of the linear actuator. Disconnect the linear actuator from the mains power supply. Then disconnect all electrical connections. Page 12 / 16

Issue 2013-05-24 Operating manual 3.10-TA.210-20-EN Commissioning Operating and functional components beneath the linear actuator cover 4 1 2 3 5 6 (1) Switch for setting the functions (2) Status LED display (3) INIT button (4) Receptacle for the knob during manual adjustment (5) Socket for hexagon socket key (6) Receptacle for the knob during automatic mode without cover during commissioning General Information! The commissioning process may change if accessories are installed. In such cases, commissioning is described in the data sheet of the accessory that is being used. NOTICE Automatic mode without the cover may only be used by the technician during commissioning. 1 2 2 Knob not inserted = safety function triggered Knob inserted = automatic mode! When the cover is removed, the linear actuator automatically tests the safety function and moves into its safety position to maintain safe operation. To allow the commissioning technician to test for proper function, the linear actuator can be switched to automatic mode by inserting the knob (1). Remove the actuator cover and then insert the knob (1) into the PCB (2). NOTICE Observe after installing the linear actuator If the linear actuator was installed on-site, the nominal stroke must be adjusted to the valve stroke using initialization (INIT). Page 13 / 16

Operating manual 3.10-TA.210-20-EN Issue 2013-05-24 Status of the LED displays LED beneath the linear actuator cover Permanent light Short flashes Long flashes Meaning Normal operation Malfunction / voltage polarity incorrect Initialization run Commissioning Steps 1. Testing for proper actuating device installation and testing the electrical connection 2. Adjusting the valve functions The valve function is adjusted using the 4 switches beneath the linear actuator cover. (1) Switch: Switch on/switch off valve block protection (2) Switch: Setting of the control range of the actuating signal (3) Switch: Setting of the actuating signal Y and position feedback live or energized Factory setting: O (off) Factory setting: 0 10 V/0 20 ma Factory setting: V 1 2 3 4 Feedback when the valve is blocked or during manual adjustment is - energized feedback signal > approx. 12.5 V - live feedback signal 0 ma (with 4 20 ma) (4) Switch: Sequence setting for controlling Factory setting: the actuating direction valve open or valve closed (e.g. DC 0 10 V or DC 10 0V) Position feedback NOTE Inverting the control signal ( / ) also adjusts the sequence of the position feedback. The control signal and the actuating feedback are coupled to each other in their sequence. Page 14 / 16

Issue 2013-05-24 Operating manual 3.10-TA.210-20-EN Actuating direction Two-way valve Three-way valve M M M Switch position Y = DC 10 V AB B A AB B A Switch position Y = DC 10 V AB B A AB B A = open = closed = flanged off 2. Switching on the power supply LED (2) flashes. 4. Initialization and adjustment to the valve stroke Remove the actuator cover and then insert the knob (4) into the PCB (see diagram). 4 The initialization run is switched on by pressing the INIT button (3). The valve is completely opened and closed once during initialization. LED (2) flashes during initialization. The linear actuator always moves first to the upper end position and then to the lower end position. The LED remains constantly lit to signal that initialization is completed. 1 2 3 UB N1 UB N1 N2 24V~ N Y X 5. Valve block protection Block protection prevents the ball from jamming when the valve is not moved for a longer period of inactivity, e.g. for heating systems, during the summer. When block protection is activated, the valve ball is lifted for several seconds if there is no stroke movement for 24 hours. Block protection is not activated when the unit is delivered. If plant specifications permit, the valve block protection feature may be activated. Valve block protection can be switched on during the initialization phase. Valve block protection is switched on and off using switch (1), which is located beneath the drive hood. Page 15 / 16

Operating manual 3.10-TA.210-20-EN Issue 2013-05-24 6. Manual adjustment Remove the actuator cover for manual operation. The valve can be moved into any position using a hexagon socket key (key socket 4 mm). The knob is then used to lock the linear actuator. 7. Accessories If additional components are installed on the linear actuator (see accessories), their functionality must be tested and adjusted as necessary. You must follow the accessories descriptions with connection instructions when doing so. 8. Function test Replace and tighten the screws of the linear actuator cover after the actuator settings have been made with any accessories. Then test the complete functionality of the actuator in the control system, including the emergency function. Page 16 / 16